John Lewis Isabel Pendant User Manual

Model: IL3693

Introduction

Thank you for purchasing this Isabel pendant. Please read the instructions carefully before use to ensure safe and satisfactory operation of this product.

Warnings

  • For your safety, this product must be installed in accordance with local Building Regulations. If in any doubt, or where required by the law, consult a competent person who is registered with an electrical self-certification scheme. Further information is available online or phone your Local Authority.
  • To prevent electric shock, switch off the mains supply before installing or maintaining this product. Ensure other persons cannot restore the electricity supply without your knowledge.
  • Always use the correct bulb type with the correct wattage as indicated in the specification table. Never exceed the Max. power rating. When changing a bulb always switch off at the mains first and allow the bulb to cool down before handling. Dispose of used bulbs carefully. The bulb and surrounding parts can become extremely hot during use.
  • This product is Class II [double-insulated symbol] and should be fitted to a lighting Supply protected by a 5 amp fuse or equivalent circuit breaker.
  • For indoor use only.

Product Visual Description

The Isabel Pendant is a chandelier-style light fixture suspended by a decorative chain. It features a central stem leading to a lampshade, within which three lamp holders are housed. The illustration provided is a line drawing detailing the product's structure and components.

Assembly Instructions

Never install your appliance on a wet, freshly painted or plastered surface. Ensure the house electricity supply is switched off at the fuse box. If removing an existing fitting, note down all wiring connections. Check the fixings will not touch any existing wiring before drilling and attaching the light to the ceiling. Ensure you thread the ceiling wires through the black insulating tube fixed to the appliance.

  1. Ensure the house electricity supply is off at the fuse board.
  2. If removing an existing fitting, first note down all wiring connections.
  3. Remove mounting bracket from fitting by removing the retaining screws and washers; retain these for later.
  4. Using the mounting bracket as a template, mark and then drill the fixing holes in the ceiling (ensure holes are drilled into a secure joist). Take care not to damage wiring.
  5. Attach mounting bracket to the mounting surface using suitable fixings. Do not attach the fitting to the mounting bracket at this stage. Make sure no wires are trapped in the process.
  6. This fitting is height adjustable at the point of installation only. Adjustment must not be made once it has been attached to the ceiling. If adjustment is required later, the fitting must be isolated from the mains and removed from the ceiling first. Using two pairs of pliers, carefully open the chain links and remove the required number of links. Close the links. Note: Use cloth between the jaws of the pliers to protect the decorative finish. Pull any excess cable through the ceiling cup. IMPORTANT: Ensure the chain is supporting the weight of the fitting and not the electrical cable.
  7. Screw the top hanging ring stem into the main stem rising from the lamp holder section and tighten until fully secured.
  8. Attach the bottom chain link to the top ring of the chandelier. This is performed by unscrewing the side of the link until it opens, placing it over the top ring, and retightening to close the link again.
  9. Lever open the terminal block box cover with a screwdriver, then feed the supply cable through the rubber sleeving. The weight of the fitting must be supported whilst making the electrical connections as follows:
    • Connect supply live (normally brown or red) to fitting live (marked “L”) on the terminal block.
    • Connect supply neutral (normally blue or black) to fitting neutral (marked “N”) on the terminal block.
    NO EARTH must be connected to any part of this fitting. If there are any earth wires present in the ceiling, these must be terminated into a separate terminal block (not supplied) to ensure continuity of the earth circuit is maintained. NOTE: Ensure electrical connections are tight and no loose strands of wire are left out of the connector block. Ensure terminals and rubber sleeve are correctly seated, then close the connector block housing.
  10. Excess cable must be carefully located inside the ceiling cup or within the ceiling void. Carefully offer the fitting over the mounting bracket, then secure in place with the screws and washers removed earlier.
  11. Fit the bulb, type and wattage as displayed on the fitting. The stated wattage must not be exceeded.

Once installation is complete, the house electricity may be restored at the fuse box.

Care Instructions

Wipe clean with a clean dry cloth, when the product is switched off and has cooled down.

Recommended Bulb

3 x 28W E14 (SES) eco halogen candle bulb OR 3 x 8W energy saving spiral bulb.

Specifications

Max. Power: 40W

Voltage: 230V, 50Hz

Compliance and Manufacturer Information

The product bears the CE mark [CE mark], [double-insulated symbol], and [safety mark].

Please retain these instructions for future reference.

John Lewis Partnership
171 Victoria Street
London SW1E 5NN
johnlewis.com

Made in China

Models: Isabel Pendant, IL3693

File Info : application/pdf, 4 Pages, 215.63KB

PDF preview unavailable. Download the PDF instead.

237094394mnl1

References

Kamil Fitrzyk Adobe PDF Library 21.1.177

Related Documents

Preview Obelisk LED Bar Pendant User Manual | John Lewis
User manual for the John Lewis Obelisk LED Bar Pendant, providing detailed instructions for installation, assembly, and care. Includes safety warnings and product specifications.
Preview John Lewis Callum House Ceiling Pendant - User Manual and Installation Guide
Detailed user manual and installation instructions for the John Lewis Callum House Ceiling Pendant (Model IL4074). Includes specifications, safety warnings, care instructions, troubleshooting, and step-by-step assembly.
Preview John Lewis Lars Ceiling Pendant User Manual - Installation & Troubleshooting Guide
Detailed user manual for the John Lewis Lars Ceiling Pendant (IL4082). Find specifications, safety warnings, parts list, step-by-step assembly instructions, and troubleshooting tips for your lighting fixture.
Preview Magnolia 8LT Pendant User Guide | John Lewis | 701 422220
User guide for the John Lewis Magnolia 8LT Pendant light fitting (Product Code: 701 422220). Includes detailed installation instructions, parts list, product information, technical specifications, and troubleshooting advice for safe and satisfactory operation.
Preview John Lewis ZENA LED Bar Pendant User Manual and Installation Guide
Comprehensive user manual and installation guide for the John Lewis ZENA LED Bar Pendant light. Includes specifications, safety warnings, assembly instructions, troubleshooting, and care instructions.
Preview John Lewis Vintage Tiered Glass Chandelier User Manual and Assembly Guide
Comprehensive user manual for the John Lewis Vintage Tiered Glass Chandelier, covering specifications, safety warnings, care instructions, troubleshooting, and detailed assembly steps with textual descriptions of diagrams.
Preview John Lewis Opal Pebble Wall Light IP44 User Manual and Installation Guide
Detailed user manual and installation guide for the John Lewis Opal Pebble Wall Light (Model IL4236). Provides essential information on specifications, safety warnings, assembly instructions, wiring, bulb replacement, care, and troubleshooting for this IP44 rated lighting fixture.
Preview John Lewis BAMBOO WALL LT User Manual and Installation Guide
Comprehensive user manual and installation guide for the John Lewis BAMBOO WALL LT light fixture, including specifications, warnings, care instructions, parts list, and step-by-step assembly instructions for safe installation.