Thank you for choosing the Cisco Catalyst Series Switch. These switches combine powerful network performance and reliability with a complete suite of network features that you need for a solid business network. These expandable Gigabit Ethernet switches, with Gigabit or 10-Gigabit uplinks, provide multiple management options, rich security capabilities, and Layer-3 static routing features far beyond those of an unmanaged or consumer-grade switch, at a lower cost than fully managed switches.
Before You Begin
Before you begin installing your device, ensure that the following items are available:
- RJ-45 Ethernet cables for connecting network devices. A category 6a and higher cable is required for 10G ports; a category 5e and higher cable is required for all other ports.
- Tools for installing the hardware.
- The rack-mount kit packed with the switch contains four rubber feet for desktop placement, and two brackets and twelve screws for rack mounting.
- If the supplied screws are lost, use replacement screws in the following size:
- Diameter of the screw head: 6.9 mm
- Length of the face of the screw head to the base of screw: 5.9 mm
- Shaft diameter: 3.94 mm
Features of the Cisco Catalyst C1300 Switches
[Warning] To prevent airflow restriction, allow clearance around the ventilation openings to be at least 3 inches (7.6 cm).
A computer to manage the device either via the console port or via the web-based interface. For web-based interface, the computer needs to support one of the following browsers:
- Microsoft Edge
- Firefox (version 82 or 81 or higher)
- Chrome (version 86 or 85 or higher)
- Safari over MAC (version 14.0 and higher)
[Warning] Suitable for installation in Information Technology Rooms in accordance with Article 645 of the national Electric Code and NFPA 75.
Cisco Catalyst 1200 and 1300 Series Switches are fixed-managed Gigabit Ethernet enterprise-lite Layer 2 switches designed for small and medium-size businesses and branch offices. These are simple, flexible, and secure switches ideal for any size business. Cisco® Catalyst 1200 and 1300 operate on Linux-based Software. The switches support simple device management and network management via a command-line interface (CLI) as well as an on-box web UI. These switches deliver enhanced network security, network reliability, and operational efficiency for small and medium organizations.
Product Highlights
- 8, 16, 24, or 48-Gigabit Ethernet with multiple PoE and SFP options
- Models support 802.3af PoE and 802.3at PoE+ with a power budget of up to 740W.
- Support Command-Line Interface (CLI) and/or intuitive web UI manageability options
- Security with 802.1X support for connected devices. Web-based authentication provides a consistent interface to authenticate all types of host devices and operating systems, without the complexity of deploying IEEE 802.1x clients on each endpoint.
- Support true stacking capability, allowing you to configure, manage, and monitor all switches in a stack as a single unit with a single IP address.
- Compact fanless models available with a depth of less than 13 inches (33 cm), providing additional deployment flexibility including outside wiring closet installation such as retail stores, open plan offices and classrooms.
- Support for the Energy-Efficient Ethernet (IEEE 802.3az) standards, which reduces energy consumption by monitoring the amount of traffic on the ports and optimizing the power during quiet periods.
- Device management support with over-the-air access via Bluetooth, Simple Network Management Protocol (SNMP), USB-C console access.
Specifications
Product ID Specifications
Product ID* | Gigabit Ethernet | Uplink interfaces | PoE power budget | Fanless | Dimensions (WxDxH in inches) | Weight (kg) |
---|---|---|---|---|---|---|
C1300-8T-E-2G | 8x1G downlink+2xGE (2xcombo) uplink | 2xGE (2xcombo) uplink | N/A | N | 10.56 x 7.28 x 1.73 | 1. |
C1300-8P-E-2G | 8x1G downlink+2xGE (2xcombo) uplink | 2xGE (2xcombo) uplink | 67W | N | 10.56 x 7.28 x 1.73 | 1. |
C1300-8FP-2G | 8x1G downlink+2xGE (2xCombo) uplink | 2xGE (2xCombo) uplink | 120W | N | 10.56 x 7.28 x 1.73 | 2. |
