Installation Guide for Corelite models including: SQ2 Indirect Wall Mounted Linear, SQ2, Indirect Wall Mounted Linear, Wall Mounted Linear, Linear
7 sept. 2024 — Risk of Fire, Electrical Shock, Cuts or other Casualty Hazards- Installation and maintenance of this product must be performed by a qualified electrician.
Remove dust cover from fixtures to access joiner aligner (Figure 9). Bend up sheet metal tabs and pull wire and connectors up as shown. Insert and fasten the ...
File Info : application/pdf, 10 Pages, 1.52MB
DocumentDocumentIL52473324ML Installation Instructions - Corelite SQ2 Wall ICNSo# relite WARNING Risk of Fire, Electrical Shock, Cuts or other Casualty Hazards- Installation and maintenance of this product must be performed by a qualified electrician. This product must be installed in accordance with the applicable installation code by a person familiar with the construction and operation of the product and hazards involved. Risk of Fire and Electric Shock- Make certain power is OFF before starting installation or attempting any maintenance. Disconnect power at fuse or circuit breaker. Risk of Fire- Minimum 90°C supply conductors. Risk of Burn- Disconnect power and allow fixture to cool before handling or servicing. Risk of Personal Injury- Due to sharp edges, handle with care. Risk of Personal Injury- Do not install this product in locations such as gymnasiums, arenas, sports complexes, multi-purpose rooms and other locations where the fixture potentially will be subject to impacts from externalnsources. Doing so may result in cracking and/or breaking of the fixture which may cause pieces to fall from the application. Failure to comply with these instructions may result in death, serious bodily injury and property damage. DISCLAIMER OF LIABILITY: Cooper Lighting Solutions assumes no liability for damages or losses of any kind that may arise from the improper, careless, or negligent installation, handling or use of this product. IMPORTANT: Read carefully before installing fixture. Retain for future reference. CAUTION: Fixture may become damaged and/or unstable if not installed properly. Note: Specifications and dimensions subject to change without notice. Note: These instructions do not claim to cover all details or variations in the equipment, procedure or process described, nor to provide directions for every possible contingency during installation, operation, or maintenance. When additional information is desired to satisfy a problem not covered sufficiently for user purpose, please contact your nearest representative. ATTENTION Receiving Department: Note actual fixture description of any shortage or noticeable damage on delivery receipt. File claim for common carrier (LTL) directly with carrier. Claims for concealed damage must be filed within 15 days of delivery. All damaged material, complete with original packing must be retained. Wiring Table Power Supply (Input) Black (BK) - Hot White (WT) - Neutral Green (GN) - Ground Violet (VT) - Dimming (+) Pink (PK) - Dimming (-) Power Supply (Input) - When Applicable Black/Red (BK/RD) - Emergency Hot White/Red (WT/RD) - Emergency Neutral Black/Orange (BK/OR) - 2nd Circuit Hot White/Orange (WT/OR) - 2nd Circuit Neutral Orange (OR) - 2nd Circuit Dimming (+) Yellow (YL) - 2nd Circuit Dimming (-) Vivid Tune Blue (BL) - Battery/Emergency Unswitched Hot Violet/White (VT/WT) - 1st Circuit CCT (+) Gray/Black (GY/BK) - 1st Circuit CCT (-) Black/White (BK/WT) - 2nd Circuit