User Manual for BLUETTI models including: AC500, B300S, AC500 B300S Partial Home Backup System, AC500 B300S, Partial Home Backup System, Home Backup System, Backup System, System
BLUETTI AC500 B300S | Whole-Home Battery Backup Power| 5000W Pure Sine Wave Inverter
User Guide - BLUETTI
File Info : application/pdf, 20 Pages, 2.34MB
DocumentDocumentHow to build a partial home backup system with AC500+B300S User Manual 1 How to build a partial home backup system with AC500+B300S Thank You! Thank you for making BLUETTI a part of your family. From the very beginning, BLUETTI has tried to stay true to a sustainable future through green energy storage solutions for both indoor and outdoor use while delivering an exceptional eco-friendly experience for our homes and our world. That's why BLUETTI makes its presence in 70+ countries and is trusted by millions of customers across the globe. Netherlands Germany Franch Contents 1. 120 Volts AC500+B300S Backup System 01 2. 240 Volts AC500+B300S Backup System 04 3. Accessories 11 3.1 Transfer switch 11 3.2 50A AC Charging Cable 11 3.3 BLUETTI AC500 split-phase output cable 12 3.4 BLUETTI AC500 split-phase AC charging cable 12 3.5 Communication cable for split-phase function 13 3.6 NEMA 14-50R socket 13 3.7 NEMA 14-50P to SS2-50R extension cord 13 4. How to install Reliance Controls 14 Please refer to Reliance Controls website: www.reliancecontrols.com 14 4.1 How to install Reliance Controls ProTran2 - Part1, Tools and Planning 14 4.2 How to install Reliance Controls ProTran2 - Part2, Mounting 14 4.3 How to install Reliance Controls ProTran2 - Part3, Wiring 14 4.4 How to install Reliance Controls ProTran2 - Part4, Replacing Circuit Breakers 14 4.5 How to install Reliance Controls ProTran2 - Part5, Installing The Power Inlet Box 14 4.6 How to install dd Controls ProTran2 - Part6, How To Operate 14 5. More information: 14 Declaration · The installation should be performed by a licensed electrician. Improper installation may result in death or serious injury and property damage. · This document is provided for reference purpose ONLY and does not constitute legal advice. Please consult the local licensed electrician for details. BLUETTI shall not be liable for any damage or injury caused by improper installation of the backup system. 1. 120 Volts AC500+B300S Backup System AC500+B300S's Machine Type is set to "Single Phase" by default. DO NOT change this setting if you are operating a single AC500+B300S set. To build the backup system, you need the following: Accessories Transfer switch: Reliance TRK0505BR NEMA 14-50P to SS2-50R cord AC charging cable Qty. 1 1 1 How to build a partial home backup system with AC500+B300S (Only for US standard) 01 Refer to the diagram below for proper installation of AC500+B300S backup system. Normal Load Main Panel 1. NEMA 14-50 Outlet 2. NEMA SS2-50 Power Inlet Box 3. AC500 Input Cable 4. AC500 Output Cable Sub Panel 2 SS2-50 1 14-50 3 4 Essential Load 02 How to build a partial home backup system with AC500+B300S (Only for US standard) 240V Utility Power N L1 L2 L1 L2 N PE N N L Normal PE load N L Essential PE load PE 50A 50A Main Panel N L1 PE 50A Interlock Breaker 50A Sub Panel N L2 PE NEMA 14-50 Socket SS2-50 Inlet NOTE: · The backup system must be properly installed by a licensed electrician. · Please check the voltage at outlets before plugging in your household appliances. · It is a electrical schematic. For the actual wiring diagram, please refer to Reliance PRO/TRAN2 installation instructions. How to build a partial home backup system with AC500+B300S (Only for US standard) 03 2. 240 Volts AC500+B300S Backup System You can build the 240V Split Phase System by pairing two sets of AC500+B300S together. The system also has double the available output power and capacity. Besides TWO sets of AC500+B300S, you also need the following: Accessories Transfer switch: Reliance TRK0505BR AC500 split-phase output cable NEMA 14-50 socket AC500 split phase AC charging cable Qty. 1 1 1 1 Before installing the Reliance Controls transfer switch system, please make a emergency energy plan that includes which appliances you need during a power outage. It is highly recommended to "balance the load" between the two phases of transfer switch, that's to say, do not connect high-wattage appliances centrally to a single AC500+B300S set. 04 How to build a partial home backup system with AC500+B300S (Only for US standard) Main Panel Sub Panel 1 3 1. NEMA 14-50 Outlet 2. NEMA SS2-50 Power Inlet Box 3. AC500 Split-phase Input Cable 4. AC500 Split-phase Output Cable 2 NEMA 14-50 4 