Ductless Mini and Multi-Split Quick Reference Guide
This guide provides essential specifications and compatibility information for Haier's ductless mini and multi-split HVAC systems.
Single-Zone Systems
Standard Highwall
Key Features:
- Up to 23 SEER2; 9.5 HSPF2
- 09/12K 115V options with basepan heater
- 09/12/18/24K 230V options with highwall matches
OPERATING RANGE (°F):
Cooling: -40 to 75°F; Heating: -31 to 75°F (Cooling below 23°F requires wind baffle).
Size | Outdoor Model | Indoor Model | AHRI# | Max Heat @ 5°F | SEER2/EER2/HSPF2 (IV) | Lineset: Liquid Suction | Min/Max Line Length | Max Fuse Size A | Min Circuit Amp |
---|---|---|---|---|---|---|---|---|---|
9K (115V) | 1Q09TE1BEA | QS09WB1BEA | 215564827 | 7,000 | 20/12/9.5 | 1/4" - 3/8" | 10'/66' | 25 | 18 |
12K (115V) | 1Q12TE1BEA | QS12WB1BEA | 215564828 | 9,000 | 20/12/9.5 | 1/4" - 3/8" | 10'/66' | 25 | 18 |
9K (230V) | 1Q09TE2BEA | QS09WB2BEA | 217124721 | 8,000 | 23/12/9.5 | 1/4" - 3/8" | 10'/66' | 10 | 9 |
12K (230V) | 1Q12TE2BEA | QS12WB2BEA | 217124722 | 10,400 | 21/12/9.5 | 1/4" - 3/8" | 10'/66' | 10 | 9 |
18K (230V) | 1Q18TE2BEA | QS18WB2BEA | 217124723 | 15,200 | 20/12/9.5 | 1/4" - 1/2" | 10'/83' | 20 | 15 |
24K (230V) | 1Q24TE2BEA | QS24WB2BEA | 217124724 | 19,200 | 18/12/9.5 | 1/4" - 1/2" | 10'/165' | 30 | 20 |
Cassette
Key Features:
- Up to 23 SEER2; 9.5 HSPF2
- Low ambient heating down to -15°F (built-in basepan heater)
- -40°F low ambient cooling with wind baffle & top cover (sold separately)
OPERATING RANGE (°F):
Cooling: -40 to 75°F; Heating: -31 to 75°F (Cooling below 23°F requires wind baffle).
Size | Outdoor Model | Indoor Model | AHRI# | Max Heat @ 5°F | SEER2/EER2/HSPF2 (IV) | Lineset: Liquid Suction | Min/Max Line Length | Max Fuse Size A | Min Circuit Amp |
---|---|---|---|---|---|---|---|---|---|
9K | 1Q09FF2BEA | US09CB2BEA* | 217456243 | 7,500 | 20/12.2/9.5 | 1/4" - 3/8" | 10'/66' | 10 | 9 |
12K | 1Q12FF2BEA | US12CB2BEA* | 217456244 | 9,000 | 19.8/12/9.5 | 1/4" - 3/8" | 10'/66' | 10 | 9 |
18K | 1Q18FF2BEA | US18CB2BEA* | 217456245 | 14,400 | 18.5/11.7/9.1 | 1/4" - 1/2" | 10'/83' | 20 | 15 |
24K | 1Q24FF2BEA | US24LB2BEA** | 217463701 | 20,000 | 19.5/11.7/9.5 | 3/8" - 5/8" | 10'/165' | 30 | 20 |
30K | 1Q3036FF2BEA | US30LB2BEA** | 217456246 | 24,000 | 19/11.2/10 | 3/8" - 3/4" | 10'/165' | 35 | 25 |
36K | 1Q3036FF2BEA | US36LB2BEA** | 217456247 | 26,000 | 18.8/10.6/9.3 | 3/8" - 3/4" | 10'/165' | 35 | 25 |
*QACCP01WA panel required (sold separately). Built-in condensate pump. **QALCP01WA panel required (sold separately). Built-in condensate pump.
