User Manual for Spark models including: M3 Moto Spark, M3, Moto Spark, Spark
Changsha Spark Technology Electronics Co.,Ltd MOTO-C1 MOTO CONTROLLER 2BEDK-MOTO-C1 2BEDKMOTOC1 moto c1
MOTO-C1 Moto Controller by Changsha Spark
File Info : application/pdf, 21 Pages, 1.19MB
DocumentDocumentwww.sparkfabrica.com CHAN GSHA SPARK TECHN OLOGY ELECTRON ICS CO.,LTD MOTO SPARK M3 USER MANUAL MOTO SPARK USER MANUAL M 3 CONTENTS 1 PRODUCT INTRODUCTION A2 1.1 PRODUCT OVERVIEW A2 1.2 PRODUCT ACCESSORIES A3 1.3 SPARK FABRICA GRANULE A3 2 TECHNICAL PARAMETER A4 3 SCREEN OPERATION GUIDE A5 3.1 BACK PANEL INTRODUCTION A5 3.2 MENU SETTING A6 3.3 STATUS ICONS A7 3.4 DMX PARAMETER LIST A7 4 OPERATION NOTES A8 4.1 WORKING CONDITION REQUIRED A8 4.2 SAFETY TIPS A9 5 Battery A9 5.1 Type of battery A9 5.2 Installatin of battery A9 5.3 How to charge battery A9 5.4 Maintenance of battery A9 5.5 Auto-switch between battery and AC A10 6 MACHINE OPERATION A10 6.1 PREPARATION A10 6.1.1 INSTALL MACHINE A10 6.1.2 FILL IN SPARK FABRICA GRANULE A11 6.2 CONNECT MACHINE A11 6.3 INITIAL SETTING A12 6.3.1 SET CHANNEL MODE A13 6.3.2 SET DMX ADDRESS A13 6.4 SWIPE RFID TIME CARD A13 6.5 START TO SPARK A13 6.5.1 TURN ON CONSOLE'S POWER A13 6.5.2 TURN ON HEATING FUNCTION A13 6.5.3 ADJUST SPARKING HEIGHT A14 6.5.4 HOW TO SET THE REMOTE CHANNEL OF REMOTE CONTROLLER A15 6.5.5 HOW TO USE REMOTE CONTROLLER TO CONTROL THE MOTO SPARK A15 6.6 CLEAR MATERIAL A16 6.7 CLEAN MACHINE A16 7 MACHINE MAINTENANCE A16 8 FAILURE HANDLING A17 CHAN GSHA SPARK TECHN OLOGY ELECTRON ICS CO.,LTD www.sparkfabrica.com DISCLAIMER Please read the manual carefully before installing and using this product. Failure to read or comply with this manual may result in injury to products and personnel, and Spark Fabrica shall not be responsible for this. This product is a professional machine, we do not assume any responsibility for accidents or losses caused by the use or maintenance of this product by personnel without professional training and permission. you further and responsible for any errors or omissions. Our company reserves the right to modify the user manual at any time PREFACE This manual includes warning, caution and notice concerning the safe operation of equipment. These warningcaution and notice come with the following icons. Please read them carefully! This warning indicates a dangerous situation that may result in death or serious injury if not avoided. CAUT ION This alert indicates a dangerous situation that may result in mild or moderate injury if not avoided. NOTICE This means that you need to be careful. MOTO SPARK USER MANUAL M3 | A1 www.sparkfabrica.com 1. PRODUCT INTRODUCTION CHAN GSHA SPARK TECHN OLOGY ELECTRON ICS CO.,LTD three controllable variables: height, density and duration. This product is widely used in weddings, concerts, sports events, event meetings and so on.Stimulate your interest and light up your activity. 1.1 PRODUCT OVERVIEW GRANULE FILLING PORT LCD SCREEN FUSE POWER SWITCH POWER IN POWER OUT DMX IN DMX OUT MOTO SPARK USER MANUAL M3 | A2 OUTPUT NOZZLE HANDLE AIR INLET CHAN GSHA SPARK TECHN OLOGY ELECTRON ICS CO.,LTD www.sparkfabrica.com 1.2 PRODUCT ACCESSORIES 1 Adapater User Manual Safefy ring NOTICE Open the package carefully and check to make sure the goods are in good condition. 1.3 SPARK FABRICA GRANULE A special metal powder has the characteristics of high content, little residue, belonging to a special consumables with no smoke, odor and other harmful gas when sparking. Only the consumables provided by Spark Fabrica are allowed to be used. Spark Fabrica shall not be liable for any damage to machines, personnel and property caused by the use of consumables not provided by the company. MOTO SPARK USER MANUAL M3 | A3 www.sparkfabrica.com CHAN GSHA SPARK TECHN OLOGY ELECTRON ICS CO.,LTD 2 TECHNICAL PARAMETER Identification AC Power Heating Hopper Technical Parameters Control Accessory Certification Weight Dim ensions Granule Manufacturer Nam e Model Input Voltage & Frequency Current Limiter Specifications Constant Current Nominal Total Power Consumption Heat Up Time Powder Tank Capacity Removable Hopper Lineary Adjustable Density Adjustable Height Height Level Powder