Mirage MIR7570-8BN 8 Bar Heated Towel Rail - Brushed Nickel: Specifications & Installation Guide

Mirage MIR7570-8BN 8 Bar Heated Towel Rail

Finish: Brushed Nickel

Specifications

Item NumberMIR7570-8
Width750 MM
Height700 MM
Depth120 MM
Power115 W
Voltage220-240 V/50Hz
Wiring MethodHard-wired or Plug-in
Wiring PositionBottom left or right
IP GradeIP 55
Material304 Stainless Steel
Warranty15 years replacement warranty (including finish)
ApprovalSAA Approved

Features

  • Designed for bathroom use
  • Surface temperature: 45-50°C
  • 1.0m Power cord included

Available Finishes

  • Chrome
  • Brushed Chrome
  • Matt Black
  • Gunmetal
  • Brushed Bronze
  • Brushed Nickel
  • Champagne

Cleaning & Care

  • Regularly clean with mild soapy water.
  • Do not use harsh detergents, bleach, or abrasive cleaners.
  • Using unsuitable cleaning products may damage the surface.
  • Refer to the installation guide for correct installation procedures.
  • Check for any product defects prior to installation.

Installation Guide

Installation Options

There are two options for installing this Heated Towel Rail:

  1. Concealed Wiring (Hard-Wired): Provisions must be made for a switched supply wire to feed through the wall surface to the preferred mounting point for the towel rail. This type of installation MUST be performed by a licensed electrician.
  2. Exposed Wiring (Plug-In): A switched plug socket is required within 1 metre of the preferred mounting point for the towel rail.

Concealed Wiring Installation (Hard-Wired)

This appliance MUST be installed by a licensed electrician.

  1. Remove the towel rail from the box. Check all parts are supplied against the Product Components List. For Hard Wired Installation, you will not require the A2 spigot or B2 bracket.
  2. Unscrew the safety cap on the towel rail plug according to the left or right position of the wiring outlet you require.
  3. Take out the B3 Bracket for hard-wired installation. Thread the power cord through the B3 Bracket and connect the cord into the plug in the required position.
  4. Attach the B3 Bracket onto the rail and fasten with the pointed grub screw.
  5. Install the other B3 Bracket onto the other power connection point that is not being used, fasten with the pointed grub screw.
  6. Install the 2 x B1 Brackets onto the rail using the 2 x Long Screws.
  7. Position the towel rail against the wall. Using a pencil, draw around the end of each bracket to mark the bracket fixing positions on the wall. Remove the towel rail from the wall.
  8. Using a suitable drill bit, drill holes to the required screw depth into the centre of the drawn circles on the wall at each fixing point.
  9. Place the 4 plastic anchors into the drilled holes.
  10. Using a self-tapping screw, screw the A3 Spigot onto the wall at the wire connection point. Insert the electrical wire through the hole in the A3 Spigot for hard wiring.
  11. Fix the 3 x A1 Spigots onto the 3 other fixing points on the wall using the self-tapping screws.
  12. Place the towel rail onto the wall. Once the 4 brackets are in place covering the 4 spigots, use the Allen Key to fasten the brackets onto the spigots by inserting the 4 Flat Grub Screws into the hole in each bracket, and tighten the rail securely to the wall.

Exposed Wiring Installation (Plug-In)

  1. Remove the towel rail from the box. Check all parts are supplied against the Product Components List. For Plug-In Installation, you will not require the A3 Spigot or one of the B3 Brackets.
  2. Unscrew the safety cap on the towel rail plug according to the left or right position of the wiring outlet you require.
  3. Take out the B2 Bracket for exposed installation. Thread the power cord through the B2 Bracket and connect the cord into the plug in the required position.
  4. Attach the B2 Bracket onto the rail and fasten with the pointed grub screw. The power cord fits through the hole at the base of the Bracket so that the leg sits flush against the wall. Face the hole in the bracket in the direction you require the cord to be exposed from.
  5. Install the B3 Bracket onto the other power connection point that is not being used, fasten with the pointed grub screw.
  6. Install the 2 x B1 Brackets onto the rail using the 2 x Long Screws.
  7. Position the towel rail against the wall. Using a pencil, draw around the end of each bracket to mark the bracket fixing positions on the wall. Remove the towel rail from the wall.
  8. Using a suitable drill bit, drill holes to the required screw depth into the centre of the drawn circles on the wall at each fixing point.
  9. Place the 4 plastic anchors into the drilled holes.
  10. Using the self-tapping screws, screw the A2 Spigot onto the wall at the wire connection point.
  11. Fix the 3 x A1 Spigots onto the 3 other fixing points on the wall using the self-tapping screws.
  12. Place the towel rail onto the wall. Once the 4 brackets are in place covering the 4 spigots, and the power cord is neatly sitting through the hole in the B2 Bracket, use the Allen Key provided to fasten the brackets onto the spigots by inserting the 4 Flat Grub Screws into the hole in each bracket, and tighten the rail securely to the wall.

