Bryant 582K 04-07 Legacy Line Rooftop Gas Heat/Electric Cooling Units
This document provides performance data, certified dimension prints, and certified roof curb details for the Bryant 582K 04-07 Legacy Line Single Package Rooftop Gas Heat/Electric Cooling Units featuring Axion Fan Technology.
Unit Overview
The 582K units are single-packaged electric cooling, gas heating units that are pre-wired and pre-charged with Puron® (R-410A) HFC refrigerant. These units are factory tested in both heating and cooling modes. Sizes 04-06 models utilize single-stage cooling capacity control, while size 07 models feature two-stage cooling capacity control.
Standard Base Unit Features
- Puron® (R-410A) HFC refrigerant
- High SEER and IEER ratings (e.g., 14.0 SEER and 15.2 IEER on 3-phase products, 13.8 SEER2 on single-phase products, 15.0 IEER)
- Meets or exceeds ASHRAE 90.1 energy efficiency levels
- Rated in accordance with AHRI Standards 210/240 for sizes 04-06 and 340/360 for size 07
- Designed in accordance with Underwriters Laboratories Std 1995
- Listed by UL and UL-Canada
- Single-stage cooling capacity control on 04 to 06 models; two-stage on 07 models
- Corrosion-resistant composite sloping design with side or center drain condensate pan; meets ASHRAE Standard 62
- Standard cooling operating range from 40°F to 115°F (4°C to 46°C); field-installable accessory extends minimum down to -20°F (-29°C)
- Field convertible from vertical to horizontal airflow for slab mounting (no special kits required)
- Two-inch disposable return air filters
- Thru-the-bottom power and gas entry capability
- Single point gas and electric connections
- 24-volt control circuit protected with resettable circuit breaker
- Direct Drive - Axion Fan technology indoor fan system with vane axial fan design and electronically commutated motor
- Inherent automatic-reset thermal overload protection
- No fan/motor belts required for operation, adjustments, or initial fan speed setup
- Internally protected from electrical phase reversal and loss
- Slow ramp-up to speed control capabilities to reduce sound and improve comfort
- Slide-out design with two-screw removal
- On 07 size models with two-stage cooling, the indoor fan speed is automatically controlled to meet code compliant 66% low fan speed and 100% at full fan speed
- Totally enclosed condenser motors with permanently lubricated bearings
- Low-pressure and high-pressure switches
Cabinet Features
- Full perimeter base rail with built-in rigging adapters and fork truck slots
- Centralized terminal board for simplified safety circuit troubleshooting and control box arrangement
- New unit control board with intuitive quick fan speed adjustment
- Access panels with easy grip handles
- Innovative, easy starting, no-strip screw feature on unit access panels
- Pre-painted exterior panels and primer-coated interior panels tested to 500 hours salt spray protection
- Fully insulated cabinet
- Tool-less filter access door
Refrigerant System
- Acutrol™ refrigerant metering system on 04 to 06 models; TXV on 07 models
- Liquid line filter drier
- Scroll compressors with internal line-break overload protection (one-stage on 04 to 06 models, two-stage on 07 models)
- Copper tube, aluminum fin coils with optional corrosion-resistant coils
- Top cover removable gage line plugs for reading refrigerant pressure with unit panels in place
Gas Heat Features
- IGC solid-state gas heat exchanger control for on-board diagnostics, anti-cycle protection, LED error code designation, burner control logic, and energy-saving indoor fan motor delay
- Gas efficiencies up to 81%
- Inducted draft combustion
- Redundant gas valve with 2 stages of heating
- Flame roll-out safety protector
- Solid-state electronic direct spark ignition system
- Dedicated 3 to 5 ton "low NOx" models available that meet California Air Quality Management NOx requirement of 40 nanograms/joule. Low NOx models include stainless steel heat exchangers.
Performance Data
The document includes tables for performance data, electrical data, and submittal data, with fields for unit operating weight, cooling capacity, heating capacity, compressor power input, airflow, motor sizes, voltage, phase, circuit amps, and overcurrent protection. It also lists fields for job name, architect, engineer, contractor, and unit designation.
Certified Dimension Prints
Detailed dimensional drawings are provided, illustrating the unit's overall dimensions, component locations, and connection points. These prints include measurements in both inches and millimeters, and specify dimensions for various models (582K*04, 582K*05, 582K*06, 582K*07). Key dimensions include height, width, depth, and specific component clearances.
Certified Roof Curb Details
Information and diagrams for roof curb accessories are presented, including dimensions for 14-inch and 24-inch tall roof curbs. Details cover power and control wiring, gas connection types, and accessory convenience outlet wiring connectors. Notes specify that the roof curb accessory is shipped disassembled, details the construction of insulated panels and the roof curb itself, and provides service clearance recommendations.
Factory-Installed Options
A comprehensive list of factory-installed options is provided, including various economizer configurations (Dry Bulb Sensing, Enthalpy Sensing, with Barometric Relief, Low Leak Air Dampers, ULTRA LOW LEAK Air Dampers) with specific controller compatibility (W7212, W7220, RTU Open) and compliance with California Title 24 and IECC standards. Other options include:
- RTU Open multi-protocol controller communication (BACnet™, Modbus®, LonWorks®, Johnson N2)
- Thru-the-base connectors for gas and electric conduit/piping
- Stainless steel gas heat exchanger
- Perfect Humidity™ adaptive dehumidification system
- Two-position motorized outdoor air damper
- Non-fused disconnect
- Powered 115-volt convenience outlet
- Non-powered 115-volt convenience outlet
- High static evaporator fan motor
- Return air and supply air smoke detectors
- CO2 sensor
- Condenser hail guard
- Special coating protection for evaporator and condenser coils
- Hinged access doors
- Condensate overflow switch
- Time Guard II compressor anti-cycle protection
- Thermostats and sensors
- Economizer Sensors (Single enthalpy, Single dry bulb, Differential dry bulb, Differential enthalpy, CO2 sensors)
Optional Warranties
Information on optional warranties is available, including complete unit parts only (up to 5 years) and complete unit parts and labor (up to 5 years). Further details can be found in the Commercial Start-Up and Optional Extended Warranty Price pages.
Standard Limited Parts Warranty
- 15-year gas heat exchanger parts - Stainless Steel
- 10-year gas heat exchanger parts - Aluminized
- 5-year compressor parts