Ruud Endeavor® Line Achiever Plus® Series iM Heat Pumps
Model Series: RP15AY
Product Overview
The Ruud Endeavor® Line Achiever Plus® Series iM Heat Pumps (RP15AY) offer high-efficiency cooling and heating performance. These units feature two-stage operation for precise temperature control and enhanced comfort.
Key Specifications:
- Cooling Efficiencies: Up to 16 SEER2 / 11.7 EER2
- Heating Efficiencies: Up to 8.1 HSPF2
- Nominal Sizes: 1.5 to 5 Tons [5.3 to 17.6 kW]
- Cooling & Heating Capacities: 17.1 kBTU to 57 kBTU [5.0 to 16.7 kW]
- Refrigerant Type: R-454B
Note: Proper sizing and installation are critical for optimal performance. Consult with a qualified contractor.
This product meets ENERGY STAR® requirements when matched with appropriate coil components. For details, visit energystar.gov.
Features and Benefits
- Two-Stage Scroll Compressor: Provides two speeds (high and low) for cooling and heating, ensuring more precise temperature control, lower humidity, and greater efficiency compared to single-stage compressors.
- 7mm Condenser Copper Coil: Requires less refrigerant, resulting in a smaller and lighter footprint while enhancing reliability.
- Inverted Reversing Valve: Facilitates faster heat transfer with gravity assist shifting and reduced joint stress for increased reliability.
- PlusOne® Expanded Valve Space: Offers 3 in. – 4 in. – 5 in. service valve space, providing a minimum working area of 27 square inches for easier access during maintenance.
- PlusOne® Triple Service Access: Features a 15-inch wide access panel with two fasteners and removable corner and individual louver panels, making repairs faster and easier.
- PlusOne® Refrigerant Detection System™: An integrated, patented system with an A2L sensor and mitigation board for easier commissioning, simplified wiring, and system protection that pauses operation if excess refrigerant is detected.
- Designing for Sustainability with Low GWP: Utilizes R-454B refrigerant, which has a significantly lower Global Warming Potential (GWP) than previous refrigerants, aligning with environmental protection goals and delivering energy-efficient comfort.
Model Number Identification
The model number provides key information about the heat pump's specifications. The structure is generally:
R P 15 A Y [Capacity] J 2 N A
- R: Brand (Ruud)
- P: Product Category (Heat Pump)
- 15: SEER2 Rating (15.2 SEER2)
- A: Region (All Regions)
- Y: Refrigerant Type (R-454B)
- [Capacity]: Nominal capacity in thousands of BTU/h (e.g., 18 for 18,000 BTU/h, 60 for 60,000 BTU/h)
- J: Voltage (208/230/1/60)
- 2: Stage (2-Stage)
- N: Control Type (Non-Communicating)
- A: Series Designator
Available Models:
Model Number | Description |
---|---|
RP15AY18AJ2NA | Endeavor® Line Achiever Plus® Series 1.5 ton 15.2 SEER2 2-Stage Heat iM Pump-208/230/1/60 |
RP15AY24AJ2NA | Endeavor® Line Achiever Plus® Series 2 ton 15.2 SEER2 2-Stage Heat iM Pump-208/230/1/60 |
RP15AY30AJ2NA | Endeavor® Line Achiever Plus® Series 2.5 ton 15.2 SEER2 2-Stage Heat iM Pump-208/230/1/60 |
RP15AY36AJ2NA | Endeavor® Line Achiever Plus® Series 3 ton 15.2 SEER2 2-Stage Heat iM Pump-208/230/1/60 |
