User Manual for ibx instruments models including: ULTR Ultrasonic Bath with Heater and Timer, ULTR, Ultrasonic Bath with Heater and Timer, Bath with Heater and Timer, Heater and Timer, Timer
2 User Manual ULTR Ultrasonic bath with heater and timer Preface Users should read this Manual carefully, follow the instructions and procedures, and beware of all the cautions
File Info : application/pdf, 9 Pages, 440.15KB
DocumentDocumentULTR Ultrasonic bath with heater and timer Please read the User Manual carefully before use and follow all operating and safety instructions! User manual english User Manual ULTR Ultrasonic bath with heater and timer Preface Users should read this Manual carefully, follow the instructions and procedures, and beware of all the cautions when using this instrument. Service When help is needed, you can always contact the Service Department of manufacturer for technical support: www.labbox.com / e-mail: info@labbox.com Please provide the customer care representative with the following information: · Serial number · Description of problem · Your contact information Warranty This instrument is warranted to be free from defects in materials and workmanship under normal use and service, for a period of 24 months from the date of invoice. The warranty is extended only to the original purchaser. It shall not apply to any product or parts which have been damaged on account of improper installation, improper connections, misuse, accident or abnormal conditions of operation. For claim under the warranty please contact your supplier. 2 Applications: Electronic factory, Car workshops, Industrial and mining area, Laboratories, Hospitals, Dental clinics, Watch shop, Optical shops, Jewelry shops, Mobile phone repair shops, and household use. CAUTIONS Thank you for purchasing the ultrasonic cleaner. Please read the instruction manual carefully before operation to avoid damage to the machine or any danger to personal safety. · Ensure the power supply is within the rated range before connecting the power cable. Refitting is strictly prohibited! Attention that the control panel will be eroded by organic solution, strong acid and strong alkali. · Ensure the earth wiring is well connected before starting. · Ensure the power key or knob is on the `OFF' place before starting. · Do not operate if the tank is empty, or ultrasonic generator will be damaged If heating is needed, the water level should not be less than 2/3 · Please close the lid to reduce noise and be cautious of water and steam to avoid burns when opening the lid · Do not relocate the machine when fluid in the tank in case of overflow. · Suggest using water-soluble liquid for bench top ultrasonic cleaners. Strong acid or flammability cleaner is forbidden. · Do not use the machine in severe environment: o The place where temperature changes fiercely. o The place where humidity is too high and is easy to produce dew. o The place where vibration or impact is strong. o The place where exists corrosive gas or dust. o The place where water, oil or chemicals splash. o The place where is filled with explosive and flammable gas. · Shorten the daily working time. Suggestion is to stop for a few minutes for heat dissipation after working over 30 minutes. Heater is forbidden when using flammable liquid(such as alcohol, solvent cleaner etc.) to clean objects. 3 PRODUCT PRESENTATION 4 OPERATION PROCEDURE Before starting the equipment, check the machine to see if there is loosen parts. Keep the unit on a stable and flat working platform in dry and cool environment. According to the size and quantity of washing objects, add little bit detergent in the tank which can help improve the cleaning effect. (Empty tank working is forbidden!) Ensure correct power and switch connect before starting the equipment. · Operation Instructions: (Mechanical models) o Start (ULTRASONIC), clockwise rotate to choose the time you required between O30 min. When the indicator light is on and make "ZIZI" sound, it shows ultrasonic operation work OK. o If need heating, start(HEATING) to adjust required temperature, normally 40 60 .(Heating is optional upon needs). o To stop cleaning. 1. Press OFF once, the ultrasonic should stop running, the indicator light will also be off. 2. Rotate the heating control knob to "OFF" the indicator light will also be off. 3. Then switch off the unit and disconnect the power. 4. Empty out the liquid and clean the tank and the unit with clean cloth for next use. o Operation Instructions: (Digital models) o Timer setting: When power is connected, the default setting is "5:00 " .Press TIME+ once will increase time by 1 min; Press TIME+ once will decrease time by 1 min.