Homsure AP10-2012EE Dehumidifier User Manual

Customer Service Email: service-eur@humsure.com

Contact Us

We guarantee a replacement or a full refund if you have any problems with your dehumidifier in the future. Please keep this manual for future reference.

ATTENTION: Contact us to get a FULL REFUND or a REPLACEMENT if you have any problems with this product.

Product Overview

Thank you for choosing our dehumidifier. Please read this manual carefully before use. If you have any questions, please contact our Customer Service. Keep this manual handy for future reference.

Languages Included:

English Instructions

Page 01-12

Content

Before First Use

To prevent any unintended damage, please leave the appliance standing upright for 2 HOURS before plugging it in. Please always keep the appliance upright on a flat surface during use.

Placement:

Notice of Compressor Running Status:

It's a normal phenomenon that the compressor and fan keep running when the ambient humidity reaches the preset RH. The fan stops 5 minutes after the preset RH is reached. The compressor stops when the ambient humidity is 4% lower than the preset RH, and it starts automatically when the ambient humidity level is 4% higher than the preset level. The Return Difference design featuring 4% error range is for better protecting and prolonging lifespan of the appliance.

Notice of Full Tank Detection:

  1. There may be a few residual water in the water collecting tray while the tank full indicator light is on. Please wait for several minutes before taking out the water tank.
  2. The fan will keep working for 5 minutes and the compressor will auto shut off when the tank full indicator light is on for protection. The fan will auto shut off after an extra 5-minute work if the water tank is still full.

Important Safety Instructions

  1. Keep the dehumidifier standing upright for 2 hours after it is tilted.
  2. Keep the dehumidifier at least 10 inches away from the surroundings.
  3. Place the dehumidifier on a flat and sturdy surface.
  4. Keep the dehumidifier grounded.
  5. Turn off the dehumidifier and empty the water tank before moving it.
  6. Do not turn off the dehumidifier by directly unplugging it. Press the "ON/OFF" button instead.
  7. Turn off and unplug the dehumidifier before cleaning.
  8. Never insert your finger or other objects into the inlet grid/filter.
  9. Do not cover the inlet or outlet grid with cloths or towels.
  10. Pay special attention when using the dehumidifier in a room with infants, children, and the elderly.
  11. Do not climb or sit and place heavy objects on the dehumidifier. Take special care to warn children of this.
  12. Please keep the dehumidifier away from heat sources and chemicals area.
  13. Do not use the dehumidifier in a location exposed to flammable gas or combustibles, such as gasoline, benzene, thinner, etc.
  14. Do not use the dehumidifier in places where it may be splashed with water.
  15. Do not take the water tank out while the dehumidifier is working.
  16. Do not use other detergents to clean the dehumidifier. Clean it with a soft cloth instead.
  17. Please turn off and disconnect the power if there is a strange sound, smell, or smoke.
  18. Do not dismantle or modify the dehumidifier or the power cord on your own. Please contact us at service-eur@humsure.com immediately if they are damaged. We will offer you a full refund or a free replacement.

Product Details

1 Air Outlet

2 Control Panel

3 Handle

4 Inlet Grid/Filter

5 Water Tank

6 Continuous Drainage Outlet

7 Power Cord

8 Caster

Specifications

Mode II Nr: AP10-2012EE
Nennspannung: 220-240V~
Nennfrequenz: 50HZ
Nenneingangsleistung: 200W
max.Eingangsleistung: 230W
Nenneingangsleistung: 1.26A
max.Eingangsstrom: 1.35A
Schalldruckpegel: ≤45dB(A)
Kältemittelfüllung: R290/40g
Reingewicht: 9.1Kg

Operation Control Panel

ON/OFF: Plug the dehumidifier in, and then press ON/OFF to turn it on/off.

MODE: Short press MODE to choose the desired mode.

Mode RH Operation RH Adjustment Turbine Speed
STANDARD 40%-80% Manual setting

✔️

High
RAINING 45% Automatic Setting

High
DRYING Continuous Operation (CO) Automatic Setting

High
SLEEP 50% Automatic Setting

Low

TIMER: Press TIMER to set the timing of Auto-start or Auto-stop from 0 to 24 hours.

HUMIDITY: Press HUMIDITY to set the humidity level ranging from RH 40% to RH 80% and CO (Continuous Operation) under standard mode.

OTHERS:

Drainage

There are two methods of drainage to choose from.

01 Manual Drainage

When the tank gets full, the dehumidifier will alarm and stop working automatically. Meanwhile, the "FULL" indicator light will turn on. It is suggested to pour out the water in the tank.

  1. Take out the tank gently.
  2. Empty the tank and put it back in place. (If the tank is not placed correctly, the FULL indicator light will remain on)

02 Continuous Drainage (optional)

  1. Take out the water tank to find out the continuous drainage outlet.
  2. Plug the drain hose in securely, and then put the water tank back in place. Keep the hose downward to ensure proper drainage.

