WARNINGS
· Explosive gases. Prevent flames and sparks. Provide adequate ventilation during charging · Before charging, read the instructions · For indoor use. Do not expose to rain · For charging lead acid and LiFePO4 batteries ONLY (of the size & voltage specified in the
specifications table) · Always charge the battery on the correct voltage setting. Never set the charger to a higher
voltage than the battery specifications state · Disconnect the 240V mains supply before making or breaking the connections to the battery · Connect the positive battery terminals before making any ground connections. The ground
connection to the chassis should be made away from the battery and any fuel line. Only connect mains after the battery is connected. · The battery charger must be plugged into an earthed socket outlet · Connection to supply mains is to be in accordance with national wiring rules · Do not attempt to charge non-rechargeable batteries · Never charge a frozen battery · If AC cord is damaged, do not attempt to use. Replace with a compatible earthed IEC cable immediately. · Corrosive substances may escape from the battery during charging and damage delicate surfaces. Store and charge in a suitable area · This charger is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning the use of the appliance by a person responsible for their safety · Children being supervised not to play with the appliance · If the recreational vehicle is to be put into storage without power, please turn off the BATTERY MASTER SWITCH. If the recreational vehicle is to be stored for 3 months or longer, it's advisable to disconnect all fuses from the battery. A full charge should be run every 3 months.
2

CONTENTS

1 Product Instructions .................................................................................................................. 4

1.1 Overview

4

1.2 Features

5

1.3 Block Diagram

5

1.4 Water Tank Probe

6

2 Key Features and Functions...................................................................................................... 7

2.1 Multiple Inputs

7

2.2 Battery Charging of House/Service Battery

7

2.3 Vehicle Battery Charger

7

2.4 Power Supply Mode

8

2.5 MPPT Solar Charger Controller

8

2.6 Voltage Sensitive Relay (commonly known as a VSR)

8

2.7 Categorised Outputs

8

2.8 Battery Low Voltage Protection (BLVP or commonly known as an LVD)

9

2.9 Battery Switch

9

2.10 Precise Battery Measurement

9

2.11 Night Mode

9

3 Structure and Installation ....................................................................................................... 10

3.1 PM435C Power Management System

10

3.2 Water Tank Probe

12

4 Wiring....................................................................................................................................... 13

4.1 System Components

13

4.2 System Schematic

13

4.3 Preparation

14

4.4 Connection

14

5 Wiring....................................................................................................................................... 15

5.1 PM435C Master Unit

15

6 Operation ................................................................................................................................. 16

6.1 Manual Switch

16

6.2 Remote Switch

16

6.3 Dip Switch

16

6.4 Maintenance

17

7 Specifications........................................................................................................................... 18

8 Add On Accessories ................................................................................................................. 20

8.1 Projecta Accessory Range

20

3

1 Product instructions 1.1 Overview
PM435C unit is designed for use in caravans or motor homes. It has the following functions integrated into the unit: battery charger, distribution blocks, MPPT solar charger controller, VSR, battery low voltage protection, water pump controller. PM435C is designed for easy installation and has a user-friendly interface.
SYSTEM COMPONENTS
1 Master Power unit 2 Display Screen/Monitor 3 Up to 4 water tank probes, based on monitor selection (not included) 4 Accessories cables
Display Screen Select from P/No: PM4SWLED, PMD-BT3C, PMD-BT4C or PMD-BT7C
Figure 1 System Components
4

1.2 Features
PM435C has the following features
· Smart battery charger 12V 30 Amp (35 Amp total supply for loads + charge) ­ Multistage adaptive charging algorithm ­ Active Power Factor Correction (PFC) charging ­ Temperature compensation charging
· Float charge for starter battery · Solar charge controller (MPPT), 30A · 15 built in fused outputs · Built-in voltage sensing relay
­ for DC charge of up to 12V 60 Amps continuous with 80 Amp for up to 30 minutes · Battery Low Voltage Protection · Built-in battery switch to isolate the battery when in storage · Built-in shunt for precise battery measurement · Support for 4 water tank sensors · Built-in RF for wireless switches · Water tank probe connectors and input screw terminals · RS485 & CAN compatible

1.3 Block diagram

CATEGORY Class A5 Class A2

QTY 5 3

DESCRIPTION Relay controlled output with fuse. Protected by main master switch relay Dimmable, protected by master switch relay