Product Accessories List

  • A1 Spigot x3
  • A2 Spigot x1
  • A3 Spigot x1
  • B1 Bracket x2
  • B2 Bracket x1
  • B3 Bracket x2
  • Self-tapping Screw x4
  • Plastic Anchor x4
  • Long Screw x2
  • Flat Grub Screw x5
  • Pointed Grub Screw x3
  • Allen Key x1
  • Power Cord x1

Safety Warnings

  • To reduce the risk of injury, do not drape the cord over the counter top or table top where it can be pulled down by children or tripped over unintentionally.
  • A short power-supply cord (or detachable power-supply cord) is provided to reduce risks resulting from becoming entangled in or tripping over a longer cord.
  • Longer detachable power-supply cords or extension cords are available and may be used if care is exercised in their using.
  • If a long detachable power-supply cord or extension cord is used, its marked electrical rating should be at least as great as the electrical rating of the appliance.
  • If the appliance is of the grounded type, the extension cord should be a grounding type 3-wire cord.
  • The longer cord should be arranged so that it will not drape over the counter top or table top where it can be pulled on by children or tripped over.
Models: MIR7570 Mirage 8 Bar Wide Heated Towel Rail, MIR7570, Mirage 8 Bar Wide Heated Towel Rail, Wide Heated Towel Rail, Heated Towel Rail, Towel Rail

PDF preview unavailable. Download the PDF instead.

MIR7570-8BN-Install-Guide Adobe Acrobat Pro (64-bit) 24.2.20759

Related Documents

Preview Mirage MIR100 Vertical Heated Towel Rail - Specifications & Installation Guide
Detailed specifications, features, cleaning instructions, and installation guide for the Mirage MIR100 Vertical Heated Towel Rail. Includes safety information and available finishes.
Preview Mirage B-34 VHF Amplifier: User Manual and Specifications
Explore the features, specifications, installation, and troubleshooting for the Mirage B-34 VHF linear power amplifier, designed for 144-148 MHz operation with handheld transceivers.
Preview Mirage Nanosat Omnipolar Speaker System Owner's Manual
This manual provides comprehensive instructions for the Mirage Nanosat Omnipolar Speaker System, covering safety precautions, installation, placement, connections, and warranty information.
Preview Mirage MX-36HP3 AM 10 Meter Amateur Mobile Transceiver User's Manual
User's manual for the Mirage MX-36HP3 AM 10 Meter Amateur Mobile Transceiver, covering specifications, installation, and operation.
Preview Mirage A-1015-G 6 Meter RF Amplifier User Manual
Comprehensive user manual for the Mirage A-1015-G 6 Meter RF Power Amplifier, detailing specifications, installation, operation, and troubleshooting.
Preview Mirage B-320-G 2-Meter VHF Power Amplifier Instruction Manual
Instruction manual for the Mirage B-320-G, a 200-watt VHF power amplifier for the 2-meter band (144-148 MHz). Covers features, specifications, installation, operation, troubleshooting, and warranty information.
Preview Mirage D-1010-N 430-450 MHz Amplifier User Manual
Instruction manual for the Mirage D-1010-N 430-450 MHz Power Amplifier, covering specifications, installation, front and rear panel functions, precautions, internal adjustments, and troubleshooting.
Preview Mirage B-24-G VHF Linear Amplifier User Manual
User manual for the Mirage B-24-G VHF band high power linear amplifier, detailing features, specifications, installation, precautions, and warranty.