Consumption (100% Output) Maximum Single Continuous Duration Control Protocol RFID Proximity Card RDM Power Safety Ring CE ROHS FC Net Weight Gross Weight Machine Dimensions - L* W* H Packing Dimensions - L* W* H Granule SPARK FABRICA MOTO SPARK M3 100-120V50 / 60HZ 200-240V50 / 60HZ 6.3A,100-120V / 6.3A,200-240V 5.5A,100-120V / 2.7A,200-240V 500W < 10miutes under battery mode 150g N/A 30-100% 2-5m 1-10 Level 2 0 -2 5 g/Minute 30s DMX-5 1 2 X Adapter 10Kg 1 1 kg 2 5 0 X2 4 0 X2 8 0 m m 2 9 0 X2 9 0 X3 8 0 m m Spark Fabrica granule MOTO SPARK USER MANUAL M3 | A4 CHAN GSHA SPARK TECHN OLOGY ELECTRON ICS CO.,LTD www.sparkfabrica.com 3 SCREEN OPERATION GUIDE 3.1 BACK PANEL INTRODUCTION LCD SCREEN READY When the equipment is ready, flashing light means that the heating temperature has not reached the set holding temperature, and long light means that the temperature of the movement has reached the spray requirements. DMX DMX input mode indicates that the DMX signal has been received, and the indicator light will keep flashing in wireless host mode. FAULT Error message indication: when the device runs wrong, the indicator light will turn on and the LCD will display error message. HEAT Movement heating status indicator, long light that is heating. POWER SWITCH POWER OUT DMX OUT POWER IN DMX IN ENT ER INCREASE Decrease MENU MOTO SPARK USER MANUAL M3 | A5 www.sparkfabrica.com 3.2 MENU SETTING PT:30¥ ST:680¥ DMX:1 PW:24.7V TotaTime:xx H xx M BY SPARK FABRICA Machine Ready SOC:47% SPARK FABRICA S etti n g Advanced Machine Status I n fo r m a ti o n CHAN GSHA SPARK TECHN OLOGY ELECTRON ICS CO.,LTD Tem p e r a tu r e DMX Channel DMX Address ClrError Address Charge Batty RFID Auto Heat Res tore Defaults F M -A: X X X X Ta : x x x x P1 -V: x x x x B 1 -V: x x x x DMX0:xxx DMX1:xxx DMX2:xxx DMX3:xxx M3 Ver:2201 CN:X X X X X X X X RF VER:2202 Set Temperature ST680 DMX Chnnel 2 Set DMXAddr 1 RF Channel 1 Set SafetyAddr OFF Set ClrErrorAddr OFF Batter y Charge OFF RFID x Auto Heat OFF Tilt Sensor OFF TFT BackLight OFF Res tore Defaults OFF NOTICE NOTICE NOTICE Press <OK> to enter the menu setting. The screen will automatically return to the main state Press · key or - tion, and please press < 0K > key to save the change. Press MOTO SPARK USER MANUAL M3 | A6 CHAN GSHA SPARK TECHN OLOGY ELECTRON ICS CO.,LTD www.sparkfabrica.com 3.3 STATUS ICONS 2/ 8 NOTICE When the icons are green means the machine is working normally, and yellow means abnormal. Wireless Connection Temp Sensor Unconnected Tip Over PCB Too Hot 2/ 8 2-8 Channel mode AC mode Blower Motor Hopper Motor Temp Over Heat Lack Of Time Sub PCB Connected Battery mode First Channel 0~10 11~255 Second Channel 0~200 11~39 56~200 240~255 Function Stop Fountain Height Function Emergency Stop Clear Material Pre-heat On NOTICE The DMX address of safety channel must above 200 4 OPERATION NOTES Please read the following Operation Notes carefully before working with the machine. MOTO SPARK USER MANUAL M3 | A7 www.sparkfabrica.com CHAN GSHA SPARK TECHN OLOGY ELECTRON ICS CO.,LTD 4.1 WORKING CONDITION REQUIRED environment. carpet, wood, paper, carton, Ground water entering or covering the bottom of the machine will cause machine failure or electrical leakage risk. Make sure the bottom of the machine is at a safe distance from the surface water in rainy weather to avoid surface the machine from the bottom. ventilation, at least 20 in (50 cm) from adjacent surfaces. weather. Do not use the machine at temperature above 122 'F (50¥). Always connect the ground wire to avoid electric shock.The machine cannot be submerged in water while operating it. Do Not touch the sparks.During heating up and operation, do not touch the housing. Ensure nothing drop(s) into the nozzle of Spark Jet Pro unit. Do Not cover output nozzle port. MOTO SPARK USER MANUAL M3 | A8 CHAN GSHA SPARK TECHN OLOGY ELECTRON ICS CO.,LTD www.sparkfabrica.com Make sure that children, unauthorized people and animals do not obtain access to the machine. The noise level generated from the spark machine unit is estimated at 80dB depending on the point nearest to the machine(s) during operational discharge mode. Substance Fires. 