Instruction Manual for RUNZE FLUID models including: SV-07B Injector Valve, SV-07B, Injector Valve, Valve
Resources - Nanjing Runze Fluid Control Equipment Co., LTD.
Injector Valve SV-07B - Nanjing Runze Fluid Control Equipment Co., LTD.
File Info : application/pdf, 18 Pages, 840.53KB
DocumentDocumenthttp://www.runzeliuti.com V 1.2 1 Thank you very much for choosing our product. Please read and keep this manual carefully before use. Table of Contents Chapter 1 Getting Started............................................................................................................................ 3 1.1 Company Profile .................................................................................................................................. 3 Chapter 2 Product Introduction................................................................................................................. 4 2.1 Product Features................................................................................................................................... 4 2.2 Naming Rules.........................................................................................................................................5 2.3 Product Specification............................................................................................................................ 5 2.4 Dimensions (unit: mm)....................................................................................................................... 6 2.5 Technical Parameters........................................................................................................................... 7 2.6 Flow configuration..................................................................................................................................8 2.7 Reset Status........................................................................................................................................... 8 2.8 Port Definition.........................................................................................................................................8 Chapter 3 Description of Control Code....................................................................................................9 3.1 Overview................................................................................................................................................. 9 3.2 Installation and Debugging...................................................................................................................9 3.3 Code Instructions...................................................................................................................................9 3.3.1 Control Command Format............................................................................................................ 9 3.3.2 Command Format Instructions...................................................................................................10 Chapter 4 Common Problems & Solutions...........................................................................................16 Chapter 5 Technical Service..................................................................................... http://www.runzeliuti.com 2 Chapter 1 Getting Started 1.1 Company Profile Nanjing Runze Fluid Control Equipment Co., Ltd. was established in 2014, We are a national high-tech enterprise focusing on R&D and production of fluid accessories for numerous analytical instruments. We engineer, manufacture and market differentiated standard products such as syringe pumps, multiport valves, peristaltic pumps, gastight syringes, plastic fittings, etc.. We persevere in providing our customers with best quality and service in the fields of environmental monitoring, biopharmaceuticals, medical equipment, industrial automation and laboratory instruments, etc. RUNZE attracted experienced talents with strong capability on integrating software and hard-ware at electronic research, mechanical design, mold manufacturing. In past years, we have accumulated rich technical and practical experience that bring us honors of ISO9001, National High-tech Enterprise, Jiangsu Province Private Science and Technology Enterprise, 5A Bank Credit Assessment, 38 technical patents and multiple software copyright including 8 invention patents, 17 utility model patents, 13 design patents. RUNZE Technology Center has a reliable EMC laboratory and a series of advanced processing equipment and testing instruments, such as imported white light interferometer, Keens plane rapid