Ruud Endeavor® Line Achiever Plus® Series iM Heat Pumps

Model Series: RP15AY

Product Overview

The Ruud Endeavor® Line Achiever Plus® Series iM Heat Pumps (RP15AY) offer high-efficiency cooling and heating performance. These units feature two-stage operation for precise temperature control and enhanced comfort.

Key Specifications:

  • Cooling Efficiencies: Up to 16 SEER2 / 11.7 EER2
  • Heating Efficiencies: Up to 8.1 HSPF2
  • Nominal Sizes: 1.5 to 5 Tons [5.3 to 17.6 kW]
  • Cooling & Heating Capacities: 17.1 kBTU to 57 kBTU [5.0 to 16.7 kW]
  • Refrigerant Type: R-454B

Note: Proper sizing and installation are critical for optimal performance. Consult with a qualified contractor.

This product meets ENERGY STAR® requirements when matched with appropriate coil components. For details, visit energystar.gov.

Features and Benefits

  • Two-Stage Scroll Compressor: Provides two speeds (high and low) for cooling and heating, ensuring more precise temperature control, lower humidity, and greater efficiency compared to single-stage compressors.
  • 7mm Condenser Copper Coil: Requires less refrigerant, resulting in a smaller and lighter footprint while enhancing reliability.
  • Inverted Reversing Valve: Facilitates faster heat transfer with gravity assist shifting and reduced joint stress for increased reliability.
  • PlusOne® Expanded Valve Space: Offers 3 in. – 4 in. – 5 in. service valve space, providing a minimum working area of 27 square inches for easier access during maintenance.
  • PlusOne® Triple Service Access: Features a 15-inch wide access panel with two fasteners and removable corner and individual louver panels, making repairs faster and easier.
  • PlusOne® Refrigerant Detection System™: An integrated, patented system with an A2L sensor and mitigation board for easier commissioning, simplified wiring, and system protection that pauses operation if excess refrigerant is detected.
  • Designing for Sustainability with Low GWP: Utilizes R-454B refrigerant, which has a significantly lower Global Warming Potential (GWP) than previous refrigerants, aligning with environmental protection goals and delivering energy-efficient comfort.

Model Number Identification

The model number provides key information about the heat pump's specifications. The structure is generally:

R P 15 A Y [Capacity] J 2 N A

  • R: Brand (Ruud)
  • P: Product Category (Heat Pump)
  • 15: SEER2 Rating (15.2 SEER2)
  • A: Region (All Regions)
  • Y: Refrigerant Type (R-454B)
  • [Capacity]: Nominal capacity in thousands of BTU/h (e.g., 18 for 18,000 BTU/h, 60 for 60,000 BTU/h)
  • J: Voltage (208/230/1/60)
  • 2: Stage (2-Stage)
  • N: Control Type (Non-Communicating)
  • A: Series Designator

Available Models:

Model NumberDescription
RP15AY18AJ2NAEndeavor® Line Achiever Plus® Series 1.5 ton 15.2 SEER2 2-Stage Heat iM Pump-208/230/1/60
RP15AY24AJ2NAEndeavor® Line Achiever Plus® Series 2 ton 15.2 SEER2 2-Stage Heat iM Pump-208/230/1/60
RP15AY30AJ2NAEndeavor® Line Achiever Plus® Series 2.5 ton 15.2 SEER2 2-Stage Heat iM Pump-208/230/1/60
RP15AY36AJ2NAEndeavor® Line Achiever Plus® Series 3 ton 15.2 SEER2 2-Stage Heat iM Pump-208/230/1/60
RP15AY42AJ2NAEndeavor® Line Achiever Plus® Series 3.5 ton 15.2 SEER2 2-Stage Heat iM Pump-208/230/1/60
RP15AY48AJ2NAEndeavor® Line Achiever Plus® Series 4 ton 15.2 SEER2 2-Stage Heat iM Pump-208/230/1/60
RP15AY60AJ2NAEndeavor® Line Achiever Plus® Series 5 ton 15.2 SEER2 2-Stage Heat iM Pump-208/230/1/60

Standard Equipment:

  • R-454B Refrigerant
  • Scroll Compressor
  • Field Installed Filter Drier
  • Front Seating Service Valves
  • Internal Pressure Relief Valve
  • Internal Thermal Overload
  • Long Line capability
  • Low Ambient capability with Kit
  • 3-4-5 Expanded Valve Space
  • Composite Basepan
  • 2 Screw Control Box Access
  • 15" Access to Internal Components
  • Quick release louver panel design
  • No fasteners to remove along bottom
  • Optimized Venturi Airflow
  • Powder coated paint
  • Rust resistant screws
  • QR code [QR code symbol]
  • External gauge ports
  • Service trays

