INSTRUCTIONS PORTO GARAGE LIGHT FIELD-ADJUSTABLE INSTALLATION RAB Lighting is committed to creating high-quality, aff ordable, well-designed and energy-effi cient LED lighting and controls that make it easy for electricians to install

2 giorni fa — READ CAREFULLY BEFORE INSTALLING FIXTURE. RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE. RAB fixtures must be wired in accordance with the National ...

Instructions

PORTO Field Adjustable Garage Light - RAB Lighting


File Info : application/pdf, 4 Pages, 1.19MB

PDF preview unavailable. Download the PDF instead.

PORTO Instructions
INSTRUCTIONS
PORTO® GARAGE LIGHT FIELD-ADJUSTABLE INSTALLATION
RAB Lighting is committed to creating high-quality, affordable, well-designed and energy-efficient LED lighting and controls that make it easy for electricians to install and end users to save energy. We'd love to hear your comments. Please call the Marketing Department at 888-RAB-1000 or email: marketing@rablighting.com

PRT55R

PRT55S

PRT80R/PRT110R

PRT80S/PRT110S

IMPORTANT
READ CAREFULLY BEFORE INSTALLING FIXTURE. RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE. RAB fixtures must be wired in accordance with the National Electrical Code and all applicable local codes. Proper grounding is required for safety. THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED. WARNING: Make certain power is OFF before installing or maintaining fixture. No user serviceable parts inside. CAUTION: For proper weatherproof function all gaskets must be seated properly and all screws inserted and tightened firmly. Apply weatherproof silicone sealant around the edge of the ceiling mounting box and/or junction box. This is especially important with an uneven ceiling surface. Silicone all plugs and unused conduit entries. Suitable for wet locations. Covered ceiling mount only. Min. 90° supply conductors.

CEILING MOUNTING
The fixture is suitable for outdoor applications in wet locations.
1. Loosen Screws (2) to free Junction Box from Fixture Housing.
2. Mount Fixture Junction Box with Foam Gasket to ceiling using Knock Out Locations as needed (Fig. 1). Use the appropriate mounting hardware for the mounting surface. May alternately be mounted to a recessed junction box.
3. For hands-free wiring, suport the fixture with (2) Tether Cables as shown in Fig. 1 . Connect supply wires to Fixture. Power supply can enter from top of fixture or 1/2" Knockouts on side of fixture junction box. Use appropriate UL approved wire connectors as required by code to complete wiring as shown in Fig. 4.
4. Close fixture and tighten Screws (2). Use caution not to pinch wires. DO NOT OVER-TIGHTEN SCREWS.
5. If mounting surface is irregular, use sealer to seal any gaps around Junction Box.
PENDANT MOUNTING
Fixture can be mounted to a 1/2" NPT Pendant (by others).
1. Feed housing wires through Pendant and thread the Pendant onto the housing. Apply thread sealer or Teflon® to the Pendant threads to prevent moisture from getting into the housing.
2. Make wiring connections with UL approaved connectors at the junction box as shown in Fig. 4.

Fig: 1

Knock -out Locations

Fixture Junction Box

Photocell (do not open)

Foam Gasket
Tether Cable (2)

Fig: 2

Screws (2) Pendant (by others)
1/2" NPS

INSTRUCTIONS
PORTO® GARAGE LIGHT FIELD-ADJUSTABLE INSTALLATION
RAB Lighting is committed to creating high-quality, affordable, well-designed and energy-efficient LED lighting and controls that make it easy for electricians to install and end users to save energy. We'd love to hear your comments. Please call the Marketing Department at 888-RAB-1000 or email: marketing@rablighting.com

FIELD ADJUSTMENT
Caution: Turn power off before changing any settings.
Photocell Operation: This product is equipped with a photocell. Should you wish to disable this feature, slide the switch to the "Off" position. In addition to the standard photocell features, the fixture will not react to other light sources such as daylight. The fixture will not turn off. Allow 15 seconds for light to turn on/off when photocell is in "ON" position.
Color Temperature (CCT) Selection: This product is equipped with 3500, 4000 and 5000K CCT color temperature selection. For maximum light output use the 4000K Color Temperature.
Power (Wattage) Selection: This product is equipped with Power (W) output selection. PRT55 55/42/30W PRT80 80/70/60W PRT110 110/95/80W
Follow instructions below to change Photocell ON/OFF function, Color Temperature (CCT) and/or Power (W) from factory settings.
Factory Settings:
4000K CCT, Photocell/OFF
PRT55 55W PRT80 80W PRT110 110W
1. Locate the selector switche on underside of housing as shown in Fig. 3 and remove plug.
2. Select Color Temperature (CCT), Power (W) and or Photocell On/Off function by sliding the respective switch to the desired value (Fig. 3).
3. Re-Install Plug.

MVS /PIR MODELS (EXTERNAL)
(optional remote sold separately for custom settings, CAT# MSR1).

Factory Settings:

· Brightness: 100%

· Sensitivity: 100%

· Hold Time: 20 Minutes · Stand-by dimming level: 20%

· Daylight: Disabled · Stand-by time: 1 Minute

0-10V DIMMABLE WIRING
Universal voltage driver permits operation at 120V through 277V, 50 or 60 Hz. Units ordered with /480 suffix are 480V ONLY. For 0-10V dimming, follow the wiring directions as shown in Fig. 4. 1. Connect the black fixture lead to the LINE supply lead. 2. Connect the white fixture lead to the COMMON supply lead. 3. Connect the GROUND wire from fixture to supply ground. 4. Connect the purple fixture lead to the (V+) DIM lead. 5. Connect the pink fixture lead to the (V-) DIM lead. 6. Cap the yellow fixture lead, if present. Do NOT connect.
NOTE: Do not connect DIM V+ (purple)/ DIM V- (pink) to line voltage or supply ground.