detector, five-axis machining center, high-precision nano-grinding machine, etc., Continuous and substantial investment in research and development, which enabled the company to obtain a huge advantage in the manufacture and sales of analytical instrument accessories. http://www.runzeliuti.com 3 Chapter 2 Product Introduction 2.1 Product Features (1) Name: The injector valve is an electric injector valve independently developed by RUNZE Fluid Control Equipment Co., Ltd., also known as electric rotary valve; (2) Control: By receiving instructions from the host computer to control the operation of the stepper motor to make the rotor turn to the specified port position to achieve the switching of the flow path. Serial communication protocol supports RS232/RS485/CAN bus. (3) Corrosion Resistance: This type of injector valve adopts sapphire valve core, which can be applied to various corrosive liquids. The valve head are made of PCTFE (polychlorotrifluoroethylene) and PPS, maintenance-free; (4) Valve Core Structure: The valve core adopts a multi-directional self-adaptive plane fitting method, which can extend the service life of the product effectively. (This structure has been applied for utility patent, patent number: CN204852471U) (5) Motive power: The rotation of the valve body adopts the imported NMB planetary gearbox motor as the power plant, which is extremely reliable. (6) Orientation: The valve port is oriented by optical encoder, which can effectively solve the problem of inaccurate positioning after the gearbox is worn down. (7) Drive: The two-phase bipolar stepper drive module is a constant current drive chip, which can control the motor current with high efficiency. It has a built-in error detection circuit and error detection (TSD/ISD) signal output function; (8) Control Unit Interface: XH terminal with 2.54mm pitch (9) Mechanical Interface: 1/4-28UNF female thread (10)Usage: Widely used in the collection and distribution of fluid samples (11)Application: Environmental testing devices, experimental analysis instruments, medical analyzers, chromatographic instruments, etc. Before using the injector valve, please read the "Instruction Manual" carefully and follow the provisions in it. http://www.runzeliuti.com 4 2.2 Naming Rules Figure 2-2 Example: Slope type 10-port sapphire injector valve, naming: QHF-SV07B-X-T10-K1.2-S 2.3 Product Specification SV-07B injector valves can be divided into 6 ports, 8 ports, and 10 ports according to the number of channels, as shown in the figure below: 6 ports 8 ports 10 ports Figure 2-3-1 The 6/8/10 ports can be installed in place of other injector valves of our company. The size of the mounting plate is as shown in Figure 2-3-2 (unit: mm). http://www.runzeliuti.com 5 Figure 2-3-2 2.4 Dimensions (unit: mm) 4-M3 Mounting Holes Figure 2-4-1 6/8/10 channels dimensions http://www.runzeliuti.com 6 2.5 Technical Parameters Description Parameter Configuration 6 port 8 port 10 port Orifice 1.2mm 1.2mm 1.2mm Wetted material UFE, Sapphire rotor/stator Dead volume (Port to Port) 28.121L 28.67L 28.129L Dead volume (Sealed rotor) 5.207L 5.756L 5.215L Pressure rating Origin detection Liquid temperature 0-0.3Mpa (air) / 0-1.6Mpa (water) Auto reset to initial position when powered on (this function can be opened or closed) 0-150 Connection 1/4-28UNF Replaceable parts Stator replaceable, sealed rotor irreplaceable Transposition Random start to any specific port Driver Non-optional Valve switching time 2s/circle 2s/circle 3.3s/circle Communication Baud rate Address & Parameter setting RS232/RS485/CAN RS232/RS485: 9600bps, 19200bps, 38400bps, 57600bps, 115200bps CAN: 100Kbps, 200Kbps, 500Kbps, 1Mbps Via communication Power supply DC24V/3A Max. power 60W Operating temperature -10-50 Operating humidity 80% relative humidity, non-condensing Dimension (L*W*H) 60*51*150mm Net weight 0.73kg Liquid Figure 2-5-1 Dead volume (Port to Port) Liquid Figure 2-5-2 Dead volume (Sealed rotor) http://www.runzeliuti.com 7 2.6 Flow configuration Center port is the public port and valve can switch to any specific port by programmable control via RS232/RS485/CAN communication. Flow configuration is shown as below: Figure 2-6 2.7 Reset Status Reset direction: CCW (unchangeable) Reset position: State 1 (as is shown in Figure 2-6) 2.8 Port Definition GND Power light GND Figure 2-8 Port Diagram http://www.runzeliuti.com Port Definition of Driver Board 8 Chapter 3 Description of Control Code 3.1 Overview The data transmission between the injector valve and the host device (computer, single-chip computer, PLC, etc.) adopts serial communication (eg: RS-232/RS-485/CAN bus), the following describes the communication format: the communication adopts asynchronous serial communication, Commands and data frames use sum check, and the sum check is two bytes (2Byte). Commands and data in communication are in hexadecimal number, parameters are stored in little-endian mode. Other instructions: Communication interface: RS-232, RS-485, CAN bus; Communication mode: two-way asynchronous, master-slave mode; Baud rate:RS-232/RS-485: 9600bps, 19200bps, 38400bps, 57600bps, 115200bps; CAN: 100Kbps, 200Kbps, 500Kbps, 1Mbps; Data bits: 8 bits; Parity: none check. Response time <1 second after receiving the command. 