Lamborghini Caloreclima SMERALDO-C Series Product Fiche
Model: SMERALDO-C ODU S 18 / SMERALDO-C IDU FLOOR-CEILING18
Description | Symbol | Unit | Value |
---|---|---|---|
Sound power level at standard rating conditions (indoor) | LWA | [dB(A)] | 57 |
Sound power level at standard rating conditions (outdoor) | [dB(A)] | 65 | |
Refrigerant type | R32 | ||
GWP (1) | GWP | [kgCO2 eq.] | 675 |
SEER | SEER | 6,2 | |
Energy efficiency class in cooling | A++ | ||
Annual electricity consumption in cooling (2) | QCE | [kWh/a] | 305 |
Design load in cooling mode | Pdesignc | [kW] | 5,4 |
SCOP (average heating season) | SCOP/A | 4,0 | |
Energy efficiency class in heating (average season) | A+ | ||
Annual electricity consumption in heating (average season) (3) | QHE | [kWh/a] | 1400 |
Warmer heating season | Y | ||
Colder heating season | N | ||
Design load in heating mode (average season) | Pdesignh | [kW] | 4,0 |
Declared capacity at reference design condition (heating average season) | [kW] | 3,6 | |
Back up heating capacity at reference design condition (heating average season) | [kW] | 0,40 | |
Rated current for cooling | [A] | 6,0 | |
Rated current for heating | [A] | 6,6 | |
Rated capacity for cooling (Rated - min - max) | Prated cooling | [kW] | 5,3 2,7 5,9 |
Rated capacity for heating (Rated - min - max) | Prated heating | [kW] | 5,6 2,4 6,3 |
Rated power input for cooling (Rated - min - max) | PEER | [kW] | 1,5 0,7 2,0 |
Rated power input for heating (Rated - min - max) | PCOP | [kW] | 1,5 0,5 1,6 |
Rated Energy efficiency ratio | EERrated | 3,64 | |
Rated Coefficient of performance | COPrated | 3,71 | |
Voltage - Frequency - Phase no. | [V-Hz-Ph] | 220/240 50 1 |
(1) Refrigerant leakage contributes to climate change. Refrigerant with lower global warming potential (GWP) would contribute less to global warming than a refrigerant with higher GWP, if leaked to the atmosphere. This appliance contains a refrigerant fluid with a GWP equal to 675. This means that if 1 kg of this refrigerant fluid would be leaked to the atmosphere, the impact on global warming would be 675 times higher than 1 kg of CO2, over a period of 100 years. Never try to interfere with the refrigerant circuit yourself or disassemble the product yourself and always ask a professional.
(2) Energy consumption 305 kW/h per year based on standard test results. Actual energy consumption will depend on how the appliance is used and where it is located.
(3) Energy consumption 1400 kW/h per year based on standard test results. Actual energy consumption will depend on how the appliance is used and where it is located.
