ALTIS G5
UK Installation instructions DE Montageanleitung CZ Montázní návod DK Monteringsvejledning EE Paigaldusjuhend
TYPE : ALG5 - 144L - 168L

FI Asennusohje FR Notice de montage HU Szerelési útmutató IT Istruzioni di montaggio LT Montavimo Instrukcijos

LV Instalacijas instrukcija NO Monteringsanvisning PL Instrukcja montazu SE Installationsanvisning RU

IP66 / IK08
The luminaire with clear optic should be positioned so that prolonged staring into the luminaire at a distance <2m is not expected
Extreme caution : Do not connect any LED CONNECTION wire (high voltage) inside NTC connector !! It could result in a critical failure and damage irreversibly the ALTIS luminaire

=9.3 kg
Caution, risk of electric shock Danger, risque de chocs électriques
The light source contained in this luminaire shall only be replaced by the manufacturer or his service agent or a similar qualified person.

LED
CLASS I

19/30/36 4/8/10

T20/T26

SZ3

1 GEAR BOX : ALG5 GB LE

ALG5 GB 2CH / ALG5 GB 3CH

=5.6 kg

=5.4 kg / 6.1 kg

Sea side
>5 km

TaMIN = -40°C / TaMAX = +50°C
(up to 50°C with driving current derating)
IP66 / IK08

96681048-05

TaMIN = -40°C / TaMAX = +55°C
(up to 55°C with driving current derating)
IP66 / IK08

11/2023

2 DIMENSIONS
675

ALG5 - 144L - 168L

R181.8

285 170

372

125

147.5 90

170

144.6

ALG5 1 BRICK

ScX15° *
0.072

ScX45° *
0.112

ScX65° *
0.16

ScX90° *
0.17

* These data refer to the worst case at indicated angle
ALG5 GB LE

152

500

ALG5 GB 2 CH /AL G5 GB 3 CH

77 120

150
96681048-05

500
11/2023

3
For installation higher >3m Secure product with retaining cable attached to the frame (not included in the delivery). Please refer to local installation norms/regulations.

Ø15

Ø22 Ø15

G /GYRBELBYARCOKWN NTLCELDE-D+

2 1 2

100 200

250 min
1 1xM20 with extra large washer
4
1
8 3
20Nm
8
96681048-05

G /GYRBELBYARCOKWN NTLCELDE-D+

130 135150 165180165

30 45 60

60 45 30 15 0 15

2 2xM14 with extra large washer
OK
2
115°
150 135 120 105 90 75
11/2023

5

ALG5 144L125 - 740 PST NB ANT

ALG5 168L

Symmetrical / Elliptical beam (NB, MB, WB, EB)

Asymmetrical beam (A4, A5, A6, AI5, AI6, EW2)

180 165 150 135120105
120105

0 15
0 15 30 45 60 75

60° 0°

60°
90 75 60 45 30 15

96681048-05

30 45 16300 135150165

Brick orientation

90 75 60 45 30 15

4

20 Nm 5
8

11/2023

6 10°
0°
-5° 0°

175° 175°

96681048-05

OK

11/2023

7 CONNECTION BOX

2
H4

2

Position 1

1

OR Position 2

Position 2 Position 1

1

H4

H4

IP6
H4

H4

H4

IP6
H4

OK
70° max 0°

OK
90° 70°

96681048-05

11/2023

8 CONNECTION BOX ALTIS G5 2 x 1 Luminaire
2
3
1

Luminaire 1

4 Luminaire 2

RED BLACK GREY G / Y

LED+ LEDNTC

Luminaire 2
Extreme caution : Do not connect any LED CONNECTION wire (high voltage) inside NTC connector !! It could result in a critical failure and damage irreversibly the ALTIS luminaire

