Installation Manual

Type: Enclosed Type Switching Power Supply

Families: CSP, ENP, ERP, G3, HDP, HEP, HRP, HRPG, HSP, LRS, MSP, NED, NEL, NES, PSP, PSPA, QP, RS, RSP, RST, SE, SP, SPV, TP, UHP, USP

Introduction

Enclosed type switching power supplies possess a metal or plastic case for covering their internal PCB and will be installed inside the case of the end system. Mean Well's enclosed type power supplies include 2 different groups of power supplies, with built-in fan and without built-in fan, depending on their rated power or design concept.

Installation

  1. Before any installation or maintenance work, please disconnect your system from the utility. Ensure that it can't be re-connected inadvertently!
  2. Keep enough insulation distance between mounting screws and internal components of power supplies. Please refer to case drawing on specifications to receive the maximum length of mounting screw.
  3. Mounting orientations other than standard orientation or operate under high ambient temperature may increase the internal component temperature and will require a de-rating in output current. Please refer to the specification sheets to receive the optimum mounting position and information about the de-rating curve.
  4. Fans and ventilation holes must be kept free from any obstructions. Also a 10-15 cm clearance must be kept when the adjacent device is a heat source.
  5. Input and Output terminal specifications are provided in the following tables.
  6. Torque can be various due to different material; please refer to the following charts for recommendations for aluminum and iron.
  7. Recommended wires are shown in the table below. Note: Current each wire carries should be de-rated to 80% of the current suggested above when using 5 or more wires connected to the unit. Make sure that all strands of each stranded wire enter the terminal connection and the screw terminals are securely fixed to prevent poor contact.
  8. Wiring: Wire color will vary by country; please refer to the table below for North America and European Harmonized standards. Ensure all wires are secured to prevent poor contact.
  9. For other information about the products, please refer to www.meanwell.com for details.

Input and Output Terminal Torque Specifications

SeriesInput Terminal ScrewInput Screw SizeInput Suggested TorqueOutput Screw SizeOutput Suggested Torque
RSP-750 / 1000 / 1500 / 2000 / 2400 / 3000
SE-450 / 1000 / 1500
M410-12kgf-cmM410-12kgf-cm
HEP-600, HRP-300, HRPG-300, MSP-300M410-12kgf-cmM410-12kgf-cm
SP-480, SP-750, SPV-1500, USP-500, RST-10000M410-12kgf-cmM810-12kgf-cm
HRP-075 / 100 / 150 / 200, HRPG-150 / 200M3.58-10 kgf-cmM3.58-10 kgf-cm
LRS-035 / 050 / 075 / 100 / 150 / 150F / 200 / 350
MSP-100 / 200
M3.58-10 kgf-cmM3.58-10 kgf-cm
NED-035 / 050 / 075 / 100, NET-035 / 050 / 075M3.58-10 kgf-cmM3.58-10 kgf-cm
NES-025 / 035 / 050 / 075 / 100 / 150 / 200 / 350
QP-200 / 320 / 375
M3.58-10 kgf-cmM3.58-10 kgf-cm
RD-050 / 065 / 085 / 125, RID-050 / 065 / 085 / 125
RS-035 / 050 / 075 / 100 / 150
M36-8 kgf-cmM36-8 kgf-cm
RSP-075 / 100 / 150 / 200 / 320
SP-075 / 100 / 150 / 200 / 240 / 320, SPV-150 / 300
SE-100 / 200 / 350, HSP-250, PSP-600
M36-8 kgf-cmM36-8 kgf-cm
RSP-1600M36-8 kgf-cmM36-8 kgf-cm
RD-035, RT-050 / 065 / 085 / 125
RQ-050 / 065 / 085 / 125
M36-8 kgf-cmM36-8 kgf-cm
TP-075 / 100 / 150, QP-100 / 150
RS-015 / 025
NES-015, USP-150
M36-8 kgf-cmM36-8 kgf-cm
ERP-350#68-10 kgf-cmM410-12kgf-cm
HDP-190 / 240#68-10 kgf-cmM410-12kgf-cm
NEL-200 / 300#68-10 kgf-cmM38-10kgf-cm
ENP-120 / 180 / 240 / 360M2.64-5 kgf-cmM410-12kgf-cm
HRP-450 / 600
HRPG-450 / 600
MSP-450 / 600 / 1000
SE-600
M36-8kgf-cmM410-12kgf-cm
HSP-150 / 200 / 300
HSN-200 / 300
M36-8kgf-cmM3.58-10kgf-cm
RSP-500M3.58-10kgf-cmM410-12kgf-cm
RST-5000M410-12kgf-cmM810-12kgf-cm
NEL-400#68-10kgf-cmM38-10kgf-cm
UHP-200(R) / 350(R)M35kgf-cmM3.58kgf-cm
UHP-200AM3.513kgf-cmM3.58kgf-cm
CSP-3000M410-12kgf-cmM613kgf-cm
UHP-500(R) / 750 / 1000M35kgf-cmM410-12kgf-cm
HEP-600 / 1000M410-12kgf-cmM410-12kgf-cm