C1300-16T-2G | 16x1G downlink+2xGE SFP uplink | 2xGE SFP uplink | - | N | 10.56 x 10.69 x 1.73 | 1. |
C1300-16P-2G | 16x1G downlink+2xGE SFP uplink | 2xGE SFP uplink | 120W | N | 10.56 x 10.69 x 1.73 | 2. |
C1300-16FP-2G | 16x1G downlink+2xGE SFP uplink | 2xGE SFP uplink | 240W | N | 10.56 x 10.69 x 1.73 | 2. |
C1300-16P-4X | 16x1G downlink + 4x10G | 10G Uplinks, 16x1G + 4x10G | 120W | N | 10.56 x 10.69 x 1.73 | 2. |
C1300-24T-4G | 24x1G Downlink | +4GE SFP uplink | - | N | 17.48 x 9.45 x 1.73 | 3. |
C1300-24P-4G | 24x1G Downlink +4GE SFP uplink | +4GE SFP uplink | 195W | N | 17.48 x 9.45 x 1.73 | 4. |
C1300-24FP-4G | 24x1G Downlink +4GE SFP uplink | +4GE SFP uplink | 375W | Y | 17.48 x 9.45 x 1.73 | 4. |
C1300-24T-4X | 24x1G downlink+4x10GE SFP+ uplink | 4x10GE SFP+ uplink | - | N | 17.48 x 9.45 x 1.73 | 2. |
C1300-24P-4X | 24x1G downlink+4x10GE SFP+ uplink | 4x10GE SFP+ uplink | 195W | Y | 17.48 x 9.45 x 1.73 | 3. |
C1300-24FP-4X | 24x1G downlink+4x10GE SFP+ uplink | +4x10GE SFP+ uplink | 375W | Y | 17.48 x 9.45 x 1.73 | 4. |
C1300-48T-4X | 48x1G downlink+4x10GE SFP+ uplink | 4x10GE SFP+ uplink | - | Y | 17.48 x 13.78 x 1.73 | 3. |
C1300-48P-4X | 48x1G downlink+4x10GE SFP+ uplink | 4x10GE SFP+ uplink | 375W | Y | 17.48 x 13.78 x 1.73 | 5.43 |
C1300-48FP-4X | 48x1G downlink+4x10GE SFP+ uplink | 4x10GE SFP+ uplink | 740W | Y | 17.48 x 13.78 x 1.73 | 5.82 |
Model Specific Features
Note: 50C operation is supported for short-term operation only. Specific thermal limitations apply for certain models and SFP modules at higher altitudes. Refer to the original document for full details.
Connectors and Interfaces:
- Ethernet interfaces: 10BASE-T ports: RJ-45 connectors, 2-pair Category 3, 4, or 5 Unshielded Twisted Pair (UTP) cabling; 100BASE-TX ports: RJ-45 connectors, 2-pair Category 5 UTP cabling; 1000BASE-T ports: RJ-45 connectors, 4-pair Category 5 UTP cabling; 1000BASE-T SFP-based ports: RJ-45 connectors, 4-pair Category 5 UTP cabling.
- Indicator LEDs: Per-port status: link integrity, disabled, activity. System status: System.
- Console cables: CAB-CONSOLE-RJ45 Console cable 6 ft. with RJ-45.
- Power: Use the supplied AC power cord to connect the AC power connector to an AC power outlet. Models have external power supply.
For an updated list of supported MIBs, refer to the MIB Locator at cisco.com/go/mibs.
Feature | 8-port models | 16-port models | 24-port models (1/10G uplinks) | 48-port models (1/10G uplinks) |
---|---|---|---|---|
Console ports (RJ-45 Ethernet) | 1 | 1 | 1 | 1 |
USB-A port for storage and Bluetooth console | 1 | 1 | 1 | 1 |
CPU | ARM v7 800 MHz | ARM v7 800 MHz | ARM v7 800 MHz | ARM v7 800 MHz |
DRAM | 512 MB | 512 MB | 512 MB | 512 MB |
Flash memory | 512 MB | 512 MB | 512 MB | 512 MB |
Environmental | ||||
Operating temperature (Sea level) | -5 to 50 deg C* | -5 to 50 deg C* | -5 to 50 deg C* | -5 to 50 deg C* |
Operating temperature (Up to 5,000ft (1500 m)) | -5 to 45 deg C | -5 to 45 deg C | -5 to 45 deg C | -5 to 45 deg C |
Operating temperature (Up to 10,000 ft (3000 m)) | -5 to 40 deg C | -5 to 40 deg C | -5 to 40 deg C | -5 to 40 deg C |
Operating altitude | 10,000 ft (3,000m) | 10,000 ft (3,000m) | 10,000 ft (3,000m) | 10,000 ft (3,000m) |
Operating relative humidity | 5% to 90% at 40 deg C (non-condensing) | 5% to 90% at 40 deg C (non-condensing) | 5% to 90% at 40 deg C (non-condensing) | 5% to 90% at 40 deg C (non-condensing) |
Storage temperature | -13 to 158F (-25 to 70C) | -13 to 158F (-25 to 70C) | -13 to 158F (-25 to 70C) | -13 to 158F (-25 to 70C) |
Storage altitude | 15,000 ft (4500m) | 15,000 ft (4500m) | 15,000 ft (4500m) | 15,000 ft (4500m) |
Storage relative humidity | 5% to 95% at 65 deg C (non-condensing) | 5% to 95% at 65 deg C (non-condensing) | 5% to 95% at 65 deg C (non-condensing) | 5% to 95% at 65 deg C (non-condensing) |
Front Panel
The ports, LEDs, and Reset button are located on the front panel of the switch, as well as the following components:
- There are 2 device types with different console interfaces:
- Console port with RJ-45 and USB-C connector. If both are connected, the Mini USB has precedence over the RJ-45.
