Installation Guide for PacLights models including: RKTF Series, RKTF Series Troffer LED Retrofit Kit, Troffer LED Retrofit Kit, LED Retrofit Kit, Retrofit Kit, Kit

PacLights RKTF (Gen.2) Installation Guide

PacLights

RKTF series (RKTF/2) Installation Guide

RKTF series Troffer LED Retrofit Kit - PacLights


File Info : application/pdf, 2 Pages, 639.94KB

PDF preview unavailable. Download the PDF instead.

PL INST RKTF2
INSTALLATION GUIDE RKTF/2 Troffer LED Retrofit Kit

IMPORTANT

SAFETY PRECAUTIONS · Avoid testing this LED light with any electric generator. · Ensure installation adheres to local, regional, and national laws and
regulations. · Always disconnect power before installation or maintenance. · Proper grounding is essential for safety.

INSTALLATION NOTE · Installation should only be performed by individuals with electrical
expertise to prevent potential electrical shock or fire hazards. · Wear gloves during the installation to prevent injuries. · In case of any visible smoke or sparking from the wire, immediately
disconnect the power and alert the appropriate personnel.

DIMMING FUNCTION · This LED light is equipped with a dimming function. · The light features three available dimming methods:0-10VDC or 1-10VDC constant current dimming. PWM signal dimming. Resistance-based dim-
ming. (Choose the appropriate dimming method based on your requirements. You may also opt not to utilize the dimming function.) · Make your selection based on wire connection preferences, desired dimming methods, and the specific LED fixture purchased.

WIRING
Verify input AC voltage before connect. Separate and cap the 0/1-10V dimming wires if opt not to utilize the dimming function.

VIOLET ( DIM + )

PINK ( DIM - )

BLACK/BROWN (HOT)

0-10v DIMMING

WHITE/BLUE (NEUTRAL) INPUT FIXTURE
GREEN/YELLOW (GROUND)

THE KIT
The Troffer Retrofit Kit (Figure 3) provides the ideal way to replace existing 2x2, 2x4, 1x4 recessed troffers, by utilizing the existing fixture housing. The kit provides all the components needed to perform the change out quickly and efficiently, allowing for system upgrades without disturbing the ceiling. The LED troffer retrofit is completely assembled within the frame. With its special design, the kit fits for both air return troffers and standard troffers.
FIG.3 B
C

SELECT WATTAGE and/or COLOR
Selected models are wattage and color (CCT) selectable. The dip switches are located to the back of the retrofit kit assembly. Adjust the settings for wattage (Figure 1) and light color (CCT) (Figure 2) as needed.

A

D

Parts

QTY

A

End Plates

2

B

Side Plates

2

C

Door Assembly body

1

D

Self-tapping Screws

4

Fixture Fromfactor 2' x 2' 2' x 4' 1' x 4'

Overall Inner Dimensions 610mm x 608mm x 78mm H 1220mm x 608mm x 78mm H 1220mm x 302mm x 78mm H

NOTE: the housing of the existing fluorescent luminaries should have an overall inner dimensions larger than in this table.

FIG.2

FIG.1

SENSOR/CONTROL INSTALLATION
The RKTF is equipped with a sensor/control receptacle. To install the sensor or control device, first remove the protective cap located at the front of the fixture. This can be done using a Philips screwdriver. Once the cap is removed, gently connects the control cable to the sensor/control, and insert the sensor/control into the opening.

Need help? (800) 988 -6386 Email: CS@PacLights.com Website: www.PacLights.com
Instructions and specifications are subject to change at any time without notice. Copyright© 2024 PacLights All Rights Reserved

Page 1 of 2

INSTALLATION GUIDE RKTF/2 Troffer LED Retrofit Kit

RETROFIT

1 Step 1: Preparation Ensure all power is disconnected before installation. Remove existing fixture components (lens/lens frame, parabolic louver, reflectors/ballast covers, brackets, lamps/lamp holders). Retain supply and grounding leads. Note: Dispose of lamps and components in compliance with federal and local regulations. (Figure 4)

4 Step 4: Door Assembly Placement Align the door assembly body with the keyholes of the end brackets. Slide it horizontally to the end of the slots. (Figure 7)

FIG.7

FIG.4
2 Step 2: Installing End Brackets Attach LED panel end brackets at each end of the fixture. Lift the fixture slightly and place the brackets between the fixture and T-grid. (Figure 5)

5 Step 5: Safety and Wiring Attach safety cables to the holes in the end brackets. Connect wire leads of the troffer kits to the main power leads using wire caps (Black to Live, White to Neutral, Green to Grounding). (Figure 8)

FIG.8

FIG.5
3 Step 3: Adjusting for Gaps If a gap is present between the fixture and T-grid, install LED panel side brackets for a snug fit. Insert the two tabs of the side brackets into the slots of the end brackets. Secure the brackets using the provided #8x1/2" self-drilling screws. (Figure 6)

6 Step 6: Securing the Assembly Lock the door assembly body in place using the latches riveted on each
end of the door frame. (Figure 9)

FIG.6

FIG.9

7 Final Check Ensure all components are securely installed and check connections
before restoring power.

Need help? (800) 988 -6386 Email: CS@PacLights.com Website: www.PacLights.com
Instructions and specifications are subject to change at any time without notice. Copyright© 2024 PacLights All Rights Reserved

Page 2 of 2