Class C2 4

Class C3 2

Class D

1

Fused outputs, protected by master switch relay Always On Load (LVD protected) Constant supply loads (no discharge protection)

POSSIBLE USES
Water pump, HWS, TV etc.
General lighting, such as ceiling light, dining light, bedroom light
Ventilation fan etc.
Fridge, security alarm etc.
Breakaway systems, Sway Controllers, Radio memory

Class D
5

1.4 Water Tank Probe
PM435C can monitor a maximum of 4 water tank probes. Note: Always check the probe required for the water Tank before purchase. There are 2 Probe styles.

PMWS200:
· Side installation · Suitable for water tank · Depth > 200mm

PMWS400:
· Side installation · Suitable for water tank · Depth 300-400mm `

Figure 4 PMWS200

Figure 5 PMWS400

6

2 Key Feature and Functions

2.1 Multiple Inputs
PM435C can support multiple charging sources at any one time. These sources include AC mains, Solar and starter battery (Vehicle). Charging priorities are listed within the table to the right.

Table 3 Source priority AC MAINS SOLAR DC IN CHARGING PRIORITY

X X
COMBINED

X
X
AC MAINS

X X
COMBINED

2.2 Battery Charger Of Stationery/Service Battery
The charger automatically starts when the appropriate power is connected, either from grid, generator or solar.
With multiple charging stages (Soft-start, bulk, absorption, float & recycle), the PM435C is designed to fully charge the service battery quickly. PM435C features Microprocessor-controlled charging algorithms. The Float and Recycle charging programs ensure that the battery condition does not change despite being connected for a long period.
When the Charger is at Float Stage, if a new input source is added (AC Mains or Solar), the charger will return to the Bulk stage.

VOLTAGE 11.5V
lcc

5 hours 1 hr

5mins

Figure 6 Charging Algorithm

CURRENT

½ lcc

STAGE

SOFT START

BULK

1

2

ABSORPTION
3

FLOAT
4

RECYCLE
5

Icc is the rated current.

1

SOFT START Increases battery life by gently starting to charge the battery 5% of bulk

2

BULK Reduces charging time by delivering maximum charge to set voltage life by

gently starting to charge the battery 25% of bulk

3

ABSORPTION Ensures a full charge to the battery without overcharging

4

FLOAT Float charge maintains the battery at 100% charge

5 RECYCLE

Battery Temperature Sensor
The optional battery temperature sensor (P/N: PMBS-3m) can be used with the PM435C to measure the temperature of the battery, allowing the PM435C to to adjust, in real time, the charge to the battery, at a compensation rate of -4mv±10%/ºc/cell. In installations where the BTS is not present, the PM435C will use 25ºC as a default setting. The voltage sensor can automatically adjust its output to compensate the voltage drop caused by a cable. This assures the right voltage is being delivered for optimal charging.
Adjustable Charging capacity
Users can adjust the charging current by specifying the battery capacity. The charging current is set at threshold rate of 10% the of the battery capacity (I = 0.1C) by default
Lithium Battery Charging
The PM435C can be configured to charge Lithium batteries. With Lithium batteries, the max charging current will automatically be set at 30% of battery capacity (Imax=0.3C)
2.3 Vehicle Battery Charger
Along with a powerful charger for the service battery, PM435C offers a float charge of up to 3A to keep the starter battery topped up, whether connected to AC mains or PV (Solar). When the starter battery is less than 12.4V, the PM435C starts charging after a 30 minute delay, and stops charging when the voltage reaches 12.8V
7