Console
Size | Outdoor Model | Indoor Model | AHRI# | Max Heat @ 5°F | SEER2/EER2/HSPF2 (IV) | Lineset: Liquid Suction | Min/Max Line Length | Max Fuse Size A | Min Circuit Amp |
---|---|---|---|---|---|---|---|---|---|
9K | 1Q09FF2BEA | US09FB2BEA | 217456248 | 8,500 | 20/12/9.5 | 1/4" - 3/8" | 10'/66' | 10 | 9 |
12K | 1Q12FF2BEA | US12FB2BEA | 217456249 | 9,500 | 19/9.5/9.2 | 1/4" - 3/8" | 10'/66' | 10 | 9 |
18K | 1Q18FF2BEA | US18FB2BEA | 217456250 | 12,600 | 17/8.6/7.8 | 1/4" - 1/2" | 10'/83' | 20 | 15 |
Mid-Static Ducted
Size | Outdoor Model | Indoor Model | AHRI# | Max Heat @ 5°F | SEER2/EER2/HSPF2 (IV) | Lineset: Liquid Suction | Min/Max Line Length | Max Fuse Size A | Min Circuit Amp |
---|---|---|---|---|---|---|---|---|---|
9K | 1Q09FF2BEA | US09MB2BEA | 217456254 | 8,000 | 17.8/11.7/9.4 | 1/4" - 3/8" | 10'/66' | 10 | 9 |
12K | 1Q12FF2BEA | US12MB2BEA | 217456255 | 9,100 | 17/10.3/9.4 | 1/4" - 3/8" | 10'/66' | 10 | 9 |
18K | 1Q18FF2BEA | US18MB2BEA | 217456256 | 15,200 | 17.3/10.8/9 | 1/4" - 1/2" | 10'/83' | 20 | 15 |
24K | 1Q24FF2BEA | US24MB2BEA | 217456257 | 20,000 | 18/10/9.4 | 3/8" - 5/8" | 10'/165' | 30 | 20 |
30K | 1Q3036FF2BEA | US30MB2BEA | 217456258 | 25,000 | 17/10.3/9.4 | 3/8" - 3/4" | 10'/165' | 35 | 25 |
36K | 1Q3036FF2BEA | US36MB2BEA | 217456259 | 25,200 | 16/9.5/9 | 3/8" - 3/4" | 10'/165' | 35 | 25 |
Built-in condensate pump.
Premium Highwall
Key Features:
- Up to 27 SEER2; 11 HSPF2
- Cold climate compressor with basepan heater allows low ambient heating down to -31°F
- Warm air in extreme conditions; up to 100% rated heating capacity at 5°F
- Premium highwall includes built-in smart sensor
OPERATING RANGE (°F):
Cooling: -40 to 75°F; Heating (9-18K): -31 to 75°F; Heating (24K+): -22 to 75°F (Cooling below 23°F requires wind baffle).
Size | Outdoor Model | Indoor Model | AHRI# | Max Heat @ 5°F | SEER2/EER2/HSPF2 (IV) | Lineset: Liquid Suction | Min/Max Line Length | Max Fuse Size A | Min Circuit Amp |
---|---|---|---|---|---|---|---|---|---|
9K | 1Q09RT2BEA | QS09WP2BEA | 215876548 | 10,000 | 27/12.5/11 | 1/4" - 3/8" | 10'/66' | 20 | 13 |
12K | 1Q12RT2BEA | QS12WP2BEA | 215876549 | 14,500 | 25/12.5/11 | 1/4" - 3/8" | 10'/66' | 20 | 14 |
18K | 1Q18RT2BEA | QS18WP2BEA | 215876550 | 19,000 | 20.5/12/10 | 1/4" - 1/2" | 10'/83' | 30 | 20 |
24K | 1Q24RT2BEA | QS24WP2BEA | 217465732 | 22,000 | 20/11.2/9.5 | 1/4" - 1/2" | 10'/165' | 30 | 22 |
Standard Highwall
Size | Outdoor Model | Indoor Model | AHRI# | Max Heat @ 5°F | SEER2/EER2/HSPF2 (IV) | Lineset: Liquid Suction | Min/Max Line Length | Max Fuse Size A | Min Circuit Amp |