RED BLACK GREY G / Y

LED+ LEDNTC

RED BLACK GREY G / Y

LED+ LEDNTC

Luminaire 1

H30 4,5 Nm
1 N

PH1 1 Nm
1 RED 2 BLACK
2
3 GREY
3
G / Y N NOT USED

REF : PHOENIX CONTACT PRC 5 FC MS6 8-21 PHOENIX CONTACT PRC 5 FC MS6 8-21 HR

96679580 ALTIS G5 CON 5P M+F 600V X1

96681048-05

11/2023

9 ELECTRICAL CONNECTION
Luminaire 2
T25 2Nm

Luminaire 1

Output side

ALG5 GB LE

ALG5 GB 2 CH

50 mm

5 1234

100 10

Extreme caution : Do not connect any LED CONNECTION wire (high voltage) inside NTC connector !! It could result in a critical failure and damage irreversibly the ALTIS luminaire

G/Y 5* 1 2 3 4 G/Y 5* 1 2 3 4

OK
Ø min = 1,0 mm² Ø typ = 1,5 mm² Ø max = 2,5 mm²

H 36 5 Nm

CABLE GLAND

TYPE

ØMin

ØMax

M32

13 mm

21 mm

Number 1 2 3 4
5

Label +1 -1 +2 -2
+3 -3 NTC GND GND

PINOUT
Description LED1+Connection LED1-Connection LED2+Connection LED2-Connection
NO CONNECT NO CONNECT Thermal Measure INPUT PROTECTIVE EARTH PROTECTIVE EARTH
ALG5 GB 2 CH

Luminaire 1 Luminaire 2

Lenght max = 200 m

96681048-05

Lenght max = 200 m

ALG5 GB LE

11/2023

10 ALG5 GB 2CH / ELECTRICAL CONNECTION / DALI 2 Channels

50

8

OK

Mains (IN) M25
Signal LED

Output (OUT) M32
Ventilation valve

Floodlight

DALI Re-launch (IN/OUT) M16

DALI (IN/OUT)

1

4

M16

2

5 1234

LP2rot:ectLivN1e/LE:oarrtLhL1/N/L2o/rLL31/L2/L3

3

19/30/36

Extreme caution : Do not connect any LED CONNECTION wire (high voltage) inside NTC connector !! It could result in a critical failure and damage irreversibly the ALTIS luminaire

Number

Label
L1 L2
DA+ DA+ DADA-
LUM

5

NTC

1

+1

2

-1

3

+3

4

-3

PINOUT
Description
AC LINE 1 INPUT AC LINE 2 INPUT PROTECTIVE EARTH
DALI INPUT DALI RE-LAUNCH
DALI INPUT DALI RE-LAUNCH
PROTECTIVE EARTH FOR LUMINAIRE
THERMAL MEASURE INPUT
LED1+CONNECTION LED1-CONNECTION LED3+CONNECTION LED3-CONNECTION

4
Luminaire 1 Luminaire 2
Recommended H07RNF 3G1,5 mm²

SIGNALLING LED INDICATIONS ON THE GEAR BOX

PERIOD PULSES

FAULT DESCRIPTION

1

The encoded

faults are

5

based on pulses

emitted every

2

4 seconds 3

One or more active outputs is not working Undervoltage on one or more active outputs
short circuit on one or more active outputs One or more active outputs disconnection from load

4

Overload on one or more active outputs

PRIORITY Maximum
Minimum

LUM
DADA DADA
5 1 2 3 4

CABLE GLAND

TYPE M16 M25 M32

ØMin 5 mm 10 mm 13 mm

ØMax 10 mm 17 mm 21 mm

SEAL REDUCER for GB and FLOOD

TYPE

ØMin

ØMax

M32

10 mm

16 mm

96681048-05

11/2023

11

ALG5 GB 2 CH / ELECTRICAL CONNECTION / RDM-DMX 2 Channels

50

8

OK
Ø min = 1,0 mm² Ø typ = 1,5 mm² Ø max = 2,5 mm²
2

Mains (IN) M25
Signal LED

Output (OUT) M32
Ventilation valve

Floodlight

DALI Re-launch (IN/OUT) M16

1

DALI (IN/OUT)

