Intelbras DNB 10~30kVA 3-Phase 220V Online Tower UPS
Brand: Intelbras
Model Series: DNB 10kVA, DNB 20kVA, DNB 30kVA
Product Overview
The Intelbras DNB 10~30kVA 3-Phase 220V online tower UPS series is designed to provide high efficiency and reliability for critical applications. It is suitable for businesses, data centers, networks, telecommunications, broadcast, wholesale/retail infrastructure, industries, control and automation systems, healthcare, education, government, banks, and financial institutions.
High Reliability Features
- Protection Levels: 1. Mains failure/blackout; 2. Voltage distortions; 3. Voltage surges; 4. Under-voltage and Over-voltage; 5. Electromagnetic noise; 6. Frequency variations; 7. Generator switching transients; 8. Power factor correction.
- Wide Input Voltage Range: Features an input voltage range of 138Vac~485Vac and an input frequency of 40-70Hz. This high adaptability allows operation without switching to battery mode, extending battery life and reducing Total Cost of Ownership (TCO).
- High Overload Capacity: In double conversion mode, it supports 105% load for extended operation, 130% load for 10 minutes, and 155% load for 1 minute.
- High Power Factor: Achieves a power factor of VA = Watt (1.0).
- Corrosion-Resistant Coating: PCBs are coated to provide enhanced protection against environmental influences like dust, salt mist, and corrosion.
- Intelligent Fan Control: Automatic fan speed adjustment optimizes energy consumption and reduces noise.
- Advanced Short-Circuit Protection: Configurable protection time from 10 to 200 ms ensures continuous operation for connected circuits.
- Cold Start Function: Allows the UPS to start directly from batteries without a mains connection.
- Dual DSP: High-precision and high-speed Dual DSP independently controls the rectifier and inverter, ensuring reliability and high performance.
Flexible Design
- Maintenance Bypass Switch: Enables scheduled maintenance without disconnecting loads, ensuring operational continuity and protection.
- Impact Load Function: The UPS can support transformer loads at its output.
- Battery Compatibility: Compatible with VRLA or vented lead-acid batteries.
- Active Parallelism: Supports active parallelism of up to 4 units for power expansion and N+X redundancy (parallel plates and cables included).
- Shared Batteries: Allows sharing a battery bank among up to 2 parallel UPS units, saving space and reducing TCO.
Frequency Conversion
The frequency conversion function allows input voltage at 60Hz to be output at 50Hz, or vice versa, enabling the operation of sensitive imported equipment.
Green Power
- IGBT and Three-Level Inverter: Utilizes IGBT and three-level inverter technology, offering THDi <3% at full load, an input power factor >0.99, AC/AC efficiency up to 96%, and ECO mode efficiency up to 99%.
- Self-Load Test: The self-load test function simplifies commissioning, saving time and costs by eliminating the need for expensive temporary loads or complex cabling preparations.
Intelligent Management
- Pre-Alarm Function: Allows programming alerts for maintenance needs of key components (capacitors, fans) and accessories (batteries, dust filters).
- Smart De-Dust Function: Automatic fan cleaning removes excessive dust. Programmable with adjustable intervals, reducing preventive maintenance time.
- Multiple Interfaces: Includes RS485, EPO, parallelism, 2 intelligent slots for SNMP cards, dry contact, and BMS.
User-Friendly Interface
- 4.3" Touch Screen Display: Features a color 4.3" touch screen with LED indicators.
- Intuitive Graphical Interface: Displays a single-line diagram showing system status, including voltage, current, UPS temperature, operating status, load capacity, and battery capacity.
- Extensive Data Storage: Capable of storing up to 1000 events.
- Start/Stop Button: Equipped with protection against accidental activation to prevent unintentional shutdown of critical loads.
System Diagram
The system diagram illustrates the power flow: Mains power connects to a Rectifier and a Static Switch. The Rectifier charges the Batteries and supplies the Inverter. The Inverter then powers the load. The Static Switch can bypass the inverter, directly connecting mains to the load, or switch to the inverter's output.
Components: Rede (Mains), Retificador (Rectifier), Chave Estática (Static Switch), Baterias (Batteries), Inversor (Inverter).
