User Manual

Portable Air Conditioner

Model No.: NPL6-05C/X1E

Item No.: A5413-8K-WAL-AU

Read all instructions carefully before setting up and operating the unit. Keep this manual for future reference.

Contents

Air Conditioner Safety

Your safety and the safety of others are very important. We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety messages.

Safety Alert Symbol: This symbol alerts you to potential hazards that can kill or hurt you and others. All safety messages will follow the safety alert symbol and either the word "DANGER," "WARNING" or "CAUTION." These words mean:

All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can happen if the instructions are not followed.

Important Safety Instructions

WARNING: To reduce the risk of fire, electrical shock, injury to persons, or damage when using the air conditioner, follow basic precautions, including the following:

NOTE: Turning off power by pressing the Power button does NOT disconnect the appliance from the power supply.

READ AND SAVE THESE INSTRUCTIONS

AVERTISSEMENT: Pour réduire le risque d'incendie, de choc électrique, de blessure ou de dommage lors de l'utilisation du climatiseur, suivez les précautions de base, notamment les suivantes:

REMARQUE: couper l'alimentation en appuyant sur le bouton d'alimentation ne déconnecte PAS l'appareil de l'alimentation électrique.

Parts and Features

Gather the required tools and parts before starting installation.

Tools Needed

Location Requirements

Place the air conditioner on a flat, level surface in a location that is at least 50cm from any wall.

NOTE: A minimum clearance of 50cm from the air conditioner to the wall must be maintained to ensure proper airflow.

Electrical Requirements

! WARNING

Electrical Shock Hazard

Power Supply Cord

Wiring Requirements

NOTE: Do not operate any other electrical appliances on this circuit or you may trip the circuit breaker/fuse. If this power supply cord is damaged, it cannot be repaired. It must be replaced with a cord from the product manufacturer. If the power supply cord is damaged contact Customer Service.

To test the power supply cord before operation:

  1. Plug the power cord into a grounded 3 prong outlet.
  2. Press the Test button, and then press and release the Reset button to restore power.

Required Grounding Method

This air conditioner must be grounded. The air conditioner is equipped with a power supply cord that has a 3-prong grounding plug. The power supply cord must be plugged into a mating, grounded 3 prong outlet, and grounded in accordance with all local codes and ordinances.

Installation Instructions

STEP 1 - UNPACK AIR CONDITIONER

! WARNING

Excessive Weight Hazard

Use two or more people to move and install air conditioner. Failure to do so can result in back or other injury.

STEP 2 - TWIST THE EXHAUST HOSE CONNECTOR ONTO EXHAUST HOSE

STEP 3 - CONNECT EXHAUST HOSE TO THE AIR CONDITIONER

IMPORTANT: When connecting the hose, the air conditioner must be close enough to the window that you will not dislodge the window seal plate. Once the hose is connected, move the air conditioner 20" (51 cm) from the wall.

STEP 4 - INSTALL WINDOW PANELS

Depending on the size of your window opening, use the main panel and one or both of the extension panels.

Vertical Slide Window

Horizontal Slide Window

STEP 5 - COMPLETE INSTALLATION

Close the window as far as the window slide set, so this covers the window opening completely. Place the device at least 50 cm away from walls and other objects.

NOTE:

! WARNING

Electrical Shock Hazard

  1. Plug the power cord into a grounded 3-prong outlet.
  2. Press the Reset button on the power cord to ensure the safety plug is providing power to the air conditioner.

Control Panel

BUTTONS

A. TIMER BUTTON

Program a time from (1-hour to 24-hours) for the air conditioner to turn Off or On. When a Time Delay is programmed, the Timer indicator light will illuminate.

While the air conditioner is operating:

  1. Press the Timer button.
  2. Press the Up/Down arrow buttons to select the number of hours you want the air conditioner to continue to operate before turning Off.

While the air conditioner is off:

  1. Press the Timer button.
  2. Press the Up/Down arrow buttons to select the number of hours you want the air conditioner to remain off before turning On.

