ElectriQ TF29OSCT8RW 29 Inch Tower Fan

USER MANUAL

Thank you for choosing ElectriQ

Please read this user manual before using this air circulator and keep it safe for future reference.

Visit www.electriQ.co.uk for our entire range of Intelligent Electricals.

Contents

SAFETY INSTRUCTIONS

Important!

FEATURES

DIAGRAM

LED Display Control Panel

Air outlet

Front housing

Base

INSTALLATION

  1. Push the two parts of the base together ensuring that the power cable is fed through the center.
  2. Line up the tower fan on the base and fix the 4 screws into position using a screwdriver.
  3. Press the power cable into the two clips in the underside of the base, so that it runs out of the rear of the base.

OPERATION

Once assembled, your fan may be operated by using either the manual controls located on the top of the fan or by your remote control.

CONTROL PANEL AND SETTINGS

1. POWER BUTTON: Used to turn the tower fan ON and OFF.

2. SPEED BUTTON: Press to cycle through the three available fan speeds: Lo – Low Speed, M – Medium Speed, and Hi – High Speed.

3. MODE BUTTON: Press to cycle through the modes.

4. TIMER BUTTON: Press repeatedly to increase the running time in 30-minute intervals. The timer can be set between 30 minutes and 7.5 hours.

5. SWING BUTTON: Press to turn the Swing function on and off. When it is operational, the horizontal direction of the airflow is slowly moved from side to side.

6. FAN SPEED INDICATOR: The corresponding light will illuminate to indicate the current fan speed: I – Low Speed, II – Medium Speed, and III – High Speed.

7. TIMER INDICATOR: When setting the timer, add up the lights to determine the length of timer set. i.e. If the 1hr, 2hr, and 4hr lights are illuminated, the timer is set for 7 hours.

8. MODE INDICATOR: One light will illuminate to indicate the current mode which is operating.

REMOTE CONTROL

The buttons on the remote have the same effect as the buttons on the main control panel.

Button Function
1 Power Button
2 Speed Button
3 Swing Button
4 Timer Button
5 Mode Button

The remote contains a button cell battery (CR2025).

MAINTENANCE

CLEANING AND STORAGE

ATTENTION: Please shut off the unit and unplug from the mains before cleaning or performing any maintenance.

Cleaning the surface

Clean the grills with a duster or a soft wet cloth.

Do not use chemical solvents (such as benzene, alcohol, or gasoline) as they may cause irreversible damage. Make sure no water enters the control panel or fan motor.

Do not run the unit until completely dry.

Place the fan in its original box or cover the fan to protect it from dust. Store it in a cool, dry place.

TROUBLE SHOOTING

Do not repair or disassemble the unit by yourself; unauthorized repair attempts will invalidate the warranty and may cause bodily harm.

Issue Possible Reason Solution
No power 1. Power cord is unconnected.
2. There is no power from socket.
3. The power switch is not on.
4. The fuse has blown.
1. Connect the power cord.
2. Check socket is turned on.
3. Turn the unit on.
4. Replace the fuse in the plug.
Odour from unit 1. New unit. When the unit is used for the first time, the fan motor may produce an odour which will dissipate within a week of use. 1. No action required.
Strong vibrations and noise 1. Fan is not used on a flat surface.
2. Fan may be damaged.
1. Place on a flat surface. May put an anti-vibration matt underneath.
2. If fan is damaged, discontinue use and contact service centre.

If the above solutions do not resolve the problem, please contact the service centre.

Energy Saving and Unit Safety Protection Tips

APPENDIX

Disposal: Do not dispose of this product as unsorted municipal waste. Collection of such waste must be handled separately as special treatment is necessary.

Recycling facilities are now available for all customers at which you can deposit your old electrical products. Customers will be able to take any old electrical equipment to participating civic amenity sites run by their local councils. Please remember that this equipment will be further handled during the recycling process, so please be considerate when depositing your equipment. Please contact the local council for details of your local household waste recycling centres.