4

M16

7 1234

LP2rot:ectLivN1e/LE:oarrtLhL1/N/L2o/rLL31/L2/L3

3

19/30/36

Extreme caution : Do not connect any LED CONNECTION wire

LUM

(high voltage) inside NTC connector !! It could result in a critical

failure and damage irreversibly the ALTIS luminaire

Number

Label
L1 L2
A A B B S S
LUM

7

NTC

1

+1

2

-1

3

+3

4

-3

PINOUT
Description
AC LINE 1 INPUT AC LINE 2 INPUT PROTECTIVE EARTH DMX INPUT DATA+ DMX-RE-LAUNCH DATA+ DMX INPUT DATADMX-RE-LAUNCH DATADMX COMMON / SHIELD DMX COMMON / SHIELD PROTECTIVE EARTH FOR
LED MODULE
THERMAL MEASURE INPUT
LED1+CONNECTION LED1-CONNECTION LED3+CONNECTION LED3-CONNECTION

4
Luminaire 1 Luminaire 2

SIGNALLING LED INDICATIONS ON THE GEAR BOX

PERIOD PULSES

FAULT DESCRIPTION

1

The encoded

faults are

5

based on pulses

emitted every

2

4 seconds 3

One or more active outputs is not working Undervoltage on one or more active outputs
short circuit on one or more active outputs One or more active outputs disconnection from load

4

Overload on one or more active outputs

AA BB CC
7 1 2 3 4

PRIORITY Maximum
Minimum

Recommended H07RNF 3G1,5 mm²
CABLE GLAND

TYPE M16 M25 M32

ØMin 5 mm 10 mm 13 mm

ØMax 10 mm 17 mm 21 mm

SEAL REDUCER for GB and FLOOD

TYPE

ØMin

ØMax

M32

10 mm

16 mm

96681048-05

11/2023

12

Mains (IN) M25
DMX (IN/OUT) M16

Output (OUT) M32

Floodlight

DMX (IN/OUT) M16

Max : 30 GB per line ­ 20 recommended- 200 M « DMX-RDM wiring shall respect ANSI E1.11 and AINSI E1.20 installation rules». 1 to 3 DMX addresses per GB ­ changeable via RDM Last device on the line shall be properly terminated with a 120R 0.5W 5% resistance (96683550)
AA BB CC

Mains (IN) 200/400V DMX
AA BB CC

96681048-05

DMX IN

DMX OUT DMX IN

11/2023

13 CONNECTION BOX ALTIS G5 3 x 1 Luminaire
2
2

Luminaire 3

Luminaire 1

1 3
4
Luminaire 2

Luminaire 2

RED BLACK GREY G / Y

LED+ LEDNTC

RED BLACK GREY G / Y

LED+ LEDNTC

Luminaire 1

RED BLACK GREY G / Y

LED+ LEDNTC

Luminaire 3

REF : PHOENIX CONTACT PRC 5 FC MS6 8-21 PHOENIX CONTACT PRC 5 FC MS6 8-21 HR

1

2

N

3

1 RED 2 BLACK 3 GREY
G / Y N NOT USED

96679580 ALTIS G5 CON 5P M+F 600V X1

96681048-05

11/2023

14 ELECTRICAL CONNECTION
Luminaire 2

Luminaire 3

T25 2Nm

Luminaire 1

Output side

ALG5 GB LE

ALG5 GB 3 CH

7 125634

100 10

Extreme caution : Do not connect any LED CONNECTION wire (high voltage) inside NTC connector !! It could result in a critical failure and damage irreversibly the ALTIS luminaire

G/Y 7* 1 2 5 6 3 4 G/Y 7* 1 2 5 6 3 4

50 mm

OK
Ø min = 1,0 mm² Ø typ = 1,5 mm² Ø max = 2,5 mm²

H 36 5 Nm

CABLE GLAND

TYPE

ØMin

ØMax

M32

13 mm

21 mm

Lenght max = 200 m

Lenght max = 200 m

Number 1 2 3 4
5 6 7

Label +1 -1 +3 -3
+2 -2 NTC GND GND

PINOUT
Description LED1+Connection LED1-Connection LED3+Connection LED3-Connection LED2+Connection LED2-Connection Thermal Measure INPUT PROTECTIVE EARTH PROTECTIVE EARTH
ALG5 GB 3 CH

