User Manual for ALL Security Equipment models including: Surface Mount Single 1200LSDM Magnetic Lock, Surface Mount Single Lock, Magnetic Lock, 1200LSDM Magnetic Lock, 1200LSDM
Surface Mount Single Magnetic Lock 1200LSDM | All Security Equipment
File Info : application/pdf, 5 Pages, 2.28MB
DocumentDocumentFAS-HUL1200LSDM Magnetic Lock Manual I----------------------------------------------------------------- 1 I I I I Magnetic Lock 1200 lbs. Specification Model Size(mm) Voltag e Current Holdlng Force LockSlgnal DoorSlgnal Time Door Single door magnetic lock DC12V(Default); 260Lx54.7Wx29.6H DC24V(Order) 12V/500mA±10% 24V/250mA±10% Single door magnetic lock DC12V(Default); with signal 260Lx54.7Wx29.6H DC24V(Order) 12V/500mA±10% 24V/250mA±10% Single door magnetic lock with time delay 260Lx54. 7Wx29.6H DC12V(Default); DC24V(Order) 12V/500mA±10% 24V/250mA±10% Single door magnetic lock with bond sensor 260Lx54. 7Wx29.6H DC12V(Default); DC24V(Order) 12V/500mA±10% 24V/250mA±10% Double door magnetic lock 520Lx54. 7Wx29.6H DC12V(Default); DC24V(Order) 12V/S00mA±10%x2 24V/250mA±10%x2 Double door magnetic lock with signal 520Lx54. 7Wx29.6H DC12V(Default); DC24V(Order) 12V/S00mA±10%x2 24V/250mA±10%x2 Double door magnetic lock with time delay 520Lx54. 7Wx29.6H DC12V(Default); DC24V(Order) 12V/S00mA±10%x2 24V/250mA±10%x2 Double door magnetic lock with bond sensor 520Lx54. 7Wx29.6H DC12V(Default); DC24V(Order) 12V/S00mA±10%x2 24V/250mA±10%x2 350kg(800Lbs) 350kg(800Lbs) 350kg(800Lbs) 350kg(800Lbs) 350kgx2(800Lbsx2) 350kgx2(800Lbsx2) 350kgx2(800Lbsx2) 350kgx2(800Lbsx2) NO NO/NC/COM NO/NC/COM NO/NC/COM NO NO/NC/COM NO/NC/COM NO/NC/COM NO NO NO NO/NC/COM NO NO NO NO/NC/COM No Single Door No Single Door 0/3/6/9sec. Single Door No Single Door No Double Door No Double Door 0/3/6/9sec. Double Door No Double Door Diag ramcunit:mm> 0 0 0 0 26500 II 265.00 ao; @ ao; II @ Ill Ill Single Door Magnetic Lock with Signal & Time delay 265.00 lI I: 11 Single door magneticlock 0 ii ii ----------------------------------------------------S-in-g-le-D-oo-r M-a-g-ne-ti-c -Lo-ck-w-it-h -LE-D-&-B-on-d-S-en-s-or------------------- 530 00 4100 0 I;I' I l:FJ Double door magnetic lock 0 0 0 0 0 00 0 0 0 0 00 0 0 0 0 530 00 Ill 1;I' Ill Ill Ill 1 l:FJ Il Ill Ill Double Door Magnetic Lock with Signal & Time delay 0 Ill Ill Ill 0 01:F)O 0 530 00 Ill 1;I' 1Ill @ l:FJ l:FJ Ill Il Ill Ill Ill Ill l:FJ l:FJ Ill Ill Double Door Magnetic Lock with LED & Bond Sensor www.AllSecurityEquipment.com 2 3 Template Door Frame Fold the plate to 90 ° . Door leaf I Template Template Close the door first, then place the upper side of template on door frame, while adjust the left side next to the door leaf. Door leaf Mark screw positions of armature plate and magnetic lock on door leaf and door frame respectively. 4 5 6 7 Door leaf Drill holes based on the marked positions. Make a combination based on the picture. Strike the pin into the armature plate slightly (to avoid movement). Make a combination based on the picture(add washer accordingly). Therubberring must be added. () Place the rubber ring between armature plate and door leaf. 9 ./·····-····,., (,,/ ....._________Jllen Key Use Allen key to remove the mounting plate from lock body. 10 11 Jl Fix the mounting plate on the door frame according to the holes drilled earlier. ,.- /,, ·········...... ( )Allen Key \/_/ ·-...........- Use Allen key to screw the lock body on the mounting plate. 