General Data and Electrical Specifications

Model No.Nominal TonnageLiquid Line O.D. (in.)Suction Line O.D. (in.)Refrigerant (R-454B) furnished (oz.)Compressor TypeOutdoor Coil Net Face Area (Outer Coil)Outdoor Coil Net Face Area (Inner Coil)Tube diameter (in.)Number of rowsFins per inchOutdoor Fan Diameter (in.)Number of bladesMotor hpCFMRPMWattsShipping weight (lbs.)Operating weight (lbs.)
RP15AY18A1.53/83/4832-stage Scroll10.910.50.2762222021/625821075145157150
RP15AY24A2.03/83/48310.910.50.2762222021/625821075145157150
RP15AY30A2.53/83/48519.5--0.2761222431/54077850222209202
RP15AY36A3.03/87/88821.5--0.2761222431/54206850246221214
RP15AY42A3.53/87/813021.5--0.2761222431/54206850246247240
RP15AY48A4.03/87/813021.5--0.2761222431/54206850246247240
RP15AY60A5.03/87/823423.422.70.2762222631/54396850284282275

Electrical Data:

RP15AY18ARP15AY24ARP15AY30ARP15AY36ARP15AY42ARP15AY48ARP15AY60A
Line Voltage Data (Volts-Phase-Hz)208/230-1-60
Maximum overcurrent protection (amps)20253030404550
Minimum circuit ampacity13162020242733
Compressor
Rated load amps10121515182025
Locked rotor amps52658290106141147
Condenser Fan Motor
Full load amps0.80.81.21.21.21.21.2
Locked rotor amps1.51.52.62.62.62.62.6

Notes: Refrigerant charge is sufficient for 15 ft. of refrigerant lines. For longer line set requirements, consult installation instructions. HACR type circuit breaker or fuse is recommended. Refer to National Electrical Code for wire, fuse, and disconnect size requirements.

Accessories

MODEL NO.RP15AY18ARP15AY24ARP15AY30ARP15AY36ARP15AY42ARP15AY48ARP15AY60A
Compressor crankcase heater*44-17402-4444-17402-4444-17402-4444-17402-4444-17402-4444-17402-45Factory Standard
Low ambient controlRXAD-A08RXAD-A08RXAD-A08RXAD-A08RXAD-A08RXAD-A08RXAD-A08
Compressor sound cover68-23427-2668-23427-2668-23427-2668-23427-2668-23427-2668-23427-2568-23427-25
Compressor hard start kitSK-A1SK-A1SK-A1SK-A1SK-A1SK-A1SK-A1
Low pressure controlFactory StandardFactory StandardFactory StandardFactory StandardFactory StandardFactory StandardFactory Standard
High pressure controlFactory StandardFactory StandardFactory StandardFactory StandardFactory StandardFactory StandardFactory Standard
Liquid Line Solenoid Valve (24 VAC, 50/60 Hz)200RD2T3TVLC200RD2T3TVLC200RD2T3TVLC200RD2T3TVLC200RD2T3TVLC200RD3T3TVLC200RD3T3TVLC
Solenoid Coil (24 VAC)61-AMG24V61-AMG24V61-AMG24V61-AMG24V61-AMG24V61-AMG24V61-AMG24V
Liquid Line Solenoid Valve (120/240 VAC, 50/60 Hz)200RD2T3TVLC200RD2T3TVLC200RD2T3TVLC200RD2T3TVLC200RD2T3TVLC200RD3T3TVLC200RD3T3TVLC
Solenoid Coil (120/240 VAC)61-AMG120/240V61-AMG120/240V61-AMG120/240V61-AMG120/240V61-AMG120/240V61-AMG120/240V61-AMG120/240V

*Bi-flow kits are required when installing a liquid line solenoid on a heat pump.

Weighted Sound Power Level (dBA)

UNIT SIZE - VOLTAGE, SERIESSTANDARD RATING (dBA)TYPICAL OCTAVE BAND SPECTRUM (dBA WITHOUT TONE ADJUSTMENT)
125 Hz250 Hz500 Hz1000 Hz2000 Hz4000 Hz8000 Hz
RP15AY18A7358.058.862.062.359.256.650.5
RP15AY24A7356.659.662.262.158.855.450.8
RP15AY30A7355.158.365.663.558.554.948.5
RP15AY36A7451.256.463.163.860.857.456.5
RP15AY42A7456.657.464.964.062.057.450.4
RP15AY48A7457.357.064.164.061.158.056.5
RP15AY60A7443.955.263.465.861.757.952.9

Note: Tested in accordance with AHRI Standard 270-08.

