Trane 2twb3048a1000aa Manual
Split System Air Conditioners and Heat Pumps
Product Data Split System Cooling 4TTR4018L1000A 4TTR4024L1000B 4TTR4025L1000B 4TTR4030L1000A 4TTR4031L1000A 4TTR4036L1000A 4TTR4037L1000A 4TTR4042L1000A 4TTR4043L1000A 4TTR4048L1000A 4TTR4060L1000B Note: "Graphics in this document are for representation only. Actual model may differ in appearance." April 2020 22-1904-1M-EN Product Specifications Model No. (a) 4TTR4018L1000A 4TTR4024L1000B/ 4TTR4025L1000B 4TTR4030L1000A/ 4TTR4031L1000A 4TTR4036L1000A/ 4TTR4037L1000A POWER CONNS. -- V/PH/HZ (b) 208/230/1/60 208/230/1/60 208/230/1/60 208/230/1/60 MIN. BRCH. CIR. AMPACITY 12 14 17 18 BR. CIR. PROT. RTG. -- MAX. (AMPS) 20 20 25 30 COMPRESSOR CLIMATUFF®SCROLL CLIMATUFF®SCROLL CLIMATUFF®SCROLL CLIMATAUFF®SCROLL RL AMPS -- LR AMPS 9 -- 63 10.1 -- 52 12.8-- 68 14.1-- 72 Outdoor Fan FL AMPS 0.60 0.90 0.77/.64 0.77/.64 Fan HP 1/15 1/8 1/8 1/8 Fan Dia (inches) 18.2 18.2 23.0 23.0 Coil SPINE FINTM SPINE FINTM SPINE FINTM SPINE FINTM Refrigerant R-410A 4 LBS., 2 OZ 4 LBS., 11 OZ / 4 LBS., 2 OZ 4 LBS., 11 OZ 5 LBS., 8 OZ / 5 LBS., 3 OZ LINE SIZE -- IN. O.D. GAS (c) 3/4 3/4 3/4 3/4 LINE SIZE -- IN. O.D. LIQ. (c) 3/8 3/8 3/8 3/8 Charge Spec. Subcooling 10°F 10°F 10°F 10°F / ( 8°F on 037) Dimensions H x W X D Crated (IN.) 30.1 x 26.7 x 30 30.1 x 26.7 x 30 34 x 30.1 x 33 38 x 30.1 x 33 Weight -- Shipping (lbs.) 153 153 183 183 Weight -- Net (lbs.) 133 133 156 156 Optional Accessories: Anti-short Cycle Timer TAYASCT501A TAYASCT501A TAYASCT501A TAYASCT501A Evaporator Defrost Control AY28X079 AY28X079 AY28X079 AY28X079 Rubber Isolator Kit BAYISLT101 BAYISLT101 BAYISLT101 BAYISLT101 Extreme Condition Mount Kit Start Kit BAYECMT023 BAYKSKT263 BAYECMT023 -- BAYECMT023 BAYKSKT263 BAYECMT023 BAYKSKT263 Crankcase Heater Kit Seacoast Kit BAYCCHT302 BAYSEAC001 BAYCCHT302 BAYSEAC001 BAYCCHT302 BAYSEAC001 BAYCCHT302 BAYSEAC001 Low Ambient Kit Service Valve Panel Cover BAYLOAM103 TAYSVPANL0022AA BAYLOAM103 BAYLOAM103 BAYLOAM103 TAYSVPANL0022AA TAYSVPANL0032AA TAYSVPANL3343AA Refrigerant Lineset (d) (a) Certified in accordance with the Unitary Air-conditioner equipment certification program which is based on AHRI standard 210/240. (b) Calculated in accordance with N.E.C. Only use HACR circuit breakers or fuses. (c) Standard line lengths -- 60', Standard lift -- 60' Suction and Liquid line. For Greater lengths and lifts refer to refrigerant piping software Pub#3233120* (* denotes latest revision). (d) 25, 30, 35 and 50 foot linesets available. For a complete listing of lineset options available from equipment or supply stores, refer to the Trane Residential and Light Commercial Product Handbook. 2 22-1904-1M-EN Product Specifications Model No. (a) POWER CONNS. -- V/PH/HZ (b) 4TTR4042L1000A/ 4TTR4043L1000A 280/230/1/60 4TTR4048L1000A 280/230/1/60 4TTR4060L1000B 280/230/1/60 MIN. BRCH. CIR. AMPACITY 22 24 27 BR. CIR. PROT. RTG. -- MAX. (AMPS) 35 40 45 COMPRESSOR CLIMATUFF®- SCROLL CLIMATUFF®- SCROLL CLIMATUFF®- SCROLL RL AMPS -- LR AMPS Outdoor Fan FL AMPS 16.7 -- 109 1.05 18.5 -- 124 1.05 20.8 -- 127.1 1.05 Fan HP 1/5 1/5 1/5 Fan Dia (inches) 27.5 27.5 27.5 Coil SPINE FINTM SPINE FINTM SPINE FINTM Refrigerant R-410A 6 LBS., 2 OZ / 5 LBS., 5 OZ 5 LBS., 3 OZ 7 LBS., 10 OZ LINE SIZE -- IN. O.D. GAS (c) 7/8 7/8 7/8 LINE SIZE -- IN. O.D. LIQ. (c) 3/8 3/8 3/8 Charge Spec. Subcooling 12°F 10°F 10°F Dimensions H x W X D Crated (IN.) 34.4 x 35.1 x 38.7 34.4 x 35.1 x 38.7 42.4 x 35.1 x 38.7 Weight -- Shipping (lbs.) 216 212 246 Weight -- Net (lbs.) 184 189 211 Optional Accessories: Anti-short Cycle Timer TAYASCT501A TAYASCT501A TAYASCT501A Evaporator Defrost Control AY28X079 AY28X079 AY28X079 