Installation Guide for Altronix models including: eBridge8PCRM, 8 Port Ethernet Over Caox Receiver, Ethernet Over Caox Receiver, Over Caox Receiver, Caox Receiver, eBridge8PCRM, Receiver

IIeBridge8 16PCRM G19U

Click to View

Altronix EBRIDGE8PCRM | EoC 8 Port Receiver, 25Mbps per port


File Info : application/pdf, 8 Pages, 1.08MB

PDF preview unavailable. Download the PDF instead.

EBRIDGE8 16PCRM
PLUS

eBridgePCRM Series
IP and PoE+ over Coax Solution
Models Include:
eBridge8PCRM
- Eight (8) Channel Receiver
eBridge16PCRM
- Sixteen (16) Channel Receiver
Installation Guide

Z1409

I.T.E. 43KC

Rev. 072412

More than just power.TM

Installing Company: _______________ Service Rep. Name: __________________________________

Address: _____________________________________________ Phone #: __________________

Overview:
Altronix eBridge8PCRM/16PCRM and eBridge1PCTX or eBridge1ST are CAT5 to Coax cable Ethernet adapters/ Media converters that deliver data and power over the coax cable in a PoE+ compliant format. The paired set enables fast 10/100Base-T Ethernet digital communication to be transmitted over Coax cable. eBridge8PCRM/16PCRM receiver is powered by a UL Listed limited power source, PoE midspan or endspan product, such as a NetWay8M and NetWay16M, and sends its power over the coax to the eBridge1PCTX or eBridge1ST transmitter under PoE protocol. This enables the eBridge8PCRM/16PCRM to be used in a managed manner, allowing for remote camera reset. The eBridge1PCTX or eBridge1ST, in turn, delivers that PoE+ compliant power to a PoE enabled camera or IP device. The eBridge8PCRM/16PCRM will not deliver power to non-compliant devices, thus avoiding damage to improperly connected analog cameras. These plug and play units facilitate system upgrades from analog to IP cameras/devices utilizing existing legacy Coax and eliminating the costs and labor associated with installing new network cabling. In addition, data transmission and power over the Coax is possible up to 500m in comparison to 100m Ethernet maximum distance (see Maximum Length of Coax Type vs. Camera Power/PoE Class, pg. 6). A maximum range from head end to the PoE camera/device is 700m taking into consideration that up to 100m of structured cable may be deployed at each end.

Features:

Agency Listings:

LED Indicators (cont'd):

· UL 60950-1 Information Technology Equipment. · eBridge1PCTX and eBridge1ST:

· CE

European Conformity.

Blue LED - Coax link connection.

· C-Tick C-Tick compliant.

Green LED - PoE from eBridge8PCRM/16PCRM.

Compatible Transceivers:

Environmental:

· eBridge1PCTX: PoE/PoE+ compliant transceiver. · Operating Temperature:

· eBridge1ST: PoE/PoE+ compliant mini transceiver. eBridge8PCRM/16PCRM:

Input: · Powered by a UL Listed limited power source,
PoE midspan or endspan.
Ethernet: · Connectivity: RJ45, auto-crossover. · Wire type: 4-pair CAT5 or better structured cable. · Distance: up to 100m. · Speed: 10/100BaseT, half/full duplex,
auto negotiation. PoE compliant to IEEE 802.3af (15W) and PoE+ compliant to IEEE 802.3at (30W) delivered to camera by eBridge1PCTX or eBridge1ST. Power provided by eBridge8PCRM/16PCRM to

­ 20ºC to 49ºC (­ 4ºF to 120.2ºF). eBridge1PCTX:
For 15W: ­ 40ºC to 75ºC (­ 40ºF to 167ºF). For 30W: ­ 40ºC to 49ºC (­ 40ºF to 120.2ºF). eBridge1ST: For 15W: ­ 40ºC to 75ºC (­ 40ºF to 167ºF). For 30W: ­ 40ºC to 65ºC (­ 40ºF to 149ºF). · Storage Temperature: ­ 30ºC to 70ºC (­ 22ºF to 158ºF). · Humidity: 20 to 85%, non-condensing.
Functions: · Auto detection and protection of legacy
non-PoE cameras/devices.

eBridge1PCTX or eBridge1ST by PoE protocol.