5 Battery 5.1 Type of battery 5.2 Installatin of battery This machine must install 21 pieces of battery. Less battery will lead to malfunction of machine or result in battery explosion due to overloaded charging current. Please follow the instruction on the battery panel to install the battery. Do not install battery upside down . 5.3 How to charge battery Connect the power plug to AC, turn on the machine, go to screen to choose BATTERY CHARGING MODE from the menu. Then it will start charging the battery. Connect the power plug to AC, turn on the machine, go to screen to choose BATTERY CHARGING MODE from the menu. Then it will start charging the battery. 5.4 Maintenance of battery MOTO SPARK USER MANUAL M3 | A9 www.sparkfabrica.com CHAN GSHA SPARK TECHN OLOGY ELECTRON ICS CO.,LTD 5.5 Auto-switch between battery and AC When you plug in the power cable, machine will automatically switch to AC mode. 6 MACHINE OPERATION 6.1 PERPARATION = 0° 15° 6.1.1 INSTALL MACHINE Install the product on truss by using the attached accessories. 15° MOTO SPARK USER MANUAL M3 | A10 CHAN GSHA SPARK TECHN OLOGY ELECTRON ICS CO.,LTD 6.1.2 FILL IN SPARK FABRICA GRANULE www.sparkfabrica.com top of the machine. * Fill the consumable into the feed portNOT into the output nozzle. * The capacity of storage bin is 150g. Open the lid SPAPARKCK MOTO SPARK USER MANUAL M3 | A11 www.sparkfabrica.com CHAN GSHA SPARK TECHN OLOGY ELECTRON ICS CO.,LTD Do not use damaged power plug and power cable.One power plug is recommended to connect 4 units in series at most for this product. enhance the anti-interference of the machine. Please calculate all products' total current required according to the power supply and fuse parameters of the products. The standard length of the power connection line and the signal connection line is 3 meters, and a longer length can be reached by connecting in series. 6.3 INITIAL SETTING Setting Set Temperature DMX Address DMX Channel Mode Density Safety Addresss Tilt Sensor Res tore Defaults TFT BackLight Auto Heating Range 680-700 1~512 2/8 30~100 0~512 ON/OFF YES/NO ON/OFF ON/OFF * Turn on power * Check the machine status icon(refer to icon introductions of 3.3) asking the professional to check and repair the machine. Default 680 1 2 100 OFF(0) ON NO ON OFF * The sparking temperature of the machine is the factory default temperature. The product will heat up automatically please refer to "3.2 MENU SETTING". * When spark machines connect DMX signal, the heating function can be started only on the Sim Pyro Console. MOTO SPARK USER MANUAL M3 | A12 CHAN GSHA SPARK TECHN OLOGY ELECTRON ICS CO.,LTD 6.3.1 SET CHANNEL MODE refer to "3.2 MENU SETTING". www.sparkfabrica.com 6.3.2 SET DMX ADDRESS Please set DMX address according to channel mode: * In the 2 channel mode, please set spark machines' DMX address to 1.3.5.7...... Please do not set address code repeatedly. 6.4 SWIPE RFID TIME CARD product can only be used with special RFID time card. Each swipe of the card can be recharged for 12 minutes, and each machine can swipe up to 2 time cards for 24 minutes at most.The card can only be swiped again when the remaining time is less than 20 minutes. If the customer breaks the card swiping function or cancels the card swiping function at the Fabrica. Spark Fabrica shall not be liable for any accidents and losses about this. 6.5 START TO SPARK The machine can be controlled by Pyro Sim Controller console or DMX512 console. 6.5.1 TURN ON THE CONSOLE' POWER 6.5.2 TURN ON HEATING FUNCTION The heating function of the second channel DMX value is 240~255, and it takes about 5 When heating is turned on, the <HEAT> indicator light on the machine will turn to red, and the spark machine will enter sparking status. MOTO SPARK USER MANUAL M3 | A13 www.sparkfabrica.com CHAN GSHA SPARK TECHN OLOGY ELECTRON ICS CO.,LTD When using the Pyro Sim Controller controller,the screen will display the real-time temperature of each machine. When the temperature value of the control board turns green, it means that the heating is completed and the machine enters the status of sparking. 