Single-Zone Systems

Standard Highwall

Key Features:

  • Up to 23 SEER2; 9.5 HSPF2
  • 09/12K 115V options with basepan heater
  • 09/12/18/24K 230V options with highwall matches

OPERATING RANGE (°F):

Cooling: -40 to 75°F; Heating: -31 to 75°F (Cooling below 23°F requires wind baffle).

Size Outdoor Model Indoor Model AHRI# Max Heat @ 5°F SEER2/EER2/HSPF2 (IV) Lineset: Liquid Suction Min/Max Line Length Max Fuse Size A Min Circuit Amp
9K (115V) 1Q09TE1BEA QS09WB1BEA 215564827 7,000 20/12/9.5 1/4" - 3/8" 10'/66' 25 18
12K (115V) 1Q12TE1BEA QS12WB1BEA 215564828 9,000 20/12/9.5 1/4" - 3/8" 10'/66' 25 18
9K (230V) 1Q09TE2BEA QS09WB2BEA 217124721 8,000 23/12/9.5 1/4" - 3/8" 10'/66' 10 9
12K (230V) 1Q12TE2BEA QS12WB2BEA 217124722 10,400 21/12/9.5 1/4" - 3/8" 10'/66' 10 9
18K (230V) 1Q18TE2BEA QS18WB2BEA 217124723 15,200 20/12/9.5 1/4" - 1/2" 10'/83' 20 15
24K (230V) 1Q24TE2BEA QS24WB2BEA 217124724 19,200 18/12/9.5 1/4" - 1/2" 10'/165' 30 20

Cassette

Key Features:

  • Up to 23 SEER2; 9.5 HSPF2
  • Low ambient heating down to -15°F (built-in basepan heater)
  • -40°F low ambient cooling with wind baffle & top cover (sold separately)

OPERATING RANGE (°F):

Cooling: -40 to 75°F; Heating: -31 to 75°F (Cooling below 23°F requires wind baffle).

Size Outdoor Model Indoor Model AHRI# Max Heat @ 5°F SEER2/EER2/HSPF2 (IV) Lineset: Liquid Suction Min/Max Line Length Max Fuse Size A Min Circuit Amp
9K 1Q09FF2BEA US09CB2BEA* 217456243 7,500 20/12.2/9.5 1/4" - 3/8" 10'/66' 10 9
12K 1Q12FF2BEA US12CB2BEA* 217456244 9,000 19.8/12/9.5 1/4" - 3/8" 10'/66' 10 9
18K 1Q18FF2BEA US18CB2BEA* 217456245 14,400 18.5/11.7/9.1 1/4" - 1/2" 10'/83' 20 15
24K 1Q24FF2BEA US24LB2BEA** 217463701 20,000 19.5/11.7/9.5 3/8" - 5/8" 10'/165' 30 20
30K 1Q3036FF2BEA US30LB2BEA** 217456246 24,000 19/11.2/10 3/8" - 3/4" 10'/165' 35 25
36K 1Q3036FF2BEA US36LB2BEA** 217456247 26,000 18.8/10.6/9.3 3/8" - 3/4" 10'/165' 35 25

*QACCP01WA panel required (sold separately). Built-in condensate pump. **QALCP01WA panel required (sold separately). Built-in condensate pump.

Console

Size Outdoor Model Indoor Model AHRI# Max Heat @ 5°F SEER2/EER2/HSPF2 (IV) Lineset: Liquid Suction Min/Max Line Length Max Fuse Size A Min Circuit Amp
9K 1Q09FF2BEA US09FB2BEA 217456248 8,500 20/12/9.5 1/4" - 3/8" 10'/66' 10 9
12K 1Q12FF2BEA US12FB2BEA 217456249 9,500 19/9.5/9.2 1/4" - 3/8" 10'/66' 10 9
18K 1Q18FF2BEA US18FB2BEA 217456250 12,600 17/8.6/7.8 1/4" - 1/2" 10'/83' 20 15