---|---|---|---|---|---|---|---|---|---|
30K | 1Q3036RT2BEA | QS30WB2BEA | 217465734 | 25,800 | 20/11.2/9.5 | 3/8" - 5/8" | 10'/165' | 40 | 25 |
36K | 1Q3036RT2BEA | QS36WB2BEA | 217465736 | 26,200 | 20/10.5/9.5 | 3/8" - 5/8" | 10'/165' | 40 | 25 |
Cassette
Size | Outdoor Model | Indoor Model | AHRI# | Max Heat @ 5°F | SEER2/EER2/HSPF2 (IV) | Lineset: Liquid Suction | Min/Max Line Length | Max Fuse Size A | Min Circuit Amp |
---|---|---|---|---|---|---|---|---|---|
9K | 1Q09RT2BEA | US09CB2BEA* | 217036488 | 9,000 | 20/12/10 | 1/4" - 3/8" | 10'/66' | 20 | 13 |
12K | 1Q12RT2BEA | US12CB2BEA* | 217036489 | 10,000 | 20/12/10 | 1/4" - 3/8" | 10'/66' | 20 | 14 |
18K | 1Q18RT2BEA | US18CB2BEA* | 217036490 | 14,400 | 20/12/10 | 1/4" - 1/2" | 10'/83' | 30 | 20 |
24K | 1Q24RT2BEA | US24LB2BEA** | 217456225 | 22,000 | 20/12/10 | 3/8" - 5/8" | 10'/165' | 30 | 22 |
30K | 1Q3036RT2BEA | US30LB2BEA** | 217456226 | 27,000 | 20/12/10 | 3/8" - 3/4" | 10'/165' | 40 | 25 |
36K | 1Q3036RT2BAA | US36LB2BEA** | 217456227 | 29,000 | 19/11/10 | 3/8" - 3/4" | 10'/165' | 40 | 25 |
*QACCP01WA panel required (sold separately). Built-in condensate pump. **QALCP01WA panel required (sold separately). Built-in condensate pump.
Console
Size | Outdoor Model | Indoor Model | AHRI# | Max Heat @ 5°F | SEER2/EER2/HSPF2 (IV) | Lineset: Liquid Suction | Min/Max Line Length | Max Fuse Size A | Min Circuit Amp |
---|---|---|---|---|---|---|---|---|---|
9K | 1Q09RT2BEA | US09FB2BEA | 217036485 | 9,000 | 20/12/10.5 | 1/4" - 3/8" | 10'/66' | 20 | 13 |
12K | 1Q12RT2BEA | US12FB2BEA | 217036486 | 10,000 | 20/12/9.5 | 1/4" - 3/8" | 10'/66' | 20 | 14 |
18K | 1Q18RT2BEA | US18FB2BEA | 217036487 | 14,400 | 19/9/9.5 | 1/4" - 1/2" | 10'/83' | 30 | 20 |
Mid-Static Ducted
Size | Outdoor Model | Indoor Model | AHRI# | Max Heat @ 5°F | SEER2/EER2/HSPF2 (IV) | Lineset: Liquid Suction | Min/Max Line Length | Max Fuse Size A | Min Circuit Amp |
---|---|---|---|---|---|---|---|---|---|
9K | 1Q09RT2BEA | US09MB2BEA | 217036491 | 8,000 | 19.6/12/10.5 | 1/4" - 3/8" | 10'/66' | 20 | 13 |
12K | 1Q12RT2BEA | US12MB2BEA | 217036492 | 10,000 | 19.8/11.7/10.5 | 1/4" - 3/8" | 10'/66' | 20 | 14 |
18K | 1Q18RT2BEA | US18MB2BEA | 217036493 | 17,000 | 18/11.7/10.5 | 1/4" - 1/2" | 10'/83' | 30 | 20 |
24K | 1Q24RT2BEA | US24MB2BEA | 217456220 | 23,000 | 18.2/11.7/10.5 | 3/8" - 5/8" | 10'/165' | 30 | 22 |
30K | 1Q3036RT2BEA | US30MB2BEA | 217456221 | 24,000 | 17.6/10.8/10 | 3/8" - 3/4" | 10'/165' | 40 | 25 |
36K | 1Q3036RT2BEA | US36MB2BEA | 217456222 | 26,000 | 17.4/9.8/9.5 | 3/8" - 3/4" | 10'/165' | 40 | 25 |
Built-in condensate pump.