RP15AY42AJ2NA | Endeavor® Line Achiever Plus® Series 3.5 ton 15.2 SEER2 2-Stage Heat iM Pump-208/230/1/60 |
RP15AY48AJ2NA | Endeavor® Line Achiever Plus® Series 4 ton 15.2 SEER2 2-Stage Heat iM Pump-208/230/1/60 |
RP15AY60AJ2NA | Endeavor® Line Achiever Plus® Series 5 ton 15.2 SEER2 2-Stage Heat iM Pump-208/230/1/60 |
Standard Equipment:
- R-454B Refrigerant
- Scroll Compressor
- Field Installed Filter Drier
- Front Seating Service Valves
- Internal Pressure Relief Valve
- Internal Thermal Overload
- Long Line capability
- Low Ambient capability with Kit
- 3-4-5 Expanded Valve Space
- Composite Basepan
- 2 Screw Control Box Access
- 15" Access to Internal Components
- Quick release louver panel design
- No fasteners to remove along bottom
- Optimized Venturi Airflow
- Powder coated paint
- Rust resistant screws
- QR code [QR code symbol]
- External gauge ports
- Service trays
General Data and Electrical Specifications
Model No. | Nominal Tonnage | Liquid Line O.D. (in.) | Suction Line O.D. (in.) | Refrigerant (R-454B) furnished (oz.) | Compressor Type | Outdoor Coil Net Face Area (Outer Coil) | Outdoor Coil Net Face Area (Inner Coil) | Tube diameter (in.) | Number of rows | Fins per inch | Outdoor Fan Diameter (in.) | Number of blades | Motor hp | CFM | RPM | Watts | Shipping weight (lbs.) | Operating weight (lbs.) | |||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
RP15AY18A | 1.5 | 3/8 | 3/4 | 83 | 2-stage Scroll | 10.9 | 10.5 | 0.276 | 2 | 22 | 20 | 2 | 1/6 | 2582 | 1075 | 145 | 157 | 150 | |||||
RP15AY24A | 2.0 | 3/8 | 3/4 | 83 | 10.9 | 10.5 | 0.276 | 2 | 22 | 20 | 2 | 1/6 | 2582 | 1075 | 145 | 157 | 150 | ||||||
RP15AY30A | 2.5 | 3/8 | 3/4 | 85 | 19.5 | -- | 0.276 | 1 | 22 | 24 | 3 | 1/5 | 4077 | 850 | 222 | 209 | 202 | ||||||
RP15AY36A | 3.0 | 3/8 | 7/8 | 88 | 21.5 | -- | 0.276 | 1 | 22 | 24 | 3 | 1/5 | 4206 | 850 | 246 | 221 | 214 | ||||||
RP15AY42A | 3.5 | 3/8 | 7/8 | 130 | 21.5 | -- | 0.276 | 1 | 22 | 24 | 3 | 1/5 | 4206 | 850 | 246 | 247 | 240 | ||||||
RP15AY48A | 4.0 | 3/8 | 7/8 | 130 | 21.5 | -- | 0.276 | 1 | 22 | 24 | 3 | 1/5 | 4206 | 850 | 246 | 247 | 240 | ||||||
RP15AY60A | 5.0 | 3/8 | 7/8 | 234 | 23.4 | 22.7 | 0.276 | 2 | 22 | 26 | 3 | 1/5 | 4396 | 850 | 284 | 282 | 275 |
Electrical Data:
RP15AY18A | RP15AY24A | RP15AY30A | RP15AY36A | RP15AY42A | RP15AY48A | RP15AY60A | |
---|---|---|---|---|---|---|---|
Line Voltage Data (Volts-Phase-Hz) | 208/230-1-60 | ||||||
Maximum overcurrent protection (amps) | 20 | 25 | 30 | 30 | 40 | 45 | 50 |
Minimum circuit ampacity | 13 | 16 | 20 | 20 | 24 | 27 | 33 |
Compressor | |||||||
Rated load amps | 10 | 12 | 15 | 15 | 18 | 20 | 25 |
Locked rotor amps | 52 | 65 | 82 | 90 | 106 | 141 | 147 |
Condenser Fan Motor | |||||||
Full load amps | 0.8 | 0.8 | 1.2 | 1.2 | 1.2 | 1.2 | 1.2 |
Locked rotor amps | 1.5 | 1.5 | 2.6 | 2.6 | 2.6 | 2.6 | 2.6 |
Notes: Refrigerant charge is sufficient for 15 ft. of refrigerant lines. For longer line set requirements, consult installation instructions. HACR type circuit breaker or fuse is recommended. Refer to National Electrical Code for wire, fuse, and disconnect size requirements.