Fig: 4
LINE COMMON ( + ) DIM V ( - ) DIM V

BLACK WHITE PURPLE PINK

LIGHT FIXTURE

Fig: 3

Photocell / CCT / Power (W) Switch

GROUND

GROUND

55W

ON

5000K

42W

4000K

30W

3500K

OFF

INSTRUCTIONS
PORTO® GARAGE LIGHT FIELD-ADJUSTABLE INSTALLATION
RAB Lighting is committed to creating high-quality, affordable, well-designed and energy-efficient LED lighting and controls that make it easy for electricians to install and end users to save energy. We'd love to hear your comments. Please call the Marketing Department at 888-RAB-1000 or email: marketing@rablighting.com

TROUBLESHOOTING
1. Check that the line voltage at the fixture is correct. Refer to wiring directions.
2. Be sure the fixture is grounded properly. 3. Is the photocell, if used, functioning properly?

CLEANING & MAINTENANCE
CAUTION: Be sure fixture temperature is cool enough to touch. Do not clean or maintain while fixture is energized. 1. Clean polycarbonate lens with non-abrasive cleaning solution. 2. Do not open the fixture to clean the LEDs. Do not touch the LEDs.

Note: These instructions do not cover all details or variations in equipment nor do they provide for every possible situation during installation, operation or maintenance.

© 2025 RAB LIGHTING Inc.
PORTO- IN - 1124 P-101470

Easy Answers

rablighting.com Visit our website for product info

Tech Help Line Call our experts: 888 722-1000

e-mail Answered promptly - sales@rablighting.com

Free Lighting Layouts Answered online or by request

RAB WARRANTY: RAB's warranty is subject to all terms and conditions found at rablighting.com/warranty PATENT: Patent information can be found at rablighting.com/ip

INSTRUCTIONS
PORTO® GARAGE LIGHT FIELD-ADJUSTABLE INSTALLATION

RAB Lighting is committed to creating high-quality, affordable, well-designed and energy-efficient LED lighting and controls that make it easy for electricians to install and end users to save energy. We'd love to hear your comments. Please call the Marketing Department at 888-RAB-1000 or email: marketing@rablighting.com

BATTERY BACKUP MODELS

WIRING
CAUTION: FOR BATTERY BACKUP FIXTURE. Voltage can be present in BATTERY. To prevent high voltage from being present on the output leads inverter connector must be open. Do not join Battery connector until installation is complete.
NOTE: Make sure that the necessary branch circuit wiring is available. An UNSWITCHED AC source of power is required. The emergency driver must be fed from the same branch circuit as the LED driver. Reference Fig. 5 for wiring diagram. CAUTION: Do not use any supply voltage other than 120-277V 50/60 HZ.

Fig. 5

GREEN White Black

GND AC/N AC/L

LED DRIVER

ADj+ Black ADj- Pink

Dim+

Purple

Pink Dim-

12V+ Yellow

LED+ Red Blue
LED-

Black Pink
Blue

Dip Box

Black White

Black LED-(WW)
White LED LED-(CW) Light Source
Red LED+

GND
AC N AC L AC L Switch

Blue/White Driver L
White
Neutral
Black AC line

LED Driver- Gray Purple
LED Driver+

Emergency Driver

LED- Black LED+ Red

Switch+

Brown AC L Switch

Switch-

Test Switch

BATTERY

OPERATION
1. When AC power is applied the charging indicator light is illuminated indicating that the BATTERY is being charged.
2. When power fails the standby power automatically switches to emergency power (internal battery) operating at reduced illumination. The emergency driver will operate in standby power for a minimum of 90 minutes.
3. When AC power is restored the emergency driver
automatically returns to charging mode.

1. Connect UNSWITCHED HOT fixture lead to HOT AC supply line.
2. If using an UNSWITCHED circuit, connect UNSWITCHED and SWITCHED lines together.
3. If using a SWITCHED circuit, connect SWITCHED HOT lead to the switch.
4. For 0-10V dimming, connect DIM (+) purple and DIM (-) pink leads to 0-10V dimming connection.
5. All unused leads must be capped and insulated.
6. When power is on, the fixture should be ON and the CHARGING INDICATOR LIGHT should illuminate to indicate the battery is charging.
7. Once the BATTERY has charged for at least one hour a short duration test may be performed by pressing the Test Button (Fig. 6).
8. After the battery has charged for 24 hours a long duration test can be performed by shutting power to the fixture.
MAINTENANCE
Although no routine maintenance is required to keep the emergency driver functional it should be checked periodically to ensure that it is working. The following schedule is recommended:
1. Visually inspect the charging indicator light monthly. It should be illuminated.
2. Test the emergency operation of the fixture at 30-day intervals for a minimum of 30 seconds.
3. Conduct a 90-minute discharge test once a year. Fixture will operate at reduced illumination for a minimum of 90 minutes.

TROUBLESHOOTING
1. Is the fixture grounded properly?
2. If the charging indicator light does not illuminate after pressing the Test Button (Fig. 6), check if battery is connected properly.

TEST BUTTON
Fig: 6

PRT55R

PRT55S

PRT80R/PRT110R