Mid-Static Ducted

Size Outdoor Model Indoor Model AHRI# Max Heat @ 5°F SEER2/EER2/HSPF2 (IV) Lineset: Liquid Suction Min/Max Line Length Max Fuse Size A Min Circuit Amp
9K 1Q09FF2BEA US09MB2BEA 217456254 8,000 17.8/11.7/9.4 1/4" - 3/8" 10'/66' 10 9
12K 1Q12FF2BEA US12MB2BEA 217456255 9,100 17/10.3/9.4 1/4" - 3/8" 10'/66' 10 9
18K 1Q18FF2BEA US18MB2BEA 217456256 15,200 17.3/10.8/9 1/4" - 1/2" 10'/83' 20 15
24K 1Q24FF2BEA US24MB2BEA 217456257 20,000 18/10/9.4 3/8" - 5/8" 10'/165' 30 20
30K 1Q3036FF2BEA US30MB2BEA 217456258 25,000 17/10.3/9.4 3/8" - 3/4" 10'/165' 35 25
36K 1Q3036FF2BEA US36MB2BEA 217456259 25,200 16/9.5/9 3/8" - 3/4" 10'/165' 35 25

Built-in condensate pump.

Premium Highwall

Key Features:

  • Up to 27 SEER2; 11 HSPF2
  • Cold climate compressor with basepan heater allows low ambient heating down to -31°F
  • Warm air in extreme conditions; up to 100% rated heating capacity at 5°F
  • Premium highwall includes built-in smart sensor

OPERATING RANGE (°F):

Cooling: -40 to 75°F; Heating (9-18K): -31 to 75°F; Heating (24K+): -22 to 75°F (Cooling below 23°F requires wind baffle).

Size Outdoor Model Indoor Model AHRI# Max Heat @ 5°F SEER2/EER2/HSPF2 (IV) Lineset: Liquid Suction Min/Max Line Length Max Fuse Size A Min Circuit Amp
9K 1Q09RT2BEA QS09WP2BEA 215876548 10,000 27/12.5/11 1/4" - 3/8" 10'/66' 20 13
12K 1Q12RT2BEA QS12WP2BEA 215876549 14,500 25/12.5/11 1/4" - 3/8" 10'/66' 20 14
18K 1Q18RT2BEA QS18WP2BEA 215876550 19,000 20.5/12/10 1/4" - 1/2" 10'/83' 30 20
24K 1Q24RT2BEA QS24WP2BEA 217465732 22,000 20/11.2/9.5 1/4" - 1/2" 10'/165' 30 22

Standard Highwall

Size Outdoor Model Indoor Model AHRI# Max Heat @ 5°F SEER2/EER2/HSPF2 (IV) Lineset: Liquid Suction Min/Max Line Length Max Fuse Size A Min Circuit Amp
30K 1Q3036RT2BEA QS30WB2BEA 217465734 25,800 20/11.2/9.5 3/8" - 5/8" 10'/165' 40 25
36K 1Q3036RT2BEA QS36WB2BEA 217465736 26,200 20/10.5/9.5 3/8" - 5/8" 10'/165' 40 25

Cassette

Size Outdoor Model Indoor Model AHRI# Max Heat @ 5°F SEER2/EER2/HSPF2 (IV) Lineset: Liquid Suction Min/Max Line Length Max Fuse Size A Min Circuit Amp
9K 1Q09RT2BEA US09CB2BEA* 217036488 9,000 20/12/10 1/4" - 3/8" 10'/66' 20 13
12K 1Q12RT2BEA US12CB2BEA* 217036489 10,000 20/12/10 1/4" - 3/8" 10'/66' 20 14
18K 1Q18RT2BEA US18CB2BEA* 217036490 14,400 20/12/10 1/4" - 1/2" 10'/83' 30 20
24K 1Q24RT2BEA US24LB2BEA** 217456225 22,000 20/12/10 3/8" - 5/8" 10'/165' 30 22
30K 1Q3036RT2BEA US30LB2BEA** 217456226 27,000 20/12/10 3/8" - 3/4" 10'/165' 40 25
36K 1Q3036RT2BAA US36LB2BEA** 217456227 29,000 19/11/10 3/8" - 3/4" 10'/165' 40 25

*QACCP01WA panel required (sold separately). Built-in condensate pump. **QALCP01WA panel required (sold separately). Built-in condensate pump.