- RJ-45 connector only type of console.
The console interface connects a serial cable to a computer serial port so that it can be configured using a terminal emulation program or USB-C cable (depending on the connector).
- USB Port: The USB port connects the switch to a USB mass storage device so that you can save and restore configuration files, firmware images, and SYSLOG files through the connected USB device. The USB port supports the FAT32 file system.
- RJ-45 Ethernet Ports: The RJ-45 Ethernet ports connect network devices, such as computers, printers, and access points, to the switch.
- SFP+ Port (if present): These are connection points for modules so that the switch can link to other switches. These ports are also commonly referred to as mini 10 Gigabit Interface Converter ports. The term SFP+ is used in this guide.
- SFP+ ports are compatible with various Cisco SFP 1G optical modules (e.g., MGBSX1, MGBLX1, MGBLH1, MGBT1) and other brands.
- Cisco SFP+ Copper Cable modules supported include SFP-H10GB-CU1M, SFP-H10GB-CU3M, and SFP-H10GB-CU5M.
- The LEDs of the corresponding RJ-45 port flash green to respond to the SFP interface traffic.
- Small form-factor pluggable (SFP) ports: These are connection points for modules so that the switch can link to other switches.
- Some SFP interfaces are shared with one other RJ-45 and SFP+ port, called a combo port. When the SFP is active, the adjacent RJ-45 port is disabled.
- Reset button: Used to reset or reboot the switch. The table below displays the reset behavior on the switch.
[Note] Stack Behavior: The reset button disable setting is applied to all units in the stack. If configured, the reset button on all units in the stack is disabled; if not configured, it is enabled. This applies also to units that join an existing stack.
LEDs and Reset Behavior
The following are the global LEDs found on the devices:
Table 1: System LEDs
Color | Meaning |
---|---|
Off | System is not powered on. |
Solid Green | System is operating normally. |
Flashing Green | When not connected to CBD, the flashing green LED can indicate specific information (e.g., stack unit ID indication, reset button push duration, etc.). |
Solid Blue | The CBD agent on the device is connected to the Dashboard. |
Flashing Blue | When connected to CBD, the flashing blue LED supports can indicate specific information (e.g., stack unit ID indication, reset button push duration, etc.). |
Solid Amber | System is receiving power but is not functioning properly. |
Flashing Amber | When detecting hardware or firmware failure, and/or configuration file error, which includes:
|
Table 2: Ethernet Port LEDs
Color | Meaning |
---|---|
Off | No link or port was administratively shut down. |
Solid Green | Link present |
Blinking Green | Activity on the switch. Port is sending or receiving data. |
Solid Amber | PoE port is supplying power for downlink ports. |
Blinking Amber | Port in SW defined warning (error disable, STP block, etc.) for both downlink and uplink ports. |
Port LED Status
- Status 1: PD connects, the PoE supplying Power, Amber LED showing it's ON.
- Status 2: PD boot and Link is established, Amber LED is off and the Green LED is ON/blinking confirming link and traffic.
- Status 3: Once any SW defined errors happen (e.g., error disable), the Green LED is OFF and the Amber LED will be blinking.
- Status 4: When the switch is in Status 2, push the reset button for about 1 second, then the Amber LED will be ON for 5 seconds to indicate the PoE status, and then later it will return to the traffic status (Green LED is ON).
Reset Button Behavior
The following describes the different scenarios when the reset button is pushed for a defined set of time:
- When the Reset button is pushed for less than 1 sec, the Ethernet port LED will light in solid Amber for 5 seconds, when the port is supplying power for the device.
- When the Reset button is pushed for 1 to 5 sec, the system LED continues to be solid Green. If the Reset button is released, the system will not reload, and no action is taken.