Multi-Zone Systems
Multi-Zone Outdoor Units
FlexFit Series
Key Features:
- Up to 24 SEER2; 10.0 HSPF2
- Provides ~ 65% heating capacity at 5°F
Size | Outdoor Model | Max Line All Comb. | Max Heat @ 5°F | SEER2/EER2/HSPF2 (IV) Non-Ducted | SEER2/EER2/HSPF2 (IV) Ducted | AHRI# | Max Fuse Size A | Min Circuit Amp |
---|---|---|---|---|---|---|---|---|
18K | 2Q18FF2BEA | 98' | 16,600 | 22.5/12/10.5 | 18.8/10.8/9.5 | 217009754 / 217021962 | 25 | 16 |
24K | 3Q24FF2BEA | 197' | 17,600 | 24/12/10.2 | 17.2/10.5/9.5 | 217009755 / 217021963 | 25 | 18 |
36K | 4Q36FF2BEA | 230' | 23,000 | 20/10/10 | 16.5/8.8/9.3 | 217009760 / 217021964 | 30 | 22 |
Arctic Series
Key Features:
- Up to 23 SEER2; 10.5 HSPF2
- Built-in basepan heater allows operating down to -22°F
- Provides ~ 90% heating capacity at 5°F
Size | Outdoor Model | Max Line All Comb. | Max Heat @ 5°F | SEER2/EER2/HSPF2 (IV) Non-Ducted | SEER2/EER2/HSPF2 (IV) Ducted | AHRI# | Max Fuse Size A | Min Circuit Amp |
---|---|---|---|---|---|---|---|---|
20K | 2Q20RT2BEA | 164' | 20,000 | 20.6/12.3/10.5 | 17.6/10.8/10.5 | 217009756 / 217021965 | 30 | 20 |
24K | 3Q24RT2BEA | 197' | 22,800 | 23/12.2/10.5 | 17.2/10.5/10 | 217009757 / 217021966 | 30 | 21 |
36K | 4Q36RT2BEA | 230' | 34,000 | 20.5/11/10 | 17.4/10.2/10 | 217009758 / 217021967 | 40 | 35 |
42K | 5Q42RT2BEA | 262' | 35,000 | 20.5/10.5/9.5 | 17.4/10.2/9.5 | 217009759 / 217021968 | 40 | 36 |
Multi-Zone Indoor Units
Highwall
Size | Indoor Model | Lineset: Liquid Suction |
---|---|---|
Standard 7K | QS07WB2BEA | 1/4" - 3/8" |
Standard 9K | QS09WB2BEA | 1/4" - 3/8" |
Standard 12K | QS12WB2BEA | 1/4" - 3/8" |
Standard 15K | QS15WB2BEA | 1/4" - 3/8" |
Standard 18K | QS18WB2BEA | 1/4" - 1/2" |
Standard 24K | QS24WB2BEA | 1/4" - 1/2" |
Premium 9K | QS09WP2BEA | 1/4" - 3/8" |
Premium 12K | QS12WP2BEA | 1/4" - 3/8" |
Premium 18K | QS18WP2BEA | 1/4" - 1/2" |
Premium 24K | QS24WP2BEA | 1/4" - 1/2" |
Cassette
Size | Indoor Model | Lineset: Liquid Suction |
---|---|---|
Compact 9K | US09CB2BEA* | 1/4" - 3/8" |
Compact 12K | US12CB2BEA* | 1/4" - 3/8" |
Compact 18K | US18CB2BEA* | 1/4" - 1/2" |
Large 24K | US24LB2BEA** | 3/8" - 5/8" |
Large 30K | US30LB2BEA** | 3/8" - 3/4" |
Large 36K | US36LB2BEA** | 3/8" - 3/4" |
*QACCP01WA panel required (sold separately). Built-in condensate pump. **QALCP01WA panel required (sold separately). Built-in condensate pump.
Console
Size | Indoor Model | Lineset: Liquid Suction |
---|---|---|
9K | US09FB2BEA | 1/4" - 3/8" |
12K | US12FB2BEA | 1/4" - 3/8" |
18K | US18FB2BEA | 1/4" - 1/2" |
Mid-Static Ducted
Size | Indoor Model | Lineset: Liquid Suction |
---|---|---|
7K | US07MB2BEA | 1/4" - 3/8" |
9K | US09MB2BEA | 1/4" - 3/8" |
12K | US12MB2BEA | 1/4" - 3/8" |
18K | US18MB2BEA | 1/4" - 1/2" |
24K | US24MB2BEA | 3/8" - 5/8" |
Built-in condensate pump. |
Multi-Zone Capacity Combination Matrix
This section details the compatibility between Haier multi-zone outdoor units and indoor units, including required adapters.
2Q18FF2B** / 2Q20RT2B** (Two Zone)
No adapters required/shipped.
