Instruction Manual for SIEMENS models including: 536-994B Room Temperature Sensor Flush Mount 10K Ohm, 536-994B, Room Temperature Sensor Flush Mount 10K Ohm, Sensor Flush Mount 10K Ohm, Flush Mount 10K Ohm, Mount 10K Ohm

High/low voltage seperator

Siemens Building Technologies

Installation Instructions

Siemens 536-994B Room Temperature Sensor, Flush Mount, 10K Ohm, White - Adaptive HVAC Supplies

Siemens 536-994A Room Temperature Sensor, Flush Mount, 10K Ohm, Beige - Adaptive HVAC Supplies


File Info : application/pdf, 1 Pages, 72.14KB

PDF preview unavailable. Download the PDF instead.

A6V10074746 Flush-Mount-Room-Temperature-Sensor-Installation-I en
Installation Instructions
Document No. 538-048 January 2, 2008

Flush Mount Room Temperature Sensor

Product Description

These Flush Mount Room Temperature Sensors are self-contained, non-intrusive and tamper-resistant. They are available in both 10K ohm and 100K ohm thermistor, and 1K ohm Platinum (375 ) RTD.

Product Numbers

536-784 536-994 544-374

100K ohm Thermistor 10K ohm Thermistor 1000 ohm Platinum (375 ) RTD

Installation
1. Connect the field wires to the sensor lead wires using the wire nuts provided. See Figure 1.

Required Tools
· 5/64 hex head Allen wrench · Wire strippers/cutters
Expected Installation Time
5 minutes
Prerequisites
· 2-inch × 4-inch utility box, installed per Mounting Instructions.
· Field wiring pulled to the utility box.
Mounting Instructions (Utility Box)
Select a location for the sensor based on the following guidelines:
· Locate sensor near the middle of an inside wall, approximately five feet (1.5 m) from the floor.
· Do not mount: - in direct sunlight or drafts, or near diffusers. - behind doors or drapes. - on walls used as return air plenums.
Item Number 538-048, Rev DA

Figure 1. Installing the Sensor.
2. Push all wires into the utility box. 3. Using the hex head Allen wrench, mount the
sensor assembly to the utility box with the special security screws mounted on the sensor. 4. Connect the field wires to the appropriate controller. See Figure 2. The installation is now complete.
Figure 2. Wiring.
NOTE: 1. Some Siemens Building Technologies controllers may require a shield termination.
2. For individual panel wiring details, see the appropriate hardware manual.

Information in this publication is based on current specifications. The company reserves the right to make changes in specifications and models as design improvements are introduced. Other product or company names mentioned herein may be the trademarks of their respective owners. © 2008 Siemens Building Technologies, Inc.

Siemens Building Technologies, Inc. 1000 Deerfield Parkway Buffalo Grove, IL 60089-4513 U.S.A.

Your feedback is important to us. If you have comments about this document, please send them to SBT_technical.editor.us.sbt@siemens.com

Document No. 538-048 Country of Origin: US
Page 1 of 1



References

GPL Ghostscript 9.55.0