User Guide for DrayTek models including: Vigor167, Vigor167 35b Modem, Vigor167, 35b Modem, Modem
File Info : application/pdf, 14 Pages, 2.01MB
DocumentDocumentVigor167 35b Modem Quick Start Guide Version: 1.3 Firmware Version: V5.2.5 (For future update, please visit DrayTek web site) Date: December 9, 2024 i Intellectual Property Rights (IPR) Information Copyrights Trademarks © All rights reserved. This publication contains information that is protected by copyright. No part may be reproduced, transmitted, transcribed, stored in a retrieval system, or translated into any language without written permission from the copyright holders. The following trademarks are used in this document: Microsoft is a registered trademark of Microsoft Corp. Windows 8, 10, 11 and Explorer are trademarks of Microsoft Corp. Apple and Mac OS are registered trademarks of Apple Inc. Other products may be trademarks or registered trademarks of their respective manufacturers. Safety Instructions and Approval Safety Instructions Warranty Read the installation guide thoroughly before you set up the modem. The modem is a complicated electronic unit that may be repaired only by authorized and qualified personnel. Do not try to open or repair the modem yourself. Do not place the modem in a damp or humid place, e.g. a bathroom. Do not stack the modems. The modem should be used in a sheltered area, within a temperature range of 0 to +45 Celsius. Do not expose the modem to direct sunlight or other heat sources. The housing and electronic components may be damaged by direct sunlight or heat sources. Do not deploy the cable for LAN connection outdoor to prevent electronic shock hazards. Do not power off the router when saving configurations or firmware upgrades. It may damage the data in a flash. Please disconnect the Internet connection on the router before powering it off when a TR-069/ ACS server manages the router. Keep the package out of reach of children. When you want to dispose of the modem, please follow local regulations on conservation of the environment. We warrant to the original end user (purchaser) that the modem will be free from any defects in workmanship or materials for a period of two (2) years from the date of purchase from the dealer. Please keep your purchase receipt in a safe place as it serves as proof of date of purchase. During the warranty period, and upon proof of purchase, should the product have indications of failure due to faulty workmanship and/or materials, we will, at our discretion, repair or replace the defective products or components, without charge for either parts or labor, to whatever extent we deem necessary tore-store the product to proper operating condition. Any replacement will consist of a new or re-manufactured functionally equivalent product of equal value and will be offered solely at our discretion. This warranty will not apply if the product is modified, misused, tampered with, damaged by an act of God, or subjected to abnormal working conditions. The warranty does not cover the bundled or licensed software of other vendors. Defects that do not significantly affect the usability of the product will not be covered by the warranty. We reserve the right to revise the manual and online documentation and to make changes from time to time in the contents hereof without obligation to notify any person of such revision or changes. Model: Vigor167 Power Consumption4.4W (Max.) Power Input: 12V 0.4A Manufacturer: DrayTek Corporation Address: No. 26, Fushing Rd, Hukou, Hsinchu Industrial Park, Hsinchu 303, Taiwan ii EU Declaration of Conformity Hereby, DrayTek Corporation declares that the equipment type Vigor167 is in compliance with EU EMC Directive 2014/30/EU, Low Voltage Directive 2014/35/EU and RoHS 2011/65/EU. The full text of the EU Declaration of Conformity is available at the following internet address: https://fw.draytek.com.tw/Vigor167/Document/CE/ Product name: 35b Modem Model number: Vigor167 Manufacturer: DrayTek Corp. Address: No.26, Fushing Rd., Hukou, Hsinchu Industrial Park, Hsinchu 303, Taiwan Declaration of Conformity Hereby, DrayTek Corporation declares that the equipment type Vigor167 is in compliance with The Electromagnetic Compatibility Regulations 2016 (SI 2016 No.1091), The Electrical Equipment (Safety) Regulations 2016 (SI 2016 No.1101), and The Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment Regulations 2012 (SI 2012 No. 3032). The full text of the EU Declaration of Conformity is available at the following internet address: https://fw.draytek.com.tw/Vigor167/Document/CE/ Product name: 35b Modem Model number: Vigor167 Manufacturer: DrayTek Corp. Address: No.26, Fushing Rd., Hukou, Hsinchu Industrial Park, Hsinchu 303, Taiwan Importer: UK - CMS Distribution Limited, 15 Worship Street, London, EC2A 2DT Ireland - CMS Distribution Limited, Bohola Road, Kiltimagh, Co Mayo, Ireland Regulatory Information This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device may accept any interference received, including interference that may cause undesired operation. USA Local Representative Company name Address ZIP Code Contact Person ABP International Inc. 13988 Diplomat Drive Suite 180 Dallas TX 75234 75234 E-mail henry@abptech.com Mr. Henry N Castillo Tel. (972)831-1600 140 For more updates, please visit www.draytek.com. iii *The external power supply used for each product will be model dependent. 1 2 3 4 5 6 7 8 9 10 11 12 A Manufacturer CWT CWT CWT CWT CWT APD APD APD APD MOSO MOSO MOSO Sangtai Sangtai Sangtai Industrial Industrial Industrial Park, Park, Park, No. 222, Sec. No. 222, Sec. No. 222, Sec. No. 222, Sec. No. 222, Sec. Guanwai Guanwai Guanwai 2, Nankan 2, Nankan 2, Nankan 2, Nankan 2, Nankan No.5, Lane No.5, Lane No.5, Lane No.5, Lane Xiaobaimang Xiaobaimang Xiaobaimang Rd., Lujhu Rd., Lujhu Rd., Lujhu Rd., Lujhu Rd., Lujhu 83, Lung-Sou 83, Lung-Sou 83, Lung-Sou 83, Lung-Sou Songbai Songbai Songbai B Address Township, Township, Township, Township, Township, St., Taoyuan St., Taoyuan St., Taoyuan St., Taoyuan Road, Road, Road, Taoyuan Taoyuan Taoyuan Taoyuan Taoyuan City 330, City 330, City 330, City 330, Nanshan Nanshan Nanshan County 338, County 338, County 338, County 338, County 338, Taiwan Taiwan Taiwan Taiwan District, District, District, Taiwan Taiwan Taiwan Taiwan Taiwan 518108 518108 518108 Shenzhen, Shenzhen, Shenzhen, Guangdong, Guangdong, Guangdong, China China China C Model identifier 2ABB012F UK 2ABB018F UK 2ABL024F UK 2ABL030F UK 2ABN036F UK WA-12M12FG WB-18D12FG WA-24Q12FG WA-36A12FG 2ABB012F EU 2ABB018F EU 2ABL024F EU 2ABL030F EU 2ABN036F EU WA-12M12FK WB-18D12FK WA-24Q12FK WA-36A12FK MSV2000R120024Q0-GB MSV2000R120024Q0-DE MSSV2500WR120 030E0-GB MSSV2500WR120 030E0-DE V30-V3000R1 2 0-036T0-GB V30-V3000R1 2 0-036T0-DE D Input voltage 100~240V 100~240V 100~240V 100~240V 100~240V 100~240V 100~240V 100~240V 100~240V 100~240V 100~240V 100~240V E Input AC frequency Output voltage DC 50/60Hz 12.0V F Output current 1.0A G Output power 12.0W Average H active 84.9% efficiency I Efficiency at low load 10% 73.6% No-load J power 0.07W consumption 50/60Hz 12.0V 1.5A 18.0W 86.2% 78.0% 0.07W 50/60Hz 12.0V 2.0A 24.0W 87.6% 81.3% 0.07W 50/60Hz 12.0V 2.5A 30.0W 87.8% 83.3% 0.07W 50/60Hz 12.0V 3.0A 36.0W 89.8% 83.7% 0.07W 50/60Hz 12.0V 1.0A 12.0W 83.7% 74.5% 0.07W 50/60Hz 12.0V 1.5A 18.0W 85.4% 80.5% 0.10W 50/60Hz 12.0V 2.0A 24.0W 88.6% 86.4% 0.07W 50/60Hz 12.0V 3.0A 36.0W 88.2% 85.4% 0.10W 50/60Hz 12.0V 2.0A 24.0W 87.8% 85.4% 0.10W 50/60Hz 12.0V 2.5A 30.0W 89.5% 84.7% 0.08W 50/60Hz 12.0V 3.0A 36.0W 89.3% 87.7% 0.10W External power supply (Power Adapter) information. For more updates, please visit www.draytek.com. iv Table of Contents 1. Package Content .................................................................................................. 1 2. Panel Explanation................................................................................................. 2 3. Hardware Installation ........................................................................................... 3 3.1 Network Connection ................................................................................................................... 3 3.2 Wall-Mounted Installation ........................................................................................................... 4 4. Software Configuration ........................................................................................ 