Product Specifications
MODEL | C1BU1933 | |
---|---|---|
Power Supply | Input: AC 100-240V / 50/60Hz | Output: DC 12V / 1.0A |
Power Consumption | Min 2W ~ Max 6W | |
Dimension | 274 x 274 x 147 mm | |
Weight | 2.7 kg |
Special Features
By combining three-stage filtration technology, the Clair CUBE air purifier improves collection efficiency compared to existing single filtering systems. The CUBE delivers clean air from the back to the top, and the strong fan makes room air more pleasant quickly.
Innovative MAF Technology
The MAF (Magnetic Air Filtration) Technology revolutionizes the air purifier industry by combining plasma ionizers and E2F filters. This process traps viruses, pollens, bacteria, VOCs, and ultrafine dust with a radius of less than 0.1µm through electrostatic attraction.
UV-LED Sterilizer
Utilizing an indirect bactericidal method with violet blue light, the Clair CUBE offers excellent antibacterial capabilities without harming humans. It helps maintain filter performance by sterilizing and removing contaminants on the filter surface. The LED light can also serve as mood lighting.
Energy Efficiency
The Clair CUBE consumes very low power, using only 6 watts even in high-speed mode, saving costs and ensuring fresh air availability.
Easy Maintenance
Regular cleaning of the filter surface every 1-2 months ensures optimal filter effectiveness. Filter replacement is simple and recommended every 12 months.
Low Noise Level
Operating at less than 40dB even at high speed, the Clair CUBE can be used during study or sleep without disruption.
Attractive Design
The product's design harmonizes with any interior, featuring a soft feel with its curved corners.
Ideal Placement
The Clair CUBE's compact size and shape allow for easy installation and movement, providing fresh air consistently wherever it is placed.
Made in Korea
All models are manufactured in Korea to ensure customer reliability.
Product Components and Names
Product Components
- Main Body
- E2F Filter
- DC Adapter
- User Manual
Names of Each Part
Front
- Control Unit
- Air Outlet
- Front Cover (cannot remove)
Back
- Air Inlet
- Back Cover (can remove)
Installation Method
- Check the status of the product before installation.
- Disassemble the back cover from the body by grabbing and pulling the edge.
- Connect the product's body with the adapter.
- Slide the edge of the back cover into the groove of the body smoothly, ensuring the diagonal support engages.
- Plug into a power outlet and press the power button to operate.
- Ensure the back cover is not blocked by foreign objects to prevent air intake.
CAUTION! You must connect the DC Adapter to the product first and then connect to the outlet.
Operation Guide
Operation Method and Motion
Operation Mode | Operation Method | Operation Details | Button Indicator | LED Indicator |
---|---|---|---|---|
Level 1 | Press the power button once | Low speed mode | • | • |
Level 2 | Press the power button twice | Normal speed mode | •• | •• |
Level 3 | Press the power button 3 times | High speed mode | ••• | ••• |
OFF | Press the power button 4 times | OFF | ||
Power LED OFF | Press the power button for longer than 2 seconds (regardless of mode) | Power LED OFF | ||
Ionizer ON/OFF | Press the mode button for longer than 3 seconds | Ionizer ON/OFF | (m) | ion |
UV LED ON/OFF | Press the mode button once | UV LED ON/OFF | uv |
Recommended Installation Place
- Bed room
- Living room
- Children's room
- Study room
- Kitchen
- Studio
- Office
- Hospital room
Maintenance
How to Clean the Filter
- Turn the power off and unplug from the power outlet.
- Lay the product down with the back cover facing upwards.
- Hold the handle and disassemble the back cover.
- Remove dust from the E2F filter using a vacuum cleaner.
Caution! Make sure to start cleaning and filter management after turning off the power, unplugging from the outlet, and ensuring the fan has stopped. There is a danger of electric shock or other accidents if the filter is changed during operation.
How to Change the Filter
- Lay the product down with the back cover facing upwards.
- Hold the handle and disassemble the back cover.
- Hold the handles on both sides of the E2F filter and disassemble it from the main body.
- Replace with a clean, unused filter.
