User Manual for robuste models including: R2011 Versatile IoT Router with 5 Ethernet Ports, R2011, Versatile IoT Router with 5 Ethernet Ports, Versatile IoT Router, IoT Router, Router

Windows 用户

RT

R2011 Hardware Manual

R2011 Versatile IoT Router with 5 Ethernet Ports | Industrial Cellular Router | Robustel

Router IoT versátil R2011 con 5 puertos Ethernet | Robustel

Robustel R2011 Hardware Manual (RT070 HM R2011 V1.0.1)

Robustel produktblade, brugervejl. og kvikguide - M2M Nordic ApS


File Info : application/pdf, 12 Pages, 1.55MB

PDF preview unavailable. Download the PDF instead.

RT070 HM R2011 V1.0.1
Robustel R2011 Hardware Manual
R2011
Hardware Manual

Version: 1.0.1 Date: Nov. 28, 2022

RT070_HM_R2011

1/12

Robustel R2011 Hardware Manual

Regulatory and Type Approval Information Table 1: Toxic or Hazardous Substances or Elements with Defined Concentration Limits

Name of Hazardous Substances the Part (Pb) (Hg) (Cd)

(Cr(VI)) (PBB)

(PBDE) (DEHP) (BBP)

(DBP) (DIBP)

Metal

o

o

o

o

parts

-

-

-

-

-

-

Circuit

o

o

o

o

o

o

o

o

o

o

modules

Cables

and cable

o

o

o

o

o

o

o

o

o

o

assemblie

s

Plastic

and

o

o

o

o

o

o

o

o

o

o

polymeric

parts

o:

Indicates that this toxic or hazardous substance contained in all of the homogeneous materials for this part is

below the limit requirement in RoHS2.0.

X:

Indicates that this toxic or hazardous substance contained in at least one of the homogeneous materials for this

part might exceed the limit requirement in RoHS2.0.

-:

Indicates that it does not contain the toxic or hazardous substance.

Radio Specifications for Europe

RF technologies

2G, 3G, 4G, Wi-Fi

2G GSM: B3/B8

Cellular Frequency* Max RF power

3G WCDMA: B1/B8 4G LTE FDD: B1/B3/B7/B8/B20/B28A LTE-TDD: B38/B40/B41 33 dBm±2dB@GSM, 24 dBm+1/-3dB@WCDMA, 23 dBm±2dB@LTE, 18 dBm@Wi-Fi

* May vary on difference models.

RT070_HM_R2011

2/12

Robustel R2011 Hardware Manual
Caution: The user is cautioned that changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
This device contains licence-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic Development Canada's licence-exempt RSS(s) and Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause interference. (2) This device must accept any interference, including interference that may cause undesired operation of the device.
L'émetteur/récepteur exempt de licence contenu dans le présent appareil est conforme aux CNR d'Innovation, Sciences et Développement économique Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) L'appareil ne doit pas produire de brouillage; (2) L'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement.
Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: -- Reorient or relocate the receiving antenna. -- Increase the separation between the equipment and receiver. -- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -- Consult the dealer or an experienced radio/TV technician for help.
FCC& IC Radiation Exposure Statement This equipment complies with FCC and Canada radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20cm between the radiator and your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.
Déclaration d'IC sur l'exposition aux radiations Cet équipement est conforme aux limites d'exposition aux radiations définies par le Canada pour des environnements non contrôlés. Cet équipement doit être installé et utilisé à une distance minimum de 20 cm entre l'antenne et votre corps.
Cet émetteur ne doit pas être installé au même endroit ni utilisé avec une autre antenne ou un autre émetteur.

RT070_HM_R2011

3/12

Robustel R2011 Hardware Manual
Simplified EU Declaration of Conformity We, Guangzhou Robustel Co., Ltd. are located at 501, Building #2, 63 Yongan Road, Huangpu District, Guangzhou, China, declare that this radio equipment complies with all applicable EU directives. The full text of the EU DoC is available at the following internet address: www.robustel.com/certifications/
Safety Information General - The router generates radio frequency (RF) power. When using the router, care must be taken on safety issues related to RF interference as well as regulations of RF equipment. - Do not use your router in aircraft, hospitals, petrol stations or in places where using cellular products is prohibited. - Be sure that the router will not be interfering with nearby equipment. For example: pacemakers or medical equipment. The antenna of the router should be away from computers, office equipment, home appliance, etc. - An external antenna must be connected to the router for proper operation. Only uses approved antenna with the router. Please contact authorized distributor on finding an approved antenna.
RF exposure - This device meets the official requirements for exposure to radio waves. This device is designed and manufactured not to exceed the emission limits for exposure to radio frequency (RF) energy set by authorized agencies. - The device must be used with a minimum separation of 20 cm from a person's body to ensure compliance with RF exposure guidelines. Failure to observe these instructions could result in your RF exposure exceeding the applicable limits. Note: Some airlines may permit the use of cellular phones while the aircraft is on the ground and the door is open. Router may be used at this time.

The symbol indicates that the product should not be mixed with general household waste but must be sent to separate collection facilities for recovery and recycling.
The symbol indicates that the product meets the requirements of the applicable EU directives.

