Owner's Manual for LIGHTRONICS models including: AS62D 6 X 1200W Compact Dmx Dimmer, AS62D, 6 X 1200W Compact Dmx Dimmer, Compact Dmx Dimmer, Dmx Dimmer, Dimmer
Lightronics Lighting Control - Portable Dimmers - AS Series AS62D
File Info : application/pdf, 6 Pages, 547.90KB
DocumentDocumentAS62D 6 X 1200W COMPACT DMX DIMMER OWN ER'S M AN U AL Version 1.1 06/01/2022 Version 1.1 AS62D COMPACT DMX DIMMER OWNER'S MAN UAL Page 2 of 6 06/01/2022 DESCRIPTION The AS62D is a compact six channel light dimmer. It has a maximum capacity of 1200 Watts per channel and maximum total load capacity of 4800 Watts. It is supplied with two input power cord stubs which may be connected to two different 120 VAC power phases. The AS62D is intended for INDOOR USE ONLY. The unit operates using the USITT DMX-512 protocol or an industry standard three wire multiplex protocol. The AS62D may be operated in a relay (non-dim) mode. The unit will also function as a chaser and has several preset chase patterns which may be used. I N ST ALLAT I ON LOCATION: Locate the unit vertically with control signal connectors on bottom in a well ventilated area away from moisture and heat. Two ½" holes are provided on the dimmer top cover to install a lighting bar pipe clamp and a suitable safety cable. FOR DMX-512 OPERATION: The male five pin XLR connector on the unit end panel connects to the control console. The female connector is for connection to additional dimmers. The AS62D dimmer is compatible with the USITT DMX-512 protocol. If both multiplex and DMX signals are available to the unit - it will automatically lock on to the DMX signal. Note that the DMX standard does not provide for console power via the dimmer chain. Therefore the DMX console used with AS62D dimmers must be powered by other means. CONTROL SIGNAL WIRING Connector Pin # 1 2 3 4 5 Multiplex LMX Common Console Power Multiplex Signal Not Used Not Used DMX DMX Common DMX Data DMX Data + Not Used Not Used AS62D END VIEW POWER CONNECTIONS: Extending from the chassis are two 20 amp line cords for connection to two separate 120 VAC, 20 Amp, grounded services in any phase combination. Total capacity of the AS62D is 4800 Watts. LOAD CONNECTIONS: There are six numbered duplex outlets on the top of the unit. Each provides two connections for one of the output channels. You can connect up to 1200 Watts of lighting to a single channel. T he t ot a l loa d c a pa c it y of t he AS62D channels 1, 3, and 5 combined is limited to 2400 Watts. The total load capacity of the AS62D channels 2, 4, and 6 combined is also limited to 2400 Watts. CONTROL SIGNAL CONNECTIONS FOR MULTIPLEX OPERATION: The male three pin XLR connector on the unit end panel connects to the control console. The female connector is for connection to additional dimmers. The AS62D dimmer is compatible with the Lightronics and NSI/Sunn three wire multiplexed protocol. If you have older Lightronics dimmers which run in the obsolete Lightronics mode only, contact Lightronics for information on changing the mode. When using multiple dimmers, ALL dimmers MUST be in the SAME mode. OPERATION NORMAL MODE (non-chaser) A green LED in the end panel will indicate that a valid control signal (DMX or multiplex) is applied to the unit. A DIP switch block on the end panel selects the starting channel number of the dimmer. The eight right hand switches control this function. For example, if all switch positions are down - the dimmer will respond to channels 1-6. Moving the switch position on the far right up will set the dimmer to respond to channels 3-8. A complete table of channel assignments is provided in this manual. RELAY MODE Pairs of channels (1/2 and/or 3/4 and/or 5/6) may be switched into the relay mode. In this mode the output of these channels will be either off or full on www.lightronics.com Lightronics Inc. 509 Central Drive, Virginia Beach, VA 23454 Tel: 757 486 3588 Version 1.1 AS62D COMPACT DMX DIMMER OWNER'S MAN UAL Page 3 of 6 06/01/2022 depending on the control console channel setting. The trip point for turn on is approx. 