Port B (Size: 1/4" x 3/8") | Port A (Size: 1/4" x 3/8") |
---|---|
7K | 7K |
9K | 7K |
9K | 9K |
12K | 7K |
12K | 9K |
12K | 12K |
15K | 7K |
15K | 9K |
3Q24FF2B** / 3Q24RT2B** (Three Zone)
No adapters required for Ports B, A.
Port C (Size: 1/4" x 3/8") | Required Adapter | Port B (Size: 1/4" x 3/8") | Port A (Size: 1/4" x 3/8") |
---|---|---|---|
7K | - | 7K | 7K |
9K | - | 9K | 7K |
9K | - | 9K | 9K |
12K | - | 12K | 7K |
12K | - | 12K | 9K |
12K | - | 12K | 12K |
15K | - | 15K | 7K |
15K | - | 15K | 9K |
15K | - | 15K | 12K |
15K | - | 15K | 15K |
18K | D | 7K | 7K |
18K | D | 9K | 7K |
18K | D | 12K | 7K |
24K | A, C | 7K | 7K |
24K | A, C | 9K | 7K |
24K | A, C | 12K | 7K |
24K | A, C | 15K | 7K |
24K | A, C | 18K | 7K |
4Q36FF2B** / 4Q36RT2B** (Four Zone)
Ships with adapters D and E. No adapters required for Ports B, A.
Port D (Size: 1/4" x 1/2") | Required Adapter | Port C (Size: 1/4" x 3/8") | Required Adapter | Port B (Size: 1/4" x 3/8") | Port A (Size: 1/4" x 3/8") |
---|---|---|---|---|---|
18K | - | 9K | - | 9K | 9K |
18K | - | 12K | - | 9K | 7K |
18K | - | 15K | - | 12K | 7K |
18K | - | 18K | D | 12K | 9K |
24K | A, C | 7K | - | 15K | 7K |
24K | A, C | 9K | - | 15K | 9K |
24K | A, C | 12K | - | 15K | 12K |
24K | A, C | 15K | - | 18K | 7K |
24K | A, C | 18K | D | 18K | 9K |
24K | A, C | 24K | - | 18K | 12K |
18K | - | 9K | - | 7K | 7K |
18K | - | 12K | - | 7K | 7K |
18K | - | 15K | - | 9K | 7K |
18K | - | 18K | D | 9K | 9K |
24K | A, C | 7K | - | 12K | 7K |
24K | A, C | 9K | - | 12K | 9K |
24K | A, C | 12K | - | 12K | 12K |
24K | A, C | 15K | - | 15K | 7K |
24K | A, C | 18K | D | 15K | 9K |
24K | A, C | 24K | - | 15K | 12K |
18K | E | 7K | - | 7K | 7K |
18K | E | 9K | - | 7K | 7K |
18K | E | 12K | - | 9K | 7K |
18K | E | 15K | - | 9K | 9K |
18K | E | 18K | D | 12K | 7K |
24K | A, C | 7K | - | 12K | 9K |
24K | A, C | 9K | - | 12K | 12K |
24K | A, C | 12K | - | 15K | 7K |
24K | A, C | 15K | - | 15K | 9K |
24K | A, C | 18K | D | 15K | 12K |
24K | A, C | 24K | - | 18K | 15K |
18K | E | 7K | - | 7K | 7K |
18K | E | 9K | - | 7K | 7K |
18K | E | 12K | - | 9K | 7K |
18K | E | 15K | - | 9K | 9K |
18K | E | 18K | D | 12K | 7K |
24K | A, C | 7K | - | 12K | 9K |
24K | A, C | 9K | - | 12K | 12K |
24K | A, C | 12K | - | 15K | 7K |
24K | A, C | 15K | - | 15K | 9K |
24K | A, C | 18K | D | 15K | 12K |
24K | A, C | 24K | - | 18K | 15K |
Lineset Adapters
Adapter | Part # |
---|---|
A: 1/4" to 3/8" (Liquid line for ports C & D) | WJ01X35713 |
B: 3/8" to 5/8" (Vapor line for port C) | WJ01X35714 |
C: 1/2" to 5/8" (Vapor line for port D) | WJ01X35715 |
D: 3/8"to 1/2" (Vapor line for port C) | WJ01X35716 |
E: 1/2" to 3/8" (Vapor line for port C or D) | WJ01X35717 |
Notes:
- These 24K models require 3/8" liquid and 5/8" vapor linesets: US24LB2BE**, US24MB2BE**.
