FSP FSP120-AxxN3 Series 120W Adapter
Technical Datasheet
Key Features
- Certified IEC 62368-1 & CB 60950-1
- Meets USA EISA 2007
- Meets Energy Efficiency DOE Level VI
- Meets Code of Conduct Version 5 Tier 2
- High Reliability
- Low Profile
- Over Current Protection
- Over Temperature Protection
- Over Voltage Protection
- With PFC Circuit
Safety Standard Approvals
TÜV Rheinland Certified, cULus Listed, CE, FCC Tested to Comply With FCC Standards FOR HOME OR OFFICE USE, CCC.
Product Description
This 120-watt AC to DC adapter is designed for use in IPC systems, embedded systems, printers, monitors, POS systems, and PoE applications that have high wattage demands. The adapter operates at 90 to 264 VAC input voltage. It meets CISPR32 EN55032 CLASS B, EN55024, and FCC PART 15B Class B emission limits, and is designed for ITE (Information Technology Equipment) applications.
Input Specifications
Parameter | Value |
---|---|
Input voltage | 90-264 VAC |
Input frequency | 47-63 Hz |
Input current | 100Vac, 240Vac / full load ≤ 1.2A |
No load power consumption | 115Vac, 230Vac ≤ 0.5W |
Touch current | 264Vac / 50Hz ≤ 0.25mA |
Input Performance Specifications
Parameter | Value |
---|---|
Power factor | 115Vac, 230Vac / full load ≥ 0.9 |
Harmonic reduction | Provisions for adding harmonic reduction per EN 61000-3-2 must be present. |
Efficiency | See rating chart |
Power turn-on time | At 100Vac / full load, output voltage shall remain regulation ≤ 3Sec |
Hold-up time | At 100Vac or 240Vac / full load, output voltage shall remain regulation ≥ 10ms |
Inrush current | 100Vac, 240Vac / full load, Shall be less than the rating of adapter critical component (including rectifiers, fuse, surge and current limiting device) |
Operating altitude | 5000 meters above sea level |
Withstand voltage | Between AC input and secondary applied DC 4242V, test time 1 minute, cut off current shall be less than 10mA |
MTBF | 100Vac, 240Vac / full load, 300,000 hours at 25°C, standard SR332 |
EMC Performance
Standard | Performance |
---|---|
EN55032 | Class B conducted, class B radiated |
FCC | Class B conducted, class B radiated |
VCCI | Class B conducted, class B radiated |
EN61000-3-2 | Meet class D |
EN61000-3-3 | Meet regulation |
EN61000-4-2 | Air discharge: ±15 KV, contact discharge: ±8KV, meet criterion A |
EN61000-4-3 | 80~1000 MHz, 3V/m, 80% AM(1kHz), meet criterion A |
EN61000-4-4 | Impulse: ±1kV applied to L, N, meet criterion A |
EN61000-4-5 | ±1kV applied differential mode, ±2kV applied common mode, meet criterion A |
EN61000-4-6 | 0.15~80 MHz, 3Vrms, 80% AM(1kHz), meet criterion A |
EN61000-4-8 | 50 Hz or 60Hz, 1A/m, meet criterion A |
EN61000-4-11 | Voltage Dips: >95% reduction for 0.5 period, meet criterion B; 30% reduction for 25 period, meet criterion C; Voltage Interruptions: >95% reduction for 250 period, meet criterion C |
Output Specifications
Parameter | Value |
---|---|
Total output power | 120W |
Over voltage protection | The adapter will enter into shut down if over voltage occurs at the output terminal due to an internal fault. Output trip voltage shall not exceed 19/29/35/63/65* volts. Normal state is restored by AC reset. |
Short circuit & Over current protection | When an internal fault or external fault (overload or short circuit) is applied to the output, the power supply shall shut down and enter auto-recovery mode. |
Over temperature protection | The power supply will enter into shut down when abnormal thermal rise occurs. Normal state is restored by AC reset. Set at 60Vac~70Vac. |
Notes: *Volts express by order of 120-AHxN3/ABxN3/ AAxN3 / AFxN3/ AWxN3
Environmental Specifications
Parameter | Value |
---|---|
Working Temperature | 0~70°C (de-rating required above 40°C) |
Storage Temperature | -20~+80°C |
Working Humidity | 20~80% RH non-condensing |
Storage Humidity | 10~90% RH non-condensing |
Performance Curves
Output Voltage/Current Rating Chart
Model | Output Voltage | Output Current | AC Inlet | Efficiency (DOE Level VI) | Efficiency (CoC V5, Tier 2) | Over Voltage Protection |
---|---|---|---|---|---|---|
FSP120-AHAN3 | 12V | 10A | C14 | ≥88% | ≥89% | 19 Volts |
FSP120-AHBN3 | 12V | 10A | C6 | 19 Volts | ||
FSP120-ABAN3 | 19V | 6.32A | C14 | 29 Volts | ||
FSP120-ABBN3 | 19V | 6.32A | C6 | 29 Volts | ||
FSP120-AAAN3 | 24V | 5A | C14 | ≥88% | ≥89% | 35 Volts |
FSP120-AABN3 | 24V | 5A | C6 | 35 Volts | ||
FSP120-AFAN3 | 48V | 2.5A | C14 | ≥88% | ≥89% | 63 Volts |
FSP120-AFBN3 | 48V | 2.5A | C6 | 63 Volts | ||
FSP120-AWAN3 | 54V | 2.22A | C14 | ≥88% | ≥89% | 65 Volts |
FSP120-AWBN3 | 54V | 2.22A | C6 | 65 Volts |
Mechanical Specifications
The adapter is available in different models with specific mechanical configurations. Dimensions are provided for reference.
FSP120-AxAN3 Series
Overall dimensions are approximately 151.3 mm (Length) x 75.6 mm (Width) x 40 mm (Height). The output cable length is 1500 mm ± 50 mm. The plug type is specified as 皇積 5525TVM250-1T00-02 OR EQUIVALENT. A cable tie made of steel wire, PE plated, is used.
FSP120-AxBN3 Series
Overall dimensions are approximately 151.3 mm (Length) x 75.6 mm (Width) x 40 mm (Height). The output cable length is 1500 mm ± 50 mm. The plug type is specified as 皇積 5525TVM250-1T00-02 OR EQUIVALENT. A cable tie made of steel wire, PE plated, is used.
Connector Specifications
The adapter features specific connector configurations. Detail X shows a connector with a 2.5 mm ± 0.1 mm diameter pin and a 5.5 mm ± 0.05 mm outer diameter. The cable is approximately 1500 mm ± 50 mm long. Connectors are marked with High-Temperature (H.S.) tubes: RED (+) and BLACK (-). A cable tie made of steel wire, PE plated, is used.