User Manual for NEWCOSMOS models including: 807NLR, Natural Gas Alarm, 807NLR Natural Gas Alarm

AE Fowler

DANGER: EXPLOSION This Gas Alarm is designed to act as a continuous Gas ...

then call 911. Using the LoRa communications module, the Gas Alarm is designed to automatically send Gas Alarm-related information to your gas utility.

807NLR Natural Gas Alarm Manual

DeNova Detect 807NLR LoRaWAN Network Natural Gas Alarm


File Info : application/pdf, 5 Pages, 1.36MB

PDF preview unavailable. Download the PDF instead.

807nlr-wireless-natural-gas-alarm-owners-manual
DANGER: EXPLOSION

· Commercially available batteries will not work with the

New Cosmos USA, Inc. Natural Gas Alarm 807NLR

This Gas Alarm is designed to act as a continuous monitor of natural gas that reaches the sensor.

Gas Alarm. Contact your gas utility to arrange for replacement.

This Gas Alarm should not be used as a short-

· Keep out of reach of children.

term testing device to perform a onetime check · For indoor use only.

for the presence of natural gas, as plugging the

NOTICE

User's Manual

battery into the device in the presence of natural gas may cause an explosion.

This manual has been prepared for the 807NLR Gas Alarm ("Gas Alarm"). If you have a Gas Alarm installed in your

DANGER: FIRE AND EXPLOSION

house or building, you should read and understand the important instructions and warnings contained in this manual and retain a copy for future reference.

Improper disposal may result in fire or explosion. Contact your gas utility to arrange for disposal.

When natural gas, which consists primarily of methane, is

DANGER: HAZARDOUS CONDITIONS

· The Gas Alarm must only be installed by your gas utility or an authorized gas utility contractor.
· The Gas Alarm only detects natural gas. It does not detect carbon monoxide, fire, heat, smoke, flames, propane or any other gas.
· The Gas Alarm is not a substitute for proper installation, use, and maintenance of natural gas appliances and

present at concentrations of 10% or greater of the lower explosive limit (LEL) for methane, the Gas Alarm is designed to activate a gas leak alarm. The gas leak alarm consists of a flashing red LED light, an audible warning

Follow these instructions completely. Failure to do so may result in an undetected natural gas leak or other hazardous conditions that may cause

piping systems. The Gas Alarm does not prevent natural gas leaks from occurring, nor can it eliminate any existing natural gas leaks or problems.

sound (a loud beep), and a recorded message.

serious injury or death.

General Description and Intended Use

The Gas Alarm is equipped with a LoRa communications module designed to automatically send information directly

DANGER: HEARING DAMAGE

DANGER

to your gas utility. including information associated with gas Do not place your ear directly against or in close

leak alarm activation, Gas Alarm error, low battery, and end-of-service-life.

proximity to the Gas Alarm when it is alarming. Such exposure to the audible gas leak alarm may

DANGER: EXPLOSION, FIRE AND

damage your hearing.

ASPHYXIATION

WARNING

If you smell natural gas, evacuate the area immediately, then call 911. Do not wait for the gas
leak alarm to sound or for your gas utility to receive an automated notification.

Natural gas leak alarm indicates an emergency situation and risk of explosion.

· Do not change the Gas Alarm's installation position,

This Gas Alarm is designed to detect natural gas. Natural gas is a fossil fuel that is primarily made up of methane. It is

relocate it from where it is installed, or tamper with the Gas commonly used for cooking, home heating and water

· EVACUATE IMMEDIATELY and take others with Alarm or its battery.

heating. Natural gas is typically supplied through a gas

you.

· Do not block, cover, obstruct or paint over the Gas Alarm

· Do NOT use a phone, light a match, or turn on or or its sensor. The Gas Alarm can only detect natural gas

off any light switches, flashlights, or appliances. that reaches its sensor.

main and utility service line connected to your home. Natural gas is odorless and colorless, but has a chemical odorant (mercaptan) added to it to give it a distinct "rotten eggs" smell. Even odorized natural gas may not be

Doing so could IGNITE a FIRE or EXPLOSION. · Network or power outages may prevent your gas utility detected by smell in an unoccupied space, by an individual

· CALL 911 once you are safely outside the premises.

from receiving or processing automated notifications from with reduced sensitivity to smell, or in other situations.
your Gas Alarm, including notifications related to gas leak Natural gas is a highly flammable chemical compound. alarms. Always follow these instructions, without relying Although it happens rarely, a natural gas leak can occur

· Do NOT re-enter until told to do so by

on such automated notifications.

inside a house or building. This can be dangerous because

authorities.
DANGER: ELECTROCUTION Do not subject the Gas Alarm to water or liquid by submerging it, spraying liquid on it or otherwise. Do not disassemble.

