Instruction Manual for luminii models including: Surface Dynamic Color Ring Surface Mount, Surface Dynamic Color, Ring Surface Mount, Surface Mount, Mount

Plexineon Surface Installation Instructions Dynamic Color

Plexineon Surface Dynamic Color - Luminii


File Info : application/pdf, 5 Pages, 835.12KB

PDF preview unavailable. Download the PDF instead.

Plexineon Surface Installation Instructions Dynamic Color
Installation Instructions - Plexineon Surface Dynamic Color

Models: Plexineon Fixture Surface Mount Dynamic Color and Plexineon Rings Surface Mount Dynamic Color

Please read all instructions prior to installation and keep for future reference!

1. PRODUCT TO BE INSTALLED BY A QUALIFIED ELECTRICIAN. 2. USE ONLY WITH CLASS 2 POWER UNIT 3. 24 VOLTS DC 4. SUITABLE FOR WET LOCATIONS

5. SURFACE MOUNT ONLY

REV0.1 10252022
1 / 5

7777 Merrimac Ave Niles, IL 60714 T 224.333.6033 F 224.757.7557 info@luminii.com www.luminii.com

Plexineon Straight Run Fixture

Plexineon Ring Surface Mount
*LUMINII RESERVES THE RIGHTS TO CHANGE SPECIFICATION & INSTRUCTION WITHOUT NOTICE

Installation Instructions - Plexineon Surface Dynamic Color

Models: Plexineon Fixture Surface Mount Dynamic Color and Plexineon Rings Surface Mount Dynamic Color

Please read all instructions prior to installation and keep for future reference!

1. PRODUCT TO BE INSTALLED BY A QUALIFIED ELECTRICIAN. 2. USE ONLY WITH CLASS 2 POWER UNIT 3. 24 VOLTS DC 4. SUITABLE FOR WET LOCATIONS

5. SURFACE MOUNT ONLY

REV0.1 10252022
2 / 5

7777 Merrimac Ave Niles, IL 60714 T 224.333.6033 F 224.757.7557 info@luminii.com www.luminii.com

1

NOTE: Prior to installation all 24VDC wires must be present within 72" of the installation. Refer to the power supply installation instruction for additional information.

NOTE: More than one person is recommended for this installation.

1.1 Once the location or pattern is determined for Plexineon to be installed, start off by marking the area. Amount of mounting clips may vary dependant upon pattern. Reference diagrams below.

Straight run with mounting clips A.2

A.1

screw

30"
standard mounting clip

plexineon fixture mounting clip

A.1 Line up and screw on the mounting clips to the mounting holes with no greater than 30" apart. Make sure it is straight by using a level. A.2 Fix the plexineon fixture into installed mounting clips. See page 3 for clipping instructions.
Curved run/rings with mounting clips mounting clip

B .1

B.1

Determine the shape of the plexineon layout, then mark thel pattern onto the surface. Place the mounting clips with no greater than 30"

apart. Screw onto surface.

B.2

Fix the plexineon bend/ring fixture into installed mounting clips. See page 3 for clipping instructions.

NOTE: Standard Clips and Decorative Clips have different required spacing.

standard mounting clip 30" space

decorative mounting clip 18" space

*LUMINII RESERVES THE RIGHTS TO CHANGE SPECIFICATION & INSTRUCTION WITHOUT NOTICE

Installation Instructions - Plexineon Surface Dynamic Color

Models: Plexineon Fixture Surface Mount Dynamic Color and Plexineon Rings Surface Mount Dynamic Color

Please read all instructions prior to installation and keep for future reference!

1. PRODUCT TO BE INSTALLED BY A QUALIFIED ELECTRICIAN. 2. USE ONLY WITH CLASS 2 POWER UNIT 3. 24 VOLTS DC 4. SUITABLE FOR WET LOCATIONS

5. SURFACE MOUNT ONLY

REV0.1 10252022
3 / 5

7777 Merrimac Ave Niles, IL 60714 T 224.333.6033 F 224.757.7557 info@luminii.com www.luminii.com

Install Fixtures into Mounting Clips

C .1

mounting clip

C .2

mounting clip installation tool
on grip C.1 Make an U shape with mounting clip installation tool, insert two edges into mounting clip. Place plexineon fixture insde the shape. Then push the fixture into clip. C.2 Remove the tool. Make sure mounting clip is clipped right on the grip.
RGB&RGBW WIRING DIAGRAM PSDMX-96-24 DMX LED Driver

*LUMINII RESERVES THE RIGHTS TO CHANGE SPECIFICATION & INSTRUCTION WITHOUT NOTICE

Installation Instructions - Plexineon Surface Dynamic Color

Models: Plexineon Fixture Surface Mount Dynamic Color and Plexineon Rings Surface Mount Dynamic Color

Please read all instructions prior to installation and keep for future reference!

1. PRODUCT TO BE INSTALLED BY A QUALIFIED ELECTRICIAN. 2. USE ONLY WITH CLASS 2 POWER UNIT 3. 24 VOLTS DC 4. SUITABLE FOR WET LOCATIONS

5. SURFACE MOUNT ONLY

REV0.1 10252022
4 / 5

7777 Merrimac Ave Niles, IL 60714 T 224.333.6033 F 224.757.7557 info@luminii.com www.luminii.com

WIRING DIAGRAM
SR-DMX-SPI Smart Pixel LineLED Decoder
NOTE: Please make sure that power is turned off before wiring.
Also, ensure that the correct power supply (voltage and wattage) is used to power the LED strips connected to the decoder. Follow illustrated wiring diagram. Use screwdriver to open and close connection slots.