- These 24K models require 1/4" liquid and 1/2" vapor linesets: QS24WB2B**, QS24WP2B**.
- All 18K models require 1/4" liquid and 1/2" vapor linesets.
- All 7K, 9K, 12K and 15K models require 1/4" liquid and 3/8" vapor linesets.
Indoor and Outdoor Compatibility Chart
This chart shows the compatibility between various Haier indoor and outdoor units.
TEMPO 115V | TEMPO 230V | FLEXFIT | ARCTIC | FLEXFIT MULTI | ARCTIC MULTI | |
---|---|---|---|---|---|---|
INDOOR STANDARD HIGHWALL UNITS | ||||||
QS09WB1BEA | ✔ | |||||
QS12WB1BEA | ✔ | |||||
QS07WB2BEA | ✔ | |||||
QS09WB2BEA | ✔ | ✔ | ||||
QS12WB2BEA | ✔ | ✔ | ||||
QS15WB2BEA | ✔ | |||||
QS18WB2BEA | ✔ | ✔ | ||||
QS24WB2BEA | ✔ | ✔ | ||||
QS30WB2BEA | ✔ | |||||
QS36WB2BEA | ✔ | ✔ | ||||
INDOOR PREMIUM HIGHWALL UNITS | ||||||
QS09WP2BEA | ✔ | ✔ | ||||
QS12WP2BEA | ✔ | ✔ | ||||
QS18WP2BEA | ✔ | ✔ | ||||
QS24WP2BEA | ✔ | ✔ | ||||
INDOOR COMPACT CASSETTE UNITS | ||||||
US09CB2BEA | ✔ | |||||
US12CB2BEA | ✔ | |||||
US18CB2BEA | ✔ | |||||
INDOOR LARGE CASSETTE UNITS | ||||||
US24LB2BEA | ✔ | |||||
US30LB2BEA | ✔ | |||||
US36LB2BEA | ✔ | |||||
INDOOR CONSOLE UNITS | ||||||
US09FB2BEA | ✔ | |||||
US12FB2BEA | ✔ | |||||
US18FB2BEA | ✔ | |||||
INDOOR DUCTED UNITS | ||||||
US07MB2BEA | ✔ | |||||
US09MB2BEA | ✔ | ✔ | ||||
US12MB2BEA | ✔ | ✔ | ||||
US18MB2BEA | ✔ | ✔ | ||||
US24MB2BEA | ✔ | ✔ | ||||
US30MB2BEA | ✔ | ✔ | ||||
US36MB2BEA | ✔ | ✔ |
Ductless Accessories
Wind Baffles & Top Covers
Image shows a Haier outdoor unit with numbered callouts for accessory locations: 1. Front/Back Wind Baffle, 2. Side Wind Baffle, 3. Top Cover, 4. Outdoor Unit.
Recommended Accessories by Operating Conditions:
Operating Conditions | Front Wind Baffle | Side Wind Baffle | Back Wind Baffle | Top Cover |
---|---|---|---|---|
Low Ambient Cooling below 23°F (5°C) (server/mechanical room) | Required | Required | Required | Required |
Low Ambient Heating below 5°F (-15°C) | - | Strongly Recommended | Strongly Recommended | Strongly Recommended |
Unit installed on a flat roof or facing prevailing wind | Required | - | - | - |
Fabricated from durable 20 gauge G90 galvanized steel and engineered to provide optimal performance in cold, harsh climates. A front wind baffle is required for all climates when mounted on a flat roof or facing prevailing winds.
