Argus Instruction Manual

Solid Door Reach-in Refrigerators & Freezers

Refrigerators: ARF-1D, ARF-2D, ARF-3D-SS

Freezers: AFZ-1D, AFZ-2D, AFZ-3D-SS

Important Information

This manual contains important information regarding your unit. Please read this manual thoroughly prior to equipment set-up, operation and maintenance. Failure to comply with regular maintenance guidelines outlined in this manual may void the warranty.

WARNINGS

INSTALLATION

Please fill out the registration card and send it back to the manufacturer.

Cabinet Location Guidelines

ELECTRICAL

TEMPERATURE CONTROLS

Factory set temperature is an average of 38°F. Adjust controls on the front of the unit for different temperatures.

Freezer Control

Digital display with buttons for Program (Prg), Mute, Aux, Set, and Up/Down arrows (▼/▲).

Refrigerator Control

Digital display with buttons for Mute, Set, and Up/Down arrows (▼/▲).

Operations - Regulating the Temperature

Refrigerators cycle between 33°F and 40°F. Freezers cycle between -7°F and 0°F.

To change the temperature:

If the unit consistently runs 5°F higher than the set temperature, service may be needed. Other control functions should be performed by a service technician.

LOADING PRODUCT

DEFROST SYSTEMS

Servicing should be performed by an authorized service technician.

REGULAR MAINTENANCE

Cleaning Condenser

Cleaning the Fans and Motor

Cleaning the Interior of Unit

TROUBLESHOOTING

Before requesting service, check the following chart. Service calls due to lack of maintenance or misuse are not covered by warranty.

SYMPTOM POSSIBLE CAUSE CORRECTIVE ACTION
Compressor not running Blown fuse or circuit breaker tripped Replace or reset circuit breaker
Unplugged power cord Plug in power cord
Thermostat set too high Set thermostat to lower temperature
Cabinet in defrost cycle Wait for defrost cycle to finish
Condenser runs for long Periods of time Excessive amount of warm Products placed in cabinet Allow adequate time for Product to cool down
Prolonged door opening or door left open Ensure doors are closed. Avoid leaving the door open for long periods of time
Door gasket(s) not creating a proper seal Ensure gasket is installed correctly and that it is clean. Replace gasket if necessary.
Dirty condenser coil Clean the condenser coil
Evaporator coil iced over Unplug unit and allow coil to defrost. Ensure that the thermostat is not set to cold. Ensure that the door gasket is creating a proper seal.
Cabinet is noisy Loose parts Locate and tighten loose parts
Tubing Vibration Ensure tubing is free from contact with other tubing or components.

WARRANTY

TWO YEAR WARRANTY

Argus warrants to the original purchaser that the cabinet and all parts are free from defects in material or workmanship under normal use and service for two (2) years from the date of original purchase.

Defective parts will be repaired or replaced. Options include:

ADDITIONAL THREE YEAR COMPRESSOR PART WARRANTY

In addition to the two-year warranty, the compressor is warranted for three (3) additional years from the date of original purchase, not to exceed five (5) years and three (3) months after shipment from the manufacturer. This warranty covers only the hermetically and semi-hermetically sealed parts of the compressor.

134A (404A) AND R290 COMPRESSOR WARRANTY

To maintain this warranty, follow these procedures:

WHAT IS NOT COVERED BY THIS WARRANTY

WARRANTY REGISTRATION CARD

National Service America • 230 Park Ave, 3rd Floor WEST • New York, NY • 10169

MAIL CARD IMMEDIATELY AFTER PURCHASE FOR WARRANTY TO BE IN EFFECT.

Business Information:

Owner Information:

The above warranties are in effect from this purchase date.

Models: ARF-1D, ARF-2D, ARF-3D-SS, AFZ-1D, AFZ-2D, AFZ-3D-SS, ARF-1D Solid Door Reach-In Refrigerator, Solid Door Reach-In Refrigerator, Reach-In Refrigerator, Refrigerator, ARF Series, AFZ Series

File Info : application/pdf, 6 Pages, 859.59KB

PDF preview unavailable. Download the PDF instead.

argus reach-in-manual

References

Adobe PDF Library 15.0 Adobe InDesign 14.0 (Windows)

Related Documents

Preview Argus Solid Door Reach-In Refrigerators ARF-1D, ARF-2D - Specifications
Detailed specifications and features for Argus Solid Door Reach-In Refrigerators, models ARF-1D and ARF-2D. Includes construction, temperature, warranty, and dimensions.
Preview Argus Reach-In Refrigerators and Freezers: Product Specifications and Features
Explore the features, specifications, and model details for Argus Reach-In Refrigerators and Freezers, including durable stainless steel construction, efficient refrigeration systems, and digital temperature control.
Preview Argus Commercial Gas Range User Manual (HFSO-36/60)
User manual for Argus Commercial Gas Ranges, models HFSO-36 and HFSO-60. Provides detailed information on safety, installation, operation, controls, gas conversion, cleaning, maintenance, troubleshooting, parts lists, and warranty.
Preview ARGUS Commercial Gas Range User Manual - HFSO-36/60
Comprehensive user manual for ARGUS Commercial Gas Ranges, models HFSO-36 and HFSO-60. Provides detailed information on installation, operation, gas conversion, cleaning, maintenance, troubleshooting, and warranty.
Preview ARGUS E4 Elite Mid-Tower PC Case Quick Installation Guide
This guide provides instructions for installing the ARGUS E4 Elite mid-tower PC case, detailing specifications, component mounting, cooling compatibility, and front panel I/O connections.
Preview Argus U046 User Manual and Technical Specifications
User manual and technical specifications for the Argus U046, detailing its features, operation, and maintenance. Includes multilingual support.