Opera Serene Profiling Mattress
User Guide and Technical Specifications
Enhancing Lives, Delivering Comfort
Visit operabeds.com | Call 0333 222 8584
1. Explanations of Symbols
- ⚠️ Read information with this symbol carefully and urgently follow instructions. This information is safety-relevant.
- ⚠️ This symbol indicates general hazards. There is danger to life and health.
- CE Conformity mark in accordance with the European Medical Device Directives 93/42 EEC amended by 2007/47/EC.
- UK CA Conformity mark in accordance with the UK Conformity Assessed.
- ⚖️ Maximum patient weight.
- ? Indoor use only.
- ♻️ This product must be disposed of in a separate refuse collection in the European Union. Do not dispose of as normal domestic waste.
- ℹ️ Read instructions.
- Manufacturer.
- Date of Manufacture.
2. User Instructions
2.1 Intended Uses
The Opera Serene Profiling Mattress is a medical device intended to be used with care beds in residential homes, nursing homes, and the domestic environment as a pressure redistribution mattress. The mattress is intended to be used by occupants* weighing up to 29st 1lb/185kg.
The mattress is designed to prevent the development of pressure ulcers in occupants in the high risk** category, but may also be used for lower risk categories. It can also be used as a mattress to sleep, rest on, and receive care from.
The mattress can be used in conjunction with profiling care beds, including the Opera Classic Profiling Beds, the Signature Profiling Beds, and the Solo Profiling Bed collections. Before using the mattress with a care bed, confirm that the mattress specifications meet the requirements of the care bed.
If the mattress used does not meet the care bed requirements, entrapment and injury may occur. The mattress may also be used with mattress underlays and fall prevention systems; always conduct a risk assessment when using the mattress with other products. Using the mattress with the wrong bed may void the warranty terms and conditions.
*The mattress may be used by adults, the elderly, and children, subject to a clinician's guidance. The mattress is not intended for use by young children or as a cot mattress.
**Indication of use based upon interference pressure readings; this is not a prescriptive criterion. Always defer to a clinician's judgment and advice.
2.2 Non Intended Uses
A non-intended use deviates from the intended purpose and is not outlined in the Instruction Manual. Non-intended uses include, but are not limited to:
- Loading the mattress beyond the maximum user weight (29st 1lb/185kg).
- Using the mattress with any devices that compromise the general safety and performance requirements of the mattresses.
- Modifying the mattress or mattress cover.
- Using the mattress with a different mattress cover or vice versa.
- Using the mattress as an underlay or overlay.
- Using the mattress without its cover.
- Using the mattress when the cover or foam is compromised.
Using the mattresses for any of the above uses or a use not outlined in this instruction manual will be regarded as a non-intended use, which may void the warranty terms and conditions.
2.3 Using the Mattress
The mattress arrives compact and rolled. Carefully remove the plastic packaging and unroll. The mattress should be unrolled within 21 days of receipt. The mattress can be used one hour after unrolling, however, it may take longer before the mattress is fully restored to its original shape.
Before using the mattress for the first time, ensure upon arrival that there is no damage to the mattress and cover, including cuts, tears, and frayed edging. Make sure that once unrolled, the cover seams sit correctly to the edges of the mattress and that the three zips are fully closed.
⚠️ If the mattress cover is compromised, do not use it as this may result in infection. Take the mattress out of service and inform the person responsible for the mattress.
Always clean the mattress cover before using it for the first time, and between patients. Refer to section 3 for instructions on how to maintain and clean the mattress and cover.
Ensure that the bed platform surface is clear from debris before placing the mattress onto the bed mattress platform. Failure to do so may result in damaging/puncturing the cover, allowing fluid ingress to contaminate the foam core.
After ensuring the bed platform is clear from debris, place the mattress onto the bed. The audit box should be at the foot end of the bed.
Place a clean light cotton or linen type bed sheet over the mattress.
⚠️ Do not use heavy duvets or tightly "tucked in" blankets that may force additional pressure on the toes, leading to damage on the bony prominences of the heels. The usage of additional waterproof mattress covers, electric blankets, or similar items may reduce the effectiveness of the pressure-reducing properties of the mattress. These may also lead to an increase in body temperature, potentially resulting in skin maceration. Please seek clinical advice if you wish to use any covering other than cotton or linen bed sheets.