Rubber Isolator Kit BAYISLT101 BAYISLT101 BAYISLT101 Extreme Condition Mount Kit Start Kit Crankcase Heater Kit Seacoast Kit Low Ambient Kit BAYECMT004 BAYKSKT263 BAYCCHT301 BAYSEAC001 BAYLOAM103 BAYECMT004 BAYKSKT263 BAYCCHT301 BAYSEAC001 BAYLOAM103 BAYECMT004 BAYKSKT263 BAYCCHT301 BAYSEAC001 BAYLOAM103 Service Valve Panel Cover Refrigerant Lineset (d) TAYSVPANL0044AA (a) Certified in accordance with the Unitary Air-conditioner equipment certification program which is based on AHRI standard 210/240. (b) Calculated in accordance with N.E.C. Only use HACR circuit breakers or fuses. (c) Standard line lengths -- 60', Standard lift -- 60' Suction and Liquid line. For Greater lengths and lifts refer to refrigerant piping software Pub#3233120* (* denotes latest revision). (d) 25, 30, 35 and 50 foot linesets available. For a complete listing of lineset options available from equipment or supply stores, refer to the Trane Residential and Light Commercial Product Handbook. 22-1904-1M-EN 3 Product Specifications Sound Power Level MODEL 4TTR4018L1 4TTR4024L1 4TTR4025L1 4TTR4030L1 4TTR4031L1 4TTR4036L1 4TTR4037L1 4TTR4042L1 4TTR4043L1 4TTR4048L1 A-Weighted Sound Power Level [dB(A)] 71 71 71 71 71 71 Sound Power Level Full Octave Sound Power(dB) 63 125 250 Hz* Hz Hz 74 71 65 74 71 65 73 73 72 73 73 72 81 72 69 81 72 69 500 1000 2000 Hz Hz Hz 68 67 63 68 67 63 69 68 60 69 68 60 69 66 60 69 66 60 4000 Hz 56 56 52 52 57 57 4TTR4060L1 71 81 72 69 69 66 60 57 Note: Rated in accordance with AHRI Standard 2702008 *For Reference Only 8000 Hz 50 50 45 45 54 54 54 4 22-1904-1M-EN Accessory Description and Usage Anti-Short Cycle Timer -- Solid state timing device that prevents compressor recycling until five (5) minutes have elapsed after satisfying call or power interruptions. Use in area with questionable power delivery, commercial applications, long lineset, etc. Evaporation Defrost Control -- SPST Temperature actuated switch that cycles the condenser off as indoor coil reaches freeze-up conditions. Used for low ambient cooling to 30°F with TXV. Rubber Isolators -- Five (5) large rubber donuts to isolate condensing unit from transmitting energy into mounting frame or pad. Use on any application where sound transmission needs to be minimized. Hard Start Kit -- Start capacitor and relay to assist compressor motor startup. Use in areas with marginal power supply, on long linesets, low ambient conditions, etc. Extreme Condition Mount Kit -- Bracket kits to securely mount condensing unit to a frame or pad without removing any panels. Use in areas with high winds, or on commercial roof tops, etc. AHRI Standard Capacity Rating Conditions AHRI Standard 210/240 Rating Conditions 1. Cooling 80°F DB, 67°F WB air entering indoor coil, 95°F DB air entering outdoor coil. 2. High Temperature Heating 47°F DB, 43°F WB air entering outdoor coil, 70°F DB air entering indoor coil. 3. Low Temperature Heating 17°F DB air entering indoor coil. 4. Rated indoor airflow for heating is the same as for cooling. AHRI Standard 270 Rating Conditions -- (Noise rating numbers are determiend with the unit in cooling operations.) Standard Noise Rating number is at 95°F outdoor air. Model Nomenclature Outdoor Units 4TWV 0 0 3 6 A 1 0 0 0A A Refrigerant Type 2 = R-22 4 = R-410A TRANE Product Type W = Split Heat Pump T = Split Cooling Product Family V = Variable Speed Z = Leadership Two Stage X = Leadership R = Replacement/Retail M or B = Basic A = Light Commercial L = Side Discharge Family SEER 3 = 13 6 = 16 4 = 14 8 = 18 5 = 15 9 = 19 0 = 20 Split System Connections 1-6 Tons 0 = Brazed Nominal Capacity in 000s of BTUs Major Design Modifications Power Supply 1 = 200-230/1/60 or 208-230/1/60 3 = 200-230/3/60 4 = 460/3/60 Secondary Function Minor Design Modifications Unit Parts Identifier 22-1904-1M-EN 5 Schematic Diagrams Figure 1. 