12 13 Hollow Metal Door Wooden Door Close the door to test holding force. The angle between armature plate and magnetic lock can be adjusted by adding or reducing washers. After all the appropriate procedures, the holding force can be maximized. Finally, fix the tamper screw. I I 16mm 8mm Drill a hole Inside: Diameter is 8mm Outside: Diameter is16mm 36mm I I 12.7mm 8mm Drill a hole Inside: Diameter is 8mm Outside: Diameter is 12.7mm Metal Surface Door 11 I 6.8mm for M8-1.25thread lnside:Drill a hole diameter is 8mm folding the plastic straight pin A Notice: Thickness of Door Leaf: 350LBS: 44mm 600LBS: 50mm 800LBS: 48mm 1200LBS: 46mm A. The screw of armature plate should not be fixed too tight. Proper elasticity should be guaranteed for the rubber ring so that the armature plate can adjustitself to the appropriate position. B. Check the jumper's position beforeconnecting. Figure out it represents 12VDC or 24VDC. www.AllSecurityEquipment.com . Bracket Installation Different brackets are available according to different types of doors. For example, narrow door, frameless glass door and inward opening door. L Bracket When the door frame thickness is less than 42mm, L bracket is needed. Single Door Magnetic Lock Bracket LC Bracket LC Bracket one-piece design,wires are mortised.no damage ori wires Double Door Magnetic Lock Bracket Single Door Magnetic Lock Bracket ZL Bracket If install a bracket on inward opening door,ZL bracket is needed Double Door Magnetic Lock Bracket Single Door Magnetic Lock Bracket Double Door Magnetic Lock Bracket ZLC Bracket Hidden-line Design of bracket for single door magnetic lock,one-piece design,durable,easy installation Single Door Magnetic Lock Bracket Double Door Magnetic Lock Bracket GZ Bracket Attention:No GZ bracket for S00kgs series available currently. One-piece design, durable&professional design, easy installation, suitable for 10-1 Smm frameless glass door. Single Door Magnetic Lock Bracket U Bracket If door leaf is glass.need U bracket to be used with lock (suitable for 10-12mm glass door) Double Door Magnetic Lock Bracket Installation of Armature Plate If door leaf is too thick.need to choose I bracket Single Door Magnetic Lock Bracket www.AllSecurityEquipment.com Double Door Magnetic Lock Bracket Circuit Board Diagram A.12VDC Input: Connect the positive(+)lead from a 12VDC power source to V +. Connect the ground(-)lead from a 12VDC power source to V -. Check jumper for 12 VDC operation. B.24VDC Input: Connect the positive(+}lead from a 24VDC power source to V +. Connect the ground(-)lead from a 24VDC power source to V -. Check jumper for 24 VDC operation. Wiring Instruction of S ingle Door Magnetic Lock Door Sensor 12/24V l<ID <IDI DC 12V IO CID OI DC 24V 101010101 JP1 Red -- NC Yellow COM Black -- NO Model with DS will come with one more set of signal for door sensor Lock signal{NO, NC,COM) DC 12/24V and lock status(NO/NC/COM contact) w w -- [g] [g] OS 3S 6S 9S Standard magnetic lock No signal output Model with Twill come with this function Wiring Instruction of Double Door Magnetic Lock Connection: green wire or white plug, except the models without LED indicator and signal output; only when it detects that double doors have been locked, there will be normal signal output. 12/24V l<ID <IDI DC 12V I0 <ID 0I DC 24V 101001 01 1 JP1' ------------------------, NO COM Green: White: Lock signal{NO, NC,COM) · - - -N- -C- - - - - - -0- - - - - -Y-e-ll-o-w- :· V- Black V+ Red DC 12/24V Standard magnetic lock No signal output 0 NO 0 COM 0 NC 0 V0 V+ 0000 JP1 Wire Connection AL ARM SYSTEM : ACCESS CON TROL EB EB EB EB EB EB EB EB EB EB EB H N.C L N .O N .O + N.C COM N .O TAMPER EG G N D DOORBELL 12\/DC OUTPUT I l N · C · : I HIGH POTENTIAL LOW POTENTIAL I I 24 HOUR N.C : --P-RO-T-E-C-T-IO-N-Z-O-NE--I1 RELEASE BUTTON (INSIDE THE HOUSE) Ll'.J,,169N.- O. ---+--. ELECTROMAGNETIC LOCK + POWER SUPPLY 000000 Push + G N D N .C G N D N.O 1 2V OUTPUT 1 N .C www.AllSecurityEquipment.com