Kenmore Elite SSV | Quick Clean™ Cylonic Multi-Vac

Model/Modelo: DS6025

Vacuum Cleaner Help Line: 1-877-531-7321

Hours: 8:00am-5:00pm EST, M-F

Website: www.kenmore.com

Kenmore and the Kenmore logo are registered trademarks of KCD IP, LLC and/or Sears Brands, LLC and are used under license by Cleva North America, Inc. All Rights Reserved.

Before Using Your New Vacuum Cleaner

Read this Use & Care Guide. It will help you assemble and operate your new Kenmore Elite vacuum cleaner in the safest and most effective way.

For more information about vacuum cleaner care and operation, call the Vacuum Cleaner Help Line at 1-877-531-7321. You will need the complete model and serial numbers when requesting information.

Your vacuum cleaner's model and serial numbers are located on the Model and Serial Number Plate. Use the space below to record the model number and serial number of your new Kenmore Elite vacuum cleaner.

Model No.: ____________________________________________

Serial No.: ____________________________________________

Date of Purchase: ______________________________________

Keep this book and your sales check (receipt) in a safe place for future reference.

Packing List

Your KENMORE ELITE CORDLESS VACUUM CLEANER is packaged with the following parts and components assembled separately in the carton:

Important Safety Instructions

WARNING!

READ ALL INSTRUCTIONS IN THIS GUIDE BEFORE ASSEMBLING OR USING YOUR VACUUM CLEANER. To reduce the risk of fire, electrical shock, injury to persons or damage when using your vacuum cleaner, follow all safety precautions listed below.

NOTICE

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions.

  1. This device may not cause harmful interference.
  2. This device must accept any interference received, including interference that may cause undesired operation.

Disposal

This product contains a detachable Lithium-ion battery pack formulated from environmentally sensitive materials. This product must be disposed of properly with due care for the environment. Do not dispose of product with household garbage.

Consult your local waste authority for information regarding available recycling or disposal options.

SAVE THESE INSTRUCTIONS

Household use only.

Warranty

KENMORE LIMITED WARRANTY

FOR ONE YEAR from the date of sale this product is warranted against defects in material or workmanship.

WITH PROOF OF SALE a defective product will be replaced free of charge.

The Kenmore brand is used under license. Direct all claims for warranty service to: Cleva North America, Inc., 1-877-531-7321

This warranty does not cover filters or belts, which are expendable parts that can wear out from normal use within the warranty period.

This warranty applies for only 90 days from the date of sale if this product is ever used for other than private household purposes.

This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.

Cleva North America, Inc., Greenville SC 29607

Parts and Features

It is important to know your vacuum cleaner's parts and features to assure its proper and safe use. Review these before using your vacuum.

REPLACEMENT PARTS

Item Part No.
HEPA Filter+Two Foam Filters 561025105
Charging Adapter 561025120
25V Battery Pack 561025119
Battery Charger Base 561030101
Wall Mountable Charging Dock 561026107
Bare Floor Nozzle Brush Roll 561030102

To order a replacement part call 1-844-202-9924

Component Descriptions

Hand Vacuum with Battery Inserted: The main handheld unit containing the motor, dustbin, and battery.

Charger Adapter: The power adapter that plugs into a wall outlet.

Battery Pack: The rechargeable lithium-ion battery.

Battery Charger Base: A standalone base where the battery pack can be charged separately.

Bare Floor Motorized Nozzle: The cleaning head designed for hard floors, featuring a motorized brush roll.

Pet PowerMate™: An accessory tool, likely for pet hair removal or upholstery cleaning.

Accessory Bag: A bag for storing included tools.

Wall Mountable Charging Dock: A unit that mounts to the wall, allowing the entire vacuum to be charged while docked.

Wand: An extension tube that connects the hand vacuum to the floor nozzle.

Combination Tool: A versatile accessory that can function as a crevice tool or a dusting brush.

Accessory Tool Usage

All included accessory tools can be inserted into either the hand vacuum or wand. You will hear a click if inserted correctly.

Combination Tool

The combination brush can be used as a crevice tool or as a dusting brush. To use as a dusting brush, simply squeeze the buttons on the side of the tool and shift brush to expose the bristles.

Pet PowerMate™

Suggested use for optimal control is with Pet PowerMate inserted into the hand vacuum. Hold at an angle so rotating brush sits flush to cleaning surface.

NOTE: Always be sure that contact surfaces of accessory tools are clean before use.

Assembly Instructions

Before assembling the vacuum cleaner, check the PACKING LIST (Page 2). Use this list to verify that you have received all the components of your new Kenmore Elite SSV QuickClean Cyclonic Multi-Vac.

