An all-new user experience and ensuring simple configuration
DAIKIN USER Mobile App
DAIKIN USER is the new App that allows end users of refrigerating systems to interact with the latest generation electronic controllers equipped with Bluetooth technology. It has been developed to be unique: rather than different versions for each device, there is just one App for all compatible current and future devices.
With a simple and intuitive interface and only using a smartphone, DAIKIN USER revolutionises and simplifies the use of refrigerating units, through the use of a mobile device, without the need for PCs, serial converters and optional terminals. Functions and parameters are managed via profiles so as to ensure the correct access level based on the type of user.
Mobile app available on:
The Main Features
- Simple and intuitive multilingual interface
- No new technology or experience needed: smartphones and apps are commonly used by most of the world's population
- Wireless connectivity with the devices via Bluetooth, avoiding the need for additional wiring in the field
- Control of temperatures read-out
- HACCP data recording
- Up-to-date documentation relating to the connected controller
LMS-LMC Inverter Monoblock Features
Standard Equipment
- Inverter driven hermetic reciprocating compressor
- 50/60 Hz power supply
- CE Certified
- [Filter dryer]
- [Electronic expansion valve]
- [Hot gas defrost]
- [Electronic control board]
- [Electrical switchboard] with protection fuses
- Fixed calibration HP switch with automatic reset
- 5m cable for power supply
- 2m cold room lighting cable (light bulb and bulb as option)
- 5m micro-switch door cable (Microswitch as option)
- 5m cable for door heater
LMS only
- [Condensate evaporation tray]
- [Remote control panel] (optional)
- [Condenser fan control] by temperature probe
- [Microchannel condenser]
LMC only
- [Remote control panel] (as standard)
- 5m cable for remote control panel
- [Microchannel air cooled condenser]
Cooling Capacity & Volume (Tamb = 32°C / Tc = 0°C)
Model | Capacity (W) | Volume (m³) |
---|---|---|
LMSEY1A09AVM01 | 1.099W | (8,4m³) |
LMSEY1A13AVM01 | 1.240W | (10,0m³) |
LMSEY2A19AVE01 | 1.922W | (17,4m³) |
LMSEY2A25AVE01 | 2.480W | (25,8m³) |
LMCEY1A13AVM01 | 1.077W | (8,2m³) |
LMCEY2A19AYE01 | 1.991W | (18,5m³) |
LMCEY2A25AYE01 | 3.355W | (39,2m³) |
Cooling Capacity & Volume (Tamb = 32°C / Tc = -20°C)
Model | Capacity (W) | Volume (m³) |
---|---|---|
LMSEY1A09AVM01 | 1.099W | (8,4m³) |
LMSEY1A13AVM01 | 1.671W | (15,3m³) |
LMSEY2A19AVE01 | 1.922W | (17,4m³) |
LMSEY2A25AVE01 | 3.368W | (39,4m³) |
LMCEY1A13AVM01 | 1.645W | (14,9m³) |
LMCEY2A19AYE01 | 2.584W | (27,4m³) |
LMCEY2A25AYE01 | 3.355W | (39,2m³) |
Multiple monoblocks, up to 5 pieces in a master-slave configuration (1 master + 4 slaves), can be installed within one cold room to satisfy the cooling needs.
Technical Specifications - Model Comparison
Model | Power supply (V/Ph/Hz) | Compressor | Compressor displacement (cc) | Refrigerating circuits | Expansion device | Defrost | Condenser fan (nr x mm) | Condenser airflow ¹ (m³/h) | Evaporator fan (nr x mm) | Evaporator airflow ¹ (m³/h) | Evaporator airthrow ² (m) | Operating sound pressure ³ (dBA) | Unit weight (kg) | Cold room temperature range (°C) | Max ambient temperature (°C) | Standards for cooling capacity determination ⁴ | Propane refrigerant charge |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
A LMSEY1A09AVM01 | 230/1/50-60 | Hermetic + inverter | 1 x 14,7 | 1 | EEV | Hot gas | 1 x 230 | 555 | 1 x 230 | 597 | 9,6 | 39,4 | 52 | +10 to -25 | 45 | EN 13215 | Charge limited up to 150 gr per circuit |
A LMSEY1A13AVM01 | 400/3/50-60 | Hermetic + inverter | 2 x 14,7 | 2 | EEV | Hot gas | 2 x 230 | 939 | 2 x 230 | 1114 | 9,6 | 43,9 | 83,5 | +10 to -25 | 45 | EN 13215 | Charge limited up to 150 gr per circuit |
B LMSEY2A19AVE01 | 230/1/50-60 | Hermetic + inverter | 1 x 14,7 | 1 | EEV | Hot gas | 1 x 230 | 532 | 1 x 230 | 336 | 1,3 | 38 | 60 | +10 to -25 | 45 | EN 13215 | Charge limited up to 150 gr per circuit |
B LMSEY2A25AVE01 | 400/3/50-60 | Hermetic + inverter | 2 x 14,7 | 2 | EEV | Hot gas | 2 x 230 | 1030 | 2 x 230 | 865 | 1,7 | 44 | 101 | +10 to -25 | 45 | EN 13215 | Charge limited up to 150 gr per circuit |
C LMCEY1A13AVM01 | 230/1/50-60 | Hermetic + inverter | 1 x 14,7 | 1 | EEV | Hot gas | 1 x 230 | 532 | 1 x 230 | 336 | 1,3 | 38 | 60 | +10 to -25 | 45 | EN 13215 | Charge limited up to 150 gr per circuit |
D LMCEY2A19AYE01 | 400/3/50-60 | Hermetic + inverter | 2 x 14,7 | 2 | EEV | Hot gas | 2 x 230 | 1030 | 2 x 230 | 865 | 1,7 | 44 | 101 | +10 to -25 | 45 | EN 13215 | Charge limited up to 150 gr per circuit |
D LMCEY2A25AYE01 | 400/3/50-60 | Hermetic + inverter | 2 x 14,7 | 2 | EEV | Hot gas | 2 x 230 | 1030 | 2 x 230 | 865 | 1,7 | 44 | 101 | +10 to -25 | 45 | EN 13215 | Charge limited up to 150 gr per circuit |
Notes:
- ¹ According to EN ISO 5801
- ² According to CECOMAF GT 6-001 (final velocity = 0,25 m/s)
- ³ According to UNI EN ISO 3746
- ⁴ EN 13215: "Packaged refrigerating units for walk-in cold rooms - Classification, performance and energy consumption testing"