Outdoor Unit Accessory Compatibility Table
TEMPO 115V | TEMPO 230V | FLEXFIT | ARCTIC | ARCTIC MULTI | FLEXFIT MULTI | |
---|---|---|---|---|---|---|
FRONT OR BACK WIND BAFFLES | ||||||
UAWB15WA | ✔ | ✔ | ✔ | ✔ | ✔ | ✔ |
UAWB30WA | ✔ | ✔ | ✔ | ✔ | ✔ | ✔ |
UAWB31WA | ✔ | ✔ | ✔ | ✔ | ✔ | ✔ |
UAWB51WA | ✔ | ✔ | ✔ | ✔ | ✔ | ✔ |
SIDE WIND BAFFLES | ||||||
UASWB15WA | ✔ | ✔ | ✔ | ✔ | ✔ | ✔ |
UASWB30WA | ✔ | ✔ | ✔ | ✔ | ✔ | ✔ |
UASWB31WA | ✔ | ✔ | ✔ | ✔ | ✔ | ✔ |
UASWB51WA | ✔ | ✔ | ✔ | ✔ | ✔ | ✔ |
TOP COVERS | ||||||
UATC15WA | ✔ | ✔ | ✔ | ✔ | ✔ | ✔ |
UATC20WA | ✔ | ✔ | ✔ | ✔ | ✔ | ✔ |
UATC21WA | ✔ | ✔ | ✔ | ✔ | ✔ | ✔ |
UATC30WA | ✔ | ✔ | ✔ | ✔ | ✔ | ✔ |
UATC31WA | ✔ | ✔ | ✔ | ✔ | ✔ | ✔ |
UATC35WA | ✔ | ✔ | ✔ | ✔ | ✔ | ✔ |
UATC51WA | ✔ | ✔ | ✔ | ✔ | ✔ | ✔ |
5" CENTRAL CONTROLLER | ||||||
UACT32A | ✔ | ✔ | ✔ | ✔ | ✔ | ✔ |
Cassette Panels
Required for cassette indoor units; sold separately. Remote controller (WJ26X35394) is included with cassette panel.
- QACCP01WA Compact Cassette Panel: Fits Models: US09CB2BEA, US12CB2BEA, US18CB2BEA
- QALCP01WA Large Cassette Panel: Fits Models: US24LB2BEA, US30LB2BEA, US36LB2BEA
Supply Plenums
Supply plenums for ducted indoor models.
- UAPT0912A: Fits Models: US09MB2BEA, US12MB2BEA
- UAPT1824A: Fits Models: US18MB2BEA, US24MB2BEA
- UAPT3048A: Fits Models: US30MB2BEA, US36MB2BEA, US42MB2BEA, US48MB2BEA
Merv Return Air Filter Boxes
MERV return air filter boxes for ducted indoor models.
- UAMFB0912A: Fits Models: US09MB2BEA, US12MB2BEA
- UAMFB1824A: Fits Models: US18MB2BEA, US24MB2BEA
- UAMFB3048A: Fits Models: US30MB2BEA, US36MB2BEA, US42MB2BEA, US48MB2BEA
Refrigerant Detection Sensor (RDS)
UALS01A Ductless Refrigerant Detection Sensor. Note: See room sizing requirements to determine if the Refrigerant Detection Sensor (RDS) is required and needs to be purchased separately for highwall and cassette indoor units. RDS is factory-installed on console and ducted units.
Controllers
Controllers from Haier allow for convenient system command and comfort level management.
Wired Controller
QACT17B: Compatible with all indoor unit types. Features include power supply, controllable groups, modes, precise temperature control, fan speed adjustment, and more.
Remote Controllers
Available in multiple types for individual control, featuring Up/Down Louver Oscillating Control, Left/Right Louver Oscillating Control, Four-Way Cassette Air Supply Control, Child Lock, and more.
- WJ26X35393: Ships with standard highwalls.
- WJ26X35813: Ships with consoles.
- WJ26X35394: Ships with premium highwalls & cassette panels.
5" Central Controller
UACT32A: Features a 5" LED Touch Screen for intuitive navigation. Offers seamless integration of ductless and central HVAC systems. Manages up to 31 ductless zones and 1 central 24V HVAC zone.
Key Specifications:
- Power Supply: 24VAC*
- Max. IDUs Controllable: 31 + (1) 24VAC Central Zone
- Temperature Set Range: 60-86°F (16-30°C)
- Zones: Up to 31 Zones
- Modes: Cool, Heat, Auto, Dry, Fan
- Fan Speeds: Low, Med, High
- Humidity: Display in %
- Mode: Cool, Heat, Auto
- Fan Speed: Auto, Circulating, On
- Connectivity: WiFi/Alexa/Google Home
*If not connecting to 24V central HVAC system, a field supplied 24VAC transformer is needed.
Indoor Unit Accessory Compatibility Table
This table details the compatibility of indoor units with various accessories.