NOTE: Wait approximately 5 seconds for the Turn-On time to be saved.

To cancel the timer:

B. FAN SPEED BUTTON

The fan speed can be adjusted from Low speed to High speed when the air conditioner is in operation.

NOTE: The fan speed cannot be adjusted when the unit is in Dehum mode.

C. UP AND DOWN ARROW BUTTONS

Adjusts the Temperature or Hours in Time Delay.

To Set the Temperature:

The temperature can be set between 62°F and 86° F (17°C and 30° C) when the air conditioner is in Cool mode.

  1. Press the Mode button until the Cool mode is selected.
  2. Press the Up Arrow or Down Arrow buttons to select the Temperature.

NOTE: The temperature cannot be set when the air conditioner is in either Fan or Dehum mode.

NOTE: The Up Arrow and Down Arrow buttons, when pressed at the same time, allow you to select between displaying the temperature in °C or °F.

D. CONTROL PANEL DISPLAY

Displays the Set Temperature in degrees Fahrenheit or degrees Celsius, or the hours remaining in a Time Delay.

E. MODE BUTTON

Press the Mode button to toggle among the operating options. The corresponding indicator will illuminate:

F. POWER BUTTON

Turns ON/OFF power to the air conditioner.

NOTE: Turning off power by pressing the Power button does NOT disconnect the appliance from the power supply.

G. SLEEP MODE BUTTONS

The Timer and Down Arrow buttons, when pressed at the same time, allow you to select Sleep mode.

Remote Control

  1. Power On and Off - When the unit is plugged in, press the POWER button to turn on the unit. Press the POWER button once more to turn the unit off.
  2. Press the Cool, Dehum, Fan button to select working mode.
  3. Fan Speed - Press the Speed button to adjust the fan speed. When the unit is in Dehum mode, the fan speed cannot be changed.
  4. Temperature Setting - When the unit is in cool mode, you can select your desired temperature. Press the or to select your desired temperature setting.
  5. SLEEP MODE - When in air conditioning mode, press the SLEEP Button on the remote control.
  6. TIMER
    • Auto-On: Press the TIMER button when the unit is off to set up the Auto-on timer. Press the or to set timer within 1-24 hours.
    • Auto-Off: Press the TIMER button when the unit is On to set up the Auto-off timer. Press the or to set timer within 1-24 hours. To cancel the timer, press the TIMER button until the timer mode is turned off.

NOTE:

WARNING

Safety Protections

  1. Water-full safety alarm and shut – off protection function
    When the water volume exceeds its alarm level in chassis, warning sounds automatically and water-full icon is lighting in display, you need to drain the water and re-start the unit. (For more information about how to drain, refer to the "Drainage Instruction" please). If the unit is not shut down manually, the unit will recover to the original operating status automatically once the water is fully drained. Or connect the power to re-start the unit again.
  2. Anti-frozen protection function
    When the ambient temperature ≤22℃/72F, and the compressor runs continuously for 30 minutes, the compressor is turned off. The fan is forced to run at high speed, while the fan speed indicator on the display panel can be switched. The unit is forced to run under above status for 6 minutes. After that, the unit will return to its original settings.
  3. Delay protection function of compressor
    This unit offers restart protection to compressor. Except that the compressor may start immediately when the unit is energized first time, there is 3-minute delay re-start protection after compressor is shut down.
  4. Coil and room temperature sensor failure:
    1. Detect sensor failure at the beginning of power-on or power-on state
    2. When a sensor failure is detected at the beginning of power-on, it will immediately enter the failure state. If it returns to normal at this time, it will enter the standby state;

Air Conditioner Use

IMPORTANT: If the air conditioner has been tilted on its side, wait 24 hours before turning on the air conditioner to allow the oil to return to the compressor. This will prevent the air conditioner from failing prematurely.

Hold handles on side panels to move the unit in upright position.

NOTE:

Drain the Internal Water

You will need a small pan to catch the water coming out of the water tank. Once the water tank is empty, the unit will resume operation within a few minutes.

