HT9019 EN - 5 3. PREPARATION FOR USE 3.1. INITIAL The tester has been checked from a mechanical and electrical point of view before shipment. Every care has been taken to make sure that the instrument reaches you in perfect

man HT9019 En2-00xA


File Info : application/pdf, 16 Pages, 222.77KB

PDF preview unavailable. Download the PDF instead.

elektro-lijn-ht9019-hl-en
ENGLISH User manual

 Copyright HT ITALIA 2013

Release EN 2.00 - 18/04/2013

HT9019

Table of contents: 1. SAFETY PRECAUTIONS AND PROCEDURES ..........................................................2
1.1. Preliminary ........................................................................................................................ 2 1.2. During use ......................................................................................................................... 3 1.3. After use ............................................................................................................................ 3 1.4. Measuring (overvoltage) categories definitions................................................................. 3
2. GENERAL DESCRIPTION ...........................................................................................4
2.1. TRMS and Mean value measuring instruments ................................................................ 4 2.2. True Root Mean square value and crest factor definitions ................................................ 4
3. PREPARATION FOR USE ...........................................................................................5
3.1. Initial .................................................................................................................................. 5 3.2. Power supply..................................................................................................................... 5 3.3. Calibration ......................................................................................................................... 5 3.4. Storage.............................................................................................................................. 5
4. OPERATING INSTRUCTIONS.....................................................................................6
4.1. Instrument description ....................................................................................................... 6 4.1.1. Command description.........................................................................................................6 4.1.2. Alignment marks .................................................................................................................6
4.2. Function key description.................................................................................................... 7 4.2.1. H key ..................................................................................................................................7

4.2.2.

key ................................................................................................................................7

4.2.3. MODE key ..........................................................................................................................7

4.2.4. MAX/MIN key......................................................................................................................7

4.2.5. REL key ..............................................................................................................................7

4.2.6. PEAK key ...........................................................................................................................7

4.3. Functions of rotary switch description ............................................................................... 8

4.3.1. AC Voltage measurement...................................................................................................8

4.3.2. DC Voltage measurement ..................................................................................................9

4.3.3. Resistance measurement and Continuity test ..................................................................10

4.3.4. AC Current measurement.................................................................................................11

5. MAINTENANCE .........................................................................................................12

5.1. General informations ....................................................................................................... 12

5.2. Battery replacement ........................................................................................................ 12

5.3. Cleaning .......................................................................................................................... 12

5.4. End of life ........................................................................................................................ 12

6. TECHNICAL SPECIFICATIONS ................................................................................13

6.1. Characteristics................................................................................................................. 13

6.1.1. Safety ...............................................................................................................................14

6.1.2. General data .....................................................................................................................14

6.2. Environmental conditions ................................................................................................ 14

6.2.1. Climatic conditions............................................................................................................14

6.3. Standard accessories...................................................................................................... 14

7. SERVICE....................................................................................................................15

7.1. Warranty conditions......................................................................................................... 15

7.2. Service ............................................................................................................................ 15

EN - 1

HT9019
1. SAFETY PRECAUTIONS AND PROCEDURES
This clamp complies with IEC/EN61010-1. For your own safety and in order to avoid damaging the instrument, you're recommended to keep to the instructions contained in this manual and read carefully all the notes preceded by the symbol . Take extreme care for the following conditions while measuring:  Do not measure voltage or current in humid or wet environment.  Do not use the meter in presence of explosive gas (material), combustible gas
(material), steam or dust.  Insulate yourself from the object to be tested.  Do not touch exposed metal (conductive) parts such as test lead ends, sockets, fixing
objects, circuits, etc.  If you detect anomalies of testing end (metal part) and attachment of the meter such as
breakages, deformations, foreign substances, no display, etc., do not take any measurement.  Measuring voltage over 20V as it might cause human body electricity conduction. The followings symbols are used on meter and in this manual:
Caution: refer to the instruction manual. An incorrect use may damage the tester or its components
High Voltage ranger: electrical shock risk
Double insulated instrument
AC Voltage or Current
DC Voltage or Current
Ground reference
1.1. PRELIMINARY  This apparatus has been designed for use in an environment of pollution degree 2.
Indoor use.  It measures CURRENT and VOLTAGE on CAT IV 600V and CAT III 1000V plants. For
measurement categories please see § 1.4.  You must comply with the usual safety regulations aimed at protecting you against the
dangerous electric current and protecting the instrument against an incorrect operation.  Only the leads supplied with the instrument guarantee compliance with the safety
standards. They must be in good conditions and they must be replaced, if necessary, with an identical model.  Do not test or connect to any circuit whose voltage or current exceeds the specified overload protection.  Make sure that the batteries are installed correctly.  Before connecting the test probes to the installation, check that the function selector is positioned on the required measurement.  Make sure that the LCD and the range indicator show the same as the function desired.
EN - 2

