Danfoss | 087N7933 | Programmable Room Thermostats | White
TP5000 Si Range Electronic Programmable Thermostats now with additional features · Mains Powered Versions · Service Interval Function · Factory Set Clock · Automatic BST/GMT Time Change · Stylish modern design · Large easy to read LCD display · Easy to programme and operate · Available in hard-wired, wireless and remote sensor versions · Battery powered versions for ease of installation · Many additional advanced features www.heating.danfoss.co.uk TP5000 Si Range Electronic Programmable Thermostats The TP5000 Si is an easy to install-and-use 5/2 day programmable room thermostat which o ers up to six time and temperature changes each day with di erent programmes for weekdays and weekends. However the TP5000 Si goes far beyond this. Mains or battery powered for ease of installation, the TP5000 Si has a large, easy-to-read LCD display. It is easy to programme and operate because of a builtin switching programme that the user can easily change to suit individual heating requirements. The TP5000 Si is also available in battery powered, hard-wired and wireless (RF) versions. A big plus with the TP5000 Si is that it incorporates a real time clock and calendar function which eliminates the need for time-setting and BST/GMT time changes. Time and date are factory-set making time setting or adjustment unnecessary. Chrono-proportional control is the standard setting for the TP5000 Si but advanced conventional ON/OFF control is an installer-set option. This modulating control mode uses a cycling pattern within which boiler on/o percentages are varied to satisfy heating requirements. Chrono-proportional cycling rates of 3, 6, 9 or 12 per hour can be selected. Service Interval function The optional Service Interval function incorporated into the TP5000 Si helps landlords meet the boiler servicing requirements of Gas Safety Regulation 36. The unit provides audible and visual warnings from 28 days before servicing is due and ultimately reduces the heating output should the due date pass. Full heating operation can only be restored by an authorised installer. Other features Some other features of the TP5000 Si are: · Mains, battery-powered hard-wired and RF versions. · Selectable 6, 4 or 2 events per day. · Programmable remote sensor inputs including remote room sensing, limit sensing for oor TP5000-RF Si & RX1 Receiver 087N791400 heating applications and tele-switch or window switch sensing. · Selectable operating modes 5/2 day, 24 hour or A/B block programming. · Fixed time, delayed start or optimum start options. · All user settings, including overrides, stored in nonvolatile memory independent of battery state. · Thermostat mode and frost protection. Hard-wired versions TP5000 Si TP5000A Si Code No. 087N791000 087N791100 Wireless versions TP5000-RF Si TP5000A-RF Si Code No. without receiver 087N791200 087N791300 Code No. for set c/w single channel receiver 087N791400 - Programmable 5/2 day operation · · Number of events per day 6, 4 or 2 Temperature range O , 5-30°C Clock display 24 hour 24 hour Factory pre-set programmes Yes Room temperature override Yes Adjustable Display time or temperature option Yes Thermostat mode & frost protection Yes Weekend into weekday override Yes Chrono-proportional or on/o control option Yes Power supply, thermostats 2 x AA/MN1500/LR6 alkaline batteries (1) Maximum ambient temperature 45°C Contact type and rating (hard-wired models) 10-230 Vac, 3(1)A Transmitter/receiver frequency (RF models) 433.92 MHz Transmitter range (RF models) 30 metres max. (2) Dimensions (mm) 110 wide x 88 high x 28 deep Notes: (1) Memory