Accessories
MODEL NO. | RP15AY18A | RP15AY24A | RP15AY30A | RP15AY36A | RP15AY42A | RP15AY48A | RP15AY60A |
---|---|---|---|---|---|---|---|
Compressor crankcase heater* | 44-17402-44 | 44-17402-44 | 44-17402-44 | 44-17402-44 | 44-17402-44 | 44-17402-45 | Factory Standard |
Low ambient control | RXAD-A08 | RXAD-A08 | RXAD-A08 | RXAD-A08 | RXAD-A08 | RXAD-A08 | RXAD-A08 |
Compressor sound cover | 68-23427-26 | 68-23427-26 | 68-23427-26 | 68-23427-26 | 68-23427-26 | 68-23427-25 | 68-23427-25 |
Compressor hard start kit | SK-A1 | SK-A1 | SK-A1 | SK-A1 | SK-A1 | SK-A1 | SK-A1 |
Low pressure control | Factory Standard | Factory Standard | Factory Standard | Factory Standard | Factory Standard | Factory Standard | Factory Standard |
High pressure control | Factory Standard | Factory Standard | Factory Standard | Factory Standard | Factory Standard | Factory Standard | Factory Standard |
Liquid Line Solenoid Valve (24 VAC, 50/60 Hz) | 200RD2T3TVLC | 200RD2T3TVLC | 200RD2T3TVLC | 200RD2T3TVLC | 200RD2T3TVLC | 200RD3T3TVLC | 200RD3T3TVLC |
Solenoid Coil (24 VAC) | 61-AMG24V | 61-AMG24V | 61-AMG24V | 61-AMG24V | 61-AMG24V | 61-AMG24V | 61-AMG24V |
Liquid Line Solenoid Valve (120/240 VAC, 50/60 Hz) | 200RD2T3TVLC | 200RD2T3TVLC | 200RD2T3TVLC | 200RD2T3TVLC | 200RD2T3TVLC | 200RD3T3TVLC | 200RD3T3TVLC |
Solenoid Coil (120/240 VAC) | 61-AMG120/240V | 61-AMG120/240V | 61-AMG120/240V | 61-AMG120/240V | 61-AMG120/240V | 61-AMG120/240V | 61-AMG120/240V |
*Bi-flow kits are required when installing a liquid line solenoid on a heat pump.
Weighted Sound Power Level (dBA)
UNIT SIZE - VOLTAGE, SERIES | STANDARD RATING (dBA) | TYPICAL OCTAVE BAND SPECTRUM (dBA WITHOUT TONE ADJUSTMENT) | ||||||
---|---|---|---|---|---|---|---|---|
125 Hz | 250 Hz | 500 Hz | 1000 Hz | 2000 Hz | 4000 Hz | 8000 Hz | ||
RP15AY18A | 73 | 58.0 | 58.8 | 62.0 | 62.3 | 59.2 | 56.6 | 50.5 |
RP15AY24A | 73 | 56.6 | 59.6 | 62.2 | 62.1 | 58.8 | 55.4 | 50.8 |
RP15AY30A | 73 | 55.1 | 58.3 | 65.6 | 63.5 | 58.5 | 54.9 | 48.5 |
RP15AY36A | 74 | 51.2 | 56.4 | 63.1 | 63.8 | 60.8 | 57.4 | 56.5 |
RP15AY42A | 74 | 56.6 | 57.4 | 64.9 | 64.0 | 62.0 | 57.4 | 50.4 |
RP15AY48A | 74 | 57.3 | 57.0 | 64.1 | 64.0 | 61.1 | 58.0 | 56.5 |
RP15AY60A | 74 | 43.9 | 55.2 | 63.4 | 65.8 | 61.7 | 57.9 | 52.9 |
Note: Tested in accordance with AHRI Standard 270-08.
Unit Dimensions
MODEL NO. | OPERATING | SHIPPING | ||||
---|---|---|---|---|---|---|
H (Height) | L (Length) | W (Width) | H (Height) | L (Length) | W (Width) | |
INCHES | mm | INCHES | mm | INCHES | mm | INCHES | mm | INCHES | mm | INCHES | mm | |
RP15AY18A | 25.00 | 635 | 29.75 | 756 | 29.75 | 756 | 27.90 | 709 | 33.25 | 845 | 33.25 | 845 |
RP15AY24A | 25.00 | 635 | 29.75 | 756 | 29.75 | 756 | 27.90 | 709 | 33.25 | 845 | 33.25 | 845 |
RP15AY30A | 35.00 | 889 | 33.75 | 857 | 33.75 | 857 | 38.35 | 974 | 37.64 | 956 | 37.64 | 956 |
RP15AY36A | 39.00 | 991 | 35.75 | 908 | 35.75 | 908 | 40.50 | 1029 | 38.38 | 975 | 38.38 | 975 |
RP15AY42A | 39.00 | 991 | 35.75 | 908 | 35.75 | 908 | 40.50 | 1029 | 38.38 | 975 | 38.38 | 975 |
RP15AY48A | 39.00 | 991 | 35.75 | 908 | 35.75 | 908 | 40.50 | 1029 | 38.38 | 975 | 38.38 | 975 |
RP15AY60A | 39.00 | 991 | 35.75 | 908 | 35.75 | 908 | 40.50 | 1029 | 38.38 | 975 | 38.38 | 975 |
Clearances
Proper clearances are essential for optimal performance and serviceability. The following minimum clearances are recommended:
- Service Access: 24 inches (609.6 mm)
- Side Clearance: 6 inches (152.4 mm)
- Top Clearance: 12 inches (304.8 mm)
- Front Clearance: 24 inches (609.6 mm) recommended, 6 inches (152.4 mm) minimum.