2.4 Power Supply Mode
If no battery is attached to PM435C Unit, it will automatically work as a power supply with a 12.8VDC output.
2.5 MPPT Solar Charger Controller
PM435C has a built-in MPPT charger for the service battery with: · Max input voltage up to 50VDC · Max charging current 30A · Max supply current 30A * PM435C may cause LiFePO4 BMS over-voltage protecting to trigger when charging through Solar. In this case, disconnect the solar charge fuse and discharge the battery.
2.6 Voltage charging relay (commonly known as VSR)
PM435C has a built-in voltage charging relay (also known as a VSR), which offers a convenient source to charge the service battery via the alternator whilst the engine is running or via an external DC-DC charger.
LEAD ACID BATTERY ­ When the starter battery reaches 13.4VDC with threshold time delay, the VSR will charge the service battery from the alternator. The VSR will continue the charging until the starter battery voltage drops under 12.8VDC.
LiFePO4 LITHIUM BATTERY ­ When the starter battery reaches 14.0VDC with threshold time delay, the VSR will charge the service battery from the alternator. The VSR will continue charging until the starter battery charging current less than 2A charge to the service battery with threshold time delay.
NOTE: The PM435C starter battery input does not provide 5-stage charging.
It takes whatever power is available from the alternator to charge.
It simply takes whatever power and charging is available from the alternator
NOTE: PM435C If your vehicle is fitted with a smart charging system (Variable Voltage or Temperature Compensating), the VSR charge system may not function correctly and the Projecta PMDCS range of DC-DC chargers are recommended.
Please consult your local dealer or installer for further information.

2.7 Categorised Outputs

The 15 outputs are categorised into groups and controls as per below:

CATEGORY Class A5 Class A2

QTY 5 3

DESCRIPTION Relay controlled output with fuse. Protected by main master switch relay Dimmable, protected by master switch relay

Class C2 4

Class C3 2

Class D

1

Fused outputs, protected by master switch relay Always On Load (LVD protected) Constant supply loads (no discharge protection)

POSSIBLE USES
Water pump, HWS, TV etc.
General lighting, such as ceiling light, dining light, bedroom light
Ventilation fan etc.
Fridge, security alarm etc.
Breakaway systems, Sway Controllers, Radio memory

8

2.8 Battery Low voltage protection (BLVP or commonly known as an LVD)
PM435C master power unit has a built-in low voltage protection relay. It will disconnect the load once the battery voltage drops below the threshold voltage. The default setting is 10.5VDC. This can be manually turned On/Off via the LOAD button on the LCD display. NOTE: Class C3 will remain active as long as the battery switch is left on and Class D loads remain active all the time.
2.9 Battery switch
The PM435C unit offers a convenient way to switch off the output of the service battery on-board. It protects the service battery from being drained by electronics on board, completely isolating the battery. PM435C unit also supports a remote manual battery switch. Before using the remote switch, ensure the manual battery switch at the unit is set as "ON". The switch is only effective when the system has no other energy resource for the load except the battery.
2.10 Precise Battery Measurement
PM435C unit has a battery measurement system controlled by microprocessor. It measures battery voltage, charge/discharge current, remaining battery capacity (in amp hours) and time remaining. Compared to conventional indicating meters, even small currents can be measured and read accurately with this device. This feature highlights faults, alarms and installation errors. NOTE: If you have loads connected directly on the battery instead of PM435C Power Management System, the measurement will not be accurate. NOTE: P/No. PMSHUNT will be required for heavy loads designed to be connected direct to battery to ensure SOC% accuracy.
2.11 Night Mode
In Night Mode, the backlight of the monitor will turn off and the cooling fans will operate at a decreased speed. Charge current will be reduced to half rated selection when night mode is active.
9

3 STRUCTURE AND INSTALLATION 3.1 PM435C Power Management System

10

11

12 13 14 15 16

17

9

1

8

765432

NO

NAME

DESCRIPTION

1

AC Input

AC input

2

Solar+

Solar input Positive

3

SBAT+

Starter BATT input Positive

4

BAT+

Service BATT input Positive

5

Always ON+

40A Always ON output Positive

6

Solar-

Solar input Negative

7

BAT-

Service BATT input Negative

8

Load-

Load negative

9

Load+

Load positive

10 Battery Sensor / Dry contact Battery sensor and 6 dry set contact

11 Switch Panel / COMM IO COMM for LED panel and 485 COM for Power module and sensors

12

LCD Monitor

COM for LCD monitor

13

Water1

1 Water Tank

14

Water2

2 Water Tank

15

Water3

3 Water Tank

16

Water4

4 Water Tank

17

Remote Switch

Power Management Remote

Switch

TYPE IEC Socket Screw terminal
WAGO connector 20 pin socket 16 pin socket
12 pin socket 8 pin socket 8 pin socket 8 pin socket 8 pin socket WAGO connector

