Installation Guide for 3onedata models including: GW1118-8DI Modbus Gateway, GW1118-8DI, Modbus Gateway, Gateway
GW1118-8DI(3IN1)-RJ-P(12-48VDC)
GW1118-8DI(3IN1)-RJ-P(12-48VDC) Modbus Gateway Quick Installation Guide Panel Design Top view Front View 3onedata Co., Ltd. Address: 3/B, Zone 1, Baiwangxin High Technology Industrial Park, Xili, Nanshan District, Shenzhen Rear View Website: www.3onedata.com Tel: +86 0755-26702688 Fax: +86 0755-26703485 Package Checklist Please check whether the package and accessories are intact Left view while using the device for the first time. 1. Modbus gateway 2. Lugs 3. Power adapter 4. Straight-through cable 5 Foot pad 6. Warranty card 7. Certification Right view If any of these items are damaged or lost, please contact our company or dealers, we will solve it ASAP. Product Overview The product is MODBUS gateway devices. Model is: Bottom view GW1118-8DI(3IN1)-RJ-P(12-48VDC) (8 RS-485/422/232 serial ports with isolation + 2 100M copper ports + 1 12~48VDC power supply). 1. Power indicator 2. Running indicator 3. Copper port connection indicator 4. Serial port transmission data indicators 5. Serial port receiving data indicators 6. Grounding screw 7. Terminal blocks for power input 8. Reset button 9. Console port 10. 100M copper port 11. RS-485/422/232 serial port 12. Foot pad 13. Wall-mounting location hole Mounting Dimension Unit: mm Notice Before Mounting: Don't place or install the device in area near water or moist, keep the relative humidity of the device surrounding between 5%~95% without condensation. Before power on, first confirm the supported power supply specification to avoid over-voltage damaging the device. The device surface temperature is high after running; please don't directly contact to avoid scalding. Wall-mounted Device Mounting Step 1 Adopt M3 screw to install the left/right mounting board on the device backboard. Step 2 On the wall of device mounting, place the device on the wall for reference or refer to the mounting Step 3 Step 4 dimension to mark two screw positions. Nail M4 screws on the wall and keep 2mm interspace reserved. Hang the device on two screws and slide downward, then tighten the screw to enhance stability, mounting ends. Wall-mounted Device Disassembling Step 1 Device power off. Step 2 Unscrew the screw on the wall about 2mm. Step 3 Lift the device upward slightly; take out the device, disassembling ends. Notice before power on: Power ON operation: First insert the power supply terminal block into the device power supply interface, and then plug the power supply plug contact and power on. Power OFF operation: first unpin the power plug, then remove the power line, please note the operation order above. Power Supply Connection This device supports 1 DC power input, and provides 3-Pin 5.08mm pitch terminal blocks, in which V+ and V- are DC input, FG is the power grounding input; The power supply supports non-polarity, power supply range: 12 48VDC. Reset Button Setting This device provides 1 reset button, press the button for 4-5S then release it to restore factory defaults. Serial Port Connection This device provides 8 3IN1 serial ports, which support RS232, RS485 and RS422 at the same time. The interface type is RJ45 and its pin definitions are as follows: PIN 1 2 3 4 5 6 7 8 RS-232 DSR RTS GND TXD RXD DCD CTS DTR RS-485 -- -- GND -- D+ D- -- -- RS-422 -- T+ GND T- R+ R- -- -- Checking LED Indicator The device provides LED indicators to monitor the device working status with a comprehensive simplified troubleshooting; the detailed status of each LED is described in the table as below: LED PWR Indicate ON OFF Blinking Description PWR is connected and running normally PWR is disconnected and running abnormally The system is running normally RUN OFF ON ON LINK (1-2) Blinking OFF The system is not running or running abnormally System is running abnormally Copper port has established an active network connection. Copper port is in a network activity state. Copper port has not established an active network connection Serial port is not transmitting OFF TX (1-8) data or transmitting data abnormally RX (1-8) Blinking OFF Serial port is transmitting data. Serial port is not receiving data or receiving data abnormally Blinking Serial port is receiving data Logging in to WEB Interface This device supports WEB management and configuration. Computer can access the device via Ethernet interface. The way of logging in to device's configuration interface via IE browser is shown as below: Step 1 Configure the IP addresses of computer and the device to the same network segment (The network segment of Network Port 1 is 1, and the network segment of network port 2 is 8), and the network between them can be mutually accessed. Step 2 Enter device's IP address in the address bar of the computer browser. Network Port 1: Network Port 2: "admin". If the user name or password is lost, user can restore it to factory settings via restore button or management software; all modified configurations will be cleared after restoring to factory settings, so please backup configuration file in advance. Please refer to user manual for specific configuration method of logging in to WEB interface and other configurations about network management function. Specification Panel 100M Copper Port 10/100Base-T(X) self-adapting RJ45 port Serial Port 3IN1 RJ45 interface with isolation Indicator Power indicator, Running indicator, Copper port connection indicator, Serial port transmission and receiving data indicator Step 3 Enter device's username and password in the login window as shown below. Power Supply Input power supply Access terminal block 12~48VDC 3 pins 5.08mm pitch terminal blocks Step 4 Click "OK" button to login to the WEB interface of the device. Power Consumption No-load Full-load Working Environment Working temperature Storage temperature Working humidity Protection grade 3.4W@12VDC 4.1W@12VDC -40~75 -40~85 5% 95%(no condensation) IP40(metal shell) Note: The default IP address of the device network port 1 is "192.168.1.254", port 2 is "192.168.8.254". The default user name and password of the device areCanva Canva