3.2 Installation and Debugging (1) Installation and debugging tools, see Instructions for Debugging Toolsfor details (2) Instructions for use, see SV-07B Quick Use Guidefor details 3.3 Code Instructions 3.3.1 Control Command Format a: Valve parameter setting command (factory command) b: Valve parameter query command (common command) c: Valve action command (common command) Table 3-3-1 Send Command (common command) Interpretation of 0xXX: 0x means hexadecimal, XX is a two-digit hexadecimal number. The value inputted into the software all should be XX. http://www.runzeliuti.com 9 The message frame of "Send Command" is 8 bytes, and the complete format is as follows: Start code Address code Function code Parameters End code Sum check BO B1 B2 B3 B4 B5 B6 B7 STX ADDR FUNC 1st byte STX: Start code (0XCC) 1-8 bit 9-16 bit ETX Low byte High byte 2nd byte ADDR: Address of slave device (0x00~0x7F) Multicast Address (0x80~0xFE) Broadcast Address (0xFF) 3rd byte FUNC: Function code 4th and 5th byte: Parameters of function code 6th byte ETX: End code (0xDD) 7th and 8th byte: Sum check code from byte 1 to 6 Note: The above command format refers to the common command. In particular, if a password bit is added to the factory command and the parameter bit has also changed, from the original 2 bytes to 4 bytes, the command format is as follows: The message frame of "Factory Command" is 14 bytes, and the complete format is as follows: Table 3-3-2 Send Command (Factory Command) Start Address Function code code code Password Parameters B0 B1 B2 B3.B4.B5. B6 B7 B8 B9 STX ADDR FUNC PWD 1-8 9-16 17-2 bit bit 4 bit Table 3-3-3 Response Command B10 25-3 2 bit End code B11 ETX Sum check B12 B13 Low High byte byte Start code Address code Status code Parameters End code Sum check B0 B1 B2 B3 B4 B5 B6 B7 STX ADDR STATUS 1-8 bit 9-16 bit ETX Low byte High byte Note: The send command & response command format for the common commands are the same, and all the response command message frames are 8 bytes. 3.3.2 Command Format Instructions Definition of Start Code & End Code B0B5(B11) Item Start code B0 End code B5 (B11) Code 0XCC 0xDD Remark http://www.runzeliuti.com 10 Note: The send command & response command of the common command are the same. The start and the end code are B0 and B5 respectively. The factory command is B11. Definition of Address Bit B1 Item Instruction Code B1 Address Bit Address 0xXX Note: 1. The send command is the same as the response command Remark 2. The XX in "0xXX" means that it can be set, the factory default is 0x00, and the parameter value range is 0x000x7F. Table 3-3-4 Control Command Instructions (B2~B10) A: Valve parameter setting command (factory command) (B2~B10) Command Code B2 0x00 0x01 0x02 0x03 0x0E 0x10 Command Instruction Set address Set RS232 baud rate Set RS485 baud rate Set CAN baud rate Set automatic reset when power-on Set CAN destination address Code (B3, B4, B5, B6) B3=0xFF B4=0xEE B5=0xBB B6=0xAA B3=0xFF B4=0xEE B5=0xBB B6=0xAA B3=0xFF B4=0xEE B5=0xBB B6=0xAA B3=0xFF B4=0xEE B5=0xBB B6=0xAA B3=0xFF B4=0xEE B5=0xBB B6=0xAA B3=0xFF B4=0xEE B5=0xBB B6=0xAA Parameters Instructions (B7, B8, B9, B10) B7=0xXX (B8=0x00 B9=0x00 B10=0x00) The value range of XX is 007F in V1.9 & above version, 00FF in version below V1.9, default value is 00 Totally 5 baud rates: the factory default is 9600bps (B8=0x00 B9=0x00 B10=0x00) B7=0x00 corresponding baud rate 9600bps B7=0x01 corresponding baud rate 19200bps B7=0x02 corresponding baud rate 38400bps B7=0x03 corresponding baud rate 57600bps B7=0x04 corresponding baud rate 115200bps Totally 4 baud rates: the factory default is 100K B8=0x00 B9=0x00 B10=0x00 B7=0x00 corresponding baud rate 100Kbps B7=0x01 corresponding baud rate 200Kbps B7=0x02 corresponding baud rate 500Kbps B7=0x03 corresponding baud rate 1Mbps B7=0x00 means non-automatic reset B7=0x01 means automatic reset Automatically reset to state 1 after power-on (the