Contact details for obtaining more information: Ferroli S.p.A. Via Ritonda 78/A 37047 San Bonifacio (VR) Italy
Model: SMERALDO-C ODU S 24 / SMERALDO-C IDU FLOOR-CEILING24
Description | Symbol | Unit | Value |
---|---|---|---|
Sound power level at standard rating conditions (indoor) | LWA | [dB(A)] | 63 |
Sound power level at standard rating conditions (outdoor) | [dB(A)] | 69 | |
Refrigerant type | R32 | ||
GWP (1) | GWP | [kgCO2 eq.] | 675 |
SEER | SEER | 6,3 | |
Energy efficiency class in cooling | A++ | ||
Annual electricity consumption in cooling (2) | QCE | [kWh/a] | 394 |
Design load in cooling mode | Pdesignc | [kW] | 7,1 |
SCOP (average heating season) | SCOP/A | 4,1 | |
Energy efficiency class in heating (average season) | A+ | ||
Annual electricity consumption in heating (average season) (3) | QHE | [kWh/a] | 2015 |
Warmer heating season | Y | ||
Colder heating season | N | ||
Design load in heating mode (average season) | Pdesignh | [kW] | 5,9 |
Declared capacity at reference design condition (heating average season) | [kW] | 5,2 | |
Back up heating capacity at reference design condition (heating average season) | [kW] | 0,72 | |
Rated current for cooling | [A] | 9,0 | |
Rated current for heating | [A] | 8,7 | |
Rated capacity for cooling (Rated - min - max) | Prated cooling | [kW] | 6,8 3,2 8,0 |
Rated capacity for heating (Rated - min - max) | Prated heating | [kW] | 7,6 2,7 8,5 |
Rated power input for cooling (Rated - min - max) | PEER | [kW] | 2,1 0,8 2,7 |
Rated power input for heating (Rated - min - max) | PCOP | [kW] | 2,0 0,7 2,9 |
Rated Energy efficiency ratio | EERrated | 3,30 | |
Rated Coefficient of performance | COPrated | 3,85 | |
Voltage - Frequency - Phase no. | [V-Hz-Ph] | 220/240 50 1 |
(1) Refrigerant leakage contributes to climate change. Refrigerant with lower global warming potential (GWP) would contribute less to global warming than a refrigerant with higher GWP, if leaked to the atmosphere. This appliance contains a refrigerant fluid with a GWP equal to 675. This means that if 1 kg of this refrigerant fluid would be leaked to the atmosphere, the impact on global warming would be 675 times higher than 1 kg of CO2, over a period of 100 years. Never try to interfere with the refrigerant circuit yourself or disassemble the product yourself and always ask a professional.
(2) Energy consumption 394 kW/h per year based on standard test results. Actual energy consumption will depend on how the appliance is used and where it is located.
(3) Energy consumption 2015 kW/h per year based on standard test results. Actual energy consumption will depend on how the appliance is used and where it is located.
Contact details for obtaining more information: Ferroli S.p.A. Via Ritonda 78/A 37047 San Bonifacio (VR) Italy
Model: SMERALDO-C ODU S 36 / SMERALDO-C IDU FLOOR-CEILING36
Description | Symbol | Unit | Value |
---|---|---|---|
Sound power level at standard rating conditions (indoor) | LWA | [dB(A)] | 64 |
Sound power level at standard rating conditions (outdoor) | [dB(A)] | 70 | |
Refrigerant type | R32 | ||
GWP (1) | GWP | [kgCO2 eq.] | 675 |
SEER | SEER | 6,4 | |
Energy efficiency class in cooling | A++ | ||
Annual electricity consumption in cooling (2) | QCE | [kWh/a] | 574 |
Design load in cooling mode | Pdesignc | [kW] | 10,5 |
SCOP (average heating season) | SCOP/A | 4,1 | |
Energy efficiency class in heating (average season) | A+ | ||
Annual electricity consumption in heating (average season) (3) | QHE | [kWh/a] | 2937 |
Warmer heating season | Y | ||
Colder heating season | N | ||
Design load in heating mode (average season) | Pdesignh | [kW] | 8,6 |
Declared capacity at reference design condition (heating average season) | [kW] | 7,5 | |
Back up heating capacity at reference design condition (heating average season) | [kW] | 1,15 | |
Rated current for cooling | [A] | 13,6 | |
Rated current for heating | [A] | 15,0 | |
Rated capacity for cooling (Rated - min - max) | Prated cooling | [kW] | 10,1 2,7 11,4 |
Rated capacity for heating (Rated - min - max) | Prated heating | [kW] | 11,7 2,8 12,8 |
Rated power input for cooling (Rated - min - max) | PEER | [kW] | 3,1 0,9 4,3 |
Rated power input for heating (Rated - min - max) | PCOP | [kW] | 3,2 0,8 4,0 |
Rated Energy efficiency ratio | EERrated | 3,28 | |
Rated Coefficient of performance | COPrated | 3,71 | |
Voltage - Frequency - Phase no. | [V-Hz-Ph] | 220/240 50 1 |
(1) Refrigerant leakage contributes to climate change. Refrigerant with lower global warming potential (GWP) would contribute less to global warming than a refrigerant with higher GWP, if leaked to the atmosphere. This appliance contains a refrigerant fluid with a GWP equal to 675. This means that if 1 kg of this refrigerant fluid would be leaked to the atmosphere, the impact on global warming would be 675 times higher than 1 kg of CO2, over a period of 100 years. Never try to interfere with the refrigerant circuit yourself or disassemble the product yourself and always ask a professional.