· This Gas Alarm will reach its end-of-service-life in approximately 7 years from the date of installation. Contact your gas utility for replacement if you observe the end-of-service-life alarm indicator LED.
· Do not modify, disassemble, submerge, strike, crush, or expose the Gas Alarm to high levels of volatile organic

it increases risk of explosion and fire. The Gas Alarm is designed to activate a gas leak alarm when it detects 10% or greater of the LEL for methane, which is 0.5% or greater of methane in air. When the gas leak alarm activates, the Gas Alarm will beep 4 times and state "Danger ­ gas leak explosion risk ­ evacuate, then call 911."
In the event of a gas leak, you may smell natural gas before

compounds. Doing so may cause the Gas Alarm to malfunction.

the gas leak alarm is activated. If you smell natural gas at any time, do not wait for the gas leak alarm to sound or check for Gas Alarm malfunction. Evacuate immediately,

then call 911.

Gas Alarm functions

Using the LoRa communications module, the Gas Alarm is designed to automatically send Gas Alarm-related information to your gas utility. When natural gas is detected at or above the gas leak alarm threshold, the Gas Alarm is designed to transmit a gas leak alarm notification to your gas utility. The Gas Alarm is also designed to send information about device health to your gas utility during automated health checks performed every 24 hours.
The Gas Alarm is not guaranteed to prevent personal

The Gas Alarm is designed to activate an audible gas leak

DANGER: EXPLOSION RISK

alarm in the event of a natural gas leak, and a silent alarm
with visual LED indicators in the event of a Gas Alarm error, Do not reset the Gas Alarm after the gas leak

a low-battery condition, and when the Gas Alarm reaches alarm goes off, unless instructed to do so by

its end-of-service-life. The LoRa communications module is also designed to send an automated notification to your gas utility when any of these alarms activate.
Natural gas leak alarm activation

emergency personnel. Resetting process can
cause an explosion if conducted in an area with high concentrations of natural gas.

injuries or property damage associated with a gas leak. For

Emergency responders or trained personnel may reset or

example, an error may occur that prevents detection of

The Gas Alarm is designed to activate a gas leak alarm

instruct you to reset the Gas Alarm by removing and

natural gas, including gas leaks. Network or power outages when it detects natural gas at a concentration that reaches reinstalling the battery. After removing the battery, hold the

may prevent your gas utility from receiving or processing or exceeds 10% of the LEL for methane. When activated, test button for at least 10 seconds and leave the battery

automated notifications from your Gas Alarm, including

the gas leak alarm is designed to:

unplugged for at least 2 minutes. This will reset the device

notifications related to gas leak alarms. Some people may Beep 4 times and state "Danger ­ gas leak explosion sleep through and not hear the audible gas leak alarm. You risk ­ evacuate, then call 911." This notification will

by turning off auditory and visual notifications.

should ensure that your natural gas appliances and piping systems are properly installed, used, and maintained to reduce the likelihood of a natural gas leak.
Gas Alarm parts

repeat every 6 seconds for 4 minutes, and then every 1 minute thereafter.

Error alarm activation

Send a gas leak alarm notification to your gas utility via

An alarm indicates a Gas Alarm error by flashing the Yellow LED light (trouble) three times every 10 seconds, and an alarm will

the LoRa communications module every 30 seconds. sound every 60 seconds, beep 3 times and state "Detector Error"

Flash the Red LED light once every 2 seconds.

followed by 3 additional beeps and state "Error del detector". When this alarm activates, a Gas Alarm error notification is

 Green LED (Power)
This LED flashes when the test button is pressed.
 Alarm speaker
Sounds an alarm when natural gas is present.
 Red LED (Gas leak alarm)
This LED flashes when gas is detected.
 Production serial number label

 Internal gas sensor

An alarm sounds every 6 seconds stating "Beep Beep Beep Beep Danger ­ gas leak explosion risk ­ evacuate, then call 911."

 Yellow LED (trouble)
This LED flashes when trouble occurs, when the battery is low, or when the end of service life has been reached.
 Test button

Transmits gas leak alarm signals every 30 seconds. Red LED (gas leak alarm) Flashes once every 2 seconds
DANGER: EXPLOSION, FIRE AND ASPHYXIATION

Follow these instructions carefully in the event

transmitted to your gas utility during the every-24-hour device health check.
Transmits Gas Alarm error notifications during the health checks performed every 24 hours.
Yellow LED (trouble) Flashes 3 times every 10 seconds
Low-battery alarm activation
NOTICE
The Gas Alarm uses a specialized battery not available at retail. Contact your gas utility to arrange

that the natural gas leak alarm activates. Never for replacement.

ignore any natural gas leak alarms. EVACUATE IMMEDIATELY and take others with you.
Do NOT use a phone, light a match, or turn on or