Torque Recommendations

A. Recommended torque for aluminum

Size of screw (Imperial units)Recommend torque (kgf-cm)
3-562.3±20%
4-403.0±20%
4-483.3±20%
5-404.5±20%
5-444.7±20%
6-325.6±20%
6-406.3±20%
8-3210.4±20%
8-3610.8±20%

A. Recommended torque for aluminum (Metric Units)

Size of screw (Metric Units)Recommend torque (kgf-cm)
M2.52.2±20%
M34.1±20%
M3.56.5±20%
M49.7±20%
M519.5±10%
M633.1±10%
M755.3±10%
M880.6±10%

B. Recommend torque for iron

Size of screw (Imperial units)Recommend torque (kgf-cm)
3-565.0±20%
4-406.9±20%
4-487.0±20%
5-409.4±20%
5-449.9±20%
6-3212.0±20%
6-4013.4±20%
8-3221.8±20%
8-3623.0±20%

B. Recommend torque for iron (Metric Units)

Size of screw (Metric Units)Recommend torque (kgf-cm)
M2.54.6±20%
M38.8±20%
M3.513.7±20%
M420.4±20%
M541.1±10%
M669.1±10%
M7117.5±10%
M8169.4±10%

If above mentioned is not enough due to special application, Nylok Blue Patch screw is recommended, and extra torque can be added if needed.

Recommended Wires

AWG18161412108
Rated Current of Equipment (Amp)6A6-10A10-16A16-25A25-32A32-40A
Cross-section of Lead(mm²)0.751.001.52.546

Note: Current each wire carries should be de-rated to 80% of the current suggested above when using 5 or more wires connected to the unit. Make sure that all strands of each stranded wire enter the terminal connection and the screw terminals are securely fixed to prevent poor contact.

Wiring

The wire color will vary by country; please refer to the table below for North America and European Harmonized standards.

North AmericaEuropean Harmonized
Live and ACLBlackBrown
Neutral and ACNWhiteBlue
PE and FG (Class I only)GreenGreen/yellow

a) Connect the FG wire (green or green/yellow) of the power supply to PE (green or green/yellow); this step can be skipped when the unit is marked class II, ungrounded.

b) Connect the ACL wire (black or brown) of the power supply to Live (black or brown).

c) Connect the ACN wire (white or blue) of the power supply to Neutral (white or blue).

d) Make sure all wires are secured to prevent poor contact.

Wiring Diagram Description

The diagram illustrates a basic AC input connection for a Power Supply Unit (PSU). The input lines are labeled LIVE/HOT (Black or brown), NEUTRAL (White or blue), and PE (Green or green/yellow). These lines connect to the PSU's AC/L, AC/N, and FG terminals, respectively. A circuit breaker (CB) and a line connection (LINC) are shown in the path of the AC input to the PSU.

Warning / Caution

Manufacturer and Branch Offices

Manufacturer

MEAN WELL ENTERPRISES CO., LTD.
No.28, Wuquan 3rd Rd., Wugu Dist.,
New Taipei City 24891, Taiwan
Tel: +886-2-2299-6100
Web: www.meanwell.com

Branch Offices

China

MEAN WELL (GUANGZHOU) ENTERPRISES CO., LTD.
2F, A Building, Yuean Industry Park, Huangcun, Dongpu Yown, Tianhe District, Gungzhou, China
Post Code: 510660
Tel: +86-20-2887-1200
Web: www.meanwell.com.cn

China

MEAN WELL (GUANGZHOU) ENTERPRISES CO., LTD.
No.11, Jingu South Road, Huadong Town, Huadu Distric, Guangzhou, Gungzhou, China
Tel: +86-20-3773-7100
Web: www.meanwell.com.cn

China

SUZHOU MEAN WELL TECHNOLOGY CO., LTD.
No.77, Jian-Ming Rd. Dong-Qiao, Pan-Yang Ind. Park, Huang-Dai Town, Xiang-Cheng District, Suzhou, Jiang-Su, China
Post Code: 215152
Tel: +86-512-6508-8600
Web: www.meanwell.cc

U.S.A.

MEAN WELL USA, INC.
44030 Fremont Blvd., Fremont, CA 94538, U.S.A.
Tel: +1-510-683-8886
Web: www.meanwellusa.com

Europe

MEAN WELL EUROPE B.V.
Langs de Werf 8, 1185XT Amstelveen, The Netherlands
Tel: +31-20-758-6000
Web: www.meanwell.eu

Declarations

Declaration of China RoHS Conformity

In order to reduce the impacts on the environment and take the more responsibility for protecting the earth, MEAN WELL is confirming and announcing the conformity to China RoHS, an Administrative Measures for the Restriction of the Use of Hazardous Substances in Electrical and Electronic Products.

