Instruction Manual for SKC models including: 225-9007, Preloaded Coated Filters, 225-9007 Preloaded Coated Filters, Coated Filters, Filters

Preloaded Coated Filters Cat. No. 225-9007 Operating Instructions Form 40036 PDF

Preloaded, Coated, Filters, Cat., No., 225-9007, Operating, Instructions, Form, 40036, PDF,

SKC Inc.

Coated Filter Instruction 225-9007 (PDF)

Coated Glass Filters Preloaded in Cassettes, Mercuric Acetate | Order High-Quality Coated Glass Filters Preloaded in Cassettes, Mercuric Acetate Products at SKC, Inc.

Preloaded Coated Filters 225-9007 OI

Preloaded Coated Filters 225-9007 Operating Instructions

Preloaded Coated Filters Cat. No. 225-9007 Operating Instructions Form ...

Title: Preloaded Coated Filters Cat. No. 225-9007 Operating Instructions Form 40036 PDF Author: SKC Inc. Subject: Preloaded Coated Filters Cat. No. 225-9007 Operating Instructions Form 40036 PDF


File Info : application/pdf, 2 Pages, 110.85KB

PDF preview unavailable. Download the PDF instead.

Preloaded Coated Filters 225-9007 OI
Preloaded Coated Filters Cat. No. 225-9007 Operating Instructions
SKC coated filters are shipped preloaded in the cassettes with end plugs and shrink bands in place. No assembly is required; they are ready to use. Method & Chemical: OSHA 26 for methyl-mercaptans; NIOSH 2542 for mercaptans (methyl-, ethyl-, n-butyl-); OSHA PV2075 for phenyl-mercaptans Filter & Coating: Glass fiber filter coated with mercuric acetate. Two-piece 37-mm cassette. Closed-face sampling configuration Prior to Sampling: Store at  39.2 F (4 C) for up to 8 months. Sample Stability: Store samples at  39.2 F (4 C) for up to 15 days.
For information on other available coated filters, go to www.skcinc.com.
Form 40036 Rev 211118

How to Use SKC Preloaded Coated Filters
Ensure that filter cassettes are at room temperature before sampling.
1. Select one coated filter cassette for calibrating the flow rate. A red plug secures the inlet, which is clearly marked "inlet," and a blue plug secures the outlet. Set up the sampling train for calibration with the representative filter cassette in line. For "closed-face" sampling, remove the plugs and connect the cassette to the sampling train. For "openface" sampling, remove the outlet plug and the cassette inlet section and then connect the cassette to the sampling train. For details on setting up a sampling train, refer to the SKC Sample Setup Guide "Sampling Train ­ Filters" at www.skcinc.com/knowledgecenter.
2. Calibrate the pump to the desired flow rate using a calibrator.
3. Replace the cassette used for calibration with a fresh coated filter cassette for sample collection. Attach the cassette to a worker's collar, as close to the breathing zone as possible, by using a filter cassette holder SKC Cat. No. 225-1. Sample for the specified time interval and record the time.
4. Remove the filter cassette at the end of the specified sampling period and replace both end plugs (and the inlet if necessary). Recheck the flow rate using the same cassette and calibrator used for calibration in Step 2 to ensure that the flow rate has not changed by more than 5%.
5. Store samples at  39.2 F (4 C) for up to 15 days. Appropriately package samples, blanks, and all pertinent data to send to a laboratory for analysis. Expedite shipping of samples to laboratory. Friday shipments are not recommended.
SKC Limited Warranty and Return Policy SKC products are subject to the SKC Limited Warranty and Return Policy, which provides SKC's sole liability and the buyer's exclusive remedy. To view the complete SKC Limited Warranty and Return Policy, go to skcinc.com/warranty.
Form 40036 Rev 211118



References

Microsoft Word for Microsoft 365