factory default of injector valve is automatic reset) B7=0xXX (B8=0x00 B9=0x00 B10=0x00) The value range of XX is 00FF, and the default is 00 http://www.runzeliuti.com 11 0x50 0x51 0x52 0x53 0xFC 0xFF Set address of multicast channel 1 B3=0xFF B4=0xEE B5=0xBB B6=0xAA Set address of multicast channel 2 B3=0xFF B4=0xEE B5=0xBB B6=0xAA Set address of multicast channel 3 B3=0xFF B4=0xEE B5=0xBB B6=0xAA Set address of multicast channel 4 B3=0xFF B4=0xEE B5=0xBB B6=0xAA Parameter lock Restore factory settings B3=0xFF B4=0xEE B5=0xBB B6=0xAA B3=0xFF B4=0xEE B5=0xBB B6=0xAA B7=0xXX (B8=0x00 B9=0x00 B10=0x00) The value range of XX is 80FE, and the default is 00 B7=0xXX (B8=0x00 B9=0x00 B10=0x00) The value range of XX is 80FE, and the default is 00 B7=0xXX (B8=0x00 B9=0x00 B10=0x00) The value range of XX is 80FE, and the default is 00 B7=0xXX (B8=0x00 B9=0x00 B10=0x00 The value range of XX is 80FE, and the default is 00 All the parameters are 0x00 All the parameters are 0x00 Example: Use the 0x50/51/52/53 command to set the multicast address (only uses 0x50/51/52 three commands in this example) Use three sets of SV07B injector valves with the same software version. In the RS485 communication mode, set their addresses to 00, 01, 02 and make a mark. Firstly, Set parameter 0x81 of SV07B multicast channel 1 address marked as 00 to 81 by the command 0x50, set parameter 0x81 of multicast channel 2 address to 81 by command 0x51; Set parameter 0x82 of the multicast channel 1 address of SV07B marked as 01 to 82 by command 0x51, and the parameter 0x82 of multicast channel 2 address is set to 82 by command 0x52. Set parameter 0x83 of the multicast channel 1 address of SV07B marked as 00 to 83 by command 0x50, and the parameter 0x83 of multicast channel 3 address to 83 by command 0x52 (See the table below for details) Item Device Multicast address Device1 (address 0) 81(2) Device2 (address 1) 81(2) Broadcast address FF(1) FF(1) Multicast address 82(2) Broadcast address FF(1) FF(1) Multicast address 83(2) Device3 (address 2) FF(1) 82(2) FF(1) 83(2) http://www.runzeliuti.com 12 After the setting is completed, connect the three devices in parallel to the serial debugging tool, and use our debugging tool MotorTest V0.8 for debugging. In MotorTest V0.8, set the address to 0x81, the command to 0x44 and the parameter to 0x02, click to send and then the device 1 and device 2 will have port switching action; Set the address to 0xFF ,the command to 0x44 and the parameter to 0x01, click to send and then the device1.2 3 will all have port switching action; Set the address to 0x82, the command to 0x44, and the parameter to 0x02, click send and then the device 2 and device 3 will have port switching action; Set the address to 0xFF, the command to 0x44, and the parameter to 0x01 , click to send and then the device1.2 3 will all have port switching action; Set the address to 0x83, the command to 0x44, and the parameter to 0x02 , click to send and then the device1 and device 3 will have port switching action; The newly added command to set the multicast address greatly meets the needs of customer groups, making it easier and more convenient for customers. You can choose the device you want to control so that you can complete your work more efficiently and quickly during usage. B: Valve parameter query command (common command) (B2~B4) Command Code B2 Command Instruction Response Parameter (B3, B4) 0x20 Query Address B3=0x00 B4=0x00 0x21 Query RS232 baud rate B3=0x00 B4=0x00 0x22 0x23 Query RS485 baud rate Query CAN baud rate B3=0x00 B4=0x00 B3=0x00 B4=0x00 0x2E Query Automatic reset when power on B3=0x00 B4=0x00 0x30 Query CAN destination address B3=0x00 B4=0x00 0x70 Query multicast channel 1 address B3=0x00 B4=0x00 0x71 Query multicast channel 2 address B3=0x00 B4=0x00 0x72 Query multicast channel 3 address B3=0x00 B4=0x00 0x73 Query multicast channel 4 address B3=0x00 B4=0x00 0x3E 0x3F 0x4A Query current channel address Query current version Query motor status B3=0x00 B4=0x00 B3=0x01 B4=0x09, above is just an example, if the response parameter is the same as above parameter, it means the current version is V1.9, see the version number on the label for details B3=0x00 B4=0x00 http://www.runzeliuti.com 13 Note: After version V1.8, the software sub-version and the main version are merged into one command C: Valve action command (common command) (B2~B4) Command Code B2 Command Instruction Parameter Instructions (B3, B4) 0x44 0x45 0x4F The motor rotates through the code disc, and select the best path automatically Reset Reset on origin position According to the actual