HT9019
1.2. DURING USE Always keep to the instructions contained in this manual.
CAUTION
Non compliance with the CAUTIONs and/or the instructions may damage the tester and/or its components or injure the operator.
 Before changing the switch position, take off the clamp jaw from the tested conductor or the electrical circuit in order to avoid any accident
 When the clamp is connected to the circuits to be tested, never touch unused terminals  When testing resistors, do not add voltage. Although there is a protection circuit,
excessive voltage would cause malfunctioning  Before measuring current, remove the voltage-resistance test leads  When measuring current, any strong current close to the clamp jaw will affect the
accuracy  When measuring current, always put the tested conductor in the middle of the clamp
jaw in order to obtain a more accurate reading  If the reading value or the sign indication remains unchanged during the measurement,
check if the HOLD function is active
1.3. AFTER USE  Once the measurements are completed, turn the rotary switch to OFF.  If you expect not to use the clamp for a long time, remove the battery.
1.4. MEASURING (OVERVOLTAGE) CATEGORIES DEFINITIONS The norm EN 61010-1: Safety requirements for electrical equipment for measurement, control and laboratory use, Part 1: General requirements, defines what measuring category, usually called overvoltage category, is. On § 6.7.4: Measuring circuits, it says:
(OMISSIS)
circuits are divided into the following measurement categories:
 Measurement category IV is for measurements performed at the source of the lowvoltage installation.
Examples are electricity meters and measurements on primary overcurrent protection devices and ripple control units.
 Measurement category III is for measurements performed in the building installation.
Examples are measurements on distribution boards, circuit breakers, wiring, including cables, bus-bars, junction boxes, switches, socket-outlets in the fixed installation, and equipment for industrial use and some other equipment, for example, stationary motors with permanent connection to fixed installation.
 Measurement category II is for measurements performed on circuits directly connected to the low voltage installation..
Examples are measurements on household appliances, portable tools and similar equipment..
 Measurement category I is for measurements performed on circuits not directly connected to MAINS.
Examples are measurements on circuits not derived from MAINS, and specially protected (internal) MAINS-derived circuits. In the latter case, transient stresses are variable; for that reason, the norm requires that the transient withstand capability of the equipment is made known to the user.
EN - 3

HT9019

2. GENERAL DESCRIPTION
HT9019 meter can perform the herewith measurements:

 DC and AC TRMS Voltage up to 1000V  AC TRMS Current up to 1000A  Resistance and continuity test with buzzer  AC voltage detection with and without contact with integrated sensor

Each parameter can be selected by rotating the 7 positions switch. To abilitate the hold function the HOLD key is available. There are also the following keys: "MODE "MAX/MIN",
"REL", "PEAK" and " ". For their use please see § 4.2. The selected quantity appears on a LCD display with indication of measurement units and functions. An analogical bargraph it is also availbale

2.1. TRMS AND MEAN VALUE MEASURING INSTRUMENTS Safety testers for alternate parameters are divided into two big families:
 MEAN VALUE instruments: instruments which measure only the value of the wave at the fundamental frequency (50 or 60 Hz)
 TRUE ROOT MEAN SQUARE instruments, also defined as TRMS: instruments which measure the true root mean square value of the quantity under test.
In presence of a perfectly sinusoidal wave, both families provide identical results. In presence of distorted waves the readings are different. Mean value instruments provide only the value of the fundamental wave while True RMS instruments provide the value of the entire wave, including harmonics (within the passband of the instrument). Accordingly, if the same quantity is measured with both kinds of instruments, the measured values are identical only if the wave is purely sinusoidal. Should it be distorted, True RMS instruments provide higher values than medium value instruments.

2.2. TRUE ROOT MEAN SQUARE VALUE AND CREST FACTOR DEFINITIONS The current effective value is defined as follows: "In an interval of time equivalent to a period, an alternate current with effective value having an intensity of 1A, by passing on a resistor, disperses the same energy which would be dispersed in the same period of time by a direct current having an intensity of 1A". From this definition comes the numerical

 expression: G=

1

t0 T
g 2 (t)dt

The effective value is indicated as RMS (root mean square).

T t0

The Crest Factor is defined as the ratio between the Peak Value of a signal and its

effective value: CF (G)= G p . This value varies according to the waveform of the signal, G RMS

for a purely sinusoidal wave it's worth 2 =1.41. In presence of distortions the Crest Factor assumes higher values as long as the wave distortion is higher.