Luminaire 1 Luminaire 3 Luminaire 2

ALG4 GB LE

96681048-05

11/2023

15 ALG5 GB 3 CH / ELECTRICAL CONNECTION / DALI

50

8

Mains (IN) M25
Signal LED

OK

Output (OUT) M32
Ventilation valve

Floodlight

DALI Re-launch (IN/OUT) M16

DALI (IN/OUT)

4

M16

2

1

7 125634

LP2rot:ectLivN1e/LE:oarrtLhL1/N/L2o/rLL31/L2/L3
3

19/30/36

Extreme caution : Do not connect any LED CONNECTION wire

LUM

(high voltage) inside NTC connector !! It could result in a critical

failure and damage irreversibly the ALTIS luminaire

Number

Label
L1 L2

DA+ DA+ DADA-
LUM

7

NTC

1

+1

2

-1

5

+2

6

-2

3

+3

4

-3

PINOUT
Description
AC LINE 1 INPUT AC LINE 2 INPUT PROTECTIVE EARTH
DALI INPUT DALI RE-LAUNCH
DALI INPUT DALI RE-LAUNCH
PROTECTIVE EARTH FOR LED MODULE
THERMAL MEASURE INPUT
LED1+CONNECTION LED1-CONNECTION LED2+CONNECTION LED2-CONNECTION LED3+CONNECTION LED3-CONNECTION

4
Luminaire 1 Luminaire 2 Luminaire 3

SIGNALLING LED INDICATIONS ON THE GEAR BOX

PERIOD
The encoded faults are
based on pulses emitted every 4 seconds

PULSES 1 5
2 3 4

FAULT DESCRIPTION
One or more CCR module enabled by config are not communicating with logic board Firmware version of one or more CCR module is not compatible with logic board firmware version One or more CCR's output is short-circuited
Load failure on one or more CCR's output
Thermal derating active (output current reduction)

PRIORITY Maximum
Minimum

DADA DADA
7 1 2 5 6 3 4

Recommended H07RNF 3G1,5 mm²

CABLE GLAND

TYPE M16 M25 M32

ØMin 5 mm 10 mm 13 mm

ØMax 10 mm 17 mm 21 mm

SEAL REDUCER for GB and FLOOD

TYPE

ØMin

ØMax

M32

10 mm

16 mm

96681048-05

11/2023

16 ALG5 GB 3 CH / ELECTRICAL CONNECTION / RDM-DMX

50

8

Mains (IN)
M25 Signal LED

OK

Output (OUT) M32
Ventilation valve

Floodlight

2

LP2rot:ectLivN1e/LE:oarrtLhL1/N/L2o/rLL31/L2/L3

L1 L2

A
A
B B S S

NTC +1 -1 +2 -2 +3 -3

4 1

DMX Re-launch (IN/OUT) M16
DMX (IN/OUT) M16
7 125634

3

19/30/36

Extreme caution : Do not connect any LED CONNECTION wire

(high voltage) inside NTC connector !! It could result in a critical failure and damage irreversibly the ALTIS luminaire

LUM

PINOUT

Number Label

Description

L1

AC LINE 1 INPUT

4

L2

AC LINE 2 INPUT

PROTECTIVE EARTH

A

DMX INPUT DATA+

A

DMX-RE-LAUNCH DATA+

B

DMX INPUT DATA-

B

DMX-RE-LAUNCH DATA-

S

DMX COMMON / SHIELD

S

DMX COMMON / SHIELD

LUM

PROTECTIVE EARTH FOR

LED MODULE

AA BB CC
7 1 2 5 6 3 4

7

NTC

1

+1

2

-1

5

+2

6

-2

3

+3

4

-3

THERMAL MEASURE INPUT
LED1+CONNECTION LED1-CONNECTION LED2+CONNECTION LED2-CONNECTION LED3+CONNECTION LED3-CONNECTION

Luminaire 1 Luminaire 2 Luminaire 3

Recommended H07RNF 3G1,5 mm²
CABLE GLAND

SIGNALLING LED INDICATIONS ON THE GEAR BOX

PERIOD
The encoded faults are
based on pulses emitted every 4 seconds

PULSES 1 5
2 3 4

FAULT DESCRIPTION
One or more CCR module enabled by config are not communicating with logic board Firmware version of one or more CCR module is not compatible with logic board firmware version One or more CCR's output is short-circuited
Load failure on one or more CCR's output
Thermal derating active (output current reduction)

