Owner's Manual for MEAN WELL models including: RPS-45-3.3, RPS-45-5, RPS-45-7.5, RPS-45-12, RPS-45-15, RPS-45-24, RPS-45-48, RPS-45 series 45W Reliable Green Medical Power Supply, RPS-45 series, 45W Reliable Green Medical Power Supply, Green Medical Power Supply, Power Supply, Supply
MEAN-WELL USA, INC. - РКС Компоненти - РАДІОМАГ
File Info : application/pdf, 4 Pages, 149.28KB
DocumentDocument45W Reliable Green Medical Power Supply RPS-45 series User's Manual EN 60601-1 IEC 60601-1 8 ANSI/AAMI ES60601-1 BS EN/EN60601-1 IEC60601-1 TPTC004 Features 3"×2" compact size Medical safety approved (2 x MOPP) according to ANSI/AAMI ES60601-1 and IEC/BS EN/EN60601-1 Suitable for BF application with appropriate system consideration Cooling by free air convection EMI class B for class configuration No load power consumption<0.1W Extremely low leakage current Protections: Short circuit / Overload / Over voltage Lifetime > 50K hours Operating altitude up to 4000 meters 3 years warranty ++ Applications Oral irrigator Hemodialysis machine Medical computer monitors Sleep apnea devices GTIN CODE MW Search: https://www.meanwell.com/serviceGTIN.aspx Description RPS-45 is a 45W highly reliable green PCB type medical power supply with a high power density on the 3" by 2" footprint. It accepts 80~264VAC input and offers various output voltages between 3.3V and 48V. The working efficiency is up to 91% and the extremely low no load power consumption is down below 0.1W. RPS-45 is able to be used for Class(no FG) system design. The extremely low leakage current is less than 100A. In addition, it conforms to international medical regulations (2*MOPP) and EMC BS EN/EN55011, perfectly fitting all kinds of BF rated "patient contact" medical system equipment. Model Encoding RPS- 45 - 3.3 Output voltage Rated wattage Series name Downloaded from Arrow.com. File Name:RPS-45-SPEC 2024-02-23 45W Reliable Green Medical Power Supply RPS-45 series SPECIFICATION ORDER NO. RPS-45-3.3 RPS-45-5 RPS-45-7.5 RPS-45-12 RPS-45-15 RPS-45-24 RPS-45-48 DC VOLTAGE 3.3V 5V 7.5V 12V 15V 24V 48V RATED CURRENT CURRENT RANGE 8A 0 ~ 8.8A 8A 0 ~ 8.8A 5.4A 0 ~ 5.95A 3.8A 0 ~ 4.18A 3A 0 ~ 3.3A 1.9A 0 ~ 2.1A 0.94A 0 ~ 1.03A OUTPUT RATED POWER 26.4W PEAK LOAD(10sec.) Note.2 29W RIPPLE & NOISE (max.) Note.3 60mVp-p VOLTAGE ADJ.RANGE 3.1~3.6V VOLTAGE TOLERANCE Note.4 ±2.0% LINE REGULATION ±0.5% LOAD REGULATION ±2.0% 40W 44W 60mVp-p 4.7~5.5V ±2.0% ±0.5% ±2.0% 40.5W 44.6W 80mVp-p 7.12~8.3V ±2.0% ±0.5% ±2.0% 45.6W 50.2W 100mVp-p 11.4~13.2V ±2.0% ±0.5% ±2.0% 45W 49.5W 100mVp-p 13.5~16.5V ±1.0% ±0.5% ±1.0% 45.6W 50.2W 120mVp-p 22.8~27.6V ±1.0% ±0.5% ±1.0% 45.1W 49.4W 120mVp-p 45.6~52.8V ±1.0% ±0.5% ±1.0% SETUP, RISE TIME 500ms, 30ms / 230VAC 500ms, 30ms / 115VAC at full load HOLD UP TIME (Typ.) 30ms / 230VAC 16ms / 115VAC at full load VOLTAGE RANGE Note.5 80 ~ 264VAC FREQUENCY RANGE 47 ~ 63Hz INPUT EFFICIENCY (Typ.) 80.5% 83% 85% 88% 89% 90% 91% AC CURRENT (Typ.) 1.2A / 115VAC 1A / 230VAC INRUSH CURRENT (Typ.) OLD STAR 30A/115VAC 60A/230VAC LEAKAGE CURRENT(max.) Note.6 Touch current< 100A/264VAC OVERLOAD 115 ~ 150% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed PROTECTION OVER VOLTAGE 3.8~5V 5.7~6.8V 8.6~11.3V 13.8~16.2V Protection type : Shut down o/p voltage, re-power on to recover 17.2~20.3V 28.4~32.4V 55.2~64.8V WORKING TEMP. -30 ~ +70 (Refer to "Derating Curve") WORKING HUMIDITY 20% ~ 90% RH non-condensing ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +85, 10 ~ 95% RH non-condensing TEMP. COEFFICIENT ±0.03% / (0 ~ 50) VIBRATION 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes OPERATING ALTITUDE Note.7 4000 meters SAFETY STANDARDS