Console

Size Outdoor Model Indoor Model AHRI# Max Heat @ 5°F SEER2/EER2/HSPF2 (IV) Lineset: Liquid Suction Min/Max Line Length Max Fuse Size A Min Circuit Amp
9K 1Q09RT2BEA US09FB2BEA 217036485 9,000 20/12/10.5 1/4" - 3/8" 10'/66' 20 13
12K 1Q12RT2BEA US12FB2BEA 217036486 10,000 20/12/9.5 1/4" - 3/8" 10'/66' 20 14
18K 1Q18RT2BEA US18FB2BEA 217036487 14,400 19/9/9.5 1/4" - 1/2" 10'/83' 30 20

Mid-Static Ducted

Size Outdoor Model Indoor Model AHRI# Max Heat @ 5°F SEER2/EER2/HSPF2 (IV) Lineset: Liquid Suction Min/Max Line Length Max Fuse Size A Min Circuit Amp
9K 1Q09RT2BEA US09MB2BEA 217036491 8,000 19.6/12/10.5 1/4" - 3/8" 10'/66' 20 13
12K 1Q12RT2BEA US12MB2BEA 217036492 10,000 19.8/11.7/10.5 1/4" - 3/8" 10'/66' 20 14
18K 1Q18RT2BEA US18MB2BEA 217036493 17,000 18/11.7/10.5 1/4" - 1/2" 10'/83' 30 20
24K 1Q24RT2BEA US24MB2BEA 217456220 23,000 18.2/11.7/10.5 3/8" - 5/8" 10'/165' 30 22
30K 1Q3036RT2BEA US30MB2BEA 217456221 24,000 17.6/10.8/10 3/8" - 3/4" 10'/165' 40 25
36K 1Q3036RT2BEA US36MB2BEA 217456222 26,000 17.4/9.8/9.5 3/8" - 3/4" 10'/165' 40 25

Built-in condensate pump.

Multi-Zone Systems

Multi-Zone Outdoor Units

FlexFit Series

Key Features:

  • Up to 24 SEER2; 10.0 HSPF2
  • Provides ~ 65% heating capacity at 5°F
Size Outdoor Model Max Line All Comb. Max Heat @ 5°F SEER2/EER2/HSPF2 (IV) Non-Ducted SEER2/EER2/HSPF2 (IV) Ducted AHRI# Max Fuse Size A Min Circuit Amp
18K 2Q18FF2BEA 98' 16,600 22.5/12/10.5 18.8/10.8/9.5 217009754 / 217021962 25 16
24K 3Q24FF2BEA 197' 17,600 24/12/10.2 17.2/10.5/9.5 217009755 / 217021963 25 18
36K 4Q36FF2BEA 230' 23,000 20/10/10 16.5/8.8/9.3 217009760 / 217021964 30 22

Arctic Series

Key Features:

  • Up to 23 SEER2; 10.5 HSPF2
  • Built-in basepan heater allows operating down to -22°F
  • Provides ~ 90% heating capacity at 5°F
Size Outdoor Model Max Line All Comb. Max Heat @ 5°F SEER2/EER2/HSPF2 (IV) Non-Ducted SEER2/EER2/HSPF2 (IV) Ducted AHRI# Max Fuse Size A Min Circuit Amp
20K 2Q20RT2BEA 164' 20,000 20.6/12.3/10.5 17.6/10.8/10.5 217009756 / 217021965 30 20
24K 3Q24RT2BEA 197' 22,800 23/12.2/10.5 17.2/10.5/10 217009757 / 217021966 30 21
36K 4Q36RT2BEA 230' 34,000 20.5/11/10 17.4/10.2/10 217009758 / 217021967 40 35
42K 5Q42RT2BEA 262' 35,000 20.5/10.5/9.5 17.4/10.2/9.5 217009759 / 217021968 40 36

Multi-Zone Indoor Units

Highwall

SizeIndoor ModelLineset: Liquid Suction
Standard 7KQS07WB2BEA1/4" - 3/8"
Standard 9KQS09WB2BEA1/4" - 3/8"
Standard 12KQS12WB2BEA1/4" - 3/8"
Standard 15KQS15WB2BEA1/4" - 3/8"
Standard 18KQS18WB2BEA1/4" - 1/2"
Standard 24KQS24WB2BEA1/4" - 1/2"
Premium 9KQS09WP2BEA1/4" - 3/8"
Premium 12KQS12WP2BEA1/4" - 3/8"
Premium 18KQS18WP2BEA1/4" - 1/2"
Premium 24KQS24WP2BEA1/4" - 1/2"