10

76.3mm

252.25mm 224mm

296mm
316mm 338.9mm
Installation:
PM435C adopts fan-forced air cooling for heat dissipation. In order to ensure good heat dissipation, it is necessary to ensure that there is enough installation space. The installation space needs to keep a minimum distance of 50mm on the left and right of the unit to keep the vents clear. It is also recommended that the installation space has adequate ventilation to ensure effective airflow. Recommended vent size: 144 x 54mm
11

3.2 Water Tank Probe
PMWS400 WATER TANK PROBE

Installation

PMWS200 WATER TANK PROBE

Installation

12

4 Wiring

4.1 System Components

CODE 1
2
3 4 5

NAME

MODEL/LENGTH

Battery Management System

PM435C

Display Screen

PM4SWLED/PMD-BT3C/PMD-BT4C/ PMD-BT7C

Water Tank Level Sensor

PMWS200/PMWS400

AC Power Cable

0.3M

Display Screen Cable

5M/10M

6 Battery Sensor Cable (Optional)

3M/10M

QTY

P/NO. ON DRAWING

1

1

1

2

4

3

1

PMACR

1 Refer To Display Manual and diagram on page 22-25

1

PMBS-3M/PMBS-10M

4.2 System Schematic

CATEGORY Class A5 Class A2

QTY 5 3

DESCRIPTION Relay controlled output with fuse. Protected by main master switch relay Dimmable, protected by master switch relay

Class C2 4

Class C3 2

Class D

1

Fused outputs, protected by master switch relay Always On Load (LVD protected) Constant supply loads (no discharge protection)

POSSIBLE USES
Water pump, HWS, TV etc.
General lighting, such as ceiling light, dining light, bedroom light
Ventilation fan etc.
Fridge, security alarm etc.
Breakaway systems, Sway Controllers, Radio memory

13

4.3 Preparation
PM435C system is designed with cease of installation in mind. To complete the easy installation, a screwdriver and DC cables are required. Follow Table 5 recommendation for minimum wiring sizes.

CURRENT 0­5A 5­10A 10­15A 15­20A 20­25A 25­30A

MINIMUM CABLE SIZE 1.0mm2 or 18 AWG 2.0mm2 or 14 AWG 3.0mm2 or 13 AWG 4.0mm2 or 11 AWG 5.0mm2 or 10 AWG 6.0mm2 or 9 AWG

When running cables, if they pass through panels or wall, ensure the cables are protected from damage by sharp edges. In such cases, it is recommended to use cable glands.

4.4 Connection
PM435C is designed with both spring and screw terminals. Please refer to following illustration below. Each type of terminal is designed to fit a different range of cables.

TYPE
Type 1 Type 2 Type 3

MINIMAL CABLE SIZE
ERTB10-10.16 Wago2604-111 Wago2606-1103

SUITABLE CABLE GAUGE
0.5mm2 ­ 10mm2 0.2mm2 ­ 4mm2 0.25mm2 ­ 6mm2

TYPE 1 (SCREW TERMINALS)

TYPE 2 & 3 (SPRING TERMINALS)

14

5 Wiring 5.1 PM435C Master unit

No.

LED

COLOUR

1

Mains

2

AUX

GREEN

3

Solar

4

CHG

5

FAULT

RED

STATUS ON OFF
Quick flashing ON
Slow flashing (once every second)
Quick flashing (twice every second) OFF ON
Slow Flash (once every second)
Quick flashing (twice every second) OFF ON
Slow Flash (once every second) Quick flashing (twice every second)
OFF ON 1 flash 2 flash 3 flash 4 flash 5 flash 8 flash 9 flash

DESCRIPTION AC input OK AC disconnected AC input abnormal Starter battery charging the battery The input of the Aux is normal but battery is charged by AC Mains Starter Battery input error Starter Battery disconnected Solar charging the battery The input voltage of the PV is normal but Battery is charged by AC Mains Solar input abnormal Solar disconnected Battery charging - Float Stage Battery charging - BULK, ABS Stage or VSR Battery discharging Battery disconnected Short circuit Service battery undervoltage Service battery overvoltage Over temperature (heat sink) Bulk charge time-out VSR abnormal Over temperature (Unit) Over temperature (PCB or Load circuit)

15

6 Operation 6.1 Manual Switch
There is an ON/OFF switch on the side of the machine, which is used to control the whole machine to switch on/off when it is powered by battery alone, and to control the whole machine to enter into sleep mode when it is powered by mains power. This switch must be be "ON" in order for the Remote Switch to operate.
6.2 Remote Switch (Optional)

The remote switch terminals are located next to the positive 14 terminal. This requires the use of an external switch and functions the same way as the manual On/Off Battery Switch on the side of the charger. The Battery switch must be "ON" in order to use the Remote Switch line. When not used both terminals must be bridged together.