5 5. Customer Service ................................................................................................. 9 v 1. Package Content Take a look at the package content. If there is anything missed or damaged, please contact DrayTek or dealer immediately. Modem Quick Start Guide RJ-45 Cable (Ethernet) RJ-11 to RJ-11 Cable or RJ-11 to RJ-45 Cable The type of the power adapter depends on the country that the modem will be installed. * The maximum power consumption is 4.8 Watt. UK-type Power Adapter EU-type Power Adapter USA/Taiwan-type Power Adapter AU/NZ-type Power Adapter 1 2. Panel Explanation LED ACT P1/P2 DSL Status Off Blinking On Off Blinking On Blinking Explanation The system is not ready or is failed. The system is ready and can work normally. A normal connection is through its corresponding port. LAN is disconnected. Data is transmitting (sending/receiving). xDSL connection synchronized. xDSL connection is synchronizing. Interface PWR ON/OFF Factory Reset P2-P1 DSL Description Connecter for a power adapter. ON/OFF: Power switch. Restore the default settings. Usage: Turn on the modem. Press the button and keep for more than 10 seconds. Then the modem will restart with the factory default configuration. Connecter for local networked devices. Connecter for accessing the Internet through xDSL. Note Remove the protective film from the router before use to ensure ventilation. 2 3. Hardware Installation This section will guide you to install the modem through hardware connection and configure the modem's settings through web browser. Before starting to configure the modem, you have to connect your devices correctly. 3.1 Network Connection 1. Connect the DSL interface to the MODEM port of external splitter with a DSL line cable. (splitter) 2. Connect the LAN port to your computer with a RJ-45 cable. 3. Connect one end of the power adapter to the Power port of this device. Connect the other end to the wall outlet of electricity. 4. Power on the modem. 5. Check the POWER, ACT, LAN, DSL and INTERNET LEDs to assure network connections. (For detailed information on LED status, please refer to section 2.) 3 3.2 Wall-Mounted Installation Vigor167 has keyhole type mounting slots on the underside. 1. Drill the holes on the wall according to the recommended instruction. 2. Fit screws into the wall using the appropriate type of wall plug. Note The recommended drill diameter shall be 6.5mm (1/4"). 3. When you finished the above procedure, the modem has been mounted on the wall firmly. 4 4. Software Configuration To access the Internet, please finish the basic configuration after completing the hardware installation. 1. Make sure your PC connects to this device correctly. 2. Open a web browser on your PC and type http://192.168.1.1. A pop-up window will open to ask for a username and password. Please type "admin/admin" as the Username/Password and click Login. Note Please set up the IP address of the computer to be the same subnet as the default IP address of Vigor device 192.168.1.1. 3. Next, the page will appear to guide you change the login password. 5 4. You MUST change the login password before accessing the web user interface. Please set a new password for network security. 5. After clicking Apply, the Main Screen will pop up. 6 6. Open Operation Mode to open the following page. Select Modem Mode and click Next. 7. In this page, configure the system time settings. Then click Next. 7 8. For the Internet connection, configure the settings based on the information from your ISP. Then click Next to get the next page. 9. From the following page, change LAN settings if required. Then click Next. 10. Now, click Apply & Reboot to activate the settings. 8 5. Customer Service If the modem still cannot work correctly after trying many efforts, please contact your dealer for further help right away. For any questions, please feel free to send an e-mail to support@draytek.com. Be a Registered Owner Web registration is preferred. You can register your Vigor modem via https://myvigor.draytek.com. Firmware & Tools Updates Due to the continuous evolution of DrayTek technology, all devices will be regularly upgraded. Please consult the DrayTek website for more information on the newest firmware, tools, and documents. https://www.draytek.com 9