Environment Friendly Use Period Label

[10-year use period label] Observing SJT 11364-2014, Marking for the Restricted Use of Hazardous Substances in Electronic and Electrical Products. Observing SJ/Z 11388-2009, General Guidelines of Environment-friendly Use Period of Electronic Information Products Appendix B, adopting table look-up to verify the Environment Friendly Use Period.

Names and Contents of Hazardous Substances Lists

Part NameLead (Pb)Mercury (Hg)Cadmium (Cd)Hexavalent Chromium (Cr6+)Polybrominated biphenyls (PBB)Polybrominated diphenyl ethers (PBDE)
PCB and its componentsXOXOOO
Metal structure partsXOOOOO
Plastic structure partsOOOOOO
AccessoriesOOOOOO
CablesXOOOOO

O: The concentration of the hazardous substances within the homogeneous material of that product is less than the concentration limits set by GB/T 26572-2011.
X: The concentration of the hazardous substances within the homogeneous material of that product is over the concentration limits set by GB/T 26572-2011; however, it follows the standard advised by 2011/65/EU.

Declaration of China VOC Conformity

In order to reduce the impacts on the environment and take the more responsibility for protecting the earth, MEAN WELL is confirming and announcing the conformity to China's Standardization Administration Releases VOC Standards.

Standard No.Name of the Standard
GB 30981-2020Limit of harmful substances of industrial protective coatings
GB 33372-2020Limits for volatile organic compounds content in adhesive
GB 38507-2020Limits for volatile organic compounds (VOCs) In printing ink
GB 38508-2020Limits for volatile organic compounds content in cleaning agents

Declaration of Five PBT TSCA Conformity

In order to reduce the impacts on the environment and take the more responsibility for protecting the earth, MEAN WELL hereby confirms that MEAN WELL product series comply with Use and Risk Management for Five PBT Chemicals under TSCA section 6(h).

CAS No.Substance Name
1163-19-5Decabromodiphenyl ether (DecaBDE)
68937-41-7Phenol, isopropylated, phosphate (3:1) PIP (3:1)
732-26-32,4,6-Tris (tert-butyl) phenol (2,4,6-TTBP)
133-49-3Pentachlorothiophenol (PCTP)
87-68-3Hexachlorobutadiene (HCBD)

PDF preview unavailable. Download the PDF instead.

Enclosed Type EN Microsoft Word 2013

Related Documents

Preview MEAN WELL Switching Power Supply Catalog
Comprehensive catalog of MEAN WELL switching power supplies, featuring a wide range of models including LRS, RSP, SE, G3, and QP series, with detailed specifications and applications.
Preview MEAN WELL Power Supplies Catalog - August 2020
Explore the comprehensive MEAN WELL Power Supplies Catalog for August 2020. This catalog details a wide range of AC/DC and DC/DC power supplies, including industrial, medical, DIN rail, open frame, and adaptor series, with detailed specifications and model information.
Preview MEAN WELL Power Supply Catalog - Standard Switching Power Supplies
Comprehensive catalog of MEAN WELL's reliable power solutions, including AC/DC enclosed power supplies, external adapters, DC/DC converters, DC/AC inverters, and more. Featuring detailed specifications and product information.
Preview MEAN WELL Industrial Power Supply Catalog - Comprehensive Product Guide
Explore the extensive MEAN WELL Industrial Power Supply Catalog, featuring a wide range of standard switching power supplies, AC/DC converters, adapters, and more. Find detailed specifications, model numbers, and features for industrial, medical, and specialized applications.
Preview MEAN WELL: Your Reliable Power Partner - Standard Switching Power Supply Manufacturer
Explore MEAN WELL's extensive range of standard switching power supplies, LED drivers, DC-DC converters, and more. Discover reliable power solutions for industrial, medical, and communication applications.
Preview MEAN WELL Power Supply Catalog: Reliable Industrial Power Solutions
Explore the comprehensive MEAN WELL catalog featuring a wide array of industrial power supplies, AC/DC converters, DC/DC converters, and DC/AC inverters. Discover reliable, efficient, and high-quality power solutions for professional applications.
Preview 明纬标准开关电源制造商产品目录与公司概览
本PDF文件提供了明纬(MEAN WELL)公司简介、发展历程、企业竞争力以及全面的标准开关电源产品目录。内容涵盖AC-DC机壳型、适配器、逆变器、DC-DC转换器、电池充电器和VFD变频器等系列,并列出详细的产品型号、规格和应用。
Preview Mean Well Switching Power Supply Technical Manual: Comprehensive Guide
Detailed technical manual for Mean Well Switching Power Supplies (SPS). Covers circuit principles, specifications, safety, EMC, reliability, operation, and troubleshooting for industrial and commercial applications. Essential resource for engineers and technical professionals.