  1. Insert the wand into the hand vacuum until you hear a click. (Diagram shows wand sliding into the top of the hand vacuum, with a 'Click' indicator.)
  2. Insert the motorized nozzle into the wand until you hear a click. (Diagram shows the floor nozzle sliding onto the bottom of the wand, with a 'Click' indicator.)
  3. Slide the battery pack along the slots under the hand vacuum handle into the vacuum. (Diagram shows battery pack sliding into the handle area, with a 'Click' indicator.)
  4. Use the 2 screws provided to mount the charging dock on the wall, but not to drywall only. Secure the screws to a stud. Mount at a recommended height of 59" and no less than 44" above the floor. Ensure that no plumbing or electrical cables, wires or ductwork are located directly behind the mounting area. (Diagram shows wall mounting dimensions and screw placement.)
  5. Insert the battery charger base into the charging dock. (Diagram shows the base sliding into the wall mount dock.)
  6. Charge the unit for 3.5 hours before using the vacuum for the first time. (Diagram shows the fully assembled vacuum standing upright, connected to the wall mount charger.)

Charging

WARNING

Before charging make sure unit is in the OFF position.

This vacuum cleaner has two charging options:

Charging on Wall Mountable Charging Dock

The charger adapter output plug will fit into the battery charger base port only one way. Insert the charging adapter plug into the port on the side of the charging base.

Plug the adapter into a wall outlet. Place the vacuum on the hook of the charging dock until the blue LED battery indicator starts to flash.

LED Battery Indicator: The battery requires approximately 3.5 hours of charging to regain full capacity. While the unit is charging, the first bar of the battery indicator starts to flash. When the first bar is fully charged, the second one will start to flash while the first bar stays illuminated. The sequence continues repeating while the vacuum is charging. When battery is fully charged, all four power level bars will flash 10 times, then turn off.

NOTE: If the LED does not illuminate when charging, ensure that the charging adapter is plugged in properly to the wall outlet and port on battery charger base. Also, ensure that the unit is properly seated in the charger dock with the pins contacting the charging plates of the vacuum head.

For better battery performance, always store the unit on the charging dock when it is not in use.

Charging on Battery Charger Base

Remove battery pack from hand vacuum by pressing the two release buttons on the sides of the battery pack while sliding backwards.

If inserted, remove battery charger base from the charging dock by pressing down on release button and sliding outwards.

Insert the battery pack along the slots on the charger base until you hear a click.

Ensure the charging adapter is plugged into a wall outlet. The blue LED will start blinking indicating the battery is charging.

The battery requires approximately 3.5 hours of charging to regain full capacity.

Once the LED indicator shows a continuous blue light, the battery is fully charged.

Detach the battery pack from the charger base by holding down the release button and sliding the battery outwards. Insert pack back into vacuum.

Operating Instructions

CAUTION

Moving parts! To reduce the risk of personal injury, DO NOT touch the brush roll when vacuum is on. Contacting the brush roll while it is rotating can cut, bruise or cause other injuries. Always turn off before servicing. Use caution when operating near children or pets.

CONTROL BUTTONS

The power slider button is located above the handle of the hand vacuum. The SSV has two-speed controls, low and high.

Power Slider:

Battery Power Level Indicators:

The Battery Power Level indicators light up blue to give you an idea of how much battery power remains at any given time.

(Diagram representation: Four battery bars labeled 25%, 50%, 75%, 100%)

VACUUM OPERATION

CAUTION

Operate appliance at room temperature 39.2 - 104°F (4 - 40°C) in order to ensure its safety and normal function.

Before cleaning, connect the bare floor nozzle to the wand. Then connect the hand vacuum to the wand.

Slide the power switch to the desired power level (Low or High). Once turned on, the battery level indicator will be lit.

To turn the vacuum off, slide the power switch down to the bottom.

NOTE: When battery power decreases to about 10% remaining, the last bar of the battery level indicator will start flashing. The flashing will continue until the unit is placed on the charging dock or is completely out of battery power.

Cleaning with the Hand Vacuum

Easily clean messes on furniture, upholstery, stairs, and other hard-to-reach areas with one of the two included accessory tools.

  1. To detach the hand vacuum, press the release button and pull the hand vacuum from the wand. (Diagram shows hand vacuum detaching from wand via a release button.)
  2. Insert an accessory tool into the end of the hand vacuum until you hear a click.
  3. When finished cleaning, turn power OFF and press release button to remove tool. If desired, place the tool into the accessory bag for easy storage.

Vacuum Maintenance and Care

CAUTION

To reduce the risk of electric shock, turn power off and remove the unit from the charging dock before any maintenance.