Applications:

· Throughput is rated to pass 25Mbps of data at

· Retrofit digital IP cameras in an analog

distances up to 500m. With proper headend

CCTV installation.

equipment this supports Megapixel, HD720, HD1080. · Works with Megapixel, HD720, HD1080 and

Coax: · Distance: up to 500m (see Maximum Length of
Coax Type vs. Camera Power/PoE Class, pg. 6) for power delivery of coax. · Connectivity: BNC, RG-59/U or similar.
LED Indicators: · eBridge8PCRM/16PCRM:
Blue LED - Coax link connection. Green - PoE ON. Green - Power ON. · eBridge8PCRM/16PCRM, eBridge1PCTX, eBridge1ST: Yellow and Green LED (RJ45) IP Link status, 10/100Base-T/active.

VGA (SD) cameras (see note, pg. 3). · Extend Network link distance in an industrial
environment over 610m (see note, pg. 3). · Upgrade deployed CCTV Coax to a digital network
in Retail, Hospitality, Arenas, Casinos, Airports, Schools, Hospitals, Transportation, etc.
Mechanical: · Dimensions (H x W x D approx.):
eBridge8PCRM/16PCRM dimensions: 1.625" x 19.125" x 8.5" (42mm x 486mm x 216mm) eBridge1PCTX dimensions: 1" x 2.5" x 4.375" (25.4mm x 63.5mm x 111.1mm). eBridge1ST dimensions: 2.27" x 2.645" x 1.12" (57.7mm x 67.2mm x 28.4mm).

- 2 -

eBridge8PCRM/16PCRM Installation Guide

Installation Instructions:
Wiring methods shall be in accordance with the National Electrical Code/NFPA 70/ANSI, and with all local codes and authorities having jurisdiction. Wiring should be UL Listed and/or Recognized wire suitable for the application. eBridge8PCRM/16PCRM is not intended to be connected to outside plant leads and should be installed indoors within the protected premises. The eBridge8PCRM/16PCRM and eBridge1PCTX are intended for indoor use only. Elevated Operating Ambient - If installed in a closed or multi-unit rack assembly, the operating ambient temperature of the rack environment may be greater than room ambient. Therefore, consideration should be given to installing the equipment in an environment compatible with the maximum ambient temperature (Tma) specified by the manufacturer. Reduced Air Flow - Installation of the equipment in a rack should be such that the amount of air flow required for safe operation of the equipment is not compromised. Do not obstruct any air vents on the unit. It is recommended to leave half space above and below the unit. Mechanical Loading - Mounting of the equipment in the rack should be such that a hazardous condition is not achieved due to uneven mechanical loading. Circuit Overloading - Consideration should be given to the connection of the equipment to supply circuit and the effect that overloading of the circuits might have on overcurrent protection and supply wiring. Appropriate consideration of equipment nameplate rating should be used when addressing this concern. Reliable Earthing - Reliable earthing of rack-mounted equipment should be maintained. Particular attention should be given to supply connections other than direct connections to the branch circuit (e.g. use of power strips). 1. eBridge8PCRM/16PCRM installation:
a. Attach mounting brackets to eBridge8PCRM/16PCRM unit for rack installation (Fig. 4, pg. 8). Affix rubber pads to eBridge8PCRM/16PCRM for shelf installation (Fig. 6, pg. 8). Unit should be located in proximity to ethernet switch/network, NVR or video server.
b.Connect structured cable from ethernet midspan or endspan device to RJ45 jack marked [10/100BaseT] (Fig. 2, pg. 5).
c. Connect Coax cable to BNC connector marked [Coax] (Fig. 1, pg. 4). 2. eBridge1PCTX installation:
a. Secure unit to desired mounting surface with a proper fastening device utilizing the case's mounting hole. Unit should be mounted in proximity of camera/device.
b.Connect structured cable from IP camera/device to RJ45 jack marked [10/100BaseT] (Fig. 2, pg. 5). c. Connect Coax cable to BNC connector marked [Coax] (Fig. 2, pg. 5). 3. eBridge1ST installation: a. Secure unit to the desired mounting surface with a proper fastening device utilizing the case's mounting
hole (Fig. 3, pg. 6). Unit should be mounted in proximity of camera/device. b.Connect structured cable from IP camera/device to RJ45 jack marked [PoE Out] (Fig. 2a, pg. 5). c. Connect Coax cable from eBridge8PCRM/16PCRM to BNC tether cable marked [Coax] (Fig. 2a, pg. 5).
Note: eBridge8PCRM/16PCRM is designed to accommodate Megapixel, HD720, HD1080 and VGA (SD) cameras. It is important to note that some high resolution and high frame rate cameras may demand faster headend processing ability, such as a PC graphics card to present a quality image. If the headend processing equipment is insufficient in speed, the image may show pixelation and latency. It is advisable to pretest system if unsure. Alternatively, frame rate and resolution may be reduced to accommodate system equipment.