SS2-50 Normal Load Essential Load Split Phase Backup System Caution! The backup split phase system must be properly installed by a licensed electrician. How to configure the AC500+B300S sets: Step 1: Pull the AC input cable , turn off both AC500+B300S sets . Step 2: Connect AC500+B300S sets to transfer switch via the AC500 split-phase output cable. One NEMA 14-50 plug goes to a set. Step 3: Connect two AC500 units via the communication cable. Step 4: Turn on either AC500+B300S set. How to build a partial home backup system with AC500+B300S (Only for US standard) 05 Step 5: Go to "Settings" and tap "Next". Step 6: Tap "Single Phase", the machine type option pops up and select "Split phase". · Machine Type: Select Split Phase. or ing Mo e et to tan ar P Step 7: Select the "Master" in the Machine Address pop up. Step 8: Turn on the other AC500+B300S set. Repeat step 5 and 6 to set its machine type to "Split phase". or ing Mo e et to tan ar P 06 How to build a partial home backup system with AC500+B300S (Only for US standard) Step 9: Select the "Slave" in the Machine Address pop up. If the connection fails, clear the alarm history, wait for a moment and check again. Please watch the video from: https://www.youtube.com/watch?v=quvcX8mEUCo NOTE: · Disconnect the AC charging cables from AC500+B300S sets before connecting to the transfer switch. · The split phase system can be controlled ONLY on the "Master" set. · If one of the AC500+B300S sets is out of power, the split phase system fails automatically. NOTE: · The backup system must be properly installed by a licensed electrician. · Please check the voltage at outlets before plugging in your household appliances. · It is a electrical schematic. For the actual wiring diagram, please refer to Reliance PRO/TRAN2 installation instructions. · In the main panel, two Neutral/Ground bus bars have been connected together with copper strips. How to build a partial home backup system with AC500+B300S (Only for US standard) 07 Connect the AC500+B300S sets to the main panel Charge the 240V split phase system with AC500 split phase AC charging cable. Plug the cable to a NEMA 14-50 socket (240V )and the other two connectors into AC500s' AC input ports. The AC input ports should be connected to L1/N/PE and L2/N/PE, respectively. The current capacity of AC input plug shall be 50A. X(L1) W(N) Y(L2) G(PE) L1 PE L2 N AC500 split-phase AC charging cable L1 N PE L2 N PE WRONG CONNECTION Warning! DO NOT charge AC500+B300S with standard AC charging cable in the split phase system, as this may cause damage to the batteries inside B300s and invalidate your warranty. 08 How to build a partial home backup system with AC500+B300S (Only for US standard) L: Live wire N: Neutral wire X(L1) W(N) G(PE) L1 PE N X(L1) W(N) G(PE) L1 PE N How to build a partial home backup system with AC500+B300S (Only for US standard) 09 NOTE: The split phase system supports charging via solar panels. You can charge it by PV and the AC500 split-phase AC charging cable simultaneously. (AC input only through 10 How to build a partial home backup system with AC500+B300S (Only for US standard) 3. Accessories 3.1 Transfer switch Recommendation: Reliance Controls TRK0505BR transfer switch. https://www.bluettipower.com/collections/accessories 3.2 50A AC Charging Cable https://www.bluettipower.com/collections/accessories How to build a partial home backup system with AC500+B300S (Only for US standard) 11 3.3 BLUETTI AC500 split-phase output cable https://www.bluettipower.com/collections/accessories NEMA 14-50P NEMA 14-50P SS2-50R 3.4 BLUETTI AC500 split-phase AC charging cable https://www.bluettipower.com/collections/accessories 12 How to build a partial home backup system with AC500+B300S (Only for US standard) 3.5 Communication cable for split-phase function Please buy it from BLUETTI official store. https://www.bluettipower.com/products/communication-cable-for-split -phase-function 3.6 NEMA 14-50R socket For charging the 240V AC500+B300S split phase system. https://www.bluettipower.com/collections/accessories 3.7 NEMA 14-50P to SS2-50R extension cord For connecting AC500+B300S to the sub panel. https://www.bluettipower.com/collections/accessories NEMA 14-50P SS2-50R How to build a partial home backup system with AC500+B300S (Only for US standard) 13 4. How to install Reliance Controls Please refer to Reliance Controls website: www.reliancecontrols.com 5. More information: Website: www.bluettipower.com Email: service@bluettipower.com 14 How to build a partial home backup system with AC500+B300S (Only for US standard) P/N:17.0303.0557-00A0