The symbol indicates that the product meets the requirements of the relevant UK legislation.
Related download link Find more product documents or tools at: www.robustel.com/en/documentations/

RT070_HM_R2011

4/12

Robustel R2011 Hardware Manual

Technical Support Tel: +86-20-82321505 Email: support@robustel.com Web: www.robustel.com

Document History Updates between document versions are cumulative. Therefore, the latest document version contains all updates made to previous versions.

Date July 6, 2022 Nov. 28, 2022

Firmware Version 5.0.0 5.0.0

Document Version 1.0.0 1.0.1

Change Description Initial release. Added declaration for product.

RT070_HM_R2011

5/12

Robustel R2011 Hardware Manual
Overview Robustel R2011 Industrial Cellular Router is a rugged, versatile 4G router with 5 Ethernet ports, dual SIM single standby capability and a range of advanced functions for mission critical IoT or M2M applications.
Package Checklist Before commencing installation ensure your package has the following components:

Device

2-PIN Terminal Block

Cellular Antenna

Wi-Fi Antenna

Ethernet Cable (Optional)

DIN rail Mounting Kit (Optional)

Wall mounting kit (Optional)

Power Supply (Optional)

Note: The accessories could be different on specific order. Panel Layout(May vary on difference models)

RT070_HM_R2011

6/12

Robustel R2011 Hardware Manual

Interface Descriptions

1. Power Supply. 2-pin 3.5 mm male terminal block

PIN

Description Note

1

V+

Positive

2

V-

Negative

Note: Voltage input range:9-36V

2. LED Indicator

Name

Color

Status

Description

RUN

Green

On, solid

Router is powered on (System is initializing)

On, blinking

Router starts operating

Off

Router is powered off

MDM

Green

On, solid

Successful link connection

On, blinking

Link connection is working

Off

Link connection is not working

Wi-Fi

Green

On, solid

Wi-Fi is working normally

Off

Wi-Fi is not working or abnormal

RSSI

Green

Three lights on

Signal Level: Best Signal Level

Wireless module: 21-31dB (signal strength)

Two lights on

Signal Level: Average Signal Level

Wireless module: 11-20dB (signal moderate)

One light on

Signal Level: Abnormal Signal Level

Wireless module: 21-31dB (signal weak)

Off

No signal

Note: You can choose the display type of USR LED. For more details, please refer to RT123_SM_RobustOS Software Manual, Services > Advanced > System >System Settings > User LED Type.

RT070_HM_R2011

7/12

Robustel R2011 Hardware Manual

3. Reset Button

Feature

Operation

Reboot

Press and hold the RST button for 2~ 5 seconds under the operating status.

Restore to default

Press and hold the RST button for 5~10 seconds, the RUN LED starts blinking quickly, the router will restore to default

configuration

configuration.

Restore to factory

Once the operation of restoring default configuration is performed twice within one minute, the router will restore to factory

default settings

default settings.

Note: The more details please refer to RT123_SM_RobustOS Software Manual, 2.3 Factory Reset.

4. Ethernet Ports. There are five Ethernet ports on R2011 Gateway, including ETH0 (WAN/LAN) and ETH1, ETH2, ETH3, ETH4. Each has two LED indicators. The green one is a link indicator but the yellow one doesn't mean anything. For details about status, see the table below.

Ethernet LED Indicator Status

Description

Link indicator

On, solid

Connection is established

(Green)

On, blinking

Data is being transferred

Off

Connection is not established

RT070_HM_R2011

8/12

Robustel R2011 Hardware Manual Hardware Installation 1. SIM Card Installation. Remove the SIM card cover to insert the SIM cards into the device, then screw up the cover.
2. Antenna Installation. Rotate the antenna into the antenna connector accordingly. Here take the cellular antenna as example.

RT070_HM_R2011

9/12

Robustel R2011 Hardware Manual 3. Mounting Kit installation.  Wall mounting
 DIN rail mounting
4. Power Supply installation. Insert the power supply cord into the corresponding terminal block if needed, then insert the terminal block into the power connector.

RT070_HM_R2011

10/12

Robustel R2011 Hardware Manual 5. Connect the Router to a Computer. Use a standard network cable to connect the Ethernet port of the router to a PC, when it is configured as 5 LAN, it can be connected to (ETH0~ETH4); when it is configured as 1 WAN+4 LAN, it can be connected to (ETH1~ETH4) ).
6. Grounding the Device. Grounding will help to prevent the noise effect due to electromagnetic interference (EMI). Connect the device to the site ground wire by the grounding screw before powering on.

RT070_HM_R2011

11/12

Robustel R2011 Hardware Manual
Login to the Device 1. Connect the router's Ethernet port to a PC with a
standard Ethernet cable.
2. Before logging in, manually configure the PC with a static IP address on the same subnet as the gateway address, click and configure "Use the following IP address".

5. After logging in, the home page of the web interface is displayed, then you can view system information and perform configuration on the device.

6. The automatic APN selection is ON by default, if need to specify your own APN, please go to the menu Interface->Link Manager->Link Setting->WWAN Settings to finish the specific setting.

3. To enter the gateway's web interface, type http://192.168.0.1 into the URL field of your Internet browser.

4. Use login information shown in the product label when prompted for authentication.

7. The more configuration details please refer to RT123_SM_RobustOS Software Manual. (END)

RT070_HM_R2011

Support: support@robustel.com Website: www.robustel.com
©2022 Guangzhou Robustel Co.,Ltd. All rights reserved. Subject to change without notice.
12/12