- When the Reset button is pushed for 6 to 10 sec, the system LED will slowly flash Green. If the Reset button is released, the system will reload without a factory default.
- When the Reset button is pushed for 11 to 15 sec, the system LED will light in solid Green. If the Reset button is released, the system does not reload, and no action is taken.
- When the Reset button is pushed for 16 to 20 sec, the system LED will rapidly flash Green. If the Reset button is released, the system will reload to factory default settings.
- When the Reset button is pushed for more than 20 sec, the system LED will light in solid Green. If the Reset button is released, the system does not reload, and no action is taken.
Rack Mounting Switch
[Warning] You can mount the switches on any standard size, 19-inch (about 48 cm) wide rack. The switch requires 1 rack unit (RU) of space, which is 1.75 inches (44.45 mm) high.
[Caution] For stability, load the rack from the bottom to the top, with the heaviest devices on the bottom. A top-heavy rack is likely to be unstable and might tip over.
Procedure
- Place one of the supplied brackets on the side of the switch so that the four holes of the brackets align to the screw holes, and then use the four supplied screws to secure it.
- Repeat the previous step to attach the other bracket to the opposite side of the switch.
- After the brackets are securely attached, the switch is now ready to be installed into a standard 19-inch rack.
[Note] Use supplied brackets to rack mount the switch.
Supplied rack mounting for switch models with front mounting position. The mounting ears do not sit flush to the front panel.
Due to design differences, some of the mounting brackets will attach such that the switch will protrude about an inch from the mounting surface.
Supplied rack mounting for switch models with front mounting position. The mounting ears sit flush to the front panel.
Diagram Description: Two diagrams illustrate switch mounting brackets. The left diagram shows a switch with brackets attached, indicating dimensions (44 mm, 21.363.15 mm) and screw hole alignment. The right diagram shows a side view of a bracket with similar dimensions.
Wall Mounting a Switch
You can mount the switches on a wall, using wall studs or to a firmly attached plywood mounting backboard.
[Caution] Read these instructions carefully before beginning installation. Failure to use the correct hardware or to follow the correct procedures could result in a hazardous situation to people and damage to the system.
[Caution] Do not wall-mount the switch with its front panel facing up. Following safety regulations, wall mount the switch with its front panel facing down or to the side to prevent airflow restriction and to provide easier access to the cables.
Procedure (To wall-mount a 24-port switch using brackets):
- Attach a 19-inch bracket to one side of the switch.
- Repeat the previous step to attach the other bracket to the opposite side of the switch.
- After the brackets are securely attached, mount the switch with the front panel facing down. Make sure that the switch is attached securely to wall studs or to a firmly attached plywood-mounting backboard.
Diagram Description: A diagram shows a Cisco switch with brackets attached, illustrating the front panel facing down for wall mounting. It indicates the placement of brackets and the switch orientation.
Procedure (To wall-mount an 8-port switch using mounting screws):
[Note] The screw template is used to align the mounting screw holes and is not included in the box with the switch.
- Position the screw template so that the edge marked as CABLE SIDE ENTRY faces toward the floor. Make sure that the switch is attached securely to wall studs or to a firmly attached plywood mounting backboard.
- Peel the adhesive strip off the bottom of the screw template.
- Attach the screw template to the wall.
- Use a 0.144-inch (3.7 mm) or a #27 drill bit to drill a 1/2-inch (12.7 mm) hole in the two screw template slots.
- Insert two screws in the slots on the screw template and tighten them until they touch the top of the screw template.
Diagram Description: A diagram illustrates the process of installing mounting screws on a wall using a template. It shows the template positioned, screws being inserted, and the final screw placement.
Diagram Description: A diagram shows the final step of wall-mounting an 8-port switch. It depicts the switch being slid down onto the mounted screws until it locks in place.
Stacking the Switches
The Cisco Catalyst Series switches support only native stacking and support up to eight switches. Native Stacking implies that a device can connect to other devices of the same type through its stack ports to form a stack. All units in a native stack must be of the same type.
Stacking is only available on certain models in the Catalyst C1300 switches. These models support 2 types of stacking:
- XG SKU stacking (XG SKU can only stack with XG SKU)
- 1G SKU stacking, 2.5G SKU stacking or 1G/2.5G SKU stacking
Type A: 1G SKU, for example, C1300-48FP-4X
Type B: 2.5G SKU, for example, C1300-8MGP-2X
Type C: 10G SKU, for example, C1300-12XS
The stack rules are as follows:
- C can only stack with C
- A and B can stack with A or B
The switch can only be stacked without Mesh topology. The switches in the same stack are connected together through their stack ports. Depending on the type of stack ports and the desired speed, you may need Cat6a Ethernet cables or Cisco approved modules or cables for the switches.