is retained for life of the product in non-volatile memory. (2) Please ensure there are no large metal objects between thermostat and receiver as these will interfere with radio signal. (3) Can be con gured by installer for remote temperature sensor, limit sensor, window contact or telephone activated switch contact. (4) Remote sensor is supplied as an acessory, if remote room sensor is required order TS2 sensor, code 087N681100 TP5000M Si 087N791700 · 24 hour Yes TP5000MA Si (3)(4) 087N791800 · 6, 4 or 2 O , 5-30°C 24 hour Yes Adjustable Yes Yes Yes Yes 230Vac, 50Hz 45°C 10-230 Vac, 3(1)A - - - - 110 wide x 88 high x 28 deep Receivers (RF models) Code No. Number of zones receiver covers Power supply (receivers) Contact details Contact rating Dimensions (mm) RX-1 087N747600 1 1-SPDT RX-2 RX-2C 087N747700 087N747900 2 2 230 Vac, ±15%, 50/60 Hz 1-SPDT, 1-SPST 2-SPDT 10-230 Vac, 3(1)A 138 wide x 88 high x 32 deep RX-3 087N747800 3 1-SPDT, 2-SPST TP5000 Si Range Fit Chrono Poroportional Controls and save costs If a property has a mechanical thermostat installed, then the energy-saving bene ts of a replacement high-e ciency condensing boiler will not be realised as the boiler will rarely be running in condensing mode. Switching to an on/o electronic room thermostat produces reductions of over 2% in both energy cost and carbon emissions. Use of an electronic thermostat with chronoproportional capability provides closer temperature control plus possible reductions of 10% in both fuel cost and carbon emissions (see g.1). These results are from tests using Danfoss controls. Tests carried out with other manufacturers' on/o controls produced similar gures. With a condensing gas boiler Chrono-6 also has the bene t of ensuring the boiler remains in condensing mode more often than might be achieved with a more basic on/o mode of operation. This occurs due to the faster reaction rate ensuring the returned water maintains the boiler in condensing mode over more of it's operating cycle, even at low heat loads. With slower reacting controls the water can cool in the system too much and hence require full circulation before the condensing cycle is functional and with a low load this might actually not occur, hence a condensing boiler might only give the performance on a non-condensing type when in low load with a slow control. Energy Savings In tests at Danfoss Randall we have observed energy savings of over 10% on a weekend pro le and over 6% on a week-day (2-heating period or "bi-modal") pro le when running a system with a chrono-proportional control rather than a mechanical thermostat. Conclusions Changing the boiler alone from non-condensing to condensing in a domestic central heating system will not necessarily optimise potential energy and carbon emission savings. An electronic room temperature control, preferably with chronoproportional capability, is often needed to make the cost of replacing the boiler worthwhile. Source: Danfoss Randall Ltd. test laboratory 2007 Figure 1 Control Mechanical On/Off Electronic On/Off Chrono- Proportional Energy Cost (£) 2.39 2.34 2.14 Energy Saving (%) 2.10 10.35 Carbon Emissions (kg CO") 13.56 13.25 12.11 Carbon Saving (%) 2.31 10.71 Wiring Details 123 TP5000 Si 123 Electronics B N N C S1 S2 L DD L Remote Input (TP5000MA Si only) TP5000M Si ELECTRONICS NL 1234 COM ZONE ZONE 1 ON 1 OFF RX1 ELECTRONICS AB C 1 2 3 4 5 6 N L COM COM ZONE 1 ZONE 1 ZONE 2 ZONE 2 ZONE 1 ZONE 2 ON OFF ON OFF RX2-C ELECTRONICS TERMINAL 6 RX3 ONLY ABC 123 4 5 6 N L COM ZONE ZONE ZONE ZONE 1 ON 1 OFF 2 ON 3 ON RX2 and RX3 Literature Service Product Range Product Selection Guide Wireless