6.3 Dip Switch

ON 1 2 3 4 5

There is 5 pin dip switch on the unit which is used for adjusting charging current and battery type. At this time, switch 5 is not used and should be in the "OFF" position
Note: These do not not to be adjusted if a digital screen is used

Pin 1-2 Definition

1

2

ON

ON

ON

OFF

OFF

ON

OFF

OFF

Lead Acid

AC Charge Solar Charge

10A

20A

15A

30A

20A

30A

30A

30A

Lithium AC/Solar Charge
30A 30A 30A 30A

Pin 3-4 Definition

3

4

Type

Absorption

Float

ON

ON

WET

14.7

13.7

ON

OFF

LFP

14.2

13.5

OFF

ON

GEL

14.1

13.5

OFF

OFF

AGM

14.4

13.5

16

6.4 Maintenance
BATTERY MONITOR MAINTENANCE
PM435C systems feature built-in battery measurement software. To ensure accurate readings, maintain the system with the following instructions: 1: Fully charge the battery from AC input instead of solar every 2 weeks. 2: Fully charge the battery from mains at least once every 3 months, even in storage, unless required to earlier. ·Charge the battery with AC grid until the "CHG" LED on PM435C unit or "Float" shows on the monitor.
DAILY MAINTENANCE
· Confirm the Power switch is turned ON when you want to charge the battery with AC grid · Check the nominal battery is 12VDC · Ensure the Space (50mm each side) beside the PM435C unit for the appropriate ventilation · When replacing and existing battery, fully charge via AC grid to Float Stage to ensure SOC% is accurately calibrated.
Only the energy consumption of the loads connected on the PM435C is measured and calculated in the data on the Monitor. Unless a shunt is fitted. Projecta p/n PMSHUNT For storage it is recommended to switch off the the Manual Battery Switch on the unit or the Remote Switch (if installed) to cut off power to the system from the service battery. NOTE:There may be some loads connected to the battery or constant output line(class D) that can continue to draw power.
17

7 SPECIFICATION

MODEL

ELECTRICAL SPECIFICATIONS

Grid

Nominal input voltage (V)

Battery
PV
Charging Relay
Charger Mode

Power factor Input current at full load Starter Battery Starter battery voltage range Service battery Service battery voltage range Charger type Open circuit voltage Max supply current Max charging current Relay specification
Connect voltage Connect delay time Disconnect voltage Disconnect delay time High voltage limit Charge algorithms Start voltage Bulk current Absorption voltage

Float voltage

Battery type

Maximum battery capacity

Maximum battery quantity

Power Supply Mode

Nominal output voltage Rated output current

Efficiency

Battery Disconnect Disconnect voltage

Delay off time Reconnect voltage

PM435C

240V ±10%VAC 50/60Hz 0.95 2.5A 12VDC 12.8-16VDC 12VDC 10.5-16VDC MPPT 50VDC 30A 30A 12VDC@60a continuous DC charge, peak current 12VDC@80a (Peak for maximum of 30 minutes) Lead Acid: 13.4VDC, LiFePO4: 14VDC 10 sec Lead Acid: 12.8V, LiFePO4: < 2A 60 sec 16VDC 5 Stages >2A 30A (Max) 14.4/14.1/14.2/14.7VDC. Ensures a full charge to the battery without overcharging 13.5/13.5/13.5/13.7VDC. Float charge maintains the battery at 100% charge AGM/GEL/LFP(LiFePO4)/WET 1200Ah Dependent on battery capacity 14.4VDC 35A (Continuous)

88% Lead Acid LFP (LiFePO4) 60 sec Lead Acid LFP (LiFePO4)

10.5VDC (Default) 11.2VDC (Default)
11.5VDC (Default) 12.2VDC (Default)

