ASUS MIL-STD 810H Test Report - B7402FBA
This report details the results of MIL-STD 810H testing performed on the ASUS ExpertBook B7 Flip B7402FBA. The testing aims to ensure the product's durability and reliability under various environmental conditions.
Test Summary
The ASUS ExpertBook B7 Flip B7402FBA has undergone a series of rigorous tests according to the MIL-STD-810H standard. The majority of tests conducted resulted in a 'Pass' status, indicating the device's resilience.
Note: The testing regime includes requirements of military-grade standards and varies depending on the device. MIL-STD-810 testing is conducted on selected ASUS products only. This testing helps ensure the quality of ASUS products but does not indicate a particular fitness for military use. The tests are performed under laboratory conditions. Any damage caused by attempts to replicate these test conditions would be considered accidental and would not be covered by the standard ASUS warranty. Additional coverage is available with ASUS Premium Care.
Detailed Test Results
Test Category | Test Method | MIL-STD-810H Test Parameters | Test Result |
---|---|---|---|
Altitude Storage/Air Transport | Method 500.6-Procedure I | Test Pressure: Equivalent to cabin altitude of 40,000ft Temperature: -20°C Duration: 12 hour Unit is non-operational during test. |
Pass |
Altitude Operation/Air Carriage | Method 500.6-Procedure II | Test Pressure: Equivalent to cabin altitude of 15,000ft Temperature: 5°C and 40°C Duration: 12 hour (5°C) and 12 hour (40°C) Unit is operational during test. |
Pass |
High Temperature Operational (Hot Dry) | Method 501.7-Procedure II (A1) | Duration: 3 day exposure (3 X 24 hr. cycles) Temperature: 32-49°C cycling temperature exposure Table 501.7-III-Procedure. High temperature cycles, climate category A1 Hot Dry Unit is operational during test. |
Pass |
High Temperature Storage and Transit (Hot Dry) | Method 501.7-Procedure I (A1) | Duration: 7 day exposure (7 X 24 hr. cycles) Temperature: 33~71 °C cycling temperature exposure Table 501.7-III-Procedure. High temperature cycles, climate category A1 Hot Dry Unit is non-operational during test. |
Pass |
High Temperature Operational (Basic Hot) | Method 501.7-Procedure II (A2) | Duration: 3 day exposure (3 X 24 hr. cycles) Temperature: 30~43°C cycling temperature exposure Table 501.7-II-Procedure. High temperature cycles, climatic category A2 - Basic Hot Humidity: 14-44% Unit is operational during test. |
Pass |
High Temperature Storage and Transit (Basic Hot) | Method 501.7-Procedure I (A2) | Duration: 7 day exposure (7 X 24 hr. cycles) Temperature: 30~63°C cycling temperature exposure Table 501.7-II-Procedure. High temperature cycles, climatic category A2 - Basic Hot Humidity: 5-44% Unit is non-operational during test. |
Pass |
Low Temperature Storage and Transit (Basic climatic) | Method 502.7- Procedure I (C1) | Duration: 7 day exposure (7 X 24 hr. cycles) Temperature: -25--33°C Low temperature cycles, Table IX. Basic climatic_C1 Unit is non-operational during test. |
Pass |
Low Temperature Operational (Basic climatic) | Method 502.7- Procedure II (C1) | Duration: 3 day exposure (3 X 24 hr. cycles) Temperature: -21 - - 32°C Low temperature cycles, Table IX. Basic climatic_C1 Unit is operational during test. |
Pass |