EN - 4

HT9019

3. PREPARATION FOR USE
3.1. INITIAL The tester has been checked from a mechanical and electrical point of view before shipment.

Every care has been taken to make sure that the instrument reaches you in perfect conditions.

However, it's advisable to make a rapid check in order to detect any damage which may have occurred in transit. Should this be the case, enter immediately the usual claims with the carrier.

Make sure that all the accessories listed in § 6.3 are contained in the package. In case of discrepancies contact Your dealer.

In case of returning of the tester please keep to the instructions given in § 7.

3.2. POWER SUPPLY The instrument is battery supplied. One 1x9V battery type NEDA 1604 IEC 6F22 JIS 006P is included in the package. Battery life: about 200 hours. When batteries are low, the

symbol "

" appears on the display. Replace them immediately, following the

instructions given in § 5.2.

The instrument disposes of the Auto Power OFF function (not disable) consisting in an

automatic switching off 15 minutes of idleness

3.3. CALIBRATION The tester complies with the technical features listed in this manual. Its performances are guaranteed for one year.

3.4. STORAGE In order to guarantee the accuracy of the measurements, after a period of storage under extreme environmental condition, wait for the necessary time so that the tester returns to normal measuring conditions (see § 6.2.1).

EN - 5

4. OPERATING INSTRUCTIONS
4.1. INSTRUMENT DESCRIPTION 4.1.1. Command description

HT9019
CAPTION: 1. Inductive clamp jaw 2. LED for AC voltage
detection 3. Jaw trigger 4. Function selector 5. HOLD / key 6. MODE, MAX/MIN,
Hz%, REL, PEAK function keys 7. LCD display 8. V input jack 9. COM input jack

Fig. 1: Instrument description 4.1.2. Alignment marks Put the conductor within the jaws on intersection of the indicated marks as much as possible (see Fig. 2) in order to meet the meter accuracy specifications
CAPTION: 1. Alignment marks 2. Conductor
Fig. 2: Alignment marks EN - 6

HT9019
4.2. FUNCTION KEY DESCRIPTION 4.2.1. H key By pushing "H" key the parameter measured value is frozen on the display and the symbol "HOLD" appears on it. This mode is disabled by pushing "H" key or moving the rotary switch.
4.2.2. key Keep pressed the "H" key for the backlight activation. This light could help the operator reading the display while he's measuring in dark sites. For sake of battery saving after 10 seconds the light is automiatically switched off.
4.2.3. MODE key By pushing MODE key the selection of resistance test and continuity test is possible in  position.
4.2.4. MAX/MIN key By pushing MAX/MIN key the parameter maximum and minimum values are measured. Both values are stored in memory and they can be shown cyclically when pressing "MIN MAX" key. The display shows the symbol linked to the selected function: "MAX" for maximum value, the symbol "MIN" for minimum value. This mode is activated on each measurement except for continuity test. This mode is disabled keeping pressed MAX/MIN key or moving the rotary switch.
4.2.5. REL key This key permits to perform the zeroing of value at display and a relative measurement of the parameter under test. By pushing REL key the instrument takes the actual parameter's value as on offset and performs a relative measurement. The relative value is displayed, it's calculated as actual value ­ offset value, the "REL" symbol is shown at display and the bargraph is disabled. This mode is disabled for resistance test, continuity test and with MAX/MIN mode activated. This mode is disabled pressing REL key again or moving the rotary switch
4.2.6. PEAK key By pushing PEAK key permits to activated the maximum peak measurement of AC current (calculated with response time <10ms). The "P" symbol is shown at display and the value is continuously updated by the meter. This mode is disabled pressing PEAK key again or moving the rotary switch
EN - 7

HT9019 4.3. FUNCTIONS OF ROTARY SWITCH DESCRIPTION 4.3.1. AC Voltage measurement
CAUTION
Maximum input for AC Voltage measurements is 1000Vrms. Do not take any voltage measurement exceeding this limit in order not to risk electrical shock or damaging the tester
Fig. 3: Taking AC voltage measurements 1. Rotate the switch on position 2. Insert the red test lead plug into V jack and the black test lead plug into COM jack
(Fig. 3) 3. Connect the two long ends of test leads to the desired circuit, then reading will be
displayed 4. When "O.L." symbol is displayed, the result exceeds the maximum value that the
instrument is capable of measuring 5. With meter switched on and rotary switch in each position move the integrated sensor
close to an AC source. The red LED turns on for detected voltage > 100V 6. For HOLD, MAX/MIN and REL features please refer to § 4.2
CAUTION
 Due to the high input impedance is possible that the meter performs the zero of the display taking longer
 The possible blinking values shown at display with open input terminals are not a problem of the meter and these values will not be added to the measured value EN - 8