18

MODEL

ELECTRICAL SPECIFICATIONS

Current draw Only Battery and Load

on battery

switch ON

PM435C 700mA

Fused outputs Protection

Only Battery and Load switch OFF Only Battery, Voltage < LVD Power Switch OFF Numbers Rated current Light outputs Short circuit on outputs Reverse polarity Overload protection Battery charger over temperature Ambient over temperature Battery over voltage limits

PHYSICAL SPECIFICATIONS

Dimension

339mm*252mm*76mm

Weight

3.3KG

Enclosure

Metal & Plastic

Battery Connector

M4 Screw (16mm2)

Load Connector Wago2604-111 (4mm²)

Cooling Protection category Approvals Electrical EMC

Wago2604-1103 (6mm²) Forced cooling IP20
AS/NZS 60335.2.29 CISPR14

300mA
180mA < 1mA 11 15A L7, L8, L9 5A x 3 Fuse blown Diode reverse isolation Derate the output until overload is removed Shut down PM435C
Alarm Battery charger disconnected, Load disconnected

19

8 ADD-ON ACCESSORIES

8.1 Projecta Accessory Range
The PM235C, PM335C and PM435C support a range of additional Projecta accessories as listed below: For details on how to connect these, refer to the connection diagram (Figure 25, page 22-25).

SC520/SC540
5 STAGE MPPT SOLAR CHARGER CONTROLLER WITH 100V INPUT
Get the most out of your solar array using these Maximum Power Point Tracking (MPPT) Solar controllers increasing the charging output by up to 30% (compared to PWM Solar controllers).

PART No. Battery Volatge Maximum Solar Voltage Standby Current Charge Type Input Output Control Type Batteries Supported Temperature Compensation Communication Storage Temperature Humidity IP Rating Weight Cooling

20 AMP

60 AMP

SC520

SC540

12/24/48V

100V

1mA at 12V, 3mA at 24V, 5mA at 48V

5 Stage

100V

20A

40A

MPPT

GEL, AGM, Wet, Lithium

-18mV/12V

RS485, Bluetooth

-40 - 70°C

5 - 95%

IP31

1.4Kg

Convection

PMDCS30/PMDCS60
DC-DC 12V CHARGER
Smart DC to DC chargers specifically designed for IntelliRV and Intelli-Grid.

PART No. Charge Type Alternator Input Voltage Output Batteries Supported Alternator Type Storage Temperature Operating Temperature Temperature Compensation IP Rating Dimensions Weight Cooling Smart Alternator
Conventional

30 AMP

60 AMP

PMDCS30

PMDCS60

5 Stage

12- 16V

12V, <30A

12V, <60A

GEL, AGM, Wet, Lithium

Smart & Conventional

-40 - 70°C

-40 - 70°C

-3mV/°C/Cell

IP20

181 x 148 x 52mm

1.0kg

Convection

Turn on 12.2V

Turn off 11.6V

Turn on 13.2V

Turn off 12.8V

PMDCS30-20 DC-DC 12V CHARGER
Smart DC to DC chargers specifically designed for IntelliRV and Intelli-Grid where a 3 way fridge or compressor fridge are used.
Note: If using load as a `CONSTANT' connection (set via display or APP), the output of DCDC charger MUST be connected directly to LB-HD or PMSHUNT.
20

PART No. Charge Type Alternator Input Voltage Output Batteries Supported Alternator Type Storage Temperature Operating Temperature Temperature Compensation IP Rating Dimensions Weight Cooling Smart Alternator
Conventional

PMDCS30-20 5 Stage 12- 16V
12V, <30A GEL, AGM, Wet, Lithium Smart & Conventional
-40 - 70°C -40 - 70°C -3mV/°C/Cell
IP20 181 x 148 x 52mm
1.0kg Convection Turn on 12.2V Turn off 11.6V Turn on 13.2V Turn off 12.8V

PMTPMS
TYRE PRESSURE MONITORING SYSTEM MODULE
The Tyre Pressure Monitoring System (TPMS) monitors the RV's tyre pressure before and during the journey.