PRIORITY Maximum
Minimum

TYPE M16 M25 M32

ØMin 5 mm 10 mm 13 mm

ØMax 10 mm 17 mm 21 mm

SEAL REDUCER for GB and FLOOD

TYPE

ØMin

ØMax

M32

10 mm

16 mm

96681048-05

11/2023

16A

Mains (IN) M25
DMX (IN/OUT) M16

Output (OUT) M32

Floodlight

DMX (IN/OUT) M16

Max : 30 GB per line ­ 20 recommended- 200 M « DMX-RDM wiring shall respect ANSI E1.11 and AINSI E1.20 installation rules». 1 to 3 DMX addresses per GB ­ changeable via RDM Last device on the line shall be properly terminated with a 120R 0.5W 5% resistance (96683550)
AA BB CC

Mains (IN) 200/400V DMX
AA BB CC

96681048-05

DMX IN

DMX OUT DMX IN

11/2023

17 ALG5 GB 3 CH MOUNTING

3 3

4
2 3 Nm

3

+1 -1 +2 -2 +3 -3
DA DA DA DA L1 L2

3

R4,25
8,5
Drilling recommendation:

L1 L2

DA DA DA DA

+1 -1 +2 -2 +3 -3

H36 5 Nm

H30 3 Nm

2x H19

1

2,5 Nm

10,5
480mm

10,5mm

134mm 4xØ8,5mm

HORIZONTAL

LATERAL / SIDE

VERTICAL

96681048-05

11/2023

18 ALG5 GB 3CH / 200-250 Vac - ALG5 GB 3 CH /250-440 Vac
CIRCUIT BREAKER recommendation It should mentioned in the notice that calculation has been done with a Circuit Breaker Load Factor of 100%.

V in Nominal
230Vac 400Vac

Inrush Current Data

I peak Half Value Type B Type B Type B Type B (A) Time (µs) 10A 16A 20A 25A

40

2500

0

1

1

2

68

2000

0

1

1

1

# Drivers for each Circuit Breaker

Type C Type C Type C Type C Type D Type D Type D Type D 10A 16A 20A 25A 10A 16A 20A 25A

0

1

1

2

0

1

1

2

1

1

2

2

1

1

2

3

GUIDELINE FOR INTEGRATION OF GEAR BOX

150 mm

70 mm

Tc reference hotspot

200 mm

To measure ambient temperature inside the cabinet it has to be done between 2 gear boxes

L L
L L
L L

200 mm

It is highly recommended to select a painted cabinet enclosure with highreflectance ratio to protect from solarradiant energy

If you cannot follow instructions included in previous section regarding gear box integration, you have to measure Tc reference point taking into consideration that measures must be down to Tc_max

Position

Tc Reference at Max Ambient

Horizontal

Vertical

Side

Tc

L

Mounting

96681048-05

230Vac 400Vac Ambient Max

81°C 69°C 55°C

L
80°C 68°C 55°C

This side up
82°C (Ref.) 70°C (Ref.) 55°C (Ref.)

11/2023

19 ALG5 GB LE / ELECTRICAL CONNECTION

50

8-9 mm

OK
Ø min = 1,0 mm² Ø typ = 1,5 mm² Ø max = 2,5 mm²

INPUT M25

T20
1

OUTPUT M25

Floodlight

Ventilation Valve

125634

2
30

Number
3 4 5 6 1 2

Label
L N PE PE NTC V3+ V3V2+ V2V1+ V1-

PINOUT

Description

AC INPUT

AC INPUT

PROTECTIVE EARTH

PE FOR LED MODULE

THERMAL PROTECTION FOR LED FIXTURE

DO NOT CONNECT

OUTPUT CHANNEL 3+

Luminaire 3

OUTPUT CHANNEL 3-

OUTPUT CHANNEL 2+ OUTPUT CHANNEL 2-

Luminaire 2

OUTPUT CHANNEL 1+ OUTPUT CHANNEL 1-

Luminaire 1

Recommended : H07RNF 3G1.5 mm²

L N PE

PE NC DA+ DA- NTC V3+ V3- V2+ V2- V1+ V1-

3 456 1 2

The wiring should follow label marking instruction, Otherwise the product could be damaged or the fonctions could be affected. Each set of + or - are not potential identical, cross connection is prohibited.