6.5.3 ADJUST SPARKING HEIGHT values 11-255. During heating up and operation, do not touch the housing. - indoor granule is 3.5 meters, while outdoor granule is 5 meters. Substance Fires. MOTO SPARK USER MANUAL M3 | A14 CHAN GSHA SPARK TECHN OLOGY ELECTRON ICS CO.,LTD www.sparkfabrica.com 123 123 456 456 789 789 10 11 12 10 11 12 ON ON 15S OFF OFF 30S LOW HIGH CLEAR HEAT ON HEAT OFF OFF/CODE www.sparkfabrica.com 6.5.4 HOW TO SET THE REMOTE CHANNEL OF REMOTE CONTROLLER The remote controller provides 12 remote channel options. Turn on the power of remote controller, 12 controller, hold the selected button for 8 seconds. 6.5.5 How to use remote controller to control the moto spark If the remote controller set the remote channel between 1-12, lets make 2 for example. Then we choose the RF channel on the machine screen to 2, then the remote controller can control the machine. 1 ON 2 ON 3 15S 4 OFF 5 OFF 6 30S 7 LOW 8 HI GH 9 CLEAR 10 HEAT ON 11 HEAT OFF 12 OFF/CODE function will be broken. MOTO SPARK USER MANUAL M3 | A15 www.sparkfabrica.com CHAN GSHA SPARK TECHN OLOGY ELECTRON ICS CO.,LTD The remote controller has 4 height levels. 6.6 CLEAR MATERIAL This product has the function of cleaning material, which can clean up the heated but not sparked consumables, so as to avoid nodulation in the heating chamber and causing stuck machine. Use the cleaning function of the second channel for cleaning, DMX value is 56-200. This function must be performed at the end of each show. 6.7 CLEAN MACHINE * Remove power connection and DMX signal cable. * Use a damp cloth to remove dust and debris from the surface of the machine. * Unused Spark Fabrica Granule should be stored in a cool, dry place, vacuum packed insealed foil bags, and prote- has stopped. To eliminate unnecessary machine wear and improve its lifespan,unplug the power of the on the power cord. 7 MACHINE MAINTENANCE Some steps are needed in order to clean and maintain the product for maximum usage. The recommended procedure is as follows: MOTO SPARK USER MANUAL M3 | A16 CHAN GSHA SPARK TECHN OLOGY ELECTRON ICS CO.,LTD www.sparkfabrica.com 8 FAILURE HANDLING Error Code Bat Voltage LOW Description Battery voltage UN-normal Solution Replace main board Motor Protect E1 M1 Blower motor protection/ disconnected 1.Restart machine to clear alerts,stop operating for 15 minutes until temperature return to normal. 2.Check wire connection of motor 3.Replace motor 4.Replace main board Motor Protect E1 M2 Motor Protect E1 M3 Temp Sensor E2 Unconnected 2.Check wire connection of motor disconnected 3.Replace motor 4.Replace main board 1Hopper motor clog ( perform clean material function manually) Hopper motor protection/ 2.Check wire connection of motor disconnectd 3.Replace motor 4.Replace main board Temperature sensor disconnected 1.Check wire connection of temperature sensor 2Replace Temperation sensor 3.Repalce Main board PCB Too Hot E3 Time Remain E4 Main board too hot Stop operating machine until main board temperature return to normal Please scan new RFID card Temp Over Heat E5 Heating protection due to over-temperature. Heat Fail E6 Heating process fail Tip Over E7 Tip over alert Sub PCB Unconnected E8 Sub-PCB disconnected Stop operating machine until temperature return to normal. 1Inspect Wire connection of heating board. 2.Replace heating coil 3.Replace heating board Machine will activate tip over protection if the angle is more put the machine back to normal position. 1.Check wire connection of Sub-PCB 2.Replace Sub-PCB 3.Replace Main Board Illegal Card Machine Locked Machine locked because Use illegal or copy RFID card will lock the machine. If so ,seller of using illegal or copy RFID card. the machine,please contact seller. MOTO SPARK USER MANUAL M3 | A17 XXXTQBSLGBCSJDBDPN NBSLFUJOH!TQBSLGBCSJDBDPN This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: -- Reorient or relocate the receiving antenna. -- Increase the separation between the equipment and receiver. -- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -- Consult the dealer or an experienced radio/TV technician for help. Warning: changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment The devices has been evaluated to meet general RF exposure requirement the device can be used in portable exposure condition without restriction