- Overall Unit Clearance: Allow 60 inches (1524 mm) of clearance around the unit.
Important: When installing multiple units in an alcove, roof well, or partially enclosed area, ensure adequate ventilation to prevent re-circulation of discharge air.
Refrigerant Line Size Information
This section provides detailed guidelines for selecting appropriate refrigerant line sizes based on unit capacity, equivalent length, and maximum vertical separation. These tables are crucial for ensuring optimal system performance and efficiency. They cover various combinations of liquid and suction line sizes for different unit tonnages and equivalent lengths up to 250 feet (76 meters).
Note: Light grey shaded areas in the original tables indicate conditions considered "long line" and may require specific accessories. Consult the Long Line Set Guide for details. Avoid using suction line traps in the suction riser as they can increase pressure drop.
Performance Data @ AHRI Standard Conditions - Cooling
OUTDOOR UNIT | AIR HANDLER | TOTAL CAPACITY BTU/H [kW] | NET SENSIBLE BTU/H [kW] | NET LATENT BTU/H [kW] | SEER2 | EER2 | INDOOR CFM [L/S] | 47 DEGREE HEATING CAPACITY BTU/H [KW] | 47 DEGREE COP | 17 DEGREE HEATING CAPACITY BTU/H [KW] | 17 DEGREE COP | REGION HSPF2 |
---|---|---|---|---|---|---|---|---|---|---|---|---|
RP15AY18AJ2N | RH2TY2417STANN | 17,100 [5.0] | 13,100 [3.8] | 4,000 [1.2] | 15.2 | 11.7 | 625 [295.0] | 17,100 [5.0] | 3.60 | 10,000 [2.9] | 2.40 | 7.8 |
RP15AY24AJ2N | RH2TY2417STANN | 22,800 [6.7] | 17,500 [5.1] | 5,300 [1.6] | 15.2 | 11.7 | 775 [365.8] | 22,600 [6.6] | 3.60 | 14,000 [4.3] | 2.50 | 7.8 |
RP15AY30AJ2N | RH2TY3617STANN | 28,600 [8.4] | 21,900 [6.4] | 6,700 [2.0] | 15.2 | 11.7 | 950 [448.4] | 28,600 [8.4] | 3.40 | 18,000 [5.3] | 2.40 | 7.8 |
RP15AY36AJ2N | RH2TY3617STANN | 34,200 [10.0] | 26,200 [7.7] | 8,000 [2.3] | 15.2 | 11.7 | 1,050 [495.5] | 33,200 [9.7] | 3.10 | 22,200 [6.9] | 2.50 | 7.8 |
RP15AY42AJ2N | RH2TY4821STANN | 40,000 [11.7] | 30,700 [9.0] | 9,300 [2.7] | 15.2 | 11.7 | 1,300 [613.5] | 40,000 [11.7] | 3.60 | 25,000 [7.3] | 2.50 | 7.8 |
RP15AY48AJ2N | RH2TY4821STANN | 45,500 [13.3] | 34,900 [10.2] | 10,600 [3.1] | 15.2 | 11.7 | 1,450 [684.3] | 44,000 [13.0] | 3.60 | 29,600 [8.6] | 2.50 | 7.8 |
RP15AY60AJ2N | RH2TY6024STANN | 57,000 [16.7] | 43,700 [12.8] | 13,300 [3.9] | 15.2 | 11.7 | 1,800 [849.5] | 55,000 [16.1] | 3.60 | 32,000 [10.0] | 2.50 | 7.8 |
Note: This data includes DTC (Designated Test Combination) ratings for reference. Official ratings and system match-ups are available from the AHRI website (ahridirectory.org).
General Terms of Limited Warranty
Ruud provides a limited warranty, offering replacement for any part of this product that fails in normal use and service within the applicable period.
- Conditional Parts Warranty: Ten (10) Years (Registration Required).
For complete details on Limited and Conditional Warranties, including applicable terms and conditions, contact your local contractor or the Manufacturer.