CABLE GLAND

TYPE M20 M25

ØMin 6.3 mm 10 mm

ØMax 11.3 mm 16.3 mm

96681048-05

11/2023

20 ALG5 GB LE MOUNTING
T20
2 1.6 Nm

1
H30 5 Nm
Plug 1Nm Optional cable 3.5 Nm

1 H30
5 Nm

Drilling recommendation:

480mm

10,5mm

134mm 4xØ8,5mm

HORIZONTAL

LATERAL / SIDE

VERTICAL

96681048-05

11/2023

21

Inrush

t

#

cuit e

T

T

T

T

T

T

T

T

T

T

T

No i

(A

10A 16A 20A 25A 32A 40A 63A 10A 16A 20A 25A

15 A 2000

0

1

1

1

2

25 A 2000

1

1

2

2

3

2

4

0

1

1

1

4

6

1

2

2

3

Inrush

t

No i

(A

T

TT

32A 40A 63A

15 A 2000

2

2

4

25 A 2000

4

5

8

T

T

T T

T

Position

Side

Tc

230 400
96681048-05

11/2023

22

Aiming Device

ALTIS LED AIMING DEVICE
UK Installation instructions DE Montageanleitung CZ Montázní návod DK Monteringsvejledning EE Paigaldusjuhend

FI Asennusohje FR Notice de montage HU Szerelési útmutató IT Istruzioni di montaggio LT Montavimo Instrukcijos

LV Instalacijas instrukcija NO Monteringsanvisning PL Instrukcja montazu SE Installationsanvisning RU

ALTIS LED AIMING DEVICE

Don't forget to switch off the aiming device between each setup.

2x Aiming device 2x Strap 2x Cleaning clotch 2x Lens caps 4x CR1620 battery 2x Allen wrench 2x Instruction leaflet

Aiming device should be attached with strap supplied in doing noose knot.

96671487 ALTIS G4/G5 AIMING DEVICE WITH VISOR 96671488 ALTIS G4/G5 AIMING DEVICE BRACKET

Louvres / Bird Deterrent

ALTIS LED

UK Installation instructions DE Montageanleitung CZ Montázní návod DK Monteringsvejledning EE Paigaldusjuhend

FI Asennusohje FR Notice de montage HU Szerelési útmutató IT Istruzioni di montaggio LT Montavimo Instrukcijos

TYPE : ALTIS LED G4/G5 ACCESSORIES

Louvre A4/A5/A6

LV Instalacijas instrukcija NO Monteringsanvisning PL Instrukcja montazu SE Installationsanvisning RU

Louvre A4/A5/A6/A6I
Louvre NB/EB/MB/WB

Louvre NB/EB/MB/WB

Bird Deterrent

Bird Deterrent

Visor
ALTIS LED

UK Installation instructions DE Montageanleitung CZ Montázní návod DK Monteringsvejledning EE Paigaldusjuhend

FI Asennusohje FR Notice de montage HU Szerelési útmutató IT Istruzioni di montaggio LT Montavimo Instrukcijos

TYPE : ALTIS G4/G5 ACCESSORIES

ALTIS G4/G5 VISOR

LV Instalacijas instrukcija NO Monteringsanvisning PL Instrukcja montazu SE Installationsanvisning RU

Visor G4/G5

96671492 ALTIS G4/G5 1 BRICK LOUVRE A4 96671493 ALTIS G4/G5 1 BRICK LOUVRE A5 96671494 ALTIS G4/G5 1 BRICK LOUVRE A6/A6I 96671496 ALTIS G4/G5 1 BRICK LOUVRE MB 96671495 ALTIS G4/G5 1 BRICK LOUVRE NB/EB 96671497 ALTIS G54/G 1 BRICK LOUVRE WB
96671489 ALTIS G4/G5 BIRD DETERRENT
96671498 ALTIS G4/G5 1 BRICK AJ VISOR