HT9019 4.3.2. DC Voltage measurement
CAUTION
Maximum input for DC Voltage measurements is 1000V. Do not take any voltage measurement exceeding this limit in order not to risk electrical shock or damaging the tester.
Fig. 4: Taking DC voltage measurements 1. Rotate the switch on position 2. Insert the red test lead plug into V jack and the black test lead plug into COM jack
(Fig. 4) 3. Connect the two long ends of test leads to the desired circuit, then reading will be
displayed 4. When "O.L." symbol is displayed, the result is over the maximum value that the
instrument is able to measure 5. For HOLD, MAX/MIN and REL features please refer to § 4.2
CAUTION
 Due to the high input impedance is possible that the meter performs the zero of the display taking longer
 The possible blinking values shown at display with open input terminals are not a problem of the meter and these values will not be added to the measured value EN - 9

HT9019 4.3.3. Resistance measurement and Continuity test
CAUTION
Before taking any in circuit resistance measurement, remove power from the circuit to be tested and discharge all the capacitors.
Fig. 5: Taking Resistance measurement and Continuity test 1. Rotate the switch on  2. Insert the red test lead plug into V jack and the black test lead plug into COM jack
(Fig. 5) 3. Connect the two long ends of test leads to the desired circuit, then reading will be
displayed 4. Pushing MODE key and select continuity test. The symbol is shown at display.
Buzzer emits sound if the measured resistance value is less about 60 5. When "O.L." symbol is displayed, the result under test exceeds the maximum value
that the instrument is capable of measuring 6. For HOLD and MAX/MIN features please refer to § 4.2
EN - 10

HT9019 4.3.4. AC Current measurement
CAUTION
Make sure that all the test leads are disconnected from the meter terminals for current measurement.
Fig. 6: Taking AC current measurements 1. Rotate the switch on 60A, 600A, or 1000A position 2. Put the conductor to be tested inside to the center of clamp jaw to perform accurated
measurements. Consider the notches on jaws as reference (see Fig. 2). The reading will be displayed 3. When "O.L." symbol is displayed, the result exceeds the maximum value that the instrument is capable of measuring. Select an higher range 4. For HOLD, MAX/MIN, REL and PEAK features please refer to § 4.2
CAUTION
The possible blinking values shown at display with open input terminals are not a problem of the meter and these values will not be added to the measured value
EN - 11

HT9019

5. MAINTENANCE
5.1. GENERAL INFORMATIONS 1. This digital clamp meter is a precision instrument. Whether in use or in storage, please
do not exceed the specification requirements to avoid possible damages or dangers. 2. Do not place this meter at high temperatures or humidity or expose it to direct sunlight. 3. Be sure to turn off the meter after use. If you expect not to use the tester for a long
time, remove the battery in order to avoid leakages of battery liquid that would damage the internal parts.

5.2. BATTERY REPLACEMENT

When "

" appears on the display, replace the battery.

CAUTION
Only expert and trained technicians must perform this operation. Remove the test leads or the conductor under test before replacing the battery

1. Rotate the switch on OFF. 2. Remove the test leads or the objects to be tested. 3. Remove the screw from the battery cover, and detach the battery cover from the
bottom cover. 4. Remove the battery 5. Replace the battery with a new one same type (see § 6.1.2) 6. Replace the battery cover and screw 7. Use the appropriate battery disposal methods for Your area

5.3. CLEANING For cleaning the instrument use a soft dry cloth. Never use a wet cloth, solvents or water, etc.

5.4. END OF LIFE
CAUTION: this symbol indicates that equipment its accessories and battery shall be subject to a separate collection and correct disposal.

EN - 12

HT9019

6. TECHNICAL SPECIFICATIONS
6.1. CHARACTERISTICS Uncertainty is calculated as [% rdg + (number of dgt) x resolution]. It is referred to the following reference conditions: 18°C  28°C (65°F  83°F) with RH < 75%

DC Voltage (Autorange)

Range Resolution

Uncertainty

600.0mV

0.01mV

6.000V

0.001V

60.00V

0.01V

(1.0%rdg + 3dgt)

600.0V

0.1V

1000V

1V

The meter emits a continuous sound with VDC >1000V

Input impedance

Overload protection

10M

1000VDC/ACrms

AC Voltage TRMS (Autorange)