Caution for Maintenance
- Filters last for a maximum of 12 months, subject to change based on installation place and environmental conditions.
- Cleaning filters with water is not recommended as it may decrease purification ability due to reduced filter function.
- Do not touch the power cord with wet hands due to the risk of electric shock or other accidents.
- Do not pull on the power plug cable, as this may cause damage to the cable or injury.
- Do not use water or detergent when cleaning the body or filter, as it may cause stains or cracks on the surface.
- Do not place any objects on the product, as this may block the air inlet or outlet, causing malfunction or reduced purification ability.
- Keep children away from the product. Prevent them from climbing on it or inserting fingers or foreign objects into the outlet, as this could cause injury.
- Ensure water does not enter the product's interior, as this could cause fire or electric shock.
Caution for Safety
Caution for Power
- Do not change or extend the cable.
- Do not bend the power plug or pull it forcefully, as this may cause damage.
- Do not pull the power plug cable.
- Do not use damaged power cords, plugs, or loosened outlets.
- Do not use multiple devices simultaneously on a single power strip.
- Do not use the power plug near a heater.
- Use the rated adapter (DC 12V/1.0A rating).
- Pull out the power plug from the outlet before cleaning.
- Do not touch the power plug with wet hands.
- Pull out the plug when the product is not in use.
- Be careful to prevent infants from accessing or operating the product.
Failure to follow these instructions could lead to damage or injury from electric shock or fire.
Caution for Use and Placement
- Do not use the product in a location where gas may be leaked.
- Do not use the product in a place with industrial oil smoke or metallic dust.
- Do not use under direct sunlight, near heaters, or in humid conditions.
- Do not place on a slope or uneven surface.
- Install at least 20cm away from surrounding objects.
- Check for any obstacles blocking the air inlet or outlet.
- Do not move the product by holding only the back cover.
Failure to follow these instructions could lead to reduced purification ability, abnormal noise, or malfunction, and may cause damage or injury from electric shock or fire.
Caution for Operation
- Ensure the power plug is fully fixed and does not shake during operation.
- Do not block the air inlet and outlet with foreign matter.
- Do not use near hot objects like stoves or in fire-risk areas.
- Do not use the product on its side or back, and do not place objects on top.
- Do not use when the body and filter are separated.
- Do not use detergent to clean the product surface.
Failure to follow these instructions could lead to fire, malfunction, product damage, or reduced purification ability.
Caution for Filter
- Avoid direct contact with filters while in use, such as smelling or touching.
- For polluted filters, open the back cover and remove dust using only a vacuum cleaner.
- Cleaning with water is not recommended as it may decrease filter function.
- If the product is not used for extended periods, pollutants may collect in the filter. Seal the filter using a plastic cover for storage.
Failure to follow these instructions could lead to health problems or reduced functionality of the E2F filter.
Warranty Certificate
CLAIR, Inc. implements the warranty of the product as below according to the consumer indemnification regulation.
- The warranty period for Clair products is 1 year from the purchase date.
- Compensation and reception notice shall be made within 7 days from the application date, and repair and compensation shall be made within 14 days from the application date (excluding holidays and national holidays).
- The following cases are subject to paid repair:
- Failure due to the use of non-authentic components.
- Failure due to user negligence or arbitrary repair and modification.
- Failure due to non-implementation of matters defined in the user manual.
- Paid repair is available after the warranty period.
- Provide the warranty certificate in the event of repair application.
Customer service center 080-581-2917
Customer Information
Name | | |
---|---|
Address | | |
Tel. | | |
Mobile | | |
| | |
Product name | clair CUBE Air Purifier |
Model name | C1BU1933 |
Date of purchase | year month date |
Warranty period | 1 year from purchase date |
Manufacturing date | Indicated separately |
Manufacturer | CLAIR, Inc. |
Homepage | www.clair.kr |
Please safely store this certificate with your user manual as it cannot be re-issued.
Inquiry and Consulting
CLAIR, Inc.
2nd Floor, 148, Gangnam-daero, Seocho-gu, Seoul, Korea
TEL: +82.2.581.2918
FAX: +82.2.581.2919
WEB: www.clair.kr
E-MAIL: cs@clair.kr