TECHNICAL DATA

Description Value Unit
Model TF29OSCT8RW
Fan Speeds 3
Cable length 1.5 Meters
Rated Input 45 Watt
Running Current 0.2 Amps
Air Flow 19.45 m³/min
Noise Max 52.9 dB (A)
Power Supply 220-240 / 50-60 V/Hz
Net Weight 2.7 kg
Gross Weight 3.2 kg
Net Size (assembled) 270 x 272 x 745 mm
Gross Size (packed) 760 x 200 x 187 mm
Description Symbol Value Unit
Maximum Fan Flow Rate F 19.45 m³/min
Fan Power Input P 36.3 W
Service Value SV 0.59 (m³/min)/W
Standby power consumption PSB 0.47 W
Fan sound power level LWA 52.9 dB(A)
Maximum Air Velocity C 2.68 meter/sec
Measurement standard for service value IEC 60879:1986+cor1:1992

ElectriQ UK SUPPORT

www.electriQ.co.uk/support

Please, for your own convenience, make these simple checks before calling the service line.

If the unit still fails to operate call: 0330 390 3061 or complete the online form.

  1. Is the unit plugged into the mains?
  2. Is the fuse OK?
  3. Switch the unit off and wait three minutes to see if the issue is resolved. Restart the unit.

Office hours: 9AM - 5PM Monday to Friday

www.electriQ.co.uk
Unit J6
Lowfields Way
Elland
West Yorkshire
HX5 9DA

Models: 29 Inch Tower Fan, TF29OSCT8RW

File Info : application/pdf, 10 Pages, 455.07KB

PDF preview unavailable. Download the PDF instead.

TF29OSCT8RW 20210331

References

Microsoft Word 2019

Related Documents

Preview electriQ 13 Inch Tower Fan User Manual - TF13OSCW, TF13OSCB
User manual for the electriQ 13 Inch Tower Fan models TF13OSCW (White) and TF13OSCB (Black), covering safety instructions, features, operation, maintenance, troubleshooting, and technical specifications.
Preview electriQ Pure Cool Tower Air Purifier User Manual - IQ-PURECOOLB & IQ-PURECOOLS
This user manual provides comprehensive instructions for the electriQ Pure Cool Tower Air Purifier, covering models IQ-PURECOOLB (Black) and IQ-PURECOOLS (Silver). It details safety precautions, product features, operating instructions, maintenance, troubleshooting, and technical specifications.
Preview electriQ ECOSILENT12W 12,000 BTU Portable Air Conditioner User Manual
Comprehensive user manual for the electriQ ECOSILENT12W portable air conditioner. Learn about its 12,000 BTU cooling capacity, 3-in-1 functions (cooling, fan, dehumidifier), WiFi control, installation, operation, and maintenance.
Preview ElectriQ SILENT10 Portable Air Conditioner User Manual
Comprehensive user manual for the ElectriQ SILENT10 portable air conditioner, covering safety instructions, installation, operation, maintenance, troubleshooting, and technical specifications. Learn how to set up, use, and care for your device.
Preview electriQ Portable Air Conditioner User Manual (P12C, P15C)
Comprehensive user manual for electriQ P12C and P15C portable air conditioners, covering safety, installation, operation, maintenance, troubleshooting, and technical specifications.
Preview electriQ ECOSILENT Portable Air Conditioner User Manual
User manual for electriQ ECOSILENT portable air conditioners (ECOSILENT12, ECOSILENT12E, ECOSILENT14). Covers safety, features, installation, operation, maintenance, troubleshooting, and technical specifications.
Preview electriQ SF8000E Portable Air Conditioner User Manual
This user manual provides detailed instructions for the electriQ SF8000E 7,000 BTU Portable Air Conditioner, covering safety guidelines, installation, operation modes, remote control functions, maintenance, troubleshooting, and technical specifications.
Preview ElectriQ SILENT12 Portable Air Conditioner User Manual
User manual for the ElectriQ SILENT12 portable air conditioner, covering safety instructions, operation modes (cooling, dehumidifying, fan), remote control functions, maintenance, troubleshooting, and technical specifications.