( Free choice and digital countdown control). o Temperature setting: (heating is optional upon needs):When power is connected, the default setting is "50" and Actual is room temp, press TEMP+ once, will increase temperature by 1; Press TEMP- once, will decrease temperature by 1. If the setting temperature is lower than the actual tank temperature, the operation will stop automatically. When the temperature rises to the setting temperature, the indicating light goes off. When ultrasonic work, two temperature screen shows set temperature and actual temperature has been reached. o SEMIWAVE: Please open this function when ultrasonic is working, and it will be working by half wave form. Press this SEMIWAVE button again,then it will be turned off. o DEGAS Please open this function when ultrasonic is working, that is open 10 seconds, stop 5 seconds. Press DEGAS button again, then it will be turned off. SEMIWAVE & DEGAS function just only effective when ultrasonic is working) o After set the time and temperature, press ON/OFF once, the equipment will work automatically. Press ON/OFF again, the work process will stop. Then switch off the unit and disconnect the power supply, empty out the liquid and clean the tank and the unit with clean cloth for next use. · Adjusting power: o The function is only available for models with adjustable power! Rotate SLOWLY the power knob clock-wise to increase the power from 40% to 100%, and counter-clockwise SLOWLY is to decrease sonic power. 5 MAINTENANCE The unit must be opened by authorized specialized person only for maintenance and care of it. · Clean the contaminant in the tank frequently. · Trouble clearing: Problem No ultrasonic Time control failure No heating Temperature control failure Not well cleaning Possible Causes Solutions Remarks A. Power supply not connected. B. Fuse broken. C. Cable short circuit. D. Transducer short circuit. E.PCB Board broken. F. Other reasons ATimer knob out of control BTimer failure COther reasons AHeater power switch bad linkage B.Fuse burn out C Heating pad burn out DDigital display board out of control E Other reasons AThermostat loosen BThermostat tube broken C Digital display out of control D Other reasons A Not strong ultrasonic cleaning B Too high too low liquid surface C Too high too low temperature A. Check and plug pow switch. BCheck the fitted power supply and change the same specification fuse. C. Connect fitted cable or replace a new DInquiry our after-service engineer ECheck the broken part and change it. FInquiry our after-service engineer. ALoosen or tighten the screw. BReplace timer or digital panel. CInquiry our after service engineer. ACheck heating plug and connect well, Check outlet line with multimeter: if OK and resistance value is few hundred OHMs.. BChange the same specification fuse. C Replace the bad heating pad if open circuit. D Check the broken part and change it E Inquiry our after service engineer. AFasten the thermostat header BReplace thermostat. CCheck the broken part and change it. DInquiry our after service engineer. A Connect ultrasonic button and adjust. B Adjust liquid into the best surface. C Adjust temperature into the most fitted. Suggestion 50-60 Suggestion 50-60 D Not suitable cleaning liquid D Stop and switch off power supply, replace suitable liquid 6 Electric leakage E Other reasons after the liquid cool down. E Inquiry our after service engineer. A.Customer side not grounded B.Machine not grounded A To ensure grounded. B Check if machine earth wire loosen. APPLICATION Industry Semi-conductor Electrical& electronic machine Precision machine Optical device Hardware & machinery parts Medical instrument Electroplate Car parts Chemical fiber The cleaning products and material Clear dirt Integrated circuit, power tube, silicon Hards, etching oil, stamping oil, wafer, diode, lead frame, capillary, polishing wax, dust particles, etc tray, etc. Tube parts, cathode ray tube, printed Fingerprint, powder, cutting circuit board, oil, stamping oil, iron filings, quartz parts, electronic components, polishing materials, walnut telephone powder, polishing wax, resin, switching equipment, speaker dust, etc components, power meter, LCD glass, core iron parts, computer floppy disk, video parts hoop parts, head, photo die mask, etc Bearing, sewing machine parts, typewriter, textile machine, optical mechanical device, gas valve, watches, cameras, metal filter element, etc. Glasses, lens, prism, optical lens, filter lens, glass device, film, optical fiber, etc Bearing, gear, ball, metal shaft parts, tools, adjustable valve and cylinder parts, burner, compressors, hydraulic press, gun and ultracentrifuge, city water faucet, etc Medical instrument, denture, etc Galvanized partsmold, stamping parts, etc Piston ring, carburetor, flow meter housing, compressor shell, electrical components, etc Chemical or artificial fiber nozzle filter protector chemical fiber texture, etc Machine cutting oil, iron filings, polishing powder, fingerprint, 011, grease, dirt, etc. Plastic, resin, paraffin, finger printing, etc Cutting oil, iron filings, grease, polishing powder, finger printing and so on Iron filings, polishing powder, oil, stamping oil, dirt, etc. Polishing scrap iron, oil, black iron shell, rust, oxidation shell, scrap iron, polishing powder, stamping oil, dirtetc. Chemical colloid, glue, and other solid material, dust, etc 7 . 8 www.labbox.com