Single Phase Hybrid Inverter
SUN-12/14/16/18K-SG01LP1-EU-AM3-P
The Deye Single Phase Hybrid Inverter series offers advanced solutions for solar energy management. These inverters are designed for both on-grid and off-grid operations, providing flexibility and reliability.
Key Features:
- Colorful touch LCD with IP65 protection degree.
- AC coupling capability to retrofit existing solar systems.
- Supports parallel operation of up to 16 units for increased capacity.
- Maximum charging/discharging current of 350A.
- Configurable 6 time periods for battery charging/discharging.
- Capability to store energy from diesel generators.
Technical Data
Model | SUN-12K-SG01LP1-EU-AM3-P | SUN-14K-SG01LP1-EU-AM3-P | SUN-16K-SG01LP1-EU-AM3-P | SUN-18K-SG01LP1-EU-AM3-P |
---|---|---|---|---|
Battery Input Data | ||||
Battery Type | Lead-acid or Lithium-ion | |||
Battery Voltage Range (V) | 40-60 | |||
Max. Charging Current (A) | 220 | 250 | 290 | 350 |
Max. Discharging Current (A) | 220 | 250 | 290 | 350 |
Charging Strategy for Li-ion Battery | Self-adaption to BMS | |||
Number of Battery Input | 2 | |||
PV String Input Data | ||||
Max. PV Access Power (W) | 24000 | 28000 | 32000 | 36000 |
Max. PV Input Power (W) | 19200 | 22400 | 25600 | 28800 |
Max. PV Input Voltage (V) | 500 | |||
Start-up Voltage (V) | 125 | |||
MPPT Voltage Range (V) | 150-425 | |||
Rated PV Input Voltage (V) | 370 | 370 | 370 | 370 |
Max. Operating PV Input Current (A) | 36+36+36 | 36+36+36 | 36+36+36 | 36+36+36 |
Max. Input Short-Circuit Current (A) | 54+54+54 | 54+54+54 | 54+54+54 | 54+54+54 |
No. of MPP Trackers/ No. of Strings MPP Tracker | 3/2+2+2 | 3/2+2+2 | 3/2+2+2 | 3/2+2+2 |
AC Input/Output Data | ||||
Rated AC Input/Output Active Power (W) | 12000 | 14000 | 16000 | 18000 |
Max. AC Input/Output Apparent Power (VA) | 13200 | 15400 | 17600 | 19800 |
Rated AC Input/Output Current (A) | 54.6/52.2 | 63.7/60.9 | 72.8/69.6 | 81.9/78.3 |
Max. AC Input/Output Current (A) | 60/57.4 | 70/67 | 80/76.6 | 90/86.1 |
Max. Continuous AC Passthrough (grid to load) (A) | 100 | |||
Peak Power (off-grid) (W) | 2 times of rated power, 10s | |||
Power Factor Adjustment Range | 0.8 leading to 0.8 lagging | |||
Rated Input/Output Voltage/Range (V) | 220/230 0.85Un-1.1Un | |||
Rated Input/Output Grid Frequency/Range(Hz) | 50/45-55, 60/55-65 | |||
Grid Connection Form | L+N+PE | |||
Total Current Harmonic Distortion THDI | <3% (of nominal power) | |||
DC Injection Current | <0.5% In | |||
Efficiency | ||||
Max. Efficiency | 97.6% | 97.6% | 97.6% | 97.6% |
Euro Efficiency | 96.5% | 96.5% | 96.5% | 96.5% |
MPPT Efficiency | >99% | >99% | >99% | >99% |
Equipment Protection | ||||
Integrated Surge Protection Level | DC Reverse Polarity Protection, AC Output Overcurrent Protection, Thermal Protection, AC Output Overvoltage Protection, AC Output Short Circuit Protection, DC Component Monitoring, Arc Fault Circuit Interrupter (optional), Anti-islanding Protection, DC Switch, Insulation Impedance Detection, Residual Current Detection | |||
Interface | ||||
Communication Interface | RS485/RS232/CAN | |||
Monitor Mode | GPRS/WIFI/Bluetooth/4G/LAN (optional) | |||
General Data | ||||
Operating Temperature Range (°C) | -40 to +60°C, >45°C Derating | |||
Permissible Ambient Humidity | 0-100% | |||
Permissible Altitude | 3000m | |||
Noise (dB) | <55 | |||
Ingress Protection (IP) Rating | IP 65 | |||
Inverter Topology | Non-Isolated | |||
Over Voltage Category | OVC II (DC), OVC III (AC) | |||
Cabinet Size (WxHxD mm) | 464×763×282 (Excluding Connectors and Brackets) | 464×763×282 | 464×763×282 | 464×863×282 |
Weight (kg) | 54.1 | 54.1 | 54.1 | 59.8 |
Type of Cooling | Intelligent Air Cooling | |||
Warranty | 5 Years/10 Years | |||
Grid Regulation | IEC 61727, IEC 62116, NRS 097 | |||
Safety/EMC Standard | IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 |