CCT (+) White/Yellow - 2nd Circuit CCT (-) Lighting Solutions Installation Instructions Continua, SQ,2 Wall Mount INSTALLATION Wall Brackets 4 x Holes for Mounting to Structure (if required) 6 x Holes for Mounting to Structure (if required) Individual/End of Run Wall Bracket Continuous Mount Wall Bracket Figure 1. Slots for Junction Box Mounting A horizontal 2x4 j-box is required at the right hand side of the fixture or run for power connection (Figure 2.) Structural Stud (By Others) Drywall (By Others) Structural Stud (By Others) Drywall (By Others) Individual Mount Wall Bracket Junction Box Hardware (By Others) 2 x 4 Junction Box (By Others) Attach Non Power Bracket to Stud with Appropriate Hardware(By Others) Figure 2. Figure 3. Mount subsequent wall brackets, level with the first, at the recommended spacing (See Table A) Brackets should be mounted to structure with appropriate hardware (by others) 2 Installation Instructions - Corelite SQ2 Wall IL52453823ML www.cooperlighting.com Installation Instructions Continua, SQ2 Wall Mount Mount Spacing 24.00 A Continua SQ Wall Figure 4. See Table A for Bracket Spacing Align Bracket Edge with Center of Stud Figure 5. Fixture length Table A 2 ft 4 ft 6 ft 8 ft A A Align Continuous Mount Bracket Center Holes with Centeline of Stud Align Bracket Edge with Center of Stud See Table A for Bracket Spacing A 24" 48" 72" 96" Installation Instructions - Corelite SQ2 Wall 3 IL52453823ML www.cooperlighting.com Fixture Installation Installation Instructions Continua, SQ,2 Wall Mount Figure 6. Hang first fixture from the installed brackets by hooking the flange on the fixture side bracket into the lower flange on the wall side bracket. Pull wires from the junction box and into the wiring hole on the fixture. Pull wires from fixture and supply wires out of the end of the fixture and attach using suitable connectors(by others) (figure 6,7, 8) 1. Figure 7. 4 2. 3. Installation Instructions - Corelite SQ2 Wall IL52453823ML www.cooperlighting.com 1. Hook fixture on bottom of bracket 2. Rotate fixture to horizontal and engage tabs into bracket 3. Secure bracket using #8 screw provided Figure 8. Installation Instructions Continua, SQ2 Wall Mount Joining Remove dust cover from fixtures to access joiner aligner (Figure 9) Bend up Sheet Metal Tab and Make Wire Connectors Accessible Figure 9. Connectors Installed on Non-power End of Fixture Insert Fixture Joiners as shown and Screw into Channel with Provided Fasteners Figure 10. Bend up sheet metal tabs and pull wire and connectors up as shown. Insert and fasten the provided fixture joiners as shown (Figure 10.) Installation Instructions - Corelite SQ2 Wall 5 IL52453823ML www.cooperlighting.com Joining (Continued) Hang next fixture from Double Wall Bracket but do not secure with screw Installation Instructions Continua, SQ,2 Wall Mount Make Wire Connections using provided Push Nuts Connect wires using the provided wire connectors, push all wire back into fixture. (Figure 11.) Push Fixtures Firmly Together and Insert and Tighten Provided #8 Screw Figure 11. Firmly Attach Joiners to extrusion with Provided Fasteners as shown. Figure 12. Push fixtures together and secure with provided hardware Minor Left to Right Adjustment Possible. Bend tabs back to original position (Figure 12.) 