eBridge8PCRM/16PCRM Installation Guide

- 3 -

- 4 -

Fig. 1 eBridge8PCRM (rear)

eBridge8PCRM

Coax Cable from eBridge1PCT or eBridge1PCTX

Data In

8

7

6

5

Data In

4

3

2

1

1

2

3

4

eBridge8PCRM (front)

10/100 Base-T

5

6

7

8

10/100 Base-T

Structured Cable from midspan/endspan

Fig. 1a Coax Cable from eBridge1PCT or eBridge1PCTX

eBridge16PCRM

Data In

16

15

14

13

eBridge16PCRM (rear)

Data In

12

11

10

9

Data In

8

7

6

5

Data In

4

3

2

1

eBridge8PCRM/16PCRM Installation Guide

1

2

3

4

eBridge16PCRM (front)

10/100 Base-T

5

6

7

8

10/100 Base-T

Structured Cable from midspan/endspan

9

10

11

12

10/100 Base-T

13

14

15

16

Fig. 2 Fig. 2a

eBridge1PCTX
Structured Cable from IP Camera/Device Coax Cable from eBridge8PCRM/16PCRM
eBridge1ST Front

Green LED indicates
Power
Blue LED indicates Coax Connection
Rear

Green LED indicates PoE Out to Device

Structured Cable from Camera/Device

Flying BNC Connector

Blue LED indicates Coax Link is active

Flying BNC Connector

Parameter Connections Input Power Requirements Indicators
Environmental Conditions
Regulatory Compliance Weights (approx.)

Technical Specifications:

Description

BNC for Coax link. RJ45 for ethernet link.

Midspan or endspan port connected.

Blue: Yellow (RJ45 connector): Green (RJ45 connector): Green:

Coax Link. On - Link, Off - No Link, Blinking - Activity. On - 100Base-TX, Off - 10Base-T. Power.

Operating Ambient Temperature (UL60950-1):

eBridge8PCRM/16PCRM: ­20ºC to 49ºC (­4ºF to 120.2ºF).

eBridge1PCTX: For 15W: ­40ºC to 75ºC (­40ºF to 167ºF).

For 30W: ­40ºC to 49ºC (­40ºF to 120.2ºF).

eBridge1ST: For 15W: ­40ºC to 75ºC (­40ºF to 167ºF).

For 30W: ­40ºC to 65ºC (­40ºF to 149ºF).

Storage Temperature:

­30ºC to 70ºC (­22ºF to 158ºF).

Relative humidity: 20 to 85%, non-condensing.

Operating Altitude: ­304.8 to 2,000m.

UL/cUL Listed for Information Technology Equipment (UL 60950-1). CE European Conformity. C-Tick compliant.

eBridge8PCRM: Product: 5.8 lb. (2.63 kg) | Shipping: 7.8 lb. (3.54 kg) eBridge16PCRM: Product: 7.2 lb. (3.27 kg) | Shipping: 9.2 lb. (4.17 kg)

eBridge8PCRM/16PCRM Installation Guide

- 5 -

Multiple PoE Camera Connection:
eBridge8PCRM shown. eBridge16PCRM is similar, with twice as many channels. Fig. 3

eBridge8PCRM
Powered Switch or NetWay MidSpan

PoC (PoE+ over Coax) 500m max.
PoC (PoE+ over Coax) 500m max.
PoC (PoE+ over Coax) 500m max.
PoC (PoE+ over Coax) 500m max.