1.54.0 Ton Models 6 22-1904-1M-EN Figure 2. 5.0 Ton Models Schematic Diagrams 22-1904-1M-EN 7 Schematic Diagrams Figure 3. 5.0 Ton Models 8 22-1904-1M-EN Outline Drawing Model Base A B C D 4TTR4018L 730 724 651 2 (283/4) (281/2) (255/8) 3/4 4TTR4024L 4TTR4025L 730 724 651 2 (283/4) (281/2) (255/8) 3/4 4TTR4030L 4TTR4031L 730 829 756 3 (283/4) (325/8) (293/4) 3/4 4TTR4036L 4TTR4037L 832 829 756 3 (323/4) (325/8) (293/4) 3/4 4TTR4042L 4TTR4043L 741 946 870 4 (291/8) (371/4) (341/4) 7/8 4TTR4048L 741 946 870 4 (291/8) (371/4) (341/4) 7/8 4TTR4060L 4 943 946 870 (371/8) (371/4) (341/4) 7/8 E F G H J 3/8 127 (5) 57 (21/4) 194 (75/8) 38 (11/2) 3/8 127 (5) 57 (21/4) 194 (75/8) 38 (11/2) 3/8 127 (5) 76 197 60 (3) (73/4) (23/8) 3/8 127 (5) 76 197 60 (3) (73/4) (23/8) 3/8 143 (55/8) 83 (314) 206 (81/8) 70 (23/4) 3/8 143 (55/8) 83 (314) 206 (81/8) 70 (23/4) 3/8 152 (6) 98 (37/8) 219 (85/8) 86 (33/8) K 457 (18) 457 (18) 508 (20) 508 (20) 508 (20) 508 (20) 508 (20) 22-1904-1M-EN 9 Mechanical Specification Options General The outdoor condensing units are factory charged with the system charge required for the outdoor condensing unit, ten (10) feet of tested connecting line, and the smallest rated indoor evaporative coil match. This unit is designed to operate at outdoor ambient temperatures as high as 115°F. Cooling capacities are matched with a wide selection of air handlers and furnace coils that are AHRI certified. The unit is certified to UL 1995. Exterior is designed for outdoor application. Casing Unit casing is constructed of heavy gauge, galvanized steel and painted with a weather-resistant powder paint finish. The corner panels are prepainted. All panels are subjected to our 1,000 hour salt spray test. Refrigerant Controls Refrigeration system controls include condenser fan, compressor contactor and low and high pressure switches. A factory supplied, field installed liquid line drier is standard. Compressor The compressor features internal over temperature and pressure protection. Other features include: Centrifugal oil pump and low vibration and noise. Condenser Coil The outdoor coil provides low airflow resistance and efficient heat transfer. The coil is protected on all four sides by louvered panels. Low Ambient Cooling As manufactured, this system has a cooling capacity to 55°F. The addition of an evaporator defrost control permits operation to 40°F. The addition of an evaporator defrost control with TXV permits low ambient cooling to 30°F. The addition of the BAYLOAM107A low ambient kit permits ambient cooling to 20°F. Thermostats--Cooling only and heat/cooling (manual and automatic change over). Sub-base to match thermostat and locking thermostat cover. 10 22-1904-1M-EN Notes 22-1904-1M-EN 11 Trane - by Trane Technologies (NYSE: TT), a global innovator - creates comfortable, energy efficient indoor environments for commercial and residential applications. For more information, please visit trane. com or tranetechnologies.com. The AHRI Certified mark indicates Trane U.S. Inc. participation in the AHRI Certification program. For verification of individual certified products, go to ahridirectory. org. Trane has a policy of continuous data improvement and it reserves the right to change design and specifications without notice. We are committed to using environmentally conscious print practices. 22-1904-1M-EN 24 Apr 2020 Supersedes 22-1904-1L-EN (October 2019) ©2020 TranePTC Arbortext Publishing Engine PDFlib PDI 9.0.6 (C /Win64); modified using iText 2.1.7 by 1T3XT