Owner's Manual for TRION models including: 259942-001, CFS-05B, CFS-05D, CFS-05R, CFS-05, CFS-10, CFS-15, CFS-15 Comfort Steam Humidification System, CFS-15, Comfort Steam Humidification System, Steam Humidification System, Humidification System

Owner's Manual for TRION 259942-001

Owner's Manual for TRION 259942-001 provided by Appliance Factory Parts

Appliance, Factory, Parts, Manual, Replacement Parts, TRION 259942-001

Appliance Factory Parts

Specification Data [pdf]

Trion 259942-001 Parts | Humidifiers


File Info : application/pdf, 3 Pages, 863.83KB

PDF preview unavailable. Download the PDF instead.

135860-6
This Owner's Manual is provided and hosted by Appliance Factory Parts.
TRION 259942-001 Owner's Manual
Shop genuine replacement parts for TRION 259942-001
Find Your TRION Humidifier Parts - Select From 27 Models -------- Manual continues below --------

COMFORTSTEAMTM
Humidification System

Air Purification Systems

TECHNICAL ENGINEERING SPECIFICATION

Electric Valve
Tank Cover
Tank Latch Internal Drain Outlet (Factory installed with hose)
02-0405

Performance:
COMFORTSTEAMTM is an isothermal system that produces odorless, sterile, and bacteria-free humidification. Steam is produced at atmospheric pressure and dispersed into the HVAC ductwork via a steam nozzle or perforated steam diffuser. Selection includes three capacities ranging from 13 GPD to 34.5 GPD (4.5 ­ 12 lbs/hr steam). Units are available in 120 VAC and 240 VAC. An available electronic humidistat with outdoor reset automatically reduces the humidity setpoint as the outdoor temperature falls. Each unit is factory tested and CSA certified.

Electronic Humidistat With Outdoor Sensor

Manual Thermal Cut-Out

Top View

Water Level Sensors Steam Outlet Heating Element

Tank Detail

Water Tank

Features:
· Clean Steam ­ Odorless & Sterile, Bacteria ­ Free Humidification · Installation Flexibility ­ Duct Or Remote Mountable · On-Board Diagnostics ­ User Friendly Display Shows Mode Of
Operation And Status · Fault Annunciation ­ LED Blinks To Simplify Fault Diagnosis · Ease Of Service­ Quick Release, Stainless Steel Tank · Versatile Microprocessor Controls ­ Adaptable To Various Water
Qualities · Siphon Draining System ­ Eliminates The Chance Of Blocked
Solenoid Valves And Drains At A Safe Temperature · Compact Chassis Design ­ Light Weight And Simple To Install · Silent Operation · Full Complement Of Accessories · CSA Certified

WW ER-HVAC.COM

Applications:
· Residential · Commercial · Hospitals · Computer Rooms · Laboratories · Clean rooms · Telecommunications · Switch Gear Facilities · Humidors
Warranty:
· 2-Year Limited Warranty

W.TRIONINC.CO
H U M I D I F I C AT I O N
COMFORTSTEAMTM
SYSTEMS
WWW.HERRMIDIFI

M

www.trioninc.com | www.herrmidifier-hvac.com

Air Purification Systems

COMFORTSTEAMTM
Humidification System

TECHNICAL ENGINEERING SPECIFICATION

COMFORTSTEAMTM Dimensional Data

Humidistat Wiring
Electrical Knockout

11.88" 10.88"

4.50" 1.50"

Supply Water Connection

14.00"

Steam Outlet

16.00"

Top View

11.63" 13.00"
Front View

9.00" Side View

COMFORTSTEAMTM Specifications

Specifications

CFS-05B

CFS-05D

CFS-05R

CFS-05

CFS-10

CFS-15

Capacity (GPD/PPH)1 Kilowatts (KW) Voltage Full Load Amps (FLA) Dimensions Airflow Switch Water Hammer Absorber Electronic Humidistat Shipping Weight Tight Home2 Average Home3 Loose Home4

13/4.5

13/4.5

13/4.5

13/4.5

26/9

34.5/12

1.5

1.5

1.5

1.5

3.0

4.0

120 VAC

120 VAC

120 VAC

120 VAC

240 VAC

240 VAC

12.5

12.5

12.5

12.5

12.5

16.6

16"H x 13"W x 9"D 16"H x 13"W x 9"D 16"H x 13"W x 9"D 16" H x 13"W x 9"D 16"H x 13"W x 9"D 16"H x 13"W x 9"D

No

Yes

Yes

Yes

Yes

Yes

No

Yes

Yes

Yes

Yes

Yes

Not Included

Duct

Room

Not Included

Not Included

Not Included

23 Lbs.

23 Lbs.

23 Lbs.

23 Lbs.

23 Lbs.

23 Lbs.

4000 Sq. Ft.

4000 Sq. Ft.

4000 Sq. Ft.

4000 Sq. Ft.

8000 Sq. Ft.

10600 Sq. Ft.

2000 Sq. Ft.

2000 Sq. Ft.

2000 Sq. Ft.

2000 Sq. Ft.

4000 Sq. Ft.

5300 Sq. Ft.

1300 Sq. Ft.

1300 Sq. Ft.

1300 Sq. Ft.

1300 Sq. Ft.

2600 Sq. Ft.

3500 Sq. Ft.

1. Gallons Per Day/Pounds Per Hour (steam) 2. A "Tight Home" is assumed to be well insulated with vapor barriers, tight storm windows and doors, and a dampered fireplace. Air exchange rate of .5 changes per hour. 3. An "Average Home" is insulated and has a dampered fire place, but there are no vapor barriers, storm doors, or storm windows. Air exchange rate of 1.0 change per hour. 4. A "Loose Home" is generally one constructed before 1930, has little or no insulation, no storm doors, storm windows, weather stripping or vapor barriers, and often no effective
dampering of fireplaces. Air exchange rate is as high as 1.5 changes per hour.

©2009 Trion®- Indoor Air Quality Solutions | Herrmidifier® - Engineered Humidification Solutions Trion® and Herrmidifier® are registered trademarks of Air System Components, Inc. Trion® reserves the right to revise or modify products and/or specifications without notice. All product specifications reflect available information at the printing of this brochure.