An alarm indicates low battery by flashing the Yellow LED light (trouble) once every ten seconds, and an alarm will sound every 60 seconds, beep 1 time and state "low battery" followed by an additional beep and state "Batería baja". If you observe the lowbattery alarm indicator LED, contact your gas utility to arrange for

 MACID label

off any light switches, flashlights, or appliances. Doing so could IGNITE a FIRE or EXPLOSION.
CALL 911 once you are safely outside the premises.

replacement. When this alarm activates, a low-battery notification is transmitted
to your gas utility during the every-24-hour device health check.
Transmits a low battery notification during the health checks performed every 24

Do NOT re-enter until told to do so by authorities.

hours. The battery in this device is not available in retail. Contact your gas utility to arrange for

Yellow LED (trouble) replacement.

Flashes once every 10 seconds

Specifications

End-of-service-life alarm activation
An alarm indicates the end of the Gas Alarm's service life by flashing the Yellow LED light (trouble) twice every ten seconds, and an alarm will sound every 60 seconds, beep 2 times and state "Please Replace Detector" followed by 2 additional beeps and state "Por favor, reemplace el detector". If you observe the end-ofservice-life alarm indicator LED, contact your gas utility to arrange for replacement. When this alarm activates, an end-of-service-life notification is transmitted to your gas utility during the every-24-hour device health check.

Conforming standards
Detection principle
Target gas
Sensor immunity
Operating temperature range

Operating

humidity range

Transmits an end-of-service-life

Power supply

notification during the health

Alarm level

checks performed every 24 hours.

Sound Output

Initial power-up

timer

Yellow LED (trouble) Flashes twice every 10 seconds

Weight and dimensions

Cleaning

End-product compliant with UL 1484, MEMS sensor is listed with UL 2075
MEMS hot wire semiconductor sensor Methane gas (natural gas) Acetone, ethanol, bleach solution, among others 32°F (0°C) to 122°F (50°C)
5% to 95%, no condensation 3V Lithium Battery 10%LEL 85dB at 10 feet Approx. 30 seconds (green LED flashes once every second) Approx. 170g, W 85 x H 115 x D 28mm (excluding protrusions)

WARNING

Dirt and dust can cause the Gas Alarm to malfunction. Follow these instructions to maintain proper operation.

If you observe dirt or dust accumulating on the Gas Alarm, contact your gas utility to arrange for the Gas Alarm to be cleaned. As an alternative, you can clean the Gas Alarm, as needed, by gently vacuuming the exterior of the unit including all slotted openings using a household vacuum's soft brush attachment.
Never use water, cleaners or solvents since they may damage the unit.
Do not use spray cleaning chemicals, pesticides, or insect sprays directly on or near the Gas Alarm. Do not use any household cleaning agents, ammonia-based cleaners, paints, varnishes, aerosol sprays (including compressed gas dusters), or any other chemical on or near this Gas Alarm.

Contact Details
New Cosmos USA, Inc. 650 Warrenville Rd, Suite 101 Lisle, IL 60532 Tel: (847)-749-3064

Green LED Yellow LED

New Cosmos USA, Inc. Natural Gas Alarm 807NLR

Testing gas leak alarm notifications
Press test button until you hear a "Beep" sound, then continue to hold until you hear a "Beep Beep" sound approximately 5 seconds later. Release within 10 seconds

Communications test mode activated
1st press: normal communication

Flashes 3x Off per second
Flashes 2x Off per second

Troubleshooting Guide

of pressing the test button.

2nd press: proper

Flashes 2x Flashes 3x

This Gas Alarm is designed to be troubleshot exclusively by authorized professionals. This guide is intended for professional use only.

Red LED (alarm) Flashes once every
 second

"Beep" "Beep Beep" When the button is
Released "Beep Beep Beep Beep Danger ­ Gas leak explosion risk -
evacuate, the call 911."

transmission of device error signal
3rd press: proper transmission of low battery signal

per second
Flashes 2x per second

per second
Flashes 2x per second

Testing the detector

Will sound twice.

If the red LED light activates or the alarm sounds

· CAUTION
If the Gas Alarm does not operate properly, it cannot alert the presence of natural gas. Take immediate action if the Gas Alarm fails a test.
Testing power

during any of these tests, the detector's

communication functions are not working properly.

If the Gas Alarm is operating properly, the red LED will flash once every 2 seconds for a 12 second period, and the following alarm message will sound twice: "Beep Beep Beep Beep Danger ­ gas leak explosion risk ­ evacuate, then call 911."

Additional presses will cycle you back through these three tests for as long as you are in communications test mode. Communications test mode will automatically end after 5 minutes.