PART No.
PART No. Input Working Current Working Temperature Humidity Recieving Frequency Wired Communication Weight PART No. Working Voltage Battery Type Transmitted Current Transmitted Power Transmitted Frequency Pressure Range Accuracy Working Temperature Weight

PMTPMS x 4 (one for each type)
Reciever - PMTPMS-R 6-24V 30mA
-40°C - 85°C <9S%
433.910Mhz RS48S 1S0g
Sender - 4 x PMTPMS-S 2.2 - 3.6V CR1632 <5mA <5dbm 433.910Mhz 14 - 130PSI ±1.45 PSI
-30°C - 70°C 13.8g

PMLVL
LEVELLING SENSOR
Level the RV with the levelling sensor which can be monitored via the phone app.
Calibration

PART No. Working Voltage Working Current Working Temperature IP Rating Accuracy

To calibrate the level sensor, the RV needs to be level in both forward and back and side to side. Once level, go to the Setting Page, select Level Sensor and press Calibrate. This will zero the sensor.

LB200-HD 12V HIGH DISCHARGE 200AH LITHIUM BATTERY
LB200-HD boast impressive capabilities and are ideal for 4WDs and caravans with high power demands
LB400-HD 12V HIGH DISCHARGE 400AH LITHIUM BATTERY
The LB400-HD boasts an astonishing 400Ah capacity and a market leading 300A discharge capability making it ideal to partner with high current drawing appliances such as 3000W inverters.

PART No. Nominal Voltage Nominal Capacity Nomincal Energy Charge Voltage Discharge Cut-Off Voltage Standard Charge Current Maximum Charge Current Maximum Discharge Current Peak Discharge Current Operating Temperature Maximum Number of Batteries In Parallel Number Of Discharge Cycles Weight IP Rating
PART No. Nominal Voltage Nominal Capacity Nomincal Energy Charge Voltage Discharge Cut-Off Voltage Standard Charge Current Maximum Charge Current Maximum Discharge Current Peak Discharge Current Operating Temperature Maximum Number of Batteries In Parallell Number Of Discharge Cycles Weight IP Rating

PMLVL 9 - 16V 30mA -40°C - 85°C IP20 ± 2°
LB200-HD 12.8V 200ah 2560Wh 14.2V 11.2V
100 Amps 200 Amps 200 Amps 300 Amps (10mins) -20°C - 60°C
4
3000 22Kg IP20
LB400-HD 12.8V 400ah 2560Wh 14.2V 11.2V
100 Amps 200 Amps 200 Amps 300 Amps (10mins) -20°C - 60°C
4
3000 22Kg IP20
21

22

23

WARRANTY STATEMENT
Applicable only to product sold in Australia
Brown & Watson International Pty Ltd of 1500 Ferntree Gully Road, Knoxfield, Vic.,telephone (03) 9730 6000, fax (03) 9730 6050, warrants that all products described in its current catalogue (save and except for all bulbs and lenses whether made of glass or some other substance) will under normal use and service be free of failures in material and workmanship for a period of one (1) year (unless this period has been extended as indicated elsewhere) from the date of the original purchase by the consumer as marked on the invoice. This warranty does not cover ordinary wear and tear, abuse, alteration of products or damage caused by the consumer.
To make a warranty claim the consumer must deliver the product at their cost to the original place of purchase or to any other place which may be nominated by either BWI or the retailer from where the product was bought in order that a warranty assessment may be performed. The consumer must also deliver the original invoice evidencing the date and place of purchase together with an explanation in writing as to the nature of the claim.
In the event that the claim is determined to be for a minor failure of the product then BWI reserves the right to repair or replace it at its discretion. In the event that a major failure isdetermined the consumer will be entitled to a replacement or a refund as well as compensation for any other reasonably foreseeable loss or damage. This warranty is in addition to any other rights or remedies that the consumer may have under State or Federal legislation.
IMPORTANT NOTE
Our goods come with guarantees that cannot be excluded under the Australian Consumer Law. You are entitled to a replacement or refund for a major failure and compensation for any other reasonably foreseeable loss or damage. You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure.

Distributed by
AUSTRALIA Brown & Watson International Pty Ltd Knoxfield, Victoria 3180 Telephone (03) 9730 6000 Facsimile (03) 9730 6050 National Toll Free 1800 113 443
NEW ZEALAND Narva New Zealand Ltd 22­24 Olive Road PO Box 12556 Penrose Auckland, New Zealand Telephone (09) 525 4575 Facsimile (09) 579 1192
24

IS599 Issue 1 10/05/24


Adobe PDF Library 17.0 Adobe InDesign 18.5 (Macintosh)