Control Packs Under oor Heating Product & System Guide RA2000 Commercial Radiator Thermostats Radiator Thermostats RAS-C2 Revolver Radiator Thermostats, incl. push- t versions RAS-D2 Domestic Revolver Radiator Thermostats, incl. push- t versions RA2000 Commercial Radiator Sensors RA Plus Programmable Radiator Thermostats RA-FN, RA-G Commercial Valve Bodies RA-N Commercial Valve Bodies RLV-D Domestic Lockshield Valves, including push- t versions RLV Commercial Lockshield Valves H Pieces & Sensors Bathroom Solutions - RA-URX Towel Rail Bathroom Solutions - RA-URX Towel Rail Replacement Sensors RA-V & RA-VL Time Controls Time Controls - TS715 Si, CP715 Si & FP715 Si Time Controls, Compatibility Guide TS975 & FP975 Replacement Time Controls GP Time Controls - 102, 102E5, 102E7, 103, 103E5 & 103E7 Set Range - SET1E, SET2E, SET3E & SET3M Programmers - 3020P, 3060 & 4033 Commercial Time Controls Electric Thermostats TP4000 Programmable Room Thermostat TP5000 Si including RF versions TP7000 Programmable Room Thermostats HC6000 Heat/Cool Thermostats TP9 Programmable Thermostat with Hot Water Time Control Programmable Hot Water Thermostat - WP75RF RMT/RET Room Thermostats RET Electronic Room Thermostats with Function Switches RET230 HC & HCW Heat/Cool Thermostats Battery Room Thermostats RET B plus RF versions RET-MD & RET-M Room Thermostats Cylinder, Pipe & Frost Thermsotats - ATC, ATP, ATF & RET230F Immersion Thermostats - ITC, ITL & ITD Under oor Heating Controls Under oor Heating Product & System Guide Electric Under oor Heating Mat FH-WC Hard Wired Zone Control FH-BU Wireless Zone Control FHV Valves for Under oor Heating Thermal Actuators TWA Motorised Valves & Other Controls Control Packs Wiring Centre WC4B Wireless Controls Packs WP75-RF H Series Motorised Valves Domestic Bypass Valves AVDO Domestic Bypass Valves ARV22 Thermal Actuators TWA AB-QM Balancing Valves AB-QM Balancing Valves Thermostatic Cylinder Controls RAVI Climate Control Range - FEK, FEV & FED Type Catalogue Catalogue Catalogue Catalogue Sales Lea et* Sales Lea et* Datasheet Datasheet Datasheet Datasheet Datasheet Datasheet Datasheet Sales Lea et Datasheet Datasheet Sales Lea et Sales Lea et Datasheet Sales Lea et Sales Lea et Datasheet Sales Lea et Sales Lea et Sales Lea et* Sales Lea et* Sales Lea et* Datasheet Sales Lea et* Sales Lea et* Sales Lea et* Datasheet Sales Lea et* Sales Lea et* Datasheet Datasheet Catalogue Sales Lea et* Datasheet Datasheet Sales Lea et* Datasheet Sales Lea et* Instructions Datasheet Sales Lea et* Datasheet Datasheet Datasheet Datasheet Sales Lea et Datasheet Catalogue Part No. 028 662 438 410 250 336 VDVBE122 VD53P102 VD51Q102 VD51G802 VD35E202 VD35D102 VD35C102 580 VD31B102 VDULY102 334 196 208 582 188 040 606 238 296 594 596 318 282 584 592 660 588 590 374 374 438 628 620 622 476 VDSAP112 120 39917 408 192 062 380 VDSAP112 VDA2W112 VBA2Z102 240 346 Quantity Ordering Literature To obtain copies of individual product sales lea ets and datasheets please photocopy this page and complete your personal details and the literature quantities you require and fax this form to UK 0845 1217 515 Ireland 1800 930 242 Company Name: Address Postcode Contact Name Datasheets * Denotes that datasheets are also available. Please use the space below to indicate which datasheet you would like to order. Datasheet Quantity Danfoss Ltd Ampthill Road, Bedford, MK42 9ER, Tel: 01234 364621, Email: ukheating@danfoss.com, Web: www.heating.danfoss.co.uk VB.RM.C4.02_Sep2014 Part No: 296v04 09/14Adobe PDF Library 10.0.1; modified using iTextSharp™ 5.5.10 ©2000-2016 iText Group NV ( ; licensed version) ( ; licensed version)