Instruction Manual for ROOMBANKER models including: RBSS-TH1915, 2AUXBRBSS-TH1915, 2AUXBRBSSTH1915, RBSS-TH1915 Temperature Humidity Monitor, Temperature Humidity Monitor, Humidity Monitor, Monitor

User Manual

Hangzhou Roombanker Technology Co., Ltd. RBSS-TH1915 Temperature Humidity Monitor 2AUXBRBSS-TH1915 2AUXBRBSSTH1915 rbss th1915


File Info : application/pdf, 6 Pages, 1.10MB

PDF preview unavailable. Download the PDF instead.

GetApplicationAttachment.html?id=7059083
2024/1/15 17:10

Temperature & Humidity Monitor | Roombanker wiki

Environmental Monitoring Sensor

Temperature Humidity Monitor

Specification

Temperature & Humidity Monitor

Download Spec
Last update: January 12th, 2024.
A compact and exquisite temperature and humidity monitor to accurately track your indoor temperature and humidity changes. It supports both Fahrenheit and Celsius versions.

1. Detection Performance

Temperature Range and Accuracy
From -10  to +55  Accuracy at 0.5 

Humidity Range and Accuracy
From 0 to 99%RH Accuracy at 5%

https://wiki.roombanker.com/environmental-monitoring-sensor/temperature-humidity-monitor/specification

1/5

2024/1/15 17:10
2. Features

Temperature & Humidity Monitor | Roombanker wiki

Centigrade and Fahrenheit
Support unit switching between Centigrade and Fahrenheit Depends on sales region.

Remote setting and testing
Setting and testing from RB Link App

Advanced features
Power up enrolling
When T&H monitor is powered up, it will automatically start paring to the hub nearby Find me
When enabled, the T&H monitor starts flashing green, which can help identify the monitor from numerous devices. Signal strength detection
When enabled, T&H monitor starts flashing green/orange/red showing the wireless signal strength between the hub at current installation site. Low battery notification

3. RBF wireless technology
Wireless signal range
Up to 1,900 m in an open space with hub Two-way communication with hub

https://wiki.roombanker.com/environmental-monitoring-sensor/temperature-humidity-monitor/specification

2/5

2024/1/15 17:10
Frequency bands

Temperature & Humidity Monitor | Roombanker wiki

868 MHz Monitor: 863 ~ 870 MHz

915 MHz Monitor: 902 ~ 928 MHz

Depends on sales region.

Wireless signal modulation
FSK / DSSS

Encrypted communication
All the data transmitted are protected by AES-CCM encryption with a random key.

Frequency hopping (FHSS)
To prevent radio interference and radio signal interception.

Time division multiple access (TDMA)
With the help of clock synchronization technology, hub will slice time into different division for different RBF wireless devices. In this way, all devices will communicate with hub in a sequence.

4. Electrical Characteristics
Power Supply
AA Battery× 3 Up to 5 years (standby mode)

5. General

https://wiki.roombanker.com/environmental-monitoring-sensor/temperature-humidity-monitor/specification

3/5

2024/1/15 17:10

Temperature & Humidity Monitor | Roombanker wiki

Operation Temperature

From -10° to +55° (14°F to 131°F)

Operation Humidity
From 0% to 99%

Storage Temperature
From -20°C to 60°C (-4°F to 140°F)

Dimension(WxHxD)
64mm × 64mm × 28mm

Weight
68.5 g

6. Compatibility
Operates with all Roombanker Home Security Hubs, RBF repeaters.

7. Complete set

Product

Quantity

Temperature Humidity Monitor × 1

AA Battery

× 3

Quick Start Guide

× 1

https://wiki.roombanker.com/environmental-monitoring-sensor/temperature-humidity-monitor/specification

4/5

2024/1/15 17:10

Temperature & Humidity Monitor | Roombanker wiki

8. Additional information

Available models
RBSS-TH1-868 RBSS-TH1-915

Certifications
CE, CB FCC ICASA RCM NOM Anatel

Warranty
Replacement and repair within 24 months of the date of sale. Batteries are not covered under warranty.

https://wiki.roombanker.com/environmental-monitoring-sensor/temperature-humidity-monitor/specification

5/5

FCC Statement This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1)This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class B digital device, Pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: · Reorient or relocate the receiving antenna. · Increase the separation between the equipment and receiver. · Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. · Consult the dealer or an experienced radio/TV technician for help.
Caution: Any changes or modifications to this device not explicitly approved by manufacturer could void your authority to operate this equipment.
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator and your body.



References