EMPTYING DUST CUP AND FILTER CLEANING

For best performance, empty dust cup after every use or once dust reaches max fill line. Never operate vacuum cleaner without dust cup and filter in place.

Before emptying the dust cup, ensure the vacuum is turned off.

  1. Position dust cup area of vacuum over a waste receptacle. Press down on the dust cup release button to open dust cup lid and allow cup contents to drop into waste receptacle. (Diagram shows dust cup release button.)
  2. If necessary, clean off hair and other debris wrapped around the pre-filter. Rotate pre-filter clockwise to remove from dust cup chamber for cleaning. (Diagram shows pre-filter removal.)
  3. Insert pre-filter back into chamber and rotate as shown below to lock. Close dust cup lid until you hear a click. (Diagram shows pre-filter insertion and dust cup closing.)

After repeated use, it is necessary to wash the HEPA filter and 2 foam filters clean of accumulated dust.

WARNING: Do not operate vacuum cleaner without filters in place.

  1. Open the filter cover on top of hand vacuum by squeezing the two release buttons inward and lifting off. Remove HEPA filter and small foam filter from forward area of filter chamber. Remove round foam filter from inside of HEPA. (Diagrams show filter removal steps.)
  2. Brush loose debris from HEPA filter and then rinse with warm water. Rinse and gently squeeze dry the foam filters. Set all filters aside and allow to air dry.

IMPORTANT: The HEPA and 2 foam filters must dry completely before reuse.

  1. Place the small foam filter back into the front of the filter chamber.
  2. Place the round foam filter into the center of the HEPA filter. Insert the HEPA filter into filter chamber and reattach filter cover. (Diagrams show filter reassembly.)

To Remove and Re-assemble Brush Roll for Manual Cleaning:

  1. Ensure the vacuum is OFF.
  2. Turn unit to the side to access the brush roll. To unlock brush roll, grab metal ring and rotate the arrow to the unlocked symbol position. With nozzle facing down, pull out the brush roll from the housing. (Diagram shows brush roll removal with metal ring and arrow.)
  3. Clean off debris and anything wrapped around the brush. Use a screwdriver wrapped with a clean cloth to clean the left and right surface of the inner air-path.
  4. Align the brush roll to the brush drive and slide the brush roll into the housing. You may need to rotate the roll slowly to make sure the roll matches the drive gear, then the roll can be completely inserted. Rotate the brush to ensure it turns easily before turning vacuum ON.
  5. Lock the brush roll in place by rotating the arrow using the metal ring from the unlocked symbol position to the locked position.
  6. Place the metal ring in the slot.

Brush Roll Reset

If the brush roll is blocked or overloaded, the unit will automatically stop power. Switch the unit to the OFF position and remove the obstruction.

Hose Blockage Removal

  1. To clean out the hose, press the release button on the wand, and pull the motorized nozzle away from the wand. (Diagram shows nozzle detaching from wand.)
  2. Carefully remove any debris or blockage from the inside of the hose. Reattach the motorized nozzle onto the wand.
  3. Once the blockage is removed, start the vacuum to ensure air flow through the hose.

CAUTION! Do not use scissors or other sharp objects to remove a blockage from the hose.

Troubleshooting

Review the table for solutions to minor performance problems. Any service needed, other than maintenance described in this Use & Care Guide, should be performed by a qualified service dealer.

WARNING

Disconnect electrical supply before performing maintenance to the vacuum cleaner. Failure to do so could result in electrical shock or personal injury.