Transceiver PoE compliant 100m max.

PoE Camera

Transceiver PoE compliant 100m max.

PoE Camera

Transceiver PoE compliant 100m) max.

PoE Camera

PoE compliant Transceiver 100m max.

PoE Camera

PoC (PoE+ over Coax) 500m max.
PoC (PoE+ over Coax) 500m max.
PoC (PoE+ over Coax) 500m max.
PoC (PoE+ over Coax) 500m max.

Transceiver PoE compliant 100m max.

PoE Camera

Transceiver PoE compliant 100m max.

PoE Camera

Transceiver PoE compliant 100m max.

PoE Camera

PoE compliant Transceiver 100m max.

PoE Camera

eBridge1PCTX or
eBridge1ST

Legend: Coax Structured Cable

100m max. 100m max. 100m max. 100m max. 100m max. 100m max. 100m max. 100m max.

Maximum Length of Coax Type vs. Camera Power/PoE Class:

Camera Power/ PoE Class
13W/0 4W/1 6.5W/2 13W/3 19W 25W

RG59/U (23AWG)
261 500 500 261 153 119

RG59/U (22AWG)
336 500 500 336 199 152

RG59/U (20AWG)
Max. Length (meters) 500 500 500 500 316 240

RG59/U (18AWG)
500 500 500 500 500 366

RG6/U (18AWG)
500 500 500 500 500 366

- 6 -

eBridge8PCRM/16PCRM Installation Guide

eBridge8PCRM/16PCRM Installation Guide

Enclosure Dimensions (H x W x D approximate):
1.625" x 19.125" x 8.5" (42mm x 486mm x 216mm) eBridge16PCRM shown. eBridge8PCRM is similar.

10/100 Base-T

1

2

3

4

0.75" (19.05mm)

10/100 Base-T

5

6

7

8

10/100 Base-T

9

10

11

12

19.125" (486mm)

17.625" (447.7mm)

10/100 Base-T

13

14

15

16

8.5" (216mm)

1.625" (42mm)

Data In

16

15

14

13

Data In

12

11

10

9

Data In

8

7

6

5

Data In

4

3

2

1

- 7 -

Mounting Options: Rack Mount Installation
1. Remove and discard factory installed screws from both sides of rack chassis (Fig. 4a). 2. Install mounting brackets (A) on the left and right side of rack chassis using the four (4) flat head screws (B)
(included) (Fig. 4b). 3. Place unit into desired EIA 19" rack position and secure with mounting screws (not included) (Fig. 4c).

Fig. 4

Fig. 4a

Fig. 4b

Fig. 4c

Top
Front Left

Top Front Left
B

Top Front Left

Remove

A

Wall Mount Installation
1. Install mounting brackets (A) on the left and right side of rack chassis using four (4) flat head screws (B) (included) (Fig. 5a).
2. Place unit at desired location and secure with #6 size screws or larger (not included) (Fig. 5b). Caution: It is necessary to make sure mounting screws are securely fastened to a beam when installing the unit vertically.

Fig. 5 Fig. 5a

Fig. 5b

B

A

Shelf Installation

Dotted lines indicate studs behind sheetrock.

1- Position and affix rubber pads (C) (included) at each corner on the bottom of the unit (Fig. 6).

2- Place unit in desired location.

Fig. 6

Mounting Hardware (Included):

Left Side

A Two (2) mounting brackets

C
Rubber
Pad

B Six (6) flat head screws for mounting brackets.
C Four (4) rubber pads.

Altronix is not responsible for any typographical errors. ­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­ 140 58th Street, Brooklyn, New York 11220 USA | 718-567-8181 | fax: 718-567-9056

website: www.altronix.com | e-mail: info@altronix.com | Lifetime Warranty

IIeBridge8PCRM/16PCRM

G19U

MEMBER

- 8 -

eBridge8PCRM/16PCRM Installation Guide



References

Adobe PDF Library 16.0 Adobe InDesign 16.4 (Macintosh)