Manual Drainage

  1. Once the unit shuts down upon water-full, turn off the unit and then unplug.
  2. Put the tray below the water outlet at the back of the unit.
  3. Screw off the drain cover, unplug the water stopper for water flow into the tray.
  4. Plug in stopper and screw the drain cover tightly onto water outlet after drainage.

Notes:

Continuous Drainage

  1. Screw off the drain-cover & unplug the water stopper.
  2. Connect drain-hole with $13mm drain hose, as deep as possible to avoid leakage.
  3. Pull the drain hose to bathroom or outdoors.

Notes:

Care and Maintenance

WARNING

Be sure to turn off the unit and pull out the plug before maintenance or sending it to service center.

Surface Cleaning

Filter Cleaning

Notes:

Internal Water Tank

The Water Full indicator illuminates, when the internal water has filled with condensate water.

To Empty the Internal Water Tank:

  1. Unplug or disconnect power.
  2. Place a shallow 1 quart or larger pan (not included) below the lower drain located on the back (near the bottom) of the air conditioner.
  3. Remove the cap and the rubber plug and drain the water tank.
  4. Re-insert the drain plug and screw the cap snugly into place.
  5. Plug in or reconnect power.

Storage

Please store the air conditioner properly if not in use.

  1. Screw off the drain cover and pull out the stopper to drain condensate water completely. Or tilt the unit to drain water.
  2. Keep unit running in fan mode for half day to dry inside of unit completely to prevent from going moldy.
  3. Turn off the unit, pull out plug then wrap the power cord around the wire-winding pillar, insert the plug into the universal fixing hole at the back panel of the unit, install the water stopper and drain cover.
  4. Remove the heat exhaust hose to assembly, clean and keep it properly.
  5. Take out the batteries from remote controller and place it in the remote control box.

Note: Assure the unit is stored in a dry place. All accessories of the unit shall be protected together properly. Keep the unit away from children.

Troubleshooting

First try the solutions suggested here to possibly avoid the cost of a service call.

Trouble Cause Solution
The unit fails to start up Power supply failure Connect the unit to a live socket and turn it on.
Water-full and its icon lighting Drain the water stored in the unit.
Ambient temperature too low or low high It is recommended to use this unit between 41-95°F (5-35℃).
Bad cooling or heating effects The room temperature is lower than the set temperature in cooling mode or higher temperature in heating mode Change the set temperature
There is direct sunlight Close the window curtain
The doors and windows are open, the room is crowded or there are other heat sources Close the door and window, remove other heat sources, and add new air-conditioners
High noise level Dirty filter Clean or replace the filter mesh
Air inlet or air outlet clogged Remove the obstruction
The compressor does not work The unit is being placed at uneven surface. Put the unit at a flat and firm place (may reduce noise)
Initiation of overheating protection Wait for 3 minutes until the temperature decrease, the unit will re-start automatically
The remote control does not work Too long distance Bring the remote control close to the Air conditioner and ensure airs at signal receptor on unit.
The remote control didn't aim at signal receptor on unit. Replace the batteries
The batteries have no electricity Contact customer service & repair center
"E1" code displays Room temperature sensor failure Contact customer service & repair center
"E2" code displays Tube temperature sensor failure Drain the condensate and re-start the unit
Water full displays Water tank in chassis is full

Note: Do not dismantle or repair the unit without authorization, improper repair will void the warranty card and cause harm to you and your property.

Disposal

All the technical and specific parameters, please refer to product nameplate.

Due to continuous improvement, we reserve the right to change some design without timely notices.

Electrical products should be properly disposed.

Please recycle where facilities exist.

Check with your local authority or retailer for recycling.

Packing List

No. Description Quantity
1 User Manual 1
2 Remote Control 1
3 Battery 2
4 Connector 1
5 Exhaust Hose 1
6 Adapter 1
7 Window kits 1
8 Window kits screw 1
9 Flat screws 2

Contact Information

Thank you for purchasing this product! If you have any questions about the product, such as missing parts, damaged products, product assembling, and operation, please contact us via Amazon Message or customer service number: 213-4467172 or 661-4358826

IMPORTANT

Please call our customer service department for any consulting:

213-4467172
661-4358826
(8:30am - 5:30pm P.S.T.)