6 Installation Instructions - Corelite SQ2 Wall IL52453823ML www.cooperlighting.com Installation Instructions Continua, SQ2 Wall Mount Lens Cut Lens 0.5 inches from the end of the fixture Figure 13. Insert the end of the roll in lens and push lens through the fixture run until it impacts the far end endcap. Cut the lens with sharp scissors a minimum of 0.5" past the end of the fixture. (Figure 13.) End Cap Bend tab up Slide Endcap onto Joiner aligners Secure Encap with provided hardware Figure 14. Attach joiners to the extrusion, slide decorative end cap onto joiners and fasten with provided hex head screws. (Figure 14.) Replace dust cover Insert Dust Cover Tabs into Slots Figure 15. Rotate Dust Cover Into Extrusion Channel Installation Instructions - Corelite SQ2 Wall 7 IL52453823ML www.cooperlighting.com 7 6 5 Addendum for joining Discreet fixtures. Installation Instructions Continua, SQ,2 Wall Mount 4 3 2 1 REVISIONS REV. DESCRIPTION DATE CHANGE_NUMBER BY APPROVED F E D C 7 6 5 4 3 2 REVISIONS REV. DESCRIPTION DATE CHA B Step 1 - Remove baffles from ends of both fixtures. Secure first fixture to wall bracket. CLD-QTL-wall install L-ES-1025. URE THAT IS NOT DIMENSIONED IN THE DRAWING CAN BE EXTRACTED FROM THE MODEL AND IS SUBJECT TO THE 2PL. TOLERANCE. ROPRIETARY /OR TECHNICAL INFORMATION ONTAINED THEREON, IS CONFIDENTIAL AND IS THE EXCLUSIVE PROPERTY OF COOPER LIGHTING SOLUTIONS, AND IS MERELY ON LOAN AND SUBJECT TO RECALL BY COOPER LIGHTING SOLUTIONS AT PIENT ACKNOWLEDGES AND AGREES THAT THIS DOCUMENT CANNOT BE USED IN ANY MANNER ADVERSE TO THE INTERESTS OF COOPER LIGHTING SOLUTIONS, AND THAT NO PORTION OF THIS OUT THE PRIOR WRITTEN CONSENT OF COOPER LIGHTING SOLUTIONS. IN THE CASE OF CONFLICTING CONTRACTUAL PROVISIONS, THIS NOTICE SHALL GOVERN THE STATUS OF THIS DOCUMENT. 7 6 5 4 MATERIAL MASTER 3 Cooper Lighting SolutionsTemplate Rev A ELECTRONIC CAD DRAWING. DO NOT REVISE MANUALLY. DIMENSIONS ARE IN INCHES DIMENSIONS THAT AFFECT DENOTES CRITICAL S SAFE HANDLING OR OPERATION C DIMENSIONS AND GAUGE CHECK POINTS DENOTES FIRST PIECE P AND IN-PROCESS INSPECTION DENOTES FIRST F PIECE INSPECTION ONLY DIMENSIONS IN [ ] ARE IN MM TOLERANCE GENERAL SHEET METAL APPROVALS DATE ENGLISH (IN) METRIC (MM) ANGLES .X .XX .XXX .X .XX .XXX ALL 0.030 0.010 0.005 0.75 0.25 0.12 .XX .XXX .XX .XXX 1.0 0.030 0.015 0.75 DRWN: 0.38 CHKD: Denver, CO A SAP VERSION: THIRD ANGLE PROJECTION APPR: TITLE: x.x L MOD: 670246807 9/13/2023 x.x MATERIAL: FINISH: SIZE: DWG NO:Draw3 REV: D - DO NOT SCALE DRAWING SURFACE AREA:6158.885 IN2 2 SCALE: WT: 21.320 LB 1 VOL: 266.326 IN3 SHEET 1 OF 1 IP LEVEL: Step 2 - Hang 2nd fixture and make electrical connections between the two. 8 Installation Instructions - Corelite SQ2 Wall IL52453823ML www.cooperlighting.com ELECTRONIC CAD DRAWING. DO NOT REVISE MANUALLY. DIMENSIONS ARE IN INCHES DIMENSIONS IN [ ] ARE IN MM TOLERANCE GENERAL SHEET METAL ENGLISH (IN) .X .XX 0.030 .XX 0.010 .XXX 0.030 0.015 DIMENSIONS THAT AFFECT DENOTES CRITICAL S SAFE HANDLING OR OPERATION C DIMENSIONS AND GAUGE CHECK POINT APPROVALS DATE Insta7llation Instructions 6 Continua, SQ2 Wa5 ll Mount 4 3 2 REVISIONS REV. DESCRIPTION DATE CH Step 3 - Slide fixtures together, secure with cast joiners, and replace baffles. TO ROHS SPECIFICATION CL-ES-1025. Y A 3D MODEL. ANY OTHER FEATURE THAT IS NOT DIMENSIONED IN THE DRAWING CAN BE EXTRACTED FROM THE MODEL AND IS SUBJECT TO THE 2PL. TOLERANCE. ONS - CONFIDENTIAL AND PROPRIETARY IVING THIS DOCUMENT AND/OR TECHNICAL INFORMATION DRAWING AND INFORMATION CONTAINED THEREON, IS CONFIDENTIAL AND IS THE EXCLUSIVE PROPERTY OF COOPER LIGHTING SOLUTIONS, AND IS MERELY ON LOAN AND SUBJECT TO RECALL BY COOPER LIGHTING SOLUTIONS AT ON OF THIS DOCUMENT, THE RECIPIENT ACKNOWLEDGES AND AGREES THAT THIS DOCUMENT CANNOT BE USED IN ANY MANNER ADVERSE TO THE INTERESTS OF COOPER LIGHTING SOLUTIONS, AND THAT NO PORTION OF THIS OTHERWISE REPRODUCED WITHOUT THE PRIOR WRITTEN CONSENT OF COOPER LIGHTING SOLUTIONS. IN THE CASE OF CONFLICTING CONTRACTUAL PROVISIONS, THIS NOTICE SHALL GOVERN THE STATUS OF THIS DOCUMENT. 