Regular turning is recommended for 4-way turning mattresses like the Opera Serene Profiling Mattress to prevent foam fatigue. Regular turning ensures that weight is distributed evenly across both sides and ends of the mattress, prolonging its service life.
The cover may be removed for cleaning; refer to chapter 3 for further instructions. To remove the cover, unzip it. When replacing, ensure the outer cover is on the outside and not the inside. Non-compliance may compromise the functions of the cover, including its antimicrobial, water-resistant, white substrate, and chlorine-resistant properties, and may result in serious infection.
The label on this mattress has a unique serial number which should be used in the event of a warranty claim. Never remove the label.
2.4 Confirm Compliance
⚠️ When used with a care bed, ensure the mattress meets the care bed requirements; failure to do so may result in entrapment hazards and injury.
⚠️ The side rail height from the top of the mattress in an uncompressed condition and the top upper edge of the side rail must be a minimum of 220mm. Failure to comply may result in entrapment and fall hazards, potentially leading to serious injury.
3. Maintenance and Inspections
3.1 Inspections and Audits
It is recommended that audits occur every 6 months to inspect for signs of damage. In a community setting, audits should also be conducted between each patient change. Mattresses should be cleaned as and when required.
⚠️ Inspect the inner and outer surfaces of the mattress covers and check the zips and seams for any signs of damage. Failure to check this may compromise the features of the mattress cover.
⚠️ If the cover has been stained, soiled, or compromised, the inner mattress must be examined. The white audit substrate inside the cover helps identify any strike-through from heavy soiling/fluids. If the cover is compromised, the mattress should be withdrawn from use immediately. Failure to withdraw the mattress and cover from use poses a significant risk of infection to the patient and any carers.
3.1.1 Mount Vernon Test
The Mount Vernon Test should be performed during an audit, patient change, or when there are doubts about the foam condition. The test ensures that the foam continues to deliver support.
Follow these steps to perform the Mount Vernon Test on the mattress and cover:
- Adjust the bed platform height so that the top of the mattress is level with the tester's hip.
- Standing at the side of the bed, link both hands to form a fist. Keep elbows straight and lean forward, pushing fists into the mattress at the points indicated in Figure 1. If the bed base can be felt at any point, the mattress has 'bottomed out' and should be withdrawn from service immediately. Failure to observe this instruction may pose a significant risk of pressure damage to the user.
Figure 1: Mount Vernon Test points
For further information on how to inspect and audit the mattress, please refer to:
- Mattresses: Prevention of Cross Infection MDA SN 1999 (31)
- Medical Device Alert: All types of bed mattresses MDA/2010/002
- BHTA guidance on the care, cleaning, and inspection of healthcare mattresses (BHTA Protect, Rinse and Dry).
Always follow your local regulations and guidelines.
3.2 Cleaning and Disinfection
Clean the mattress regularly and as and when required.
For general cleaning and superficial dirt, use a disposable wipe with a solution of warm water and neutral detergent. Do not use abrasive or phenolic-based cleaners.
To disinfect in situ, use a 0.1% sodium hypochlorite solution (1000 ppm chlorine). Do not use biological or phenolic-based cleaners.
Removable, contaminated covers should be laundered at 65°C for no less than 10 minutes or at 95°C for no less than 3 minutes.
Thoroughly rinse and dry the cover before re-use or storage. Store in a cool, dry area.
Do not mangle or iron. Spin and tumble-dry at no more than 60°C.
3.3 Storage and Care
- Store the mattress flat – do not fold.
- Do not place heavy objects on the mattress surface when not in use.
- Do not allow sharp objects to penetrate the cover or damage its coating.
- Keep the mattress clean.
- Regularly inspect the interior and exterior of the mattress.
- Do not store in damp conditions.
- Store out of direct sunlight.
- ⚠️ Store away from sources of ignition and heat, such as radiators, open fires, heaters, and electric heaters.
To aid storage and handling, store the mattress in a protective covering. When removing packaging, be careful not to damage or catch the mattress cover. Always clean the mattress before putting it back into service and inspect/audit the mattress and cover. Failure to observe this instruction may result in creating hazardous situations and posing risks such as infection.
3.4 Flammability
The Opera Serene meets the requirements of BS7177:2008 for medium hazard. The mattress meets the requirements of The Furniture & Furnishings (Fire Safety) Regulations 1988.
