Instruction Manual for DELTA models including: EBSU-CE2818SX1 PP0Y LFP Battery Container, EBSU-CE2818SX1, PP0Y LFP Battery Container, LFP Battery Container, Battery Container
Nov 22, 2024 — Delta's LFP battery container is designed for grid-scale and medium to large-scale industrial energy storage applications. Built on a.
Products - Energy Storage Systems - Delta EMEA
Delta's LFP battery container is designed for grid-scale and medium to large-scale industrial energy storage applications. Built on a standard 10-ft ...
File Info : application/pdf, 6 Pages, 4.32MB
DocumentDocumentEnergy Storage Solution LFP Battery Container Compact design of standard 10-ft shipping container for easy transportation and installation Built-in fire protection system, compliant with UL 9540A safety test standard Battery system with built-in controls, offering flexible scalability from 708 kWh to 7.78 MWh Ancillary Services Solar Plus Storage Energy-Heavy Industries Microgrids Fully-Integrated Battery Solutions Redefining Safety and Performance with Effortless Installation, Remarkable Scalability, and Integrated Fire Protection System Delta's LFP battery container is designed for grid-scale and medium to large-scale industrial energy storage applications. Built on a standard 10-ft shipping container with compact design and simple installation procedure, the battery system can be rapidly deployed. LFP battery container is high energy density, offering scalability from 708 kWh to 7.78 MWh. This flexibility allows it to accommodate varying spatial and capacity requirements for different sites, optimizing land utilization. In addition, LFP battery container features redundant communication support for the installation site with built-in controls, enhancing the communication stability of the energy storage system. It also incorporates several sensors and a fire protection system to ensure the safety of the energy storage system. Features High Energy Density with Flexible and Scalable Configuration High energy density, effectively utilizing space Flexible configuration ranging from 708 kWh to 7.78 MWh battery capacity Built-in Fire Protection System Enhancing Inherent Safety Real-time cell monitoring: temperature and voltage of each cell Dual-redundant environmental sensors: smoke, heat, humidity, flammable gas, and flood Fire protection system: detection system, gas venting system, aerosol fire extinguisher and fire sprinkler system Easy Transportation and Installation Whole-container transport without the need to remove battery modules Containers connected by flexible duct connectors on the top, tolerating positioning errors and reducing on-site installation time Integrated Control and Monitoring Built-in controls seamlessly integrate batteries and PCSs without the need for additional equipment and space Built-in Human-Machine Interface (HMI): on-site access to real-time field information Dual-redundant communication enhanced of communication stability and monitoring efficiency Product Configuration and Design Battery System Battery Zone Container Connector · Flexible duct connector design for flexible installation · Quick installation of busbars, auxiliary power cables and communication cables Embedded HVAC · Built-in air conditioning system for optimal thermal management · Installation of additional cooling equipment is not required, saving both space and cost Battery Container Quick Wiring Design · On-site work can be performed without opening containers to avoid the risk of exposure to water vapor and foreign particles · Simplified wiring allows for shorter work duration, allowing for cost savings AIO (All-In-One) Container Auxiliary Power and Control Zone DC Power Distribution Zone Reinforced Storage Container · Three-layer structure composed of double steel plate and fireproof rock wool boards (fire retardant up to 60 minutes) · Cables and wires in accordance with IEC 6033 · IEEE 693 Recommended Practice for Seismic Design of Substations · Corrosion protection according to ISO 12944 C5M (C5H optional) · Access control for vandalism prevention Battery Container 1.4 MWh Battery Container Redundant Detection System · Smoke detectors · Flammable gas detectors · Heat detectors · Door sensors · Flood detectors · Humidity sensors Battery Module Protetcion · Real-time monitoring of each battery cell · Big data for aging/abnormality detection · Insulation design of battery module · Built-in fuse · Cell balancing mechanism Fire Safety Protection · Gas venting system · Aerosol fire extinguisher · Fire sprinkler system · Fire alarm siren & strobe Safety Certification · UL 9540A · UL 1973 · IEC 62619 including fire propagation · UN 38.3 · IEC 60730 · IEC 61000 -6-2/ -6-4 · IEC 62477 · CE / UKCA Mark Software Interface Human Machine Interface (HMI) Easy Commissioning On-site view of real-time information on the battery system Real-Time Monitoring Operation information, environment status, UPS status, warnings, and battery information (e.g. SoC, SoH, voltage, current, temperature), etc Convenient Maintenance Service mode option enables technicians to maintain the battery system easily Battery Management System (BMS) Clear Overview of Battery Status Intuitive UI for real-time display of battery string parameters Quick Diagnosis and Debugging Easy access to error codes, database, daily logs, and entry records System Overview Battery Analysis Reports Specifications Type Type Model Name Installed Capacity Rated Power Battery Cell DC Voltage Range String Configuration Modules per String Max. Charge/Discharge Current Recommended DoD Auxiliary Power Communication Interface Communication Protocol Environment Environment Condition Altitude Operating Temperature Ambient Humidity Storage Temperature Ingress Protection Corrosion Resistance Container Standard Seismic Level Operation Measurement Accuracy HMI BMS Log BMS Power Backup Time Calibration Safety Protection Fire Safety Equipment Detection Sensors (per Container) Mechanical Information Dimension (W x D x H) Weight Single Container (IEC Version) AIO Battery EBSU-CE2818SX1 PP0Y1 EBSB-CE2818SX1 PS0Y1 0 to 1416 kWh LFP 280 Ah Cell 1089 to 1386 Vdc EBSB-CE2818S3PP0Y1 EBSB-CE2818S4PP0Y1 396S-1P 18 3080 A 95% 220/380 Vac (3P4W) ±5% Ethernet Modbus Battery System (IEC Version) EBSU-CE2818SX2 PP0Y1 EBSB-CE2818SX2 PS0Y1 1770 kWh to 7788 kWh 757 kW to 3333 kW Outdoor < 2000m -30 to +50 0 to 100 % RH (non-condensing) 1 month: -20 to +45 , <70% RH ; 1 year: 0 to +35 , <70% RH IP54; Type 3R, NEMA 3R compliance Compliant with Severity-1 (IEC 60068-2-52); Passed 720-hour salt mist test (ISO 9227), ISO 12944 Level C5M ISO 668 IEEE 693 (0.5 G, 2% damping) Voltage: ±0.5 %; Current: ±1 % ; Temperature: ±2 ; SoC: 5 % For monitoring and maintenance 90 days UPS power backup for 60 minutes NTP time synchronization Gas-venting system, aerosol fire extinguisher and fire sprinkler system Heat (x2), smoke (x2), gas (x2), flood (x2), humidity (x4), door (x4) 2438 × 2990 × 2896 mm (per Container) AIO Container: 12,000 kg (with 2 battery strings) Battery Container: 16,000 kg (with 4 battery strings) * Where X1 can be 0,1,2, which indicates the number of battery strings. * Where X2 can be a number from 5 to 22, which indicates the number of battery strings. * Where Y1 is a serial number indicating the battery system version. Delta Electronics More Information 16 Tungyuan Road, Chungli Industrial Zone, Taoyuan City 32063, Taiwan TEL: +886 3 4526107 EISBG.Marketing@deltaww.com www.deltaww.com Specifications are subject to change without prior notice. Please refer to the actual product purchased, and the latest version can be obtained from sales channels. 2024 / 09