PROBLEM POSSIBLE CAUSE SOLUTION
A. Vacuum will not turn on. 1. Battery may be depleted.
2. Wrong charger being used.
3. The motorized brush roll is jammed.
4. Battery not installed completely.
1. Charge the battery as instructed on page 11.
2. Be sure to use only the charger supplied with your product.
3. Remove obstruction. Follow instructions on page 15.
4. Be sure battery is correctly aligned and completely installed into hand vacuum.
B. Battery charge indicator does not illuminate. 1. Battery may be depleted.
2. Charge adapter is not plugged in.
3. The battery charger base is not fully inserted into charging dock.
4. Debris accumulated on the metal charger contacts on hand vacuum, main body, or battery contacts.
5. The electrical outlet is not working.
6. The temperature of cell surface is overheated.
1. Charge the battery as instructed on page 11.
2. Be sure the charger adapter is plugged completely into the outlet and the charging base port.
3. Be sure the battery charger base is completely inserted into charging dock.
4. Be sure the metal pins on the dock are accurately lined up with the metal charging contacts on the hand vacuum and no debris has accumulated.
5. Ensure that the outlet is supplying power to the charger.
6. Charge the battery after the battery has cooled down to the normal temperature (45 minutes).
C. Motorized nozzle brushroll not turning. 1. Brush roll is jammed.
2. Brush roll is not installed properly.
3. Nozzle motor is spinning, but the brush roll is not rotating.
1. Remove obstruction. Follow instructions on page 15.
2. Remove and reinstall brush roll. See instructions on page 15.
3. Belt is broken.
D. Vacuum not picking up or suction power is weak. 1. Dust cup is full.
2. Filter needs cleaning.
3. Filter needs to be replaced.
4. Battery may be depleted.
1. Empty dust cup.
2. Follow filter cleaning instructions on page 14.
3. To purchase parts call 1-844-202-9924.
4. Charge the battery as instructed on page 11.
E. Dust escapes from vacuum. 1. Filter is missing or installed incorrectly.
2. Filter is damaged and needs to be replaced.
3. Pre-filter is missing or is installed incorrectly.
1. Check filter for correct installation. See page 14.
2. To purchase filter call 1-844-202-9924.
3. Reinstall correctly as instructed on page 14.
F. Vacuum turns off on its own. 1. Battery may be depleted.
2. The battery is overheated.
3. The brush motor is overloaded or brush roll is blocked.
4. The suction inlet or hose is blocked or sealed.
5. Excessive loading on brush roll brush.
1. Charge the battery as instructed on page 11.
2. Charge the battery after the battery has cooled down to the normal temperature (45 minutes).
3. Remove obstruction from brush, cool down the unit to ambient temperature, then re-start. Follow instructions on page 15.
4. Remove obstruction then re-start.
5. Turn vacuum off and re-start.

Contact Information

For additional assistance, refer to the Troubleshooting section of the Use & Care Guide or call the Vacuum Cleaner Help Line:

Kenmore Vacuum Cleaner Help Line:

1-877-531-7321

8:00 am – 5:00 pm ET M-F

PDF preview unavailable. Download the PDF instead.

DS6025 (10440) Manual GB-ES V2 20191220 Adobe InDesign CC 13.1 (Windows) Adobe PDF Library 15.0

Related Documents

Preview Kenmore Elite DS6025 SSV Quick Clean Cordless Vacuum Cleaner Use & Care Guide
This comprehensive guide provides instructions for assembling, operating, charging, maintaining, and troubleshooting the Kenmore Elite DS6025 SSV Quick Clean Cordless Vacuum Cleaner. Includes safety warnings, parts list, and warranty information.
Preview Kenmore Elite SSV Complete Cyclonic Multi-Vac DS6028 Use & Care Guide
Comprehensive use and care guide for the Kenmore Elite SSV Complete Cyclonic Multi-Vac vacuum cleaner (Model DS6028), including safety instructions, parts, assembly, operation, maintenance, and troubleshooting.
Preview Kenmore Elite SSV Quick Clean Cylonic Multi-Vac DS6025 Use & Care Guide
Comprehensive guide for the Kenmore Elite SSV Quick Clean Cylonic Multi-Vac DS6025, covering safety instructions, parts, assembly, operation, maintenance, and troubleshooting.
Preview Kenmore Intuition BU4021 Bagged Upright Vacuum Cleaner Use & Care Guide
This Use & Care Guide provides essential information for the Kenmore Intuition BU4021 Bagged Upright Vacuum. It covers assembly, operation, safety, maintenance, and troubleshooting to help users operate the vacuum cleaner safely and effectively. Visit www.kenmore.com for more details.
Preview Kenmore Robot Vacuum Cleaner 31510 Use & Care Guide
Comprehensive guide for the Kenmore Robot Vacuum Cleaner Model 31510, covering setup, operation, maintenance, safety precautions, and troubleshooting tips for optimal performance.
Preview Kenmore BC4002 Canister Vacuum Cleaner Use and Care Guide
User manual and care guide for the Kenmore BC4002 Canister Vacuum Cleaner. Provides detailed instructions on assembly, safe operation, maintenance, troubleshooting, and parts replacement.
Preview Kenmore Intuition BU4022 Bagged Upright Vacuum Cleaner Use & Care Guide
Comprehensive Use & Care Guide for the Kenmore Intuition BU4022 Bagged Upright Vacuum Cleaner, covering assembly, operation, safety, maintenance, and troubleshooting.
Preview Kenmore Bagless Lift-Up Upright Vacuum with Hair Eliminator® Brushroll Use & Care Guide
This guide provides essential information for the Kenmore Bagless Lift-Up Upright Vacuum with Hair Eliminator® Brushroll (Model DU4399). It covers assembly, safe operation, maintenance, and troubleshooting to ensure optimal performance and longevity for household use.