Unit Dimensions

MODEL NO.OPERATINGSHIPPING
H (Height)L (Length)W (Width)H (Height)L (Length)W (Width)
INCHES | mmINCHES | mmINCHES | mmINCHES | mmINCHES | mmINCHES | mm
RP15AY18A25.00 | 63529.75 | 75629.75 | 75627.90 | 70933.25 | 84533.25 | 845
RP15AY24A25.00 | 63529.75 | 75629.75 | 75627.90 | 70933.25 | 84533.25 | 845
RP15AY30A35.00 | 88933.75 | 85733.75 | 85738.35 | 97437.64 | 95637.64 | 956
RP15AY36A39.00 | 99135.75 | 90835.75 | 90840.50 | 102938.38 | 97538.38 | 975
RP15AY42A39.00 | 99135.75 | 90835.75 | 90840.50 | 102938.38 | 97538.38 | 975
RP15AY48A39.00 | 99135.75 | 90835.75 | 90840.50 | 102938.38 | 97538.38 | 975
RP15AY60A39.00 | 99135.75 | 90835.75 | 90840.50 | 102938.38 | 97538.38 | 975

Clearances

Proper clearances are essential for optimal performance and serviceability. The following minimum clearances are recommended:

  • Service Access: 24 inches (609.6 mm)
  • Side Clearance: 6 inches (152.4 mm)
  • Top Clearance: 12 inches (304.8 mm)
  • Front Clearance: 24 inches (609.6 mm) recommended, 6 inches (152.4 mm) minimum.
  • Overall Unit Clearance: Allow 60 inches (1524 mm) of clearance around the unit.

Important: When installing multiple units in an alcove, roof well, or partially enclosed area, ensure adequate ventilation to prevent re-circulation of discharge air.

Refrigerant Line Size Information

This section provides detailed guidelines for selecting appropriate refrigerant line sizes based on unit capacity, equivalent length, and maximum vertical separation. These tables are crucial for ensuring optimal system performance and efficiency. They cover various combinations of liquid and suction line sizes for different unit tonnages and equivalent lengths up to 250 feet (76 meters).

Note: Light grey shaded areas in the original tables indicate conditions considered "long line" and may require specific accessories. Consult the Long Line Set Guide for details. Avoid using suction line traps in the suction riser as they can increase pressure drop.

Performance Data @ AHRI Standard Conditions - Cooling

OUTDOOR UNITAIR HANDLERTOTAL CAPACITY BTU/H [kW]NET SENSIBLE BTU/H [kW]NET LATENT BTU/H [kW]SEER2EER2INDOOR CFM [L/S]47 DEGREE HEATING CAPACITY BTU/H [KW]47 DEGREE COP17 DEGREE HEATING CAPACITY BTU/H [KW]17 DEGREE COPREGION HSPF2
RP15AY18AJ2NRH2TY2417STANN17,100 [5.0]13,100 [3.8]4,000 [1.2]15.211.7625 [295.0]17,100 [5.0]3.6010,000 [2.9]2.407.8
RP15AY24AJ2NRH2TY2417STANN22,800 [6.7]17,500 [5.1]5,300 [1.6]15.211.7775 [365.8]22,600 [6.6]3.6014,000 [4.3]2.507.8
RP15AY30AJ2NRH2TY3617STANN28,600 [8.4]21,900 [6.4]6,700 [2.0]15.211.7950 [448.4]28,600 [8.4]3.4018,000 [5.3]2.407.8
RP15AY36AJ2NRH2TY3617STANN34,200 [10.0]26,200 [7.7]8,000 [2.3]15.211.71,050 [495.5]33,200 [9.7]3.1022,200 [6.9]2.507.8
RP15AY42AJ2NRH2TY4821STANN40,000 [11.7]30,700 [9.0]9,300 [2.7]15.211.71,300 [613.5]40,000 [11.7]3.6025,000 [7.3]2.507.8
RP15AY48AJ2NRH2TY4821STANN45,500 [13.3]34,900 [10.2]10,600 [3.1]15.211.71,450 [684.3]44,000 [13.0]3.6029,600 [8.6]2.507.8
RP15AY60AJ2NRH2TY6024STANN57,000 [16.7]43,700 [12.8]13,300 [3.9]15.211.71,800 [849.5]55,000 [16.1]3.6032,000 [10.0]2.507.8

Note: This data includes DTC (Designated Test Combination) ratings for reference. Official ratings and system match-ups are available from the AHRI website (ahridirectory.org).

General Terms of Limited Warranty

Ruud provides a limited warranty, offering replacement for any part of this product that fails in normal use and service within the applicable period.

  • Conditional Parts Warranty: Ten (10) Years (Registration Required).

For complete details on Limited and Conditional Warranties, including applicable terms and conditions, contact your local contractor or the Manufacturer.

Models: RP15AY18AJ2NA, RP15AY24AJ2NA, RP15AY30AJ2NA, RP15AY36AJ2NA, RP15AY42AJ2NA, RP15AY48AJ2NA, RP15AY60AJ2NA, RP15AY Endeavor Two Stage Heat Pump System, RP15AY, Endeavor Two Stage Heat Pump System, Stage Heat Pump System, Heat Pump System, Heat Pump

File Info : application/pdf, 12 Pages, 624.13KB