Cassette

SizeIndoor ModelLineset: Liquid Suction
Compact 9KUS09CB2BEA*1/4" - 3/8"
Compact 12KUS12CB2BEA*1/4" - 3/8"
Compact 18KUS18CB2BEA*1/4" - 1/2"
Large 24KUS24LB2BEA**3/8" - 5/8"
Large 30KUS30LB2BEA**3/8" - 3/4"
Large 36KUS36LB2BEA**3/8" - 3/4"

*QACCP01WA panel required (sold separately). Built-in condensate pump. **QALCP01WA panel required (sold separately). Built-in condensate pump.

Console

SizeIndoor ModelLineset: Liquid Suction
9KUS09FB2BEA1/4" - 3/8"
12KUS12FB2BEA1/4" - 3/8"
18KUS18FB2BEA1/4" - 1/2"

Mid-Static Ducted

SizeIndoor ModelLineset: Liquid Suction
7KUS07MB2BEA1/4" - 3/8"
9KUS09MB2BEA1/4" - 3/8"
12KUS12MB2BEA1/4" - 3/8"
18KUS18MB2BEA1/4" - 1/2"
24KUS24MB2BEA3/8" - 5/8"
Built-in condensate pump.

Multi-Zone Capacity Combination Matrix

This section details the compatibility between Haier multi-zone outdoor units and indoor units, including required adapters.

2Q18FF2B** / 2Q20RT2B** (Two Zone)

No adapters required/shipped.

Port B (Size: 1/4" x 3/8")Port A (Size: 1/4" x 3/8")
7K7K
9K7K
9K9K
12K7K
12K9K
12K12K
15K7K
15K9K

3Q24FF2B** / 3Q24RT2B** (Three Zone)

No adapters required for Ports B, A.

Port C (Size: 1/4" x 3/8")Required AdapterPort B (Size: 1/4" x 3/8")Port A (Size: 1/4" x 3/8")
7K-7K7K
9K-9K7K
9K-9K9K
12K-12K7K
12K-12K9K
12K-12K12K
15K-15K7K
15K-15K9K
15K-15K12K
15K-15K15K
18KD7K7K
18KD9K7K
18KD12K7K
24KA, C7K7K
24KA, C9K7K
24KA, C12K7K
24KA, C15K7K
24KA, C18K7K

4Q36FF2B** / 4Q36RT2B** (Four Zone)

Ships with adapters D and E. No adapters required for Ports B, A.

Port D (Size: 1/4" x 1/2")Required AdapterPort C (Size: 1/4" x 3/8")Required AdapterPort B (Size: 1/4" x 3/8")Port A (Size: 1/4" x 3/8")
18K-9K-9K9K
18K-12K-9K7K
18K-15K-12K7K
18K-18KD12K9K
24KA, C7K-15K7K
24KA, C9K-15K9K
24KA, C12K-15K12K
24KA, C15K-18K7K
24KA, C18KD18K9K
24KA, C24K-18K12K
18K-9K-7K7K
18K-12K-7K7K
18K-15K-9K7K
18K-18KD9K9K
24KA, C7K-12K7K
24KA, C9K-12K9K
24KA, C12K-12K12K
24KA, C15K-15K7K
24KA, C18KD15K9K
24KA, C24K-15K12K
18KE7K-7K7K
18KE9K-7K7K
18KE12K-9K7K
18KE15K-9K9K
18KE18KD12K7K
24KA, C7K-12K9K
24KA, C9K-12K12K
24KA, C12K-15K7K
24KA, C15K-15K9K
24KA, C18KD15K12K
24KA, C24K-18K15K
18KE7K-7K7K
18KE9K-7K7K
18KE12K-9K7K
18KE15K-9K9K
18KE18KD12K7K
24KA, C7K-12K9K
24KA, C9K-12K12K
24KA, C12K-15K7K
24KA, C15K-15K9K
24KA, C18KD15K12K
24KA, C24K-18K15K