Care & Cleaning

Attention: Keep the machine unplugged before maintaining or washing.

  1. Please clean the dehumidifier after turning it off for 1 hour.
  2. Please use a slightly water-dampened cloth to clean the dehumidifier.
  3. Please do not use volatile chemicals, gasoline, detergent, chemical processed fabrics or other cleaning solutions, which may be harmful to the dehumidifier.
  4. Please do not wash the dehumidifier with direct water.

Storage

If you do not need to use the dehumidifier for a long time, please store it in the following ways:

  1. Turn off the dehumidifier, cut off the power and sort out the power cord.
  2. Empty the water tank and keep it dry.
  3. Clean the filter and dry it out.
  4. Store the dehumidifier in a cool and dry place.

Notice of Continuous Drainage

Wrong Drainage Methods

  1. If there is a U shape or a V shape between two ends of the hose, the increasing accumulation of water in the valley may stop water from draining to the water collecting vessel. It eventually leads to a backflow to water tank or a water leak from other lower parts of the appliance.
  2. If there is no space between the outlet of hose and the water collecting vessel, the increasing pressure of water caused by raising water level may result in a failure of drainage from the appliance. It eventually leads to a backflow to water tank or a water leak from other lower parts of the appliance.

Advised Drainage Methods

This method is applicable for external water collecting vessel, please note the following:

  1. Keep the hose downward.
  2. Make sure the drainage outlet of the appliance is always higher than the maximum water level of the water collecting vessel or water may flow backward.
  3. Make sure there is always a height difference of 5.5 in between the outlet of hose and the drainage outlet of the appliance. The outlet of hose should be 5.5 in lower all the time.

This method is applicable for floor drain. Securely connect the hose to the appliance and place the other end to the floor drain.

Troubleshooting

PROBLEMS PROBABLE REASONS SOLUTIONS
The dehumidifier does not work. The power cord is not firmly plugged in the socket. Make sure the power cord is securely plugged in the socket.
Dehumidifying effect is not obvious. Or the dehumidifier is not removing moisture. The "FULL" indicator light is on.
The room humidity is lower than setting.
The filter is dusty.
The inlet or outlet is blocked.
Doors and windows are open.
The room temperature or humidity is too low.
Please remove the water from the tank or replace the tank in its place.
Please reset the humidity setting of the machine to ensure it is lower than the humidity of the room.
Please clean the filter and make sure there is at least a 10-inch space around the dehumidifier.
Check that all doors and windows are securely closed.
This is normal.
The dehumidifier is a little noisy. The vibration may be caused by uneven placement. Please put the machine in a flat place.
The air turbine does not work. The filter is clogged. Please clean the filter.
The display shows "E1", "E2" or "H1" E1/E2: The component inside dehumidifier is under open circuit or short circuit.
H1: The indoor temperature is higher than 167°F.
Please clean the filter.

If you have any other problems, please contact us to get a replacement or a full refund.

Customer Service Email: service-eur@humsure.com

German Instructions

Page 13-24

INHALT

French Instructions

Page 25-36

Contenu

Spanish Instructions

Page 37-48

CONTENIDO

Italian Instructions

Page 49-60

CONTENUTO

About Warranty

Q: Do you have warranty for this product?

A: We strictly abide by the Amazon regulations which cover a full refund or a free replacement within 30 days if this product breaks under normal use or unintended damage. You may also get additional 1-year warranty after registering your order information in our warranty system.

Q: How can I get the additional warranty?

A: Please enter www.humsure.com/ to register in Homsure warranty system. And we promise our team always stands behind our product, we will try our best to help you get a better experience on the product.

Models: AP10-2012EE, AP10-2012EE Dehumidifier, AP10-2012EE, Dehumidifier

File Info : application/pdf, 33 Pages, 4.03MB

PDF preview unavailable. Download the PDF instead.

17261261461248280108

References

Adobe PDF library 16.07 Adobe Illustrator 27.0 (Windows)

Related Documents

Preview Homsure Dehumidifier User Manual: Operation, Care, and Troubleshooting
Comprehensive user manual for the Homsure Dehumidifier (Model AP25-2007EE). Includes setup, operation, cleaning, maintenance, troubleshooting, safety guidelines, and warranty information. Enhance your home's comfort by effectively managing humidity.
Preview Homsure Dehumidifier User Manual
Comprehensive user manual for the Homsure Dehumidifier, covering setup, operation, maintenance, troubleshooting, and warranty information. Learn how to effectively use and care for your Homsure dehumidifier for a healthier home environment.
Preview Homsure AP20-801EE Dehumidifier User Manual and Operation Guide
This user manual provides comprehensive instructions for operating and maintaining the Homsure AP20-801EE dehumidifier. Learn about features, safety precautions, troubleshooting, and maintenance for optimal performance.