number of ports of the injector valve, such as a 10-port injector valve, B3=0xXX B4=0x00,the value range of XX is 010A Note: 6-port State 1 1-6 connected 8-port State1 1-2 connected 10-port State1 1-2 connected B3=0x00 B4=0x00 Injector valve turns to state 2 B3=0x00 B4=0x00 Injector valve runs to the encoder origin position, overlaps the position reset by the 0x45 command 0x49 Forced stop B3=0x00 B4=0x00 Example 1, 0x44: Multi-port position switching (1) Current position: Reset Position Target: Position A, Port 1 is connected with Port 6 Command: 0x44 Parameter: 0x01 After send commands, valve will switch port position, as shown in below Figure 3-1 (2) Current position: Reset Position Target: Position B, Port 1 is connected with Port 2 Command: 0x44 Parameter: 0x02 After send commands, valve will switch port position, as shown in below Figure 3-2 Figure 3-1 Figure 3-2 http://www.runzeliuti.com 14 Sum check (B6, B7) Item Instruction Code (B6 B7) Remark Sum check Sum check 0xXX 0xXX The sum of the header to the end of the package Note: The sum check bit of the factory command is B12, B13 Response parameters are B2 B3 B4. Table 3-2-5 Response Parameters Command Code B2 Command Instruction 0x00 Normal state 0x01 Frame error Parameter Description= B3, B4 B3=0x00 B4=0x00 Example: When using the query command "0x3e", the response command Of B3 B4 =0x01 0x00 ~ 0x0a 0x00 B3=0x00 B4=0x00 0x02 Parameter error B3=0x00 B4=0x00 0x03 Optocoupler error B3=0x00 B4=0x00 0x04 Motor busy B3=0x00 B4=0x00 0x05 Motor stalled B3=0x00 B4=0x00 0x06 Unknown position B3=0x00 B4=0x00 0xFE Task is being executed B3=0x00 B4=0x00 0xFF unknown error B3=0x00 B4=0x00 Note: In RS485 communication, when sending an action command, when code B2 received FE byte means the command is received and is being executed Note: The code B2 in the response command indicates the current running state of the motor. Only when B2=0x00, the motor is in normal operation, other parameters are as shown in the above table, corresponding to different abnormal states respectively. In principle, the motor should be sent the 0X4A command to query the motor status at the end of the motor operation. Only when the B2 parameter in the response command is 00, other commands can be executed correctly. Note: The code parameters of all the above commands are set in little-endian mode. Low data is stored in the low bit of the address and high data is stored in the high bit of the address. http://www.runzeliuti.com 15 Chapter 4 Common Problems & Solutions Phenomenon Not working when powered on Not aspirating after switching Liquid has bubbles No communication The communications sent and received are consistent in RS232 Application Notice: Possible problem Working voltage is not within the specified range The power connection is loose or disconnected Working current is not within the specified range The channel is blocked by particles The connector interface is not tight The TX and RX lines of RS232 are connected reversely or RS485 phase A & phase B are connected reversely TX & RX are in short circuit Solution Check whether the voltage is within the specified range Check the power connection Check whether the current is within the specified range Take out the pump tube and check for blocked particles Replace suitable connector Exchange the TX and RX line sequence of RS232, exchange the A, B phase sequence of RS485 Check if there is a short circuit, if yes, replace the cable Please ensure that the voltage matches the standard voltage of the instrument. Please use original serial port wires Communication RS232, RS485, CAN are under Non-isolation mode, hot swapping unsupported. Please cover the unused ports with suitable coned plugs when laid aside to avoid impurity substance and air Do not disassemble the product parts at will. The tamper-evident label is not guaranteed. Please read above operation instructions and communication protocols carefully. Do not input data randomly. Discard the instrument should be in line with the regulations on the disposal. Dispose of the waste in accordance with national environmental protection requirements. Users should not throw away at will. When using CAN bus protocols to connect multiple devices, please refer to the connection method shown in Figure 4-1 below. http://www.runzeliuti.com 16 Device 1 Device 2 Figure 4-1 Device N When using RS485 protocol to connect multiple devices, please refer to the connection method shown in Figure 4-2 below (CAN resistance is removed) Device 1 Device 2 Figure 4-2 Device N http://www.runzeliuti.com 17 http://www.runzeliuti.com 18