Lineset Adapters

AdapterPart #
A: 1/4" to 3/8" (Liquid line for ports C & D)WJ01X35713
B: 3/8" to 5/8" (Vapor line for port C)WJ01X35714
C: 1/2" to 5/8" (Vapor line for port D)WJ01X35715
D: 3/8"to 1/2" (Vapor line for port C)WJ01X35716
E: 1/2" to 3/8" (Vapor line for port C or D)WJ01X35717

Notes:

  • These 24K models require 3/8" liquid and 5/8" vapor linesets: US24LB2BE**, US24MB2BE**.
  • These 24K models require 1/4" liquid and 1/2" vapor linesets: QS24WB2B**, QS24WP2B**.
  • All 18K models require 1/4" liquid and 1/2" vapor linesets.
  • All 7K, 9K, 12K and 15K models require 1/4" liquid and 3/8" vapor linesets.

Indoor and Outdoor Compatibility Chart

This chart shows the compatibility between various Haier indoor and outdoor units.

TEMPO 115V TEMPO 230V FLEXFIT ARCTIC FLEXFIT MULTI ARCTIC MULTI
INDOOR STANDARD HIGHWALL UNITS
QS09WB1BEA
QS12WB1BEA
QS07WB2BEA
QS09WB2BEA
QS12WB2BEA
QS15WB2BEA
QS18WB2BEA
QS24WB2BEA
QS30WB2BEA
QS36WB2BEA
INDOOR PREMIUM HIGHWALL UNITS
QS09WP2BEA
QS12WP2BEA
QS18WP2BEA
QS24WP2BEA
INDOOR COMPACT CASSETTE UNITS
US09CB2BEA
US12CB2BEA
US18CB2BEA
INDOOR LARGE CASSETTE UNITS
US24LB2BEA
US30LB2BEA
US36LB2BEA
INDOOR CONSOLE UNITS
US09FB2BEA
US12FB2BEA
US18FB2BEA
INDOOR DUCTED UNITS
US07MB2BEA
US09MB2BEA
US12MB2BEA
US18MB2BEA
US24MB2BEA
US30MB2BEA
US36MB2BEA

Ductless Accessories

Wind Baffles & Top Covers

Image shows a Haier outdoor unit with numbered callouts for accessory locations: 1. Front/Back Wind Baffle, 2. Side Wind Baffle, 3. Top Cover, 4. Outdoor Unit.

Recommended Accessories by Operating Conditions:

Operating Conditions Front Wind Baffle Side Wind Baffle Back Wind Baffle Top Cover
Low Ambient Cooling below 23°F (5°C) (server/mechanical room) Required Required Required Required
Low Ambient Heating below 5°F (-15°C) - Strongly Recommended Strongly Recommended Strongly Recommended
Unit installed on a flat roof or facing prevailing wind Required - - -

Fabricated from durable 20 gauge G90 galvanized steel and engineered to provide optimal performance in cold, harsh climates. A front wind baffle is required for all climates when mounted on a flat roof or facing prevailing winds.

Outdoor Unit Accessory Compatibility Table

TEMPO 115V TEMPO 230V FLEXFIT ARCTIC ARCTIC MULTI FLEXFIT MULTI
FRONT OR BACK WIND BAFFLES
UAWB15WA
UAWB30WA
UAWB31WA
UAWB51WA
SIDE WIND BAFFLES
UASWB15WA
UASWB30WA
UASWB31WA
UASWB51WA
TOP COVERS
UATC15WA
UATC20WA
UATC21WA
UATC30WA
UATC31WA
UATC35WA
UATC51WA
5" CENTRAL CONTROLLER
UACT32A

Cassette Panels

Required for cassette indoor units; sold separately. Remote controller (WJ26X35394) is included with cassette panel.

  • QACCP01WA Compact Cassette Panel: Fits Models: US09CB2BEA, US12CB2BEA, US18CB2BEA
  • QALCP01WA Large Cassette Panel: Fits Models: US24LB2BEA, US30LB2BEA, US36LB2BEA

Supply Plenums

Supply plenums for ducted indoor models.