Model Number | Remote Controllers (WJ26X35393) | Remote Controllers (WJ26X35813) | Remote Controllers (WJ26X35394) | Wired Controller (QACT17B) | Refrigerant Detection Sensor (RDS) (UALS01A) |
---|---|---|---|---|---|
QS09WB1BEA | ✔ | ✔ | ✔ | ||
QS12WB1BEA | ✔ | ✔ | ✔ | ||
QS07WB2BEA | ✔ | ✔ | ✔ | ||
QS09WB2BEA | ✔ | ✔ | ✔ | ✔ | |
QS12WB2BEA | ✔ | ✔ | ✔ | ✔ | |
QS15WB2BEA | ✔ | ✔ | ✔ | ||
QS18WB2BEA | ✔ | ✔ | ✔ | ✔ | |
QS24WB2BEA | ✔ | ✔ | ✔ | ||
QS30WB2BEA | ✔ | ✔ | ✔ | ||
QS36WB2BEA | ✔ | ✔ | ✔ | ||
QS09WP2BEA | ✔ | ✔ | ✔ | ||
QS12WP2BEA | ✔ | ✔ | ✔ | ||
QS18WP2BEA | ✔ | ✔ | ✔ | ||
QS24WP2BEA | ✔ | ✔ | ✔ | ||
US09CB2BEA | ✔ | ✔ | ✔ | ||
US12CB2BEA | ✔ | ✔ | ✔ | ||
US18CB2BEA | ✔ | ✔ | ✔ | ||
QACCP01WA* | ✔ | ||||
US24LB2BEA | ✔ | ✔ | ✔ | ||
US30LB2BEA | ✔ | ✔ | ✔ | ||
US36LB2BEA | ✔ | ✔ | ✔ | ||
QALCP01WA* | ✔ | ||||
US09FB2BEA | ✔ | ✔ | ✔ | ||
US12FB2BEA | ✔ | ✔ | ✔ | ||
US18FB2BEA | ✔ | ✔ | ✔ | ||
US09MB2BEA | ✔ | ✔ | ✔ | ||
US12MB2BEA | ✔ | ✔ | ✔ | ||
US18MB2BEA | ✔ | ✔ | ✔ | ||
US24MB2BEA | ✔ | ✔ | ✔ | ||
US30MB2BEA | ✔ | ✔ | ✔ | ||
US36MB2BEA | ✔ | ✔ | ✔ | ||
US42MB2BEA | ✔ | ✔ | ✔ | ||
US48MB2BEA | ✔ | ✔ | ✔ |
*Cassette Panel. Key: ✔ = Included, Required, sold separately; ○ = Optional; sold separately. See Outdoor Unit Accessory Compatibility Table for 5" Central Controller compatibility.
Model Number Nomenclature
Ductless Outdoor Unit Nomenclature
This section explains the structure of Haier's ductless outdoor unit model numbers.
Format: 1 Q 18 T E 2 B E A 1
- Zones: 1 (Single Zone), 2/3/4 (Multi-Zone)
- Brand: Q (Haier)
- BTUs: e.g., 18 (18,000 BTU), 36 (36,000 BTU), 3036 (Cross Tonnage Product)
- Model Family: TE (Tempo), FF (FlexFit), RT (Arctic)
- Voltage: 1 (115V), 2 (230V)
- Refrigerant: B (R454B: Heat Pump)
- Model Design Year: E (2025), F (2026), G (2027)
- Minor Marketing Revision: A
- Engineering Digit: 1
Example: 1Q12TE2BEA: Haier 12K Tempo Single Zone
Ductless Indoor Unit Nomenclature
This section explains the structure of Haier's ductless indoor unit model numbers.
Format: Q S 09 W P 2 B E A 1
- Brand: Q (Haier), U (Universal)
- Type: S (Split)
- BTUs: e.g., 09 (9,000 BTU), 36 (36,000 BTU)
- IDU Type: W (Wall Mount), M (Mid-Static Ducted), F (Floor Console), C (Compact Cassette), A (One-Way Cassette), L (Large Cassette)
- IDU Sub-Type: B (Basic), P (Premium)
- Voltage: 1 (115V), 2 (230V)
- Refrigerant: B (R454B: Heat Pump)
- Model Design Year: E (2025), F (2026), G (2027)
- Minor Marketing Revision: A
- Engineering Digit: 1
Examples: QS09WB2BEA: Haier 9K Standard Highwall; US12MB2BEA: Universal 12K Ducted
Limited Warranty
Haier (GE Appliances) offers a 5-year limited warranty on parts. An extended 10-year limited warranty on parts is available with registration within 60 days of installation.
To register your equipment, visit: www.geappliancesairandwater.com/warranty
GE Appliances has a policy of continuous improvement and reserves the right to change materials and specifications without notice.