NOTE: When connecting two or moreBLEeDfostrreip lwighirtsinorgli,ghetnfixstuurrees, palowwaysemr aikseosufrfettohepsiognwaledrirection arrows

are pointing to same direction

supply

The signal direction arrow should appeAalrsoon, leanbseul oref etahcahtstehcetiocnoorfrLeEcDt fpixotuwre.er supply (voltage

and wattage) is used to power the LED strips

Signal direction arrow

connected to the decodSiegrn.aFl odilrleocwtioinlluasrrtorawted wiring diagram. Use screwdriver to open and close

connection slots.

NOTE: Must power from the opposite direction of the signal direction arrow

CONTROLLER WIRES
1000 ft max, decoder to Controller
In
Out

32 ft max, decoder to strip

PIXEL PLEXINEON

(-) POWER SUPPLY
(L)

output
(+) 24VDC

AC input
(N)

*LUMINII RESERVES THE RIGHTS TO CHANGE SPECIFICATION & INSTRUCTION WITHOUT NOTICE

Installation Instructions - Plexineon Surface Dynamic Color

Models: Plexineon Fixture Surface Mount Dynamic Color and Plexineon Rings Surface Mount Dynamic Color

Please read all instructions prior to installation and keep for future reference!

1. PRODUCT TO BE INSTALLED BY A QUALIFIED ELECTRICIAN. 2. USE ONLY WITH CLASS 2 POWER UNIT 3. 24 VOLTS DC 4. SUITABLE FOR WET LOCATIONS

5. SURFACE MOUNT ONLY

REV0.1 10252022
5 / 5

7777 Merrimac Ave Niles, IL 60714 T 224.333.6033 F 224.757.7557 info@luminii.com www.luminii.com

OPERATING GUIDE

SR-DMX-SPI Smart Pixel LineLED Decoder
There are three buttons on the decoder.

Parameter Setting

Increase Value

After operation, if no action was taken within 30s, the button lock, and backlight of the screen will turn off.

1. Long press M button for 5s to unlock the buttons, and the backlight will turn on. 2. Long press M button for 5s to switch between test mode and decode mode after unlocked. During test mode, the first line of LCD will show: TEST MODE. Use test mode to verify RGBW Pixel functionality. Duirng decoder mode, the first line of LCD shows: DECODER MODE. Use decoder mode when connecting to a Controller and for final installation and customization.

The second line of the LCD Display shows the current setting and value. Note: 1 Pixel = 1 Cut Increment

MODE TABLE

SETTING

LCD DISPLAY

VALUE RANGE

DESCRIPTION

Built-in Programs

TEST MODE MODE NO.:

1-26

See Program Table below

Program Speed

TEST MODE RUN SPEED:

0-7

0: fast, 7: slow

DMX Address

DECODER MODE DMX ADDRESS:

1-512

Address of the starting point/Pixel of a program

DMX Signal RGB

DECODER MODE DMX RGB SEQ:

RGB, BGR, etc. N/A

Pixel Quantity IC TYPE
Color Pixel Merging /
Pixel Size

DECODER MODE PIXEL QTY:
DECODER MODE IC TYPE:
DECODER MODE COLOR:
DECODER MODE PIXEL MERGE:

1-170(RGB), 1-128(RGBW)
2903, 8903, 2904, 8904
MONO, DUAL, RGB, RGBW

Number of Pixels to follow a program
2903: N/A, 2904: for RGBW, 8903: N/A, 8904: N/A
MONO: N/A, DUAL: N/A, RGB: N/A, RGBW: for RGBW

1-100

Number of Pixels to merge together

RGB Sequence

DECODER MODE LED RGB SEQ:

RGBW, BGRW, etc.

Sequence of RGBW, 24 possible combinations

Integral Control

DECODER MODE ALL CONTROL:

YES, NO

Yes: Merge all Pixels No: Maintain individual Pixels or Merged Pixels

Reverse Control

DECODER MODE REV-CONTROL:

YES, NO

Reverse program order

Overall Brightness

DECODER MODE BRIGHTNESS:

1-100

1: dimmest setting 100: brightest setting

PROGRAM TABLE PROGRAM NO. 1 2 3 4 5 6 7 8 9

PROGRAM DESCRIPTION Solid color: Red
Solid color: Green Solid color: Blue Solid color: Yellow Solid color: Purple Solid color: Cyan Solid color: White
RGB change Full color change

PROGRAM NO. 10 11 12 13 14 15 16 17 18

PROGRAM DESCRIPTION RGB fading
Full color fading Red chase with trail Green chase with trail Blue chase with trail White chase with trail RGB chase with trail Rainbow chase with trail RGB chasing and fading

Decrease Value
NOTE: When connected to a controller, DMX512 Signal Decoder will stay in "Decoder Mode".

NOTE: The actual maximum control pixels of the controller are 1360 (2903) ,1024 (2904). Please set the pixel and pixel combination value according to the actual situation, and DO NOT exceed the maximum.

NOTE: For Program Table Change: no fading/dimming between color changes Fade: fade/dim between color changes Chase: change pixel by pixel Chase with Trail: change pixel by pixel with fading between

PROGRAM NO. 19

PROGRAM DESCRIPTION Red chasing green, chasing blue

20

Orange chasing purple, chasing cyan

21

Rainbow chase (7 colors)

22

Random twinkle: white over red

23

Random twinkle: white over green

24

Random twinkle: white over blue

25

White fading

26

Off

*LUMINII RESERVES THE RIGHTS TO CHANGE SPECIFICATION & INSTRUCTION WITHOUT NOTICE



References

Adobe PDF Library 16.0.7 Adobe InDesign 17.4 (Windows)