  • UAPT0912A: Fits Models: US09MB2BEA, US12MB2BEA
  • UAPT1824A: Fits Models: US18MB2BEA, US24MB2BEA
  • UAPT3048A: Fits Models: US30MB2BEA, US36MB2BEA, US42MB2BEA, US48MB2BEA

Merv Return Air Filter Boxes

MERV return air filter boxes for ducted indoor models.

  • UAMFB0912A: Fits Models: US09MB2BEA, US12MB2BEA
  • UAMFB1824A: Fits Models: US18MB2BEA, US24MB2BEA
  • UAMFB3048A: Fits Models: US30MB2BEA, US36MB2BEA, US42MB2BEA, US48MB2BEA

Refrigerant Detection Sensor (RDS)

UALS01A Ductless Refrigerant Detection Sensor. Note: See room sizing requirements to determine if the Refrigerant Detection Sensor (RDS) is required and needs to be purchased separately for highwall and cassette indoor units. RDS is factory-installed on console and ducted units.

Controllers

Controllers from Haier allow for convenient system command and comfort level management.

Wired Controller

QACT17B: Compatible with all indoor unit types. Features include power supply, controllable groups, modes, precise temperature control, fan speed adjustment, and more.

Remote Controllers

Available in multiple types for individual control, featuring Up/Down Louver Oscillating Control, Left/Right Louver Oscillating Control, Four-Way Cassette Air Supply Control, Child Lock, and more.

  • WJ26X35393: Ships with standard highwalls.
  • WJ26X35813: Ships with consoles.
  • WJ26X35394: Ships with premium highwalls & cassette panels.

5" Central Controller

UACT32A: Features a 5" LED Touch Screen for intuitive navigation. Offers seamless integration of ductless and central HVAC systems. Manages up to 31 ductless zones and 1 central 24V HVAC zone.

Key Specifications:

  • Power Supply: 24VAC*
  • Max. IDUs Controllable: 31 + (1) 24VAC Central Zone
  • Temperature Set Range: 60-86°F (16-30°C)
  • Zones: Up to 31 Zones
  • Modes: Cool, Heat, Auto, Dry, Fan
  • Fan Speeds: Low, Med, High
  • Humidity: Display in %
  • Mode: Cool, Heat, Auto
  • Fan Speed: Auto, Circulating, On
  • Connectivity: WiFi/Alexa/Google Home

*If not connecting to 24V central HVAC system, a field supplied 24VAC transformer is needed.

Indoor Unit Accessory Compatibility Table

This table details the compatibility of indoor units with various accessories.

Model Number Remote Controllers (WJ26X35393) Remote Controllers (WJ26X35813) Remote Controllers (WJ26X35394) Wired Controller (QACT17B) Refrigerant Detection Sensor (RDS) (UALS01A)
QS09WB1BEA
QS12WB1BEA
QS07WB2BEA
QS09WB2BEA
QS12WB2BEA
QS15WB2BEA
QS18WB2BEA
QS24WB2BEA
QS30WB2BEA
QS36WB2BEA
QS09WP2BEA
QS12WP2BEA
QS18WP2BEA
QS24WP2BEA
US09CB2BEA
US12CB2BEA
US18CB2BEA
QACCP01WA*
US24LB2BEA
US30LB2BEA
US36LB2BEA
QALCP01WA*
US09FB2BEA
US12FB2BEA
US18FB2BEA
US09MB2BEA
US12MB2BEA
US18MB2BEA
US24MB2BEA
US30MB2BEA
US36MB2BEA
US42MB2BEA
US48MB2BEA

*Cassette Panel. Key: ✔ = Included, Required, sold separately; ○ = Optional; sold separately. See Outdoor Unit Accessory Compatibility Table for 5" Central Controller compatibility.

Model Number Nomenclature

Ductless Outdoor Unit Nomenclature

This section explains the structure of Haier's ductless outdoor unit model numbers.