Power supply support
ALTIS LED

UK Installation instructions DE Montageanleitung CZ Montázní návod DK Monteringsvejledning EE Paigaldusjuhend

FI Asennusohje FR Notice de montage HU Szerelési útmutató IT Istruzioni di montaggio LT Montavimo Instrukcijos

TYPE : ALTIS G4/G5 ACCESSORIES

LV Instalacijas instrukcija NO Monteringsanvisning PL Instrukcja montazu SE Installationsanvisning RU

POWER SUPPLY SUPPORT

96671491 ALTIS G4/G5 GB BRACKET 2 BRICK LB STIRRUP

96681048-05

11/2023

FRANCAIS
-Remplacer toute protection fissurée. -Les luminaires classe II doivent être installés de façon à ce que la partie métallique ne soit pas en contact avec l'installation électrique connectée à la terre.
ATTENTION:Les luminaires classe I doivent être reliés à la terre. -Ce luminaire fonctionne à une tension nominale qui doit être coupée avant toute intervention sur l'appareillage. -Toute modification de cet appareil est interdite. -Respecter la distance minimale par rapport aux objets éclairés définie par ce sigle.
m

SVERIGE
-Ersätta alla spräckta skyddsplåtar. -Klass II armaturer måste installeras så att nakna metalldelar i armaturen inte är i kontakt med någon elektrisk installation,kopplad till en skyddledare.
VARNING:Klass I armaturer måste vara jordade. -Denna armatur fungerar med högspänning som måste vara frånslagen fore ingripande i driftdonen. -Alla ändringar i denna armatur är förbjuden.
m

ITALIANO
-Sostituire sempre tutte le protezioni danneggiate. -Gli apparecchi in classe II devono essere installati in modo che le parti metalliche non siano in contatto con apparati elettrici collegati a terra. ATTENZIONE:Gli apparecchi in class I devono essere collegati a terra. -Questo apparecchio funziona a tensione nominale,questa deve essere interrotta prima di ogni intervento sul gruppo di alimentazione. -Ogni modifica dell' apparechio à proibita.
m

ENGLISH
-Replace any cracked protective shield. -Class II luminaires must be installed so that exposed metal work of the luminaire is not in contact with any part of the electrical installation connected to a protective conductor. WARNING:Class I luminaires must be earthed. -This luminaire operates at mains voltage which must be switched off before intervention in control gear. -Any modification to this luminaire is forbidden. -Lighted objects nearer than the minimal distance in the is forbidden.
m

DEUTSCH
-Ersetze jede gebrochene Schutzscheibe. -Schutzklasse II Leuchten müssen so installiert werden,daß berührbare Metallteile nich mit einem,an dem Schutzleiter angeschlossenen Teil der elektrischen Installation in Kontakt kommen können. ACHTUNG:Schutzklasse I Leuchten müssen geerdet sein. -Diese Leuchte wird mit Netzspannung betrieben.Bevor Eingriffe am Vorschaltgerät vorgenommen werden sowie vor Wartung und Installation,ist die Versorgungsspannung abzuschalten. -Jede Änderung an dieser Leuchte ist verboten.
m

SUOMI
-Rikkoontunut suojalasi vaihdettava välittömästi uutsen vastaavaan. -Asennettaessa suojausluokan II valaisinta on peruseristetyn johdon ja kosketeltavien metalliosien välinen kosketus tehokkaasti eristettävä. VAROITUS: Suojausluokan I valaisin täytyy maadoittaa. -Verkkojännite on kytkettävä pois ennen valaisimen huoltotoimenpiteitä. -Valaisimen rakennetta el saa muuttaa.
m

Thorn Lighting is constantly developing and improving its products. The right is reserved to change specifications without prior notification or public announcement. © Thorn Lighting
- To ensure maintaining the best system performances, we advice to switch on the system "At least one night hour per month".
- corrosion environment from C1 to C5 according to standard ISO9223 except gear Box ALG4 GB LE corrosion environment from C1 to C3

96681048-05