Instructions for SUNSET models including: BF2200 Inline Bacterial Viral Filter, BF2200, Inline Bacterial Viral Filter, Bacterial Viral Filter, Viral Filter, Filter

BF2200 IFU REV 1-03-For-QT9

Mona Dean

Inline Bacterial Viral Filter for CPAP/BIPAP/Vent Units ...

2025. gada 24. apr. — Cautions. 1. Refer to the OEM's Instructions for Use for instructions on proper installation of filters. Filter specifications are stated below.

Cautions. 1. Refer to the OEM's Instructions for Use for instructions on proper installation of filters. Filter specifications are stated below.

Inline Bacterial Viral Filter Instruction Manual

BF2200 – Inline Bacterial Viral Filter for CPAP/BIPAP/Vent Units – Sunset Healthcare Solutions

PDF preview unavailable. Download the PDF instead.

BF2200-IFU-Rev-1-03
REF BF2200 Inline Bacterial Viral Filter for CPAP/BIPAP/Vent Units
Does not contain natural rubber latex
Intended for single patient use only
Please ensure safe disposal after use
Product Description and Indications The Sunset Inline Bacterial Viral Filter for CPAP/BIPAP/Vent Units is a single use replacement filter intended for use in mechanical ventilators, anesthesia machines, manual resuscitation devices, CPAP/BIPAP machines, and IPPB machines to reduce the passage of particulate that may carry airborne bacteria and/or viruses. When used with mechanical ventilators, IPPB machines and resuscitation devices, the replacement filter may be used in the hospital, home, or transport applications. The Sunset Inline Bacterial/Viral Filter is a replacement filter for use with Original Equipment Manufacturer's (OEM's) mechanical ventilators, anesthesia machines, manual resuscitation devices, CPAP/BIPAP machines, and IPPB machines.

Filter Specifications Bacterial Filtration Efficiency: (BFE) 99.99+% Viral Filtration Efficiency: (VFE) 99.9+% NaCl Particulate Filtration Efficiency: 96+% Flow Resistance: Approximately 8.8 mmH2O at 30 LPM Internal Volume: 66.3 mL without fittings / 78.3 mL with fittings Connections Patient End: 22 mm OD / 15 mm ID
Machine End: 22 mm ID
Cautions 1. Refer to the OEM's Instructions for Use for instructions on proper
installation of filters. Filter specifications are stated below. 2. Refer to OEM or your provider instructions for usage and replacement. 3. Placement of the filter between the tracheal or tracheostomy tube and
the patient breathing circuit will increase the dead space by 78ml. The Clinician compensates for the dead space during ventilatory set-up; refer to the OEM's instructions for use on the proper installation of the filters.
Warnings 1. Ensure all connections are secure. 2. For single patient use. Do not reuse.

Manufactured for Sunset Healthcare Solutions 141 W Jackson Blvd Ste 1950 Chicago IL 60604 MADE IN MEXICO
IFU-00065 REV 1.03 2024-07-02


Adobe PDF library 17.00