Some network switches can be connected to other switches and operate together as a single unit. These configurations are called stacks, and they are useful for quickly increasing the capacity of your network.
Configuring Switches
The switch can be accessed and managed over your IP network using the web-based interface, or by using the switch's command-line interface through the console port. Using the console port requires advanced user skills and is only supported on certain models.
The following table shows the default settings used when configuring your switch for the first time:
Parameter | Default Value |
---|---|
Username | cisco |
Password | cisco |
LAN IP | 192.168.1.254 (Default) |
Configuring Your Switch Using the Web-based Interface
To access the switch with a web-based interface, you must know the IP address that the switch is using. The switch uses the factory default IP address of 192.168.1.254, with a subnet of /24. When the switch is using the factory default IP address, the System LED flashes continuously. When the switch is using a DHCP server-assigned IP address or an administrator has configured a static IP address, the System LED is a steady green (DHCP is enabled by default).
If you are managing the switch through a network connection and the switch IP address is changed, either by a DHCP server or manually, your access to the switch will be lost. You must enter the new IP address that the switch is using into your browser to use the web-based interface. If you are managing the switch through a console port connection, the link is retained.
Procedure
- Power on the computer and your switch.
- Connect the computer to any network port.
- Set up the IP configuration on your computer.
- If the switch is using the default static IP address of 192.168.1.254/24, you must choose an IP address for the computer in the range of 192.168.1.2 to 192.168.1.253 that is not already in use.
- If IP addresses will be assigned by DHCP, make sure that your DHCP server is running and can be reached from the switch and the computer. You may need to disconnect and reconnect the devices for them to discover their new IP addresses from the DHCP server.
[Note] Details on how to change the IP address on your computer depend upon the type of architecture and operating system that you are using. Use your computer's local Help and Support functionality and search for “IP Addressing.”
- Open a web browser window.
- Enter the switch IP address in the address bar and press Enter. For example, http://192.168.1.254.
- When the login page appears, choose the language that you prefer to use in the web-based interface and enter the username and password. The default username is cisco. The default password is cisco. Usernames and passwords are both case sensitive.
- Click Log In.
- If this is the first time that you have logged on with the default username and password, the Change username and Password page opens. Enter a new username and password and confirm.
- Click Apply.
[Caution] Make sure that any configuration changes made are saved before exiting from the web-based interface by clicking on the Save icon. Exiting before you save your configuration results in all changes being lost.
The Getting Started page opens. You are now ready to configure the switch. Refer to the Administration Guide or see the help pages for further information.
Configuring Your Switch Using the Console Port
To configure the switch using the console port, which is only supported on certain models, proceed with the following steps:
Procedure
- Connect a computer to the switch console port using a Cisco console cable (purchased separately) or a cable with mini USB connector.
- Start a console port utility such as Hyper Terminal on the computer.
- Configure the utility with the following parameters:
- 115200 bits per second
- 8 data bits
- no parity
- 1 stop bit
- no flow control
- Enter a username and password. The default username is cisco, and the default password is cisco. Usernames and passwords are both case sensitive.
- If this is the first time that you have logged on with the default username and password, the following message appears: "Please change your username AND password from the default settings. Change of credentials is required for better protection of your network. Please note that new password must follow password complexity rules."
- Set a new administrator username and password.
[Caution] Make sure that any configuration changes made are saved before exiting.
You are now ready to configure the switch. See the CLI Guide for your switch.
[Note] If you are not using DHCP on your network, set the IP address type on the switch to Static and change the static IP address and subnet mask to match your network topology. Failure to do so may result in multiple switches using the same factory default IP address of 192.168.1.254.
Console access also provides additional interfaces for debug access which are not available via the web interface. These debug access interfaces are intended to be used by a Cisco Support Team personnel, in cases where it is required to debug device's behavior. These interfaces are password protected. The passwords are held by the Cisco support team. The device supports the following debug access interfaces:
- U-BOOT access during boot sequence
- Linux Kernel access during boot sequence
- Run time debug modes - allows Cisco support team to view device settings and apply protocol and layer 1 debug commands and settings. The run time debug mode is accessible over telnet and SSH terminals in addition to the console.