Testing automated communications

Troubleshooting

Press and hold test button for at least 10 seconds, until you

Press test button until you hear a "Beep" sound, then quickly release (within 3 seconds after pressing the test button). If the device is properly powered, the green LED will flash twice every second (for 3 seconds) to indicate that the power is on.

have heard a single "Beep" followed by a double beep ("Beep Beep") followed by a triple beep ("Beep Beep Beep"). This will enable communications test mode, and the green LED will flash 3 times per second for as long as you are in communications test mode.

Symptom
The green LED does not flash even when the switch is pressed

Cause
Battery connector not plugged in completely

Action
Plug in the battery connector completely

"Beep"

"Beep" "Beep Beep" "Beep Beep Beep"

Battery is low

Replace the battery

Green LED (power) Flashes twice every
second(for  seconds)

Green LED (power) Flashes 3 times every second

The signals in the following table are transmitted

The yellow LED is flashing.

Flashes twice every 10 seconds:
End of service life

Replace the detector

Once in communications test mode, press the test button additional times to test whether the detector is communicating normally with your gas utility's systems, able to properly transmit detector error signals, and able to properly transmit a low battery signal. Success will be indicated as follows:

Flashes once every 10 seconds:
Low battery
Flashes 3 times every 10 seconds: Gas Alarm trouble

Replace the battery
Replace the detector

New Cosmos USA, Inc. Natural Gas Alarm

or humidity such as a sink, cooktop, dishwasher or a shower. · Next to a door or window.
· Next to a ventilation fan.

To remove the battery cover, push down at the indicated points with your thumbs and side the cover in the direction of the arrow.

807NLR

· Near a room return or HVAC duct. · In an area where the temperature will

Professional Installation Guide

drop below 32°F (0°C) or exceed 122°F (50°C).
· In an area that is dusty or dirty.

This Gas Alarm is designed to ·

In an area where organic solvents exist or silicone vapors.

be installed and cleaned

· In a damp or very humid location, such

exclusively by authorized professionals. Users should not install or clean the gas

as a bathroom. · Outside.
Installing the battery

· Connect the included lithium battery by inserting the battery harness connector into the product as shown in the diagram

alarm themselves. This guide is intended for professional use

DANGER ­ SHOCK

below. Do NOT remove the plastic wrap surrounding the battery pack.

only.

Do NOT remove the plastic wrap

Selecting location for

surrounding the battery pack. Doing so may cause electrical short or

installation

shock.

NOTICE

NOTICE

· Installation in an improper location can affect the sensitive electronic components in this Gas Alarm.
· Improper placement can prevent

Gas Alarm uses type of battery that is not available in retail. Contact
your gas utility if replacement battery needed.

detection of methane.

After installing battery, test the Gas

· Place out of reach of children.

Alarm following instructions in Troubleshooting Guide.

Gas Alarm should be installed by attaching it

to a pipe or, if a suitable pipe is unavailable, To reinstall the included battery or

to a location on a wall that is:

install a new battery you received from

· Between 4 to 12 inches (0.1 to 0.3

your gas utility:

meters) from the ceiling.

· Open the battery cover on the back of

· In an area where it will not be impeded the detector. This cover slides out of

by items hanging from or near the

place. To open, place both thumbs on

ceiling such as curtains, drapes, ceiling the back of the battery cover where the

fans.

battery cover hooks snap into place.

· ·

At least 5 feet (1.5 meters) from cooking appliance or cooktop hood.
At least 10 feet (3 meters) from gas appliances.

·

Push down where the battery cover snaps into place with your thumbs and slide the cover out. Some force is required.

Gas Alarm should NOT be installed:

· In the peak of a cathedral ceiling. · Directly above or near sources of water

· The battery connector has a large notch on it that faces up when installed correctly. There is only one way in which the connector can be installed. A small portion of the connector will be exposed when connected properly.
Mounting the Gas Alarm
NOTICE
After mounting the Gas Alarm, test it following instructions in Troubleshooting Guide.
If possible, mount the Gas Alarm to a pipe meeting the criteria discussed in the "Selecting location for installation" section. To mount to a pipe:
(1) Pass a cable tie through the hole at the top of the Gas Alarm.

(2) Wrap the cable tie around the pipe and tie off.
If mounting to a pipe is not feasible, mount the detector to a wall. (1) Choose a location on the wall
between 4 inches (0.1 meters) to 12 inches (0.3 meters) from the ceiling. Make a mark in the Mounting Tab of the Gas Alarm where you will drill the mounting hole. (2) Use a 3/16" (5 mm) drill bit to drill the mounting hole and insert included anchor. (3) Tighten the screw into the anchor until the screwhead is about 3/16 inch (5 mm) away from the wall, leaving enough space for the Mounting Tab. (4) Hang the Mounting Tab on the screw.
Mounting Tab
screw
(5) Lightly tighten the screw to secure the Gas Alarm.


Microsoft Word for Microsoft 365