4. Safety Instructions
4.1 General Safety Instructions
ℹ️ During briefing, specific attention must be drawn to any potential dangers for the first time. The instruction manual must be read conscientiously and in detail by the user/care personnel.
Any incidents or issues must be reported to Opera at support@operabeds.com.
⚠️ When the mattress is used with a care bed, ensure it meets the care bed requirements; failure to do so may result in entrapment hazards and injury.
⚠️ When using the mattress with side rails, the side rail height from the top of the mattress in an uncompressed condition and the top edge of the side rail must be a minimum of 220mm. Failure to comply may result in entrapment and fall hazards, potentially leading to serious injury.
⚠️ If the cover is compromised, the mattress should be withdrawn from use immediately. If the foam and cover are compromised, the mattress and cover should be withdrawn from use immediately and replaced. Failure to withdraw the mattress and cover from use poses a significant risk of infection to the patient and any carers.
⚠️ Do not pierce or compromise the mattress cover, as this will compromise the foam and poses a significant risk of infection to the user and any carers.
⚠️ Do not use the mattress without the mattress cover; failing to observe this warning will compromise the infection and control properties of the mattress, potentially leading to infections, sores, and other alignments.
⚠️ Do not store the mattress near heating devices such as electrical fires, radiators, or sources of heat, as this may result in fire leading to serious injury, property damage, and death.
⚠️ Avoid contact with sharp objects and abrasive surfaces. Do not drag mattresses; failure to observe this may result in compromising the cover and foam mattress.
The mattress is not designed for use in a mental health facility or by those at risk of vandalizing the mattress. Using the mattress in such environments may result in vandalism and the creation of hazardous situations that could lead to injury, property damage, and death.
⚠️ Do not smoke around or on the mattress, as this is a common cause of fires. Failure to observe this warning may result in severe injury, property damage, and death.
⚠️ Keep the cover away from young children when not in use; openings can result in asphyxiation and death.
⚠️ If the bed base can be felt, the mattress has 'bottomed out' and should be withdrawn from use immediately. Failure to observe this warning may pose a risk of pressure damage to the user.
⚠️ When used with a profiling bed, ensure the mattress is fitted into the mattress retainers. Failure to do this may result in the mattress moving, causing shear and friction to the user's skin, which can pose a risk of pressure ulcer development.
4.2 Service Life and Disposal
The service life of the mattress and cover depends on the manner of use. The service life may be extended if the product is carefully used and maintained. It may also be significantly reduced by incorrect and/or significant use.
When the service life ends, do not dispose of it as normal domestic waste. Please contact your local waste recycling facility for further guidance on safe disposal.
To put the mattress back into service, conduct an audit on the mattress and mattress cover as advised in section 3.
It is advised that a cleaning and service record is kept. Always clean the mattress between patients and as and when required, in accordance with local guidelines and this instruction manual.
5. Technical Specifications
5.1 Technical Data
Specifications for the Serene Profiling Mattress
Specifications | 3ft | 3ft 6' | 4ft |
---|---|---|---|
Maximum User Weight | 29st 1lb/185kg | ||
Depth | 150mm/6" | ||
Length | 2000mm/78.7" | ||
Width | 900mm/35.4" | 1050mm/41.3" | 1200mm/47.2" |
Weight of foam | 8.5kg | 10.5kg | 12kg |
Foam Type | Castellated SB33/160 CMHR | ||
Turn Cycles | 4 | ||
Warranty | 1 year | ||
Multi stretch cover with white substrate | Yes | ||
Antimicrobial cover | Yes* | ||
Moisture Vapour Permeable | Yes | ||
Cover Material | PU coated polyester | ||
Chlorine resistance | 0.1% (1000ppm) | ||
Zips | 3 Zips | ||
Seam type | Sewn | ||
Machine washable | <95°C | ||
Water resistance | Yes | ||
Weight of cover (Approx.) | 0.96kg | 1.1kg | 1.23kg |
Warranty | 1 year |
*Tested in a group test against Aspergillus niger & Staphylococcus aureus
5.2 Classification
CE Medical Device Class (Medical Device Directive 93/42 EEC) | Class I |
CRIB Rating | BS7177:2008 - Crib 5 (Ignition source 5) |
Treatment/Prevention Risk Category | High Risk |
5.3 Storage and Transport
Storage and Transport Conditions
Store the mattress in a dry, dark, clean environment. Do not store near heating appliances such as radiators, open fires, or electrical fires. Do not drag the mattress when transporting.