7 6 5 4 MATERIAL MASTER 3 ELECTRONIC CAD DRAWING. DO NOT REVISE MANUALLY. DIMENSIONS ARE IN INCHES DIMENSIONS THAT AFFECT S SAFE HANDLING OR OPERATION DIMENSIONS IN [ ] ARE IN MM TOLERANCE GENERAL SHEET METAL APPROVALS ENGLISH (IN) .X .XX .XXX METRIC (MM) .X .XX .XXX 0.030 0.010 0.005 0.75 0.25 0.12 .XX .XXX .XX .XXX 0.030 0.015 0.75 DRWN: 0.38 ANGLES ALL 1.0 CHKD: DENOTES CRITICAL C DIMENSIONS AND GAUGE CHECK POIN DATE SAP VERSION: THIRD ANGLE PROJECTION APPR: TITLE: MATERIAL: x.x x.x L MOD: 670246807 FINISH: 9/13/2023 SIZE: DW D DO NOT SCALE DRAWING SURFACE AREA:6158.885 IN2 2 SCALE: Installation Instructions - Corelite SQ2 Wall 9 IL52453823ML www.cooperlighting.com Warranties and Limitation of Liability Please refer to www.cooperlighting.com/global/warranty for our terms and conditions. Garanties et limitation de responsabilité Veuillez consulter le site www.cooperlighting.com/global/warranty pour obtenir les conditions générales. Garantías y Limitación de Responsabilidad Visite www.cooperlighting.com/global/warranty para conocer nuestros términos y condiciones. FCC Statement · This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference. (2) This device must accept any interference received, including interference that may cause undesired operation. Note: The grantee is not responsible for any changes or modifications not expressly approved by the party responsible for compliance. Such modifications could void the user's authority to operate the equipment. Note: The equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off an on, the user is encouraged to try to correct the interference by one or more of the following measures: · Reorient or relocate the receiving antenna. · Increase the separation between the equipment and receiver. · Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. · Consult the dealer or an experienced radio/TV technician for help. This device complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment must be installed and operated in accordance with provided instructions and the antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons. Cooper Lighting Solutions 18001 East Colfax Ave Aurora, CO 80011 P: 800-553-3879 www.cooperlighting.com © 2024 Cooper Lighting Solutions All Rights Reserved Printed in USA Imprimé aux États-Unis Impreso en los EE. UU. Publication No. IL52473324ML Cooper Lighting Solutions is a registered trademark. All trademarks are property of their respective owners. Cooper Lighting Solutions est une marque de commerce déposée. Toutes les autres marques de commerce sont la propriété de leur propriétaire respectif. Cooper Lighting Solutions es una marca comercial registrada. Todas las marcas comerciales son propiedad de sus respectivos propietarios. Product availability, specifications, and compliances are subject to change without notice La disponibilité du produit, les spécifications et les conformités peuvent être modifiées sans préavis La disponibilidad de productos, las especificaciones y los cumplimientos están sujetos a cambio sin previo aviso