Low Temperature Storage and Transit (Cold climatic) | Method 502.7- Procedure I (C2) | Duration: 7 day exposure (7 X 24 hr. cycles) Temperature: -37~-46℃ Low temperature cycles, Table XI. Cold climatic_C2 Wind speed less than 5m/s(11mph) Unit is non-operational during test. |
Pass |
Low Temperature Operational (Cold climatic) | Method 502.7- Procedure II (C2) | Duration: 3 day exposure (3 X 24 hr. cycles) Temperature: -37~-46℃ Low temperature cycles, Table XI. Cold climatic_C2 Wind speed less than 5m/s(11mph) Unit is operational during test. |
Pass |
Temperature Shock | Method 503.7- Procedure I-C | Duration: 1 Hour / Three cycles Temperature: -51 to 71°C Unit is non-operational during test. |
Pass |
Solar Radiation (Sunshine) | Method 505.7- Procedure I | Cycle A1. 01120 W/m2 at (280 ~ 3000) nm, 3 cycles Temperature: 32°C ~ 49℃ Unit is non-operational during test. |
Pass |
Humidity Aggravated Cycle | Method 507.6- Procedure II | Duration: 10 Days Temperature: 30°C and 60°C Humidity: 95% RH, constant Unit is non-operational during test. |
Pass |
Fungus | Method 508.8 | 5 fungus, 30°C, 95%RH 28 days, Non-Operating |
Pass |
Sand and Dust | Method 510.7- Procedure I | Particle density:10 +/- 7 g/m^3 Air velocity: 300 to 1750 ft/min Operating temperature of 60°C |
Pass |
Explosive Atmosphere | Method 511.7- Procedure I | Operation in an explosive atmosphere. | Pass |
Vibration | Method 514.8- Procedure I (Table514.8C-I) | Frequency 5-500Hz, Vertical rms = 1.08 g Transverse rms = 0.21g, Longitudinal rms = 0.76g Test Time: 60 minutes per axis (US highway truck vibration exposure) |
Pass |
Vibration | Method 514.8- Procedure I (Table514.8C-IV) | Frequency 5-500Hz, Vertical rms = 3.98 g Transverse rms = 1.22g, Longitudinal rms = 2.52g Test Time: 32 minutes per axis |
Pass |
Vibration | Method 514.8- Procedure I (Table514.8C-VII) | Frequency 5-500Hz, Vertical rms = 2.24 g Transverse rms = 1.45g, Longitudinal rms = 1.32g Test Time: 40 minutes per axis |
Pass |
Shock | Method 516.8- Procedure II | Functional Shock Operational 3 shocks/axis/direction for a total of 18 shocks; 40 Gs peak, 11 ms |
Pass |
Shock | Method 516.8- Procedure IV | Transportation shock- On road (5000Km) Amplitude : 5.1~ 7.6 G-Pk , Number of Shocks: 3 ~ 42 times Pulse Duration: 11ms |
Pass |
Shock | Method 516.8- Procedure VI | Crash Hazard Shock Test Non-OP/ Package 30~50 Gs peak, Trapezoidal pulse(772cm/s, 10G/each stage) |
Pass |
Shock | Method 516.8- Procedure III | Bench Handling (Drop Height : 100 mm) Unit is operational during test. |
Pass |
Fragility | Method 516.8- Procedure V | Non-operational 3 shocks/axis/direction for a total of 18 shocks Terminal Peak Sawtooth 2 shocks/axis/direction for a total of 12 shocks 75 Gs peak, 6 ms/Terminal Peak Sawtooth/unpackage nop |
Pass |
Rapid Temperature Change | Method 528.1- Procedure1 (Type 1) | Temperature: (30°C and -10°C) Humidity: 95% RH Dwell: 1Hour; Three cycles |
Pass |
Environmental Vibration | Method 514.8- Procedure I (Table514.8C-I) | 4~33 Hz/ 2Hours | Pass |
Mechanical Vibrations of Shipboard Equipment | Method 514.8- Procedure I (Table514.8C-VII) | Pass | |
Freeze/Thaw | Method 524.1- Procedure III | Pass | |
Sand and Dust | Method 510.7- Procedure II | Particle density:1.1 +/- 0.3g/m^3 Air velocity:28m/s Operating temperature of 60°C |
Pass |