Format: 1 Q 18 T E 2 B E A 1

  • Zones: 1 (Single Zone), 2/3/4 (Multi-Zone)
  • Brand: Q (Haier)
  • BTUs: e.g., 18 (18,000 BTU), 36 (36,000 BTU), 3036 (Cross Tonnage Product)
  • Model Family: TE (Tempo), FF (FlexFit), RT (Arctic)
  • Voltage: 1 (115V), 2 (230V)
  • Refrigerant: B (R454B: Heat Pump)
  • Model Design Year: E (2025), F (2026), G (2027)
  • Minor Marketing Revision: A
  • Engineering Digit: 1

Example: 1Q12TE2BEA: Haier 12K Tempo Single Zone

Ductless Indoor Unit Nomenclature

This section explains the structure of Haier's ductless indoor unit model numbers.

Format: Q S 09 W P 2 B E A 1

  • Brand: Q (Haier), U (Universal)
  • Type: S (Split)
  • BTUs: e.g., 09 (9,000 BTU), 36 (36,000 BTU)
  • IDU Type: W (Wall Mount), M (Mid-Static Ducted), F (Floor Console), C (Compact Cassette), A (One-Way Cassette), L (Large Cassette)
  • IDU Sub-Type: B (Basic), P (Premium)
  • Voltage: 1 (115V), 2 (230V)
  • Refrigerant: B (R454B: Heat Pump)
  • Model Design Year: E (2025), F (2026), G (2027)
  • Minor Marketing Revision: A
  • Engineering Digit: 1

Examples: QS09WB2BEA: Haier 9K Standard Highwall; US12MB2BEA: Universal 12K Ducted

Limited Warranty

Haier (GE Appliances) offers a 5-year limited warranty on parts. An extended 10-year limited warranty on parts is available with registration within 60 days of installation.

To register your equipment, visit: www.geappliancesairandwater.com/warranty

GE Appliances has a policy of continuous improvement and reserves the right to change materials and specifications without notice.

PDF preview unavailable. Download the PDF instead.

nzbszklo5v2rxaqqfmcj Adobe InDesign 20.4 (Windows) Adobe PDF Library 17.0

Related Documents

Preview Haier Tempo Air Conditioner 2.5kW Quick Reference Guide
Concise guide for the Haier Tempo 2.5kW air conditioner, detailing features like Wi-Fi control and self-cleaning, specifications, dimensions, warranty, and customer support. Optimized for SEO.
Preview Haier Multi-Zone Solutions: Features, Specifications, and Compatibility
Explore Haier's Multi-Zone HVAC solutions, including FlexFit and Arctic Series, with detailed specifications for outdoor and indoor units, features, and capacity combination matrices. Find the perfect system for your multi-zone application.
Preview Haier Technical Manual 2020
Comprehensive technical manual for Haier air conditioning units from 2020, covering product specifications, troubleshooting, and operational guidance.
Preview Haier HVAC Solutions Catalog 2025/26 for Residential and Light Commercial Buildings
Explore the Haier HVAC Solutions Catalog 2025/26, featuring a comprehensive range of products for residential and light commercial buildings. Discover Haier's commitment to intelligent and healthy air solutions, innovative technologies, and global leadership in the HVAC industry.
Preview Haier Arctic Series Submittals: Highwall, Cassette, and Ducted Systems
Comprehensive submittal data for Haier's Arctic Series ductless mini-split heat pump systems, including highwall, compact cassette, and mid-static ducted indoor units. Details specifications, capacities, and dimensions for various models.
Preview Haier Multi-Split Air Conditioner Installation Manual | Models 3U, 4U, 5U Series
Comprehensive installation guide for Haier Multi-Split Air Conditioner systems, covering safety, procedures, wiring, refrigerant handling, and troubleshooting for models 3U55S2PR1FA, 4U71S2PR1FA, 4U80S2PR1FA, 5U100S2PS1FA, and 5U125S2PN1FA.
Preview Haier Tempo Air Conditioner 2.5kW - Quick Reference Guide and Specifications
Detailed quick reference guide for the Haier Tempo Air Conditioner 2.5kW (AS26TACHRA), covering features like Wi-Fi and voice control, intelligent air flow, sleep mode, and comprehensive specifications including dimensions, capacity, and warranty.
Preview Haier Multi-Split Cassette Air Conditioner Specifications
Technical specifications for Haier Multi-Split cassette air conditioning units, including dimensions, gas line size, and weight for various models.