IEC60601-1, TUV BS EN/EN60601-1, EAC TP TC 004,UL ANSI / AAMI ES60601-1 (3.1 version), CAN/CSA-C22.2 No. 60601-1:14 - Edition 3 approved;Design refer to BS EN/EN60335-1 ISOLATION LEVEL Primary-Secondary: 2xMOPP WITHSTAND VOLTAGE I/P-O/P: 4KVAC ISOLATION RESISTANCE I/P-O/P:100M Ohms / 500VDC / 25/ 70% RH Parameter Standard Test Level / Note Conducted emission BS EN/EN55011 (CISPR11) Class B SAFETY & EMC EMISSION Radiated emission BS EN/EN55011 (CISPR11) Class B EMC (Note. 8) Harmonic current Voltage flicker BS EN/EN61000-3-2 BS EN/EN61000-3-3 Class A ----- BS EN/EN55035, BS EN/EN60601-1-2 Parameter Standard Test Level / Note ESD BS EN/EN61000-4-2 Level 4, 15KV air ; Level 4, 8KV contact RF field susceptibility BS EN/EN61000-4-3 Level 3, 10V/m( 80MHz~2.7GHz ) Table 9, 9~28V/m( 385MHz~5.78GHz ) EMC IMMUNITY EFT bursts Surge susceptibility BS EN/EN61000-4-4 BS EN/EN61000-4-5 Level 3, 2KV Level 4, 2KV/Line-Line Conducted susceptibility BS EN/EN61000-4-6 Level 3, 10V Magnetic field immunity BS EN/EN61000-4-8 Level 4, 30A/m Voltage dip, interruption BS EN/EN61000-4-11 100% dip 1 periods, 30% dip 25 periods, 100% interruptions 250 periods MTBF 3334.3K hrs min. Telcordia SR-332 (Bellcore) ; 726.2K hrs min. MIL-HDBK-217F (25) OTHERS DIMENSION (L*W*H) 76.2*50.8*24mm or 3" * 2" *0.945" inch PACKING 0.11Kg; 120pcs/14.2Kg/0.94CUFT 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. 33% Duty cycle maximum within every 30 seconds. Average output power should not exceed the rated power. 3. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1f & 47f parallel capacitor. 4. Tolerance : includes set up tolerance, line regulation and load regulation. 5. Derating may be needed under low input voltages. Please check the derating curve for more details. NOTE 6. Touch current was measured from primary input to DC output. 7. The ambient temperature derating of 3.5/1000m with fanless models and of 5/1000m with fan models for operating altitude higher than 2000m(6500ft). 8. The power supply is considered a component which will be installed into a final equipment. "All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness." The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to "EMI testing of component power supplies." (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf ) Product Liability DisclaimerFor detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx Downloaded from Arrow.com. File Name:RPS-45-SPEC 2024-02-23 45W Reliable Green Medical Power Supply RPS-45 series Block Diagram EMI FILTER RECTIFIERS POWER I/P & & SWITCHING RECTIFIER FILTER O.L.P. CONTROL Derating Curve 100 80 60 50 40 20 -30 0 10 20 30 40 50 60 70 (HORIZONTAL) AMBIENT TEMPERATURE () Static Characteristics 100 90 80 70 60 50 40 80 100 115 120 140 160 180 200 220 240 264 INPUT VOLTAGE (V) 60Hz fosc : 65KHz RECTIFIERS +V & FILTER -V DETECTION CIRCUIT O.V.P. LOAD (%) LOAD (%) Downloaded from Arrow.com. File Name:RPS-45-SPEC 2024-02-23 45W Reliable Green Medical Power Supply RPS-45 series Mechanical Specification 3.175 Top View 76.2 69.85 3.175 50.8 44.45 FS1 3 2 1 CN1 AC FUSE T2A/250V HS1 HS100 CN2 1 2 3 4 LED SVR1 4-3.2 Case No. Unit:mm 3 max. 24 Side View AC Input Connector (CN1) : JST B3P-VH or equivalent Pin No. Assignment Mating Housing Terminal 1 AC/N 2 No Pin JST VHR or equivalent JST SVH-21T-P1.1 or equivalent 3 AC/L DC Output Connector (CN2) : JST B4P-VH or equivalent Pin No. Assignment Mating Housing Terminal 1 +V 2 +V 3 -V JST VHR JST SVH-21T-P1.1 or equivalent or equivalent 4 -V Installation Manual Please refer to : http://www.meanwell.com/manual.html Downloaded from Arrow.com. File Name:RPS-45-SPEC 2024-02-23