50%. The 3 left hand switches on the DIP switch block control relay mode channel selection. CHASER MODE When operating in the chaser mode the AS62D becomes independent of the control console and other dimmers. The green LED indicator is OFF when in the chaser mode. Chaser mode is turned on and off by one of the DIP switches on the end of the unit. A diagram on the unit cover shows the switch settings for controlling chaser operation. Eight different chaser patterns are available. A "bounce" condition may be imposed on several of the chase patterns by setting one of the DIP switches. The bounce condition causes the chase pattern to run in alternating directions. The chase step time may be controlled for up to 128 seconds per step. Step fade time is proportional to the step time. If a channel is in the relay mode during chaser operation - it will "snap" on and off (zero fade time). The following tables show the details of chaser settings. ADDRESS AND CONTROL SWITCH SETTINGS NORMAL MODE SWITCH FUNCTIONS RELAY 5/6 RELAY 3/4 RELAY 1/2 ADDRESS NORMAL/CHASER (down for normal) CHASER PATTERN SELECTION SWITCHES PATTERN 6 channel sequence 6 channel build 6 channel build/unbuild 6 channel random 3 channel sequence 3 channel build 3 channel build/unbuild 2 channel alternating CHASER TIMING SELECTION SWITCHES STEP TIME 0.5 seconds 1.0 seconds 2 seconds 4 seconds 6 seconds 8 seconds 12 seconds 16 seconds 24 seconds 32 seconds 40 seconds 48 seconds 56 seconds 64 seconds 96 seconds 128 seconds MAINTENANCE AND REPAIR CHASER MODE SWITCH FUNCTIONS RELAY 5/6 RELAY 3/4 RELAY 1/2 BOUNCE CHASER CHASER PATTERN TIMING NORMAL/CHASER (up for chaser) TROUBLESHOOTING · Check that you have power applied to the dimmer. · Check that all light fixtures are functional. · Check the fuses. · Check the multiplex and/or DMX cable. · Check the settings of the dimmer DIP switches. · Check the console setup for correct patching. REPAIR www.lightronics.com Lightronics Inc. The only user serviceable parts are externally accessible fuses. Replace fuses ONLY with 10 509 Central Drive, Virginia Beach, VA 23454 Tel: 757 486 3588 Version 1.1 AS62D COMPACT DMX DIMMER OWNER'S MAN UAL Amp, 250VAC, fast blow fuses. Internal service on the unit by other than Lightronics authorized agents will void the warranty. If service is required, contact the dealer from whom you purchased the dimmer, or Lightronics Service Department, 509 Central Drive, Virginia Beach, VA 23454. Tel: 757 486 3588. WARRANTY INFORMATION AND REGISTRATION CLICK LINK BELOW www.lightronics.com/warranty.html Page 4 of 6 06/01/2022 www.lightronics.com Lightronics Inc. 509 Central Drive, Virginia Beach, VA 23454 Tel: 757 486 3588 Version 1.1 AS62D COMPACT DMX DIMMER OWNER'S MAN UAL Page 5 of 6 06/01/2022 CHANNEL ASSIGNMENT SETTINGS The DIP Switch Setting column shows the positions of the DIP switches on the AS-62 dimmer. The Start Channel column shows the resulting channel assignment for channel 1of the dimmer. The remaining dimmer channels will automatically be assigned the next 5 consecutive control channels. EXAMPLE: If the dimmer's DIP switches are set to then the first channel of the dimmer will respond to console channel 87. The remaining dimmer channels will respond to console channels 88, 89, 90, etc. DIP Switch # and Setting 5 6 7 8 9 10 11 12 Start Channel DIP Switch # and Setting 5 6 7 8 9 10 11 12 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41 43 45 47 49 51 53 55 57 59 61 63 Start Channel DIP Switch # and Setting 5 6 7 8 9 10 11 12 65 67 69 71 73 75 77 79 81 83 85 87 89 91 93 95 97 99 101 103 105 107 109 111 113 115 117 119 121 123 125 127 Start Channel DIP Switch # and Setting 5 6 7 8 9 10 11 12 129 131 133 135 137 139 141 143 145 147 149 151 153 155 157 159 161 163 165 167 169 171 173 175 177 179 181 183 185 187 189 191 Start Channel 193 195 197 199 201 203 205 207 209 211 213 215 217 219 221 223 225 227 229 231 233 235 237 239 241 243 245 247 249 251 253 255 www.lightronics.com Lightronics Inc. 509 Central Drive, Virginia Beach, VA 23454 Tel: 757 486 3588 Version 1.1 AS62D COMPACT DMX DIMMER OWNER'S MAN UAL CHANNEL ASSIGNMENT SETTINGS (continued) Page 6 of 6 06/01/2022 DIP Switch # and Setting 5 6 7 8 9 10 11 12 Start Channel DIP Switch # and Setting 5 6 7 8 9 10 11 12 257 259 261 263 265 267 269 271 273 275 277 279 281 283 285 287 289 291 293 295 297 299 301 303 305 307 309 311 313 315 317 319 Start Channel DIP Switch # and Setting 5 6 7 8 9 10 11 12 321 323 325 327 329 331 333 335 337 339 341 343 345 347 349 351 353 355 357 359 361 363 365 367 369 371 373 375 377 379 381 383 Start Channel DIP Switch # and Setting 5 6 7 8 9 10 11 12 385 387 389 391 393 395 397 399 401 403 405 407 409 411 413 415 417 419 421 423 425 427 429 431 433 435 437 439 441 443 445 447 Start Channel 449 451 453 455 457 459 461 463 465 467 469 471 473 475 477 479 481 483 485 487 489 491 493 495 497 499 501 503 505 507 509 511 www.lightronics.com Lightronics Inc. 509 Central Drive, Virginia Beach, VA 23454 Tel: 757 486 3588