ZOYI ZOTEK ZT-703S Dual-Channel Oscilloscope Multimeter

User Manual

Introduction

The ZOYI ZOTEK ZT-703S is a versatile dual-channel oscilloscope multimeter featuring a 3.5-inch IPS display with 25,000 counts and a built-in signal generator. It is designed for professional use in electronics testing and measurement.

Key Features

  • 3.5-inch IPS display
  • 25,000 counts
  • Dual-channel oscilloscope
  • Built-in signal generator
  • USB Type-C charging and data transfer
  • Wide voltage input range (AC 25V, DC 36V)
  • ABS + TPE housing

Display Indicators

  • ▶️ RUN: Indicates normal operation.
  • ⏳ WAIT: Indicates a waiting state or process.
  • T'D: Trigger delay or time domain indicator.
  • ⏹️ STOP: Indicates the device has stopped measurement or is in a halted state.
  • ⏸️ HOLD: Indicates a held or frozen display.

Button Functions and Navigation

The device features several buttons for control and navigation:

  • 1️⃣ CH 1 / 2️⃣ CH 2: Selects the channel for oscilloscope or measurement functions.
  • ? VOL/TIME (F1): Adjusts voltage sensitivity or time base settings.
  • ➡️ MOVE (F2): Navigates through menus or adjusts cursor positions.
  • ☰ MENU (F3): Accesses the main menu or specific function menus.
  • ? SAVE/LOAD (F4): Manages saving and loading of settings or waveforms.
  • ⚙️ AUTO/RANGE: Automatically sets the optimal range for measurements or oscilloscope display.
  • ? REL (Relative): Sets a reference point for measurements.
  • Cursor Buttons: Used for precise positioning on waveforms or measurements.
  • Numeric Keys (0-9): Inputting values or selecting options.
  • +/- Keys: Adjusting values or polarity.

Operating Modes

The ZT-703S supports multiple operating modes:

Oscilloscope Modes

  • ⚙️ AUTO: Automatically configures the oscilloscope settings for optimal display.
  • MANUAL: Allows manual adjustment of settings like range, time base, and trigger.
  • NORMAL: Standard oscilloscope operation.
  • SINGLE: Captures a single trigger event.
  • ⏸️ HOLD: Freezes the current waveform display.

Measurement Modes

  • ⚡ DC Voltage: Measures direct current voltage.
  • ⚡ AC Voltage: Measures alternating current voltage.
  • ⚡ DC Current: Measures direct current.
  • ⚡ AC Current: Measures alternating current.
  • Ω Resistance: Measures electrical resistance.
  • Capacitance: Measures electrical capacitance.
  • Hertz Frequency: Measures signal frequency.
  • Diode Test: Tests diode forward voltage drop.
  • Continuity Test: Checks for electrical continuity with an audible beep.
  • Signal Generator: Outputs various waveforms (Sine, Square, Sawtooth, etc.).

Oscilloscope Functions

The oscilloscope functionality includes:

  • Dual Channels: Simultaneous display and analysis of two signals.
  • Bandwidth: 50 MHz analog bandwidth.
  • Sampling Rate: Up to 280 MSa/s real-time sampling.
  • Record Length: Up to 128K bytes per channel.
  • Triggering: Auto, Normal, Single modes with rising/falling edge triggers.
  • Display Modes: YT (Time Domain), XY (Lissajous figures), Roll mode.
  • Persistence: Minimum, 500ms, 1S, 10S, Infinite.
  • Measurements: Auto measurement of Period, Frequency, Peak-to-Peak, Max, Min, RMS, Duty Cycle, Pulse Count.
  • Cursors: Time and Voltage cursors for precise measurements.

Signal Generator

The integrated signal generator can produce the following waveforms:

  • Sine wave
  • Square wave
  • Sawtooth wave
  • Half wave
  • Full wave

Frequency and amplitude can be adjusted.

Technical Specifications

General Specifications
ParameterSpecification
Display3.5-inch IPS LCD
Counts25,000
Channels2
Power SupplyBuilt-in rechargeable battery (18650)
Charging PortUSB Type-C (5V DC)
Housing MaterialABS + TPE
Dimensions177mm x 89mm x 40mm
WeightApprox. 380g
Multimeter Specifications
FunctionRangeResolutionAccuracy
DC Voltage250mV - 750V0.0001V - 0.1V±(0.05%+3) - ±(2.0%+5)
AC Voltage250mV - 750V0.0001V - 0.1V±(0.5%+3) - ±(5.0%+20)
DC Current25mA - 10A0.001mA - 0.1A±(0.5%+3) - ±(5.0%+5)
AC Current25mA - 10A0.001mA - 0.1A±(0.8%+3) - ±(5.0%+5)
Resistance250Ω - 250MΩ0.001Ω - 0.1MΩ±(0.5%+3) - ±(5.0%+5)
Capacitance2.5nF - 25mF0.001nF - 0.1mF±(0.2%+3) - ±(5.0%+20)
Frequency10Hz - 40MHz0.001Hz - 0.01MHz±(1%+3) - ±(5.0%+20)
Diode TestN/AN/ATest Voltage ~3V
Continuity TestN/AN/AAudible beep if R < 50Ω
Oscilloscope Specifications
CharacteristicDescription
Bandwidth50 MHz
Channels2
Sampling Rate200 MSa/s (Normal), 280 MSa/s (High-speed)
Input CouplingDC, AC
Input Impedance1MΩ, @16pF
AttenuationX1, X10
Max Input VoltageX1: <150V, X10: <300V (DC+AC peak)
Time Base Range10ns/div - 20s/div
Vertical Sensitivity20mV/div - 10V/div
Record LengthUp to 128K bytes
Trigger ModesAuto, Normal, Single
Trigger EdgesRising edge, Falling edge
Display ModesYT, XY, Roll
Persistence ModesMinimum, 500ms, 1S, 10S, Infinite
Signal Generator Specifications
WaveformFrequency RangeAmplitude Range
Sine, Square, Sawtooth, Half wave, Full wave(Adjustable)(Adjustable)

Battery and Charging

The ZT-703S is powered by a built-in 18650 rechargeable battery. It can be charged via the USB Type-C port using a 5V DC power adapter. The battery typically lasts for a significant duration, and charging is indicated on the display. Recommended charging is at 50-70% capacity for optimal battery health.

Safety Precautions

  • Always ensure the correct measurement range is selected before connecting the device to a circuit.
  • Do not exceed the maximum input voltage or current ratings specified for each function.
  • Avoid using the device in environments with excessive dust, moisture, or extreme temperatures.
  • Ensure proper grounding when measuring high voltages.
  • Refer to the manual for detailed safety instructions.

PDF preview unavailable. Download the PDF instead.

ZT 703S-ZOYI-INSTRUKTSIYA PDF Printer / www.bullzip.com / FG / Freeware Edition (max 10 users)

Related Documents

Preview ZOYI ZOTEK ZT-703S Oscilloscope and Signal Generator User Manual
Comprehensive user manual for the ZOYI ZOTEK ZT-703S portable oscilloscope and signal generator, detailing specifications, operation, and features.