User Guide for MITSUBISHI ELECTRIC models including: MXZ-3C24NAHZ3, 2 Ton Multi Zone Inverter Heat Pump System, MXZ-3C24NAHZ3 2 Ton Multi Zone Inverter Heat Pump System, Multi Zone Inverter Heat Pump System, Inverter Heat Pump System, Heat Pump System
Mitsubishi MXZ-3C24NAHZ3-U1 MSZ-FS06NA MSZ-FS18NA Wall Mounted 2-Zone H2i System - 24,000 BTU Outdoor - 6k 18k Indoor - 19.0 SEER
Mitsubishi MXZ-3C24NAHZ3-U1 MSZ-FS06NA MSZ-FS15NA Wall Mounted 2-Zone H2i System - 24,000 BTU Outdoor - 6k 15k Indoor - 19.0 SEER
MXZ-3C24NAHZ3 2-TON MULTI-ZONE INVERTER HEAT-PUMP SYSTEM Job Name: System Reference: Date: FEATURES · Variable speed INVETER-driven compressor · Built-in base pan heater · Quiet outdoor unit operation as low as 54 dB(A) · High pressure protection · Compressor thermal protection · Compressor overcurrent detection · Fan motor overheating/voltage protection · Hyper-heating performance offers 100% heating capacity at 5°F and 90% heating capacity at -13°F · ENERGY STAR® certified (non-ducted) ENERGY STAR products are third-party certified by an EPA-recognized Certification Body. Specifications are subject to change without notice. © 2022 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. SPECIFICATIONS: MXZ-3C24NAHZ3 test Cooling1 (Non-Ducted // Mix // Ducted) Heating at 47°F2 (Non-Ducted // Mix // Ducted) Heating at 17°F3 (Non-Ducted // Mix // Ducted) Heating at 5°F4 (Non-Ducted // Mix // Ducted) Efficiency (Non-Ducted // Mix // Ducted) Electrical Outdoor unit Maximum Capacity Rated Capacity Minimum Capacity Maximum Power Input Rated Power Input Power Factor (208V, 230V) Maximum Capacity Rated Capacity Minimum Capacity Maximum Power Input Rated Power Input Power Factor (208V, 230V) Maximum Capacity Rated Capacity Maximum Power Input Rated Power Input Maximum Capacity Maximum Power Input SEER EER1 HSPF (IV) COP at 47°F2 COP at 17°F at Maximum Capacity3 COP at 5°F at Maximum Capacity4 ENERGY STAR® Certified Electrical Power Requirements Guaranteed Voltage Range Voltage: Indoor - Outdoor, S1-S2 Voltage: Indoor - Outdoor, S2-S3 Short-circuit Current Rating (SCCR) Recommended Fuse/Breaker Size Recommended Wire Size Minimum Circuit Ampacity Maximum Overcurrent Protection Fan Motor Full Load Amperage Airflow Rate (Cooling / Heating) Refrigerant Control Defrost Method Heat Exchanger Type Sound Pressure Level, Cooling1 Sound Pressure Level, Heating2 Compressor Type Compressor Model Compressor Rated Load Amps Compressor Locked Rotor Amps Compressor Oil Type // Charge Base Pan Heater Unit Dimensions Package Dimensions Outdoor unit operating temperature range Refrigerant Unit Weight Package Weight Cooling Intake Air Temp (Maximum / Minimum*A) Cooling Thermal Lock-out / Re-start Temperatures Heating Intake Air Temp (Maximum / Minimum) Heating Thermal Lock-out / Re-start Temperatures Charge Chargeless Piping Length Additional Refrigerant Charge Per Additional Piping Length NOTES: AHRI Rated Conditions 1Cooling (Indoor // Outdoor) °F (Rated data is determined at a fixed compressor speed) 2Heating at 47°F (Indoor // Outdoor) °F 3Heating at 17°F (Indoor // Outdoor) °F BTU/H BTU/H BTU/H W W % BTU/H BTU/H BTU/H W W % BTU/H BTU/H W W BTU/H W Voltage, Phase, Frequency V AC V AC V DC kA A AWG A A A CFM dB(A) dB(A) A A oz. W: In. [mm] D: In. [mm] H: In. [mm] W: In. [mm] D: In. [mm] H: In. [mm] Lbs.[kg] Lbs.[kg] °FDB °FDB °FWB °FDB Lbs, oz Ft. [m] oz./Ft. [g/m] 80 DB, 67 WB // 95 DB, 75 WB 70 DB, 60 WB // 47 DB, 43 WB 70 DB, 60 WB // 17 DB, 15 WB 23,600 // 23,600 // 23,600 22,000 // 22,800 // 23,600 12,600 // 12,600 // 12,600 3,770 // 3,770 // 3,770 1,630 // 1,995 // 2,360 98.5, 98.5 // 98.5, 98.5 // 98.5, 98.5 30,600 // 30,600 // 30,600 25,000 // 24,800 // 24,600 11,400 // 11,400 // 11,400 4,540 // 4,540 // 4,540 1,725 // 1,809 // 1,871 97.3, 97.3 // 97.6, 97.4 // 97.4, 97.6 25,000 // 24,800 // 24,600 14,000 // 14,000 // 14,000 3,557 // 3,671 // 3,795 1,622 // 1,629 // 1,635 25,000 // 24,800 // 24,600 3,760 // 3,980 // 4,200 19.0 // 17.2 // 15.5 13.5 // 11.7 // 10.0 10.0 // 9.5 // 9.0 4.25 // 4.02 // 3.8 2.06 // 1.95 // 1.9 1.95 // 2.11 // 1.72 Yes // No // No 208/230, 1, 60 187-253 208/230 24 5 40 14 30.5 40 2.43 2,150 / 2,550 LEV Reverse Cycle Plate fin coil 54 58 DC INVERTER-driven Twin Rotary MNB33FBTMC-L 20 28.8 FV50S // 37.2 Built-in 37-13/32 [950] 13 [330] 41-17/64 [1,048] 41-3/8 [1,050] 17-3/8 [440] 46-3/4 [1,190] 189 [86] 212 [96] 115 / 14 10.4 / 14 65 / -13 -18 / -14 8.0, 13.0 98.0 [30.0] 0.216 [20] Conditions 4Heating at 5°F (Indoor // Outdoor) °F 70 DB, 60 WB // 5 DB, 4 WB *Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions. *A 5°F DB - 115°F DB when optional wind baffles are installed For actual capacity performance based on indoor unit type and number of indoor units connected, please refer to MXZ Operational Performance. Although the maximum connectable capacity is 130%, the outdoor unit cannot provide more than 100% of the rated capacity. Please utilize this over capacity capability for load shedding or applications where it is known that all connected units will NOT be operating at the same time. Specifications are subject to change without notice. © 2022 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. SPECIFICATIONS: MXZ-3C24NAHZ3 Indoor unit connection Piping Maximum Number of Connected IDU Minimum Number of Connected IDU Minimum connected capacity Maximum connected capacity Liquid Pipe Size O.D. (Flared) Gas Pipe Size O.D. (Flared) Total Piping Length Maximum Height Difference, ODU above IDU Maximum Height Difference, ODU below IDU Farthest Piping Length from ODU to IDU Maximum Number of Bends for IDU BTU/H BTU/H In.[mm] In.[mm] Ft. [m] Ft. [m] Ft. [m] Ft. [m] NOTES: AHRI Rated Conditions 1Cooling (Indoor // Outdoor) °F 80 DB, 67 WB // 95 DB, 75 WB (Rated data is determined at a fixed compressor speed) 2Heating at 47°F (Indoor // Outdoor) °F 70 DB, 60 WB // 47 DB, 43 WB 3Heating at 17°F (Indoor // Outdoor) °F 70 DB, 60 WB // 17 DB, 15 WB 3 2 12,000 27,000 A,B,C: 1/4 [A,B,C: 6.35] A: 1/2; B,C: 3/8 [A: 12.72; B,C: 9.52] 230 [70] 49 [15] 49 [15] 82 [25] 70 Conditions 4Heating at 5°F (Indoor // Outdoor) °F 70 DB, 60 WB // 5 DB, 4 WB *Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions. *A 5°F DB - 115°F DB when optional wind baffles are installed For actual capacity performance based on indoor unit type and number of indoor units connected, please refer to MXZ Operational Performance. Although the maximum connectable capacity is 130%, the outdoor unit cannot provide more than 100% of the rated capacity. Please utilize this over capacity capability for load shedding or applications where it is known that all connected units will NOT be operating at the same time. Specifications are subject to change without notice. © 2022 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Air Outlet Guide Ball Valve Drain Socket Hail Guards M-NET Converter Mounting Pad Port Adapter Stand OUTDOOR UNIT ACCESSORIES: MXZ-3C24NAHZ3 Air Outlet Guide (1 Piece) Refrigeration Ball Valve - 1/2" Refrigeration Ball Valve - 1/4" Refrigeration Ball Valve - 3/8" Refrigeration Ball Valve - 5/8" Drain Socket Hail Guard M-NET Converter Condensing Unit Mounting Pad: 16" x 36" x 3" Outdoor Unit 3-1/4 inch Mounting Base (Pair) - Plastic Adaptor: 1/2" x 3/8" Adaptor: 1/2" x 5/8" Adaptor: 3/8" x 1/2" Adaptor: 3/8" x 5/8" 18" Single Fan Stand 24" Single Fan Stand Condenser Wall Bracket Condenser Wall Bracket - Stainless Steel Finish Outdoor Unit Stand -- 12" High PAC-SH96SG-E BV12FFSI2 BV14FFSI2 BV38FFSI2 BV58FFSI2 PAC-SG60DS-E HG-A1 PAC-IF01MNT-E ULTRILITE1 DSD-400P MAC-A455JP-E MAC-A456JP-E MAC-A454JP-E PAC-SG76RJ-E QSMS1801M QSMS2401M QSWB2000M-1 QSWBSS QSMS1201M Specifications are subject to change without notice. © 2022 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. OUTDOOR UNIT DIMENSIONS: MXZ-3C24NAHZ3 Unit: inch (mm) FORM# MXZ-3C24NAHZ3 - 202206 Specifications are subject to change without notice. Lock nut Conduit plate Top Conduit connector Conduit plate Under 1340 Satellite Boulevard Suwanee, GA 30024 Toll Free: 800-433-4822 www.mehvac.com © 2022 Mitsubishi Electric Trane HVAC US LLC. All rights reserved.Adobe PDF Library 16.0.7 Adobe InDesign 17.3 (Macintosh)