6. Guarantee
As stated in the Warranty Terms and Conditions, below, Opera provides a manufacturer's warranty of 1 year from the date of purchase for the mattress and mattress cover.
7. Opera Warranty Terms and Conditions
7.1 Warranty Terms
7.1.1 Subject to the terms and conditions set out below, Opera agrees to repair or replace the product within the United Kingdom at its own cost, and any Opera accessory supplied with it, purchased by you from Opera. This applies in circumstances where the product does not perform in accordance with Opera's specifications during the warranty period commencing on the date of delivery (or deemed delivery) of the product.
7.1.2 This contractual product warranty does not operate to limit rights under the statutory warranties referred to in clause 7.3.1 below.
7.2 Warranty Conditions
7.2.1 Proof of purchase (invoice) must be provided when requesting service under warranty.
7.2.2 Opera requires any customer requesting service under the warranty to comply with directions from Opera staff in relation to troubleshooting any issue and facilitating any repair or replacement under these Warranty Terms and Conditions.
7.2.3 The customer is responsible for inspecting all goods received from Opera upon arrival. In instances where goods have been damaged in transit, the customer must report this to Opera within 3 working days of receipt of the product. Failure to report physical damage on arrival within 3 working days of receipt may result in denial of warranty for physical damage.
7.2.4 Opera reserves the right to replace the product or relevant part with the same or equivalent product or part, rather than repair it. Where a replacement is provided, Opera will determine, in its discretion, the closest product within the current range of products offered by Opera with which to replace the faulty or damaged product. The replacement product may differ in size and specifications, at the reasonable election of Opera. Opera may replace parts with refurbished parts. Replacement of the product or a part under the warranty does not extend or restart the warranty period.
7.2.5 If Opera is unable to repair or replace the product, the customer will be provided with credit for Opera products or may be refunded the price of the product (at Opera's election). This credit or refund will be for the amount of the purchase price of the product, excluding the associated delivery cost.
7.2.6 In the event that a replacement, refund, or store credit is provided as per section 7.2.5, the faulty item will become the property of Opera.
7.2.7 Opera may seek reimbursement of any costs incurred by you where the product is found to be in good working order.
7.2.8 Opera reserves reasonable discretion to determine whether any product is or is not performing in accordance with Opera specifications, subject to applicable law.
7.3 General
7.3.1 Legislation may imply warranties, conditions, or impose obligations on Opera, which cannot be excluded, restricted, or modified in relation to consumer goods.
7.3.2 To the full extent permitted by law, but subject always to clause 7.3.1, the warranty will not apply in respect of a product:
- (a) If the product has not been installed, operated, maintained, or used in accordance with the Opera instructions or specifications provided with the product;
- (b) If the factory-applied serial number has been altered or removed from the product;
- (c) To damage, malfunction, or failure resulting from alterations, accident, misuse, abuse, fire, liquid spillage, mis-adjustment of customer controls, use on an incorrect voltage, power surges and dips, thunderstorm activity, force majeure, voltage supply problems, tampering or unauthorised repairs by any persons, use of defective or incompatible accessories, exposure to abnormally corrosive conditions, or entry by any insect, vermin, or foreign object in the product.
- (d) To damage arising during transportation, installation, or while moving the product or to any transportation costs of the product or any parts thereof to and from the customer, unless otherwise specified in these warranty terms and conditions;
- (e) To any third-party software or hardware not contained in the product as originally configured by Opera.
- (f) To any failure, to the extent that the failure is not a failure of the product to perform in accordance with its specifications.
- (g) To service of any product whilst it is outside the United Kingdom.
7.3.3 To the full extent permitted by law, but subject always to clause 7.3.1:
- (a) Opera will not be liable for any loss, damage, or alterations to third-party products, no matter how occurring; or for any loss or damage arising from loss of use, loss of profits or revenue, or for any resulting indirect or consequential loss of damage.
- (b) Opera's aggregate liability in respect of all claims under the warranty shall not exceed the original purchase price of the product or, at Opera's option, the replacement of the product with a like or similar product.
- (c) Opera excludes all other warranties, conditions, terms, representations, and undertakings whether express or implied.