DSC PC4020 Maxsys Wiring Uplink's Cellular Communicators and Programming the Panel CAUTION: · It is advised that an experienced alarm installer programs the panel as further programming may be required to ensure proper performance and use of the full functionality. · Do not route any wiring over circuit board. · Full panel testing, and signal confirmation, must be completed by the installer. NEW FEATURE: For Uplink Communicators, the status of the panel can be retrieved not only from the status PGM but now also from the Open/Close reports from the dialler. Therefore, wiring the white wire and programming of the status PGM of the panel is optional. IMPORTANT NOTE: The Open/Close reporting needs to be enabled during the initial pairing procedure. Wiring the 5530M communicators to DSC PC4020 Maxsys 1 of 3 Wiring and Programming Uplink Communicators to DSC PC4020 Maxsys Programming the DSC PC4020 Maxsys Alarm Panel via the Keypad Enable Contact ID reporting: Keypad Display Date & Time Select (00) - System Area Select (00) - Add/Edit Par Select (00) - Partition 1 Select (00) - Partition Acc. # Partition Acct. # - Enter Hex Select (00) - Partition Acc. # Select (00) - System Area Select (00) - Installer Opt's Select (00) - Main Items Select (00) - 1st Number System Account# - Enter Hex Select (10) Closings User 001 Closing Select (11) - Misc Closings Closing Select (13) Openings User 001 Opening Select (14) - Misc Opening Opening Select (00) - 1st Number Select (00) - Pgm. Tel Number Enter(31 max) Tel Number D___________ Select (00) - Pgm. Tel Number Select (00) - DTMF Contact ID Select (00) - Pgm. Tel Number Select Toggle - Alarm/Restore Select Toggle - Open/Close Select Toggle - All Others Keypad Entry *84020 01 00 01 * 1234 ## 00 04 00 03 1234# 03 10 *12# Action Description To enter Programming Mode To enter Partition Area To enter Add/Edit Partition To enter Partition 1 account number To select the menu Enter the account number (1234 is an example) To exit to the main menu To enter System Area To select Communicator To select Main Items To go to System Account Number Enter the same account number as you entered for Partition 1 above To enter Reporting Codes in case of CID format Define Closing by user Reporting Code for Closing 11 Define Misc Closing for Keyswitch reporting *12# Reporting Code for Misc Closing 13 *12# Define Opening by user Reporting Code for Opening 14 Define Misc Opening for Keyswitch reporting *12## 00 00 00 123456# 01 02 02 * > * > * # # # Reporting Code for Misc Opening To go to Program Telephone Number To select 1st phone number To go to phone number Enter phone number (123456 is an example) # to go back To go to Communicator Format To select DTMF Contact ID To go to Dialer Direction Press * until Y (Yes), press > to move to next option Press * until Y (Yes), press > to move to next option Press * until Y (Yes), press # # to go back to Main Items 2 of 3 Select (00) - Main Items Select Toggle - Comms. Enabled Select Toggle - DTMF Dialing Select Toggle - TLM Enabled Wiring and Programming Uplink Communicators to DSC PC4020 Maxsys 01 To go to Communication Toggles * > Press * until Y (Yes), press > to move to next option * > Press * until Y (Yes), press > until you find "TLM Enabled" * > Press * until N (No), press > until you find "6 Digit account" Program Keyswitch zone and output: Keypad Display Keypad Entry Action Description Date & Time *84020 To enter programming mode Select (00) - System Area 01 To enter Partition area Select (00) - Add/Edit Par 00 To enter Add/Edit Partition Select (00) - Partition 1 01 To enter Partition 1 Select (00) - Partition Acct. # 03 To enter Zone Assignment Select (00) - Add New Zone 01 To Edit Zones (00 to add Zone) Select (001) - Zone 1 001* To enter Zone 1 Select (00) - Zone Label 01 To go to Zone type Select (00) - Momentary Arm 25 To select Momentary Arm Select (00) Zone Label ##### Press # until you go back to the Main Menu Select (00) - System Area 00 To enter System Area Select (00) - Installer Opt's 02 To go to System Options Select (00) - System Toggles 04 To go to Zone Supervision Select (01) - Single EOL 01 To select Single EOL option, press > until you find "Single EOL" Select (00) - System Toggles ## To go back to previous section Select (00) - Installer Opt's 07 To go to PGM Outputs Select (00) - Main PGM 1 Out 00 To select PGM 1 Select (00) - Inv. Arm Status 07 To select Inv. Arm Status Select (00) - Partition 1 * # Press * until Y (Yes), press # until you exit programming mode Select Toggle * # # # Press * until N (No), press # until you exit the Programming Menu NOTE: TO PROGRAM THE DESIRED REPORTING CODES - *84020, 00, 04, 03 From programming mode (*84020) type 00 to go to System Area, followed by 04 (Communicator), followed by 03 (Reporting Codes). Program the desired reporting codes in the corresponding fields from 00 to 16. 3 of 3Microsoft Word for Microsoft 365