Range Resolution

Uncertainty

Input impedance

Bandwidh

Overload protection

6.000V

0.001V

(1.0%rdg+4dgt)

60.00V 600.0V

0.01V 0.1V

(50  60Hz) (3.5%rdg+5dgt)

10M

50-400Hz 1000VDC/ACrms

1000V

1V

(61  400Hz)

Integrated sensor for AC voltage detection: LED turn on for phase-earth voltage > 100V, 50/60Hz The meter emits a continuous sound with VDC >750V

Resistance and Continuity test (Autorange)

Range Resolution

Uncertainty

600.0

0.1

6.000k

0.001k

60.00k

0.01k

(1.0%rdg+5dgt)

600.0k

0.1k

6.000M 0.001M

60.00M

0.01M (2.0%rdg.+10dgt)

Test current of continuity test: < 0.35mA

Buzzer  60

Overload protection 600VDC/ACrms

AC TRMS Current

Range Resolution Uncertainty (*) Bandwidh

60.00A

0.01A

(2.8%rdg+12dgt)

600.0A

0.1A

(2.8%rdg+8dgt) 50  60Hz

1000A

1A

(3.0%rdg+8dgt)

60.00A

0.01A

(4.5% rdg+10dgt)

600.0A 1000A

0.1A 1A

(5.0%rdg+10dgt) 61  400Hz

PEAK function: response time <10ms (*) Referred to cable inside to the center of clamp jaws. Position sensitivity: 2.0%rdg

Overload protection 1000AACrms

EN - 13

HT9019

6.1.1. Safety Comply with: Insulation: Pollution degree: Max height of use: Installation category:

IEC/EN61010-1 double insulation 2 2000m (6562 ft) CAT IV 600V, CAT III 1000V to ground,

6.1.2. General data Mechanical characteristics Dimensions (L x W x H): Weight (including battery): Max conductor size:
Supply Battery type: Low battery indication: Battery life: Auto Power OFF:
Display Characteristics:
Sample rate: Conversion mode:

252 x 88 x 44mm ; 10 x 3 x 2 in 402g (14 ounces) 45mm (2 in)

1x9V battery NEDA 1604 IEC 6F22 JIS 006P.

"

" is displayed when the battery level is low

about 200 hours

after 15 minutes of idleness (not disabled)

4 LCD (max 6000 counts), decimal point, unit symbol indication, bargraph and backlight 2 times/sec TRMS

6.2. ENVIRONMENTAL CONDITIONS

6.2.1. Climatic conditions

Reference temperature:

18°C  28°C (65°F  83°F)

Operating temperature:

5 ÷ 40 °C (41°F  104°F)

Operating humidity:

< 75%RH

Storage temperature:

-20 ÷ 60 °C (-4°F  140°F)

Storage humidity:

< 80% RH

This product conforms to the prescriptions of the European directive on low voltage 2006/95/EEC and to EMC directive 2004/108/EEC
6.3. STANDARD ACCESSORIES  Test leads ­ Code 4413-2  Carrying bag  User manual  Battery

EN - 14

HT9019
7. SERVICE
7.1. WARRANTY CONDITIONS This equipment is guaranteed against material faults or production defects, in accordance with the general sales conditions. During the warranty period (one year), faulty parts may be replaced. The manufacturer reserves the right to decide either to repair or replace the product.
In case of returning of the instrument, all transport charges must be paid by the customer. The instrument must be accompanied by a delivery note indicating the faults or reasons of returning. The returned tester must be packed in its original box. Any damage occurred in transit because of lack of original packaging will be debited to the customer. The manufacturer is not responsible for any damage against persons or things. Accessories and batteries are not covered by warranty.
The warranty won't be applied to the following cases:  faults due to improper use of the equipment  faults due to combination of the tester with incompatible equipment.  faults due to improper packaging.  faults due to servicing carried out by a person not authorized by the company.  faults due to modifications made without explicit authorisation of our technical
department.  faults due to adaptation to a particular application not provided for by the definition of
the equipment or by the instruction manual.
The contents of this manual cannot be reproduced in any form without our authorization.
Our products are patented. Our logotypes are registered. We reserve the right to modify characteristics and prices further to technological developments.
7.2. SERVICE If the equipment doesn't work properly, before contacting the SERVICE, test the batteries, the test leads, etc., and change them if necessary. If the equipment still doesn't work, make sure that your operating procedure complies with the one described in this manual. In case of returning of the instrument, all transport charges must be paid by the customer. The instrument must be accompanied by a delivery note indicating the faults or reasons of returning. The returned tester must be packed in its original box. Any damage occurred in transit because of lack of original packaging will be debited to the customer.