(2) Energy consumption 574 kW/h per year based on standard test results. Actual energy consumption will depend on how the appliance is used and where it is located.
(3) Energy consumption 2937 kW/h per year based on standard test results. Actual energy consumption will depend on how the appliance is used and where it is located.
Contact details for obtaining more information: Ferroli S.p.A. Via Ritonda 78/A 37047 San Bonifacio (VR) Italy
Model: SMERALDO-C ODU S 36T / SMERALDO-C IDU FLOOR-CEILING36
Description | Symbol | Unit | Value |
---|---|---|---|
Sound power level at standard rating conditions (indoor) | LWA | [dB(A)] | 64 |
Sound power level at standard rating conditions (outdoor) | [dB(A)] | 68 | |
Refrigerant type | R32 | ||
GWP (1) | GWP | [kgCO2 eq.] | 675 |
SEER | SEER | 6,2 | |
Energy efficiency class in cooling | A++ | ||
Annual electricity consumption in cooling (2) | QCE | [kWh/a] | 592 |
Design load in cooling mode | Pdesignc | [kW] | 10,5 |
SCOP (average heating season) | SCOP/A | 4,0 | |
Energy efficiency class in heating (average season) | A+ | ||
Annual electricity consumption in heating (average season) (3) | QHE | [kWh/a] | 3010 |
Warmer heating season | Y | ||
Colder heating season | N | ||
Design load in heating mode (average season) | Pdesignh | [kW] | 8,6 |
Declared capacity at reference design condition (heating average season) | [kW] | 7,4 | |
Back up heating capacity at reference design condition (heating average season) | [kW] | 1,20 | |
Rated current for cooling | [A] | 6,3 | |
Rated current for heating | [A] | 5,5 | |
Rated capacity for cooling (Rated - min - max) | Prated cooling | [kW] | 10,1 2,7 11,8 |
Rated capacity for heating (Rated - min - max) | Prated heating | [kW] | 11,7 2,8 12,8 |
Rated power input for cooling (Rated - min - max) | PEER | [kW] | 3,1 0,9 4,3 |
Rated power input for heating (Rated - min - max) | PCOP | [kW] | 3,1 0,8 4,0 |
Rated Energy efficiency ratio | EERrated | 3,26 | |
Rated Coefficient of performance | COPrated | 3,73 | |
Voltage - Frequency - Phase no. | [V-Hz-Ph] | 220/240 50 3 |
(1) Refrigerant leakage contributes to climate change. Refrigerant with lower global warming potential (GWP) would contribute less to global warming than a refrigerant with higher GWP, if leaked to the atmosphere. This appliance contains a refrigerant fluid with a GWP equal to 675. This means that if 1 kg of this refrigerant fluid would be leaked to the atmosphere, the impact on global warming would be 675 times higher than 1 kg of CO2, over a period of 100 years. Never try to interfere with the refrigerant circuit yourself or disassemble the product yourself and always ask a professional.
(2) Energy consumption 592 kW/h per year based on standard test results. Actual energy consumption will depend on how the appliance is used and where it is located.
(3) Energy consumption 3010 kW/h per year based on standard test results. Actual energy consumption will depend on how the appliance is used and where it is located.
Contact details for obtaining more information: Ferroli S.p.A. Via Ritonda 78/A 37047 San Bonifacio (VR) Italy