Technical Specifications
Specification | 10kVA-3PH-220V-TT-TW | 20kVA-3PH-220V-TT-TW | 30kVA-3PH-220V-TW |
---|---|---|---|
Model | 10kVA-3PH-220V-TT-TW | 20kVA-3PH-220V-TT-TW | 30kVA-3PH-220V-TW |
Topology | Online Double Conversion | ||
Waveform | Pure Sine Wave | ||
UPS Classification | According to IEC 62040-3: VSI SS 111 | ||
Input | |||
Nominal Voltage | 220V(F-F)/127V(F-N) | ||
Voltage Range | 154-265V(F-F) @ 75%-100% Load; 120-265V(F-F) @ 0%-75% Load | ||
Phases | 3:3 (3-phase input - 3-phase output) | ||
Nominal Frequency | 50 / 60 Hz (Automatic Detection) | ||
Frequency Range | 40 - 70 Hz | ||
Power Factor | ≥0.99 | ≥0.99 | ≥0.99 |
Empty Consumption | 100 W | 200 W | 300 W |
THDi | <3% (linear load) | ||
Generator Input | Compatible | ||
Input Breaker | Yes | ||
Output | |||
Power | 10 kVA / 10 kW | 20 kVA / 20 kW | 20 kVA / 20 kW |
Power Factor | 1.0 | 1.0 | 1.0 |
Voltage | 190/200/208/220 V (L-L) | ||
Frequency (Hz) | 50/60Hz ± 0.1Hz (Battery Mode) | ||
Phases | 3:3 | ||
Freq. Range (Double Conversion Mode) | Input: 50/60 HZ ± 5Hz - Output: Synchronized with mains; Input: 40-70Hz. Output: 50/60Hz ± 0.1Hz without synchronization. | ||
Crest Factor | 3:1 | ||
Voltage Regulation (Double Conversion Mode) | Static: ± 1% | Static: ± 1% | Static: ± 1% |
Dynamic: ± 3% | Dynamic: ± 3% | Dynamic: ± 3% | |
Waveform | Sine Wave | ||
THDv | THD <1% (linear load) THD <3% (non-linear load) | ||
Efficiency AC/AC (max.) | 94% | 94% | 94% |
ECO Mode | 98% | 98% | 98% |
Transfer Time | 0 ms | ||
Overload Protection | 105%~110% load: 60 min; 110%~130% load: 10 min; 130%~150% load: 1 min; >150% load: transfers to bypass immediately. | ||
Bypass | |||
Output Breaker | Automatic and manual | ||
Bypass | Yes | ||
Overload | Load: 0-130%: Unlimited operation; Load: 130% - 155%: 1 minute; Load: >155%: 200ms | ||
Voltage Range | ±10%/±15%/±15% | ||
Frequency Range | ±5%/±10% | ||
Connection | Bypass connection independent of rectifier input | ||
Battery | |||
Voltage | ±120 (±96~±120 configurable) | ||
Battery Type | VRLA 12 V / 9 Ah | ||
Internal Battery Quantity² | 2×10 (20 total) | 2×2×10 (40 total) | 2×3×10 (60 total) |
Recharge Current | 2A (1-10A config.) | 2A (1-20A config.) | 2A (1-20A config.) |
External Battery Terminal | Terminal block | Terminal block | Terminal block |
Battery Cabinet Compatible | 4820223 - GB 8009-TW-126A | ||
DoD Voltage | 10.5 V / Battery | ||
Float Voltage | 13.5 V / Battery | ||
External Battery Breaker | Yes | ||
Resources | |||
Protections | Low battery, overload, short circuit, overheating, and other related faults | ||
End of autonomy in battery mode | Emits audiovisual alert and shuts down the UPS | ||
Self-diagnosis | Yes | ||
Audiovisual Alarms | Short circuit, low battery, overload, overheating, system failures |
Autonomy Table (Hours:Minutes)
Note: Values are approximate and depend on battery module configuration (+40*9AH).
Model | Battery Module | Runtime (Hours:Minutes) | |||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
1.0KW | 2.0KW | 3.0KW | 4.0KW | 5.0KW | 6.0KW | 7.0KW | 8.0KW | 9.0KW | 10.0KW | ||
10kVA | 0 | 53min | 22min | 12min | 8min | 6min | 5min | 4min | 3min | 2min | 2min |
1 | 8h9min | 3h20min | 1h57min | 1h19min | 59min | 46min | 37min | 31min | 26min | 23min | |
2 | 18h15min | 7h28min | 4h22min | 2h58min | 2h12min | 1h43min | 1h24min | 1h10min | 59min | 51min | |
3 | 30h12min | 12h23min | 7h14min | 4h56min | 3h39min | 2h51min | 2h19min | 1h56min | 1h39min | 1h25min | |
4 | 43h37min | 17h53min | 10h28min | 7h7min | 5h16min | 4h7min | 3h21min | 2h48min | 2h23min | 2h4min | |
5 | 58h16min | 23h53min | 13h58min | 9h31min | 7h3min | 5h31min | 4h28min | 3h44min | 3h11min | 2h45min | |
20kVA | 0 | 53min | 22min | 12min | 8min | 6min | 5min | 4min | 3min | 2min | 2min |
1 | 4h3min | 1h39min | 58min | 39min | 29min | 23min | 18min | 15min | 13min | 11min | |
2 | 8h9min | 3h20min | 1h57min | 1h19min | 59min | 46min | 37min | 31min | 26min | 23min | |
3 | 12h56min | 5h18min | 3h6min | 2h6min | 1h33min | 1h13min | 59min | 49min | 42min | 36min | |
4 | 18h15min | 7h28min | 4h22min | 2h58min | 2h12min | 1h43min | 1h24min | 1h10min | 59min | 51min | |
5 | 24h1min | 9h51min | 5h45min | 3h55min | 2h54min | 2h16min | 1h50min | 1h32min | 1h18min | 1h8min | |
30kVA | 0 | 53min | 22min | 12min | 8min | 6min | 5min | 4min | 3min | 2min | 2min |
1 | 2h52min | 1h10min | 41min | 28min | 20min | 16min | 13min | 11min | 9min | 8min | |
2 | 5h20min | 2h11min | 1h16min | 52min | 38min | 30min | 24min | 20min | 17min | 15min | |
3 | 8h09min | 3h20min | 1h57min | 1h19min | 59min | 46min | 37min | 31min | 26min | 23min | |
4 | 11h16min | 4h37min | 2h42min | 1h50min | 1h21min | 1h4min | 52min | 43min | 37min | 32min | |
5 | 14h39min | 6h0min | 3h30min | 2h23min | 1h46min | 1h23min | 1h7min | 56min | 48min | 41min |
Accessory Compatibility
UPS | Battery Cabinet | Remote Management Card | Dry Contact Card |
---|---|---|---|
4820165 - DNB 10KVA-3PH-220V-TT-TW | 4820223 - GB 8009-TW-126A | 4820137 - PGR 502S | 4820138 - PCS 485Y3 |
4820163 - DNB 20KVA-3PH-220V-TT-TW | |||
4820186 - DNB 30KVA-3PH-220V-TT-TW |