DATED PROOF OF PURCHASE IS REQUIRED FOR WARRANTY SERVICE.

AVIS

Veuillez appeler le service à la clientèle pour toutes questions au:

213-4467172
661-4358826
(8:30am - 5:30pm P.S.T.)

PREUVE D'ACHAT ORIGINALE REQUISE POUR SERVICE DE GARANTIE.

IMPORTANTE

Sólo hay que llamar nuestro departamento de servicio al cliente en caso de tener preguntas o inquietudes:

213-4467172
661-4358826
(8:30am - 5:30pm P.S.T.)

SE REQUIERE PRUEBA DE COMPRA CON FECHA PARA SERVICIO BAJO GARANTÍA.

Address: ROWAN ELECTRIC APPLIANCE LLC
28407 Ascent Way, Santa Clarita, CA 91350
Phone: 213-4467172 or 661-4358826

Models: NPL6-05C-X1E, A5413-8K-WAL-AU, NPL6-05C-X1E Portable Air Conditioner, NPL6-05C-X1E, Portable Air Conditioner, Air Conditioner, Conditioner

File Info : application/pdf, 23 Pages, 6.11MB

PDF preview unavailable. Download the PDF instead.

67931960

Related Documents

Preview User Manual for Portable Air Conditioner NPLH5A-05C/X1E
This user manual provides comprehensive instructions for the setup, operation, care, and troubleshooting of the NPLH5A-05C/X1E Portable Air Conditioner. It includes safety precautions, parts identification, installation steps, control panel and remote control functions, safety protections, and maintenance guidelines.
Preview User Manual: Portable Air Conditioner A5410CE / NPH-10C/X1E
Comprehensive user manual for the A5410CE / NPH-10C/X1E Portable Air Conditioner. Provides detailed guidance on safety, installation, operation, control panel functions, remote control usage, maintenance, troubleshooting, and warranty information.
Preview Portable Air Conditioner User Manual - Models A5405-8K, A5405-10K
Comprehensive user manual for the portable air conditioner, covering safety instructions, installation, operation, maintenance, troubleshooting, and warranty information for models A5405-8K and A5405-10K.
Preview Dehumidifier Operation Instruction Manual - Model FDD22-5310V1R3
This document provides operation instructions, safety precautions, and maintenance guidelines for the Dehumidifier, Model FDD22-5310V1R3. Learn about its functions, proper usage, and troubleshooting.
Preview Portable Air Conditioner Owner's Manual - Model A4210-10K
Comprehensive owner's manual for the Portable Air Conditioner, Item No. A4210-10K, Model OL-BA010L-06CD/K. This guide provides essential information on installation, operation, safety precautions, maintenance, troubleshooting, and decommissioning for the R32 refrigerant unit.
Preview Rowan Electric Window Air Conditioner Manual: Installation, Operation, and Safety
Comprehensive user manual for Rowan Electric Appliance LLC window air conditioners. Includes detailed installation instructions, operating modes, safety precautions, care and cleaning guidelines, and troubleshooting tips for models A8502W, A8510W, A8512W, A8514W.
Preview Portable Air Conditioner Owner's Manual - Model OL-BA012C-08CD/C
Owner's manual for the portable air conditioner, model OL-BA012C-08CD/C. Provides detailed information on product description, safety precautions, installation, operation, cleaning, troubleshooting, and decommissioning.
Preview ROWAN ELECTRIC APPLIANCE LLC Portable Air Conditioner Owner's Manual - OL-BA015B-09CD/B
This owner's manual provides comprehensive instructions for the ROWAN ELECTRIC APPLIANCE LLC Portable Air Conditioner, model OL-BA015B-09CD/B. It covers installation, operation, safety precautions, cleaning, and